首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel phosphonic acid containing bisphenol was successfully synthesized from phenolphthalein and m‐aminophenylphosphonic acid. A series of homo‐ and copoly‐(arylene ether)s containing phosphonic acid groups were prepared by solution nucleophilic polycondensation. These phosphonic acid containing polymers can readily be dissolved in common organic solvents, such as dimethyl sulfoxide, N‐methyl‐2‐pyrrolidinone, and N‐cyclohexylpyrrolidinone, and can be cast into tough and smooth films. The presence of phosphonic acid pendants in the poly‐(arylene ether)s was confirmed by NMR, matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry, and conductivity measurements. This is the first report on the attachment of phenylphosphonic acid groups as side chains to aromatic polyethers. These poly‐(arylene ether)s had very high glass‐transition temperatures ranging from 254 to >315 °C and high molecular weights. The conductivities of the synthesized polymers were analyzed by the Cole–Cole method, and they ranged from 10?5 to 10?6 Scm?1. The synthesized polymers also exhibited good solution processability. © 2001 John Wiley & Sons, Inc. J Polym Sci Part A: Polym Chem 39: 3218–3226, 2001  相似文献   

2.
A specific recognition material for bisphenol A (BPA) was prepared by using a covalent imprinting technique. A chloroform solution containing bisphenol A dimethacrylate as a template, ethylene glycol dimethacrylate as a cross-linking agent and 2,2′-azobis(isobutyronitrile) as an initiator was polymerized by UV initiation. When BPA was removed from the resulting polymer by hydrolysis of the ester bonds with aqueous sodium hydroxide, carboxylic acid residues were generated in the polymer. After the polymer was packed into a stainless steel column, retention factors of BPA and related compounds were measured. The imprinted polymer adsorbed BPA and structurally related compounds such as 4,4′-dihydroxybenzophenone, bis(4-hydroxyphenyl)sulfone and 4,4′-dihydroxybiphenyl. A typical association constant (Ka) was calculated to be 1.72×105 M−1 by Scatchard analysis. Interestingly, 17α- and 17β-estradiol were also bound to the imprinted polymer (Ka=1.68×105 M−1), indicating that the polymer could be used as artificial receptors for screening the compounds having estrogenic action.  相似文献   

3.
Proton conductive inorganic–organic hybrid membranes were synthesized from 3-glycidyloxypropyltrimethoxysