首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 78 毫秒
1.
目的探讨维生素D缺乏诱导呆小病新生儿血液中微量元素含量的变化。方法采用微分电位溶出法测定维生素D缺乏诱导呆小病的新生儿与健康新生儿血液中微量元素的含量。结果呆小病组血清锌、镁、铁、钙均低于正常,全血铅、血清铜均高于正常。结论小儿维生素D缺乏诱导呆小病新生儿血液微量元素存在一定的失衡,与感染所造成的机体伤害有一定的关系,因此需要及时补充和调理微量元素,对疾病的治疗和恢复有重要意义。  相似文献   

2.
Topbas OF  Jehle R  Sinha P  Rüstow B 《Electrophoresis》2000,21(17):3552-3557
Vitamin E is the most important lipophilic antioxidant. Oxidative injuries are prevented or minimized by vitamin E supplementation. Various physiological and pathological situations are accompanied by vitamin E deficiency. However, it is not clear whether alimentary vitamin E deficiency in itself constitutes oxidant stress that induces appropriate responses, which, in turn, can be avoided by adequate vitamin E supplies, or whether the remaining cellular antioxidants compensate a temporary vitamin E deficiency. We studied effects of the dietary vitamin E status on cellular vitamin E levels and on the expression of heat shock proteins (HSPs) in alveolar type II cells and liver. The expression of HSPs, representing an early and very sensitive marker of cellular stress, was compared with the activity of antioxidative enzymes. Vitamin E depletion caused a substantial increase in HSP32 in alveolar type II cells, whereas in liver there was a marked increase in HSP70. The activity of the antioxidant enzymes, however, did not change significantly. A reversal of HSP expression to almost normal levels was seen after vitamin E resupplementation. These results indicate that, under normal conditions, a suboptimal supply of vitamin E to rats exposes the alveolar type II cells and the liver to reversible cellular stress.  相似文献   

3.
Vitamin D deficiency is prevalent in the Arabian Gulf region, especially among women. Recent studies show that the vitamin D deficiency is associated with a mineral status of a patient. Therefore, it is important to assess the mineral status of the patient to reveal the hidden mineral imbalance associated with vitamin D deficiency. A well-known test such as the red blood cells is fairly expensive, invasive, and less informative. On the other hand, a hair mineral analysis can be considered an accurate, excellent, highly informative tool to measure mineral imbalance associated with vitamin D deficiency. In this study, 118 apparently healthy Kuwaiti women were assessed for their mineral levels and vitamin D status by a hair mineral analysis (HMA). This information was used to build a computerized model that would predict vitamin D deficiency based on its association with the levels and ratios of minerals. The first phase of the proposed model introduces a novel hybrid optimization algorithm, which can be considered as an improvement of Bat Algorithm (BA) to select the most discriminative features. The improvement includes using the mutation process of Genetic Algorithm (GA) to update the positions of bats with the aim of speeding up convergence; thus, making the algorithm more feasible for wider ranges of real-world applications. Due to the imbalanced class distribution in our dataset, in the second phase, different sampling methods such as Random Under-Sampling, Random Over-Sampling, and Synthetic Minority Oversampling Technique are used to solve the problem of imbalanced datasets. In the third phase, an AdaBoost ensemble classifier is used to predicting the vitamin D deficiency. The results showed that the proposed model achieved good results to detect the deficiency in vitamin D.  相似文献   

4.
The determination of vitamin K3 using the coupling between a photochemical reaction and a chemiluminescent reaction in a flow system is described. The method is based on the photooxidation of ethanol sensitized by vitamin K3 to yield hydrogen peroxide, which is monitored through the chemiluminescent reaction with luminol catalysed by hematin. The new approach allows the determination of vitamin K3 in a wide concentration range (1 x 10(-7)-5 x 10(-4) mol l-1) with a throughput of 30 samples h-1. The applicability of the method was demonstrated by the determination of vitamin K3 in pharmaceutical preparations.  相似文献   

5.
Vitamin K is a fat-soluble vitamin involved in blood coagulation and bone metabolism. The detection and monitoring of vitamin K homologues in rheumatoid arthritis (RA) patients is a challenging problem due to the smaller concentrations of vitamin K and the presence of several interfering medications. Therefore, this study aimed to develop a new highly sensitive and selective chemiluminescence (CL) method designated to quantify vitamin K homologues in plasma of RA patients including phylloquinone (PK, vitamin K1), menaquinone-4 (MK-4, vitamin K2) and menaquinone-7 (MK-7, vitamin K2). The method was based on the unique photochemical properties of vitamin K homologues that were exploited for selective luminol CL reaction. The correlation coefficients of 0.998 or more were obtained in the concentration ranges of 0.1-100 ng mL−1 vitamin K homologues. The detection limits were 0.03-0.1 ng mL−1 in human plasma for vitamin K homologues. The developed HPLC-CL system was successfully applied for selective determination of vitamin K homologues in plasma of RA patients. The developed method may provide a useful tool for monitoring vitamin K homologues in different clinical studies such as RA, osteoporosis and hepatocellular carcinoma in which vitamin K is intervented.  相似文献   

6.
It is widely recognized that vitamin D deficiency has detrimental health consequences. The ultraviolet (UV) B radiation increases the serum vitamin D level, expressed by 25-hydroxyvitamin-D(3) [25(OH)D]. An analytical model is presented to calculate the serum 25(OH)D changes throughout a year, caused by the solar exposure variability due to geophysical and habitual factors. The model is tuned by taking into account recent experimental results of serum 25(OH)D changes, after a series of artificial (by fluorescent tubes) UV exposures. The model uses the erythemal and vitamin D weighted irradiances, inferred from the Brewer spectrophotometer and the Kipp and Zonen broad-band meter measurements, carried out in Belsk (52°N, 21°E), Poland, in 2010. The modeled seasonal pattern of the serum 25(OH)D concentration in Polish indoor workers is only slightly different, than in subjects with typical outdoor activity habits, and in those with sun-seeking behavior. A deep minimum in the serum 25(OH)D concentration appears in late winter, regardless of outdoor activity habits. An extra sunbathing to boost the vitamin D level is not worth taking, because of a minor improvement of the vitamin D status, and because of a greater erythema risk. It would be much safer and more effective to maintain an adequate vitamin D level through diet supplements, even in summer, for non sun-seeking subjects.  相似文献   

7.
Vitamin K(1) is a fat-soluble vitamin required for the gamma-carboxylation of vitamin K-dependent proteins. Recent work has suggested an important role for vitamin K(1) in bone health beyond its more established function in the control and regulation of blood coagulation. However, current UK recommended intakes do not reflect this recent evidence. The use of stable isotopes provides a powerful tool to investigate vitamin K kinetics, turnover and absorption in man, although published methods have reported difficulties in the extraction and analysis of isotope ratios of vitamin K in human plasma. In this paper, we report a new methodology for the extraction and measurement of isotope ratios in vitamin K(1). Sample clean-up is achieved with liquid-liquid extraction, enzyme hydrolysis with lipase and cholesterol esterase, and solid-phase extraction. Isotopic analysis of the pentafluoropropionyl derivative of vitamin K(1) is performed by gas chromatography/mass spectrometry (GC/MS). The limit of quantitation is equivalent to at least 0.3 nmol/L and the method is demonstrated to be linear over a range of enrichments. This method provides a robust alternative to previous work requiring the use of semi-preparative high-performance liquid chromatography (HPLC).  相似文献   

8.
A liquid chromatographic (LC) method is described for the determination of vitamin K1 in medical foods. The sample is enzymatically digested with lipase and alpha-amylase and extracted with 1% sodium bicarbonate solution-isopropanol (1 + 1). After C18 solid-phase extraction, vitamin K1 is separated by nonaqueous reversed-phase LC, converted to the hydroquinone by postcolumn zinc reduction, and quantitated by fluorescence detection. The limit of detection is 8 pg (3 sigma), and the limit of quantitation is 27 pg (10 sigma) on column. Linear response ranged from 0.1 to 1.0 ng vitamin K1 (r= 0.9999). The mean recovery (n = 38) for all spiking levels was 101.6 +/- 2.85%. Analysis of Standard Reference Material 1846, Infant Formula, gave a mean value of 0.95 +/- 0.088 mg vitamin K/kg (K or K1?) (n = 31) with a coefficient of variation of 9.26.  相似文献   

9.
Determination of small amounts of vitamin K1 (0.8 microg/g) in nutritional supplements with high fat content (20 mg/g) was performed by solid-phase extraction and high-performance liquid chromatography (HPLC) with fluorescence detection after reduction on a platinum oxide catalyst. The concentration ratio of plant oils to vitamin K1 (0.8 microg/g) was about 25,000:1. A sample solution was applied to a solid-phase extraction cartridge and vitamin K1 was eluted with ethanol, followed by HPLC. The proposed method was simple, rapid (analysis time: ca. 12 min), sensitive [detection limit: ca. 0.1 pg per injection (100 microl) at a signal-to-noise ratio of 3:1], highly selective and reproducible [relative standard deviation: ca. 1.3%. (n=5)]. The calibration graph of vitamin K1 was linear in the range of 0-2 pg per injection (100 microl). Recovery of vitamin K1 was over 90% by the standard addition method.  相似文献   

10.
冀亚飞  石俊英 《应用化学》1998,15(4):98-100
维生素K1分子侧链上有一双键,因而存在几何异构体.天然维生素K1是2,3一反式构型,合成品为顺式和反式异构体的混合物,而顺式异构体几乎没有生理活性.故此,八十年代以后,各国药典均对维生素K;顺式异构体规定了限量,中国药典(1995版)规定顺式异构体的含量不得超过ZI.0%[’].目前国内流行的制备方法是以甲素配为起始原料,须经还原、乙酸化、水解、缩合、再水解和氧化五步反应制得[’],步骤长、收率低、对环境污染大.而用异植物酶合成引人侧链时,制备的维生素K;顺式异构体含量较高,达不到药典要求.为满足新版药典的…  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号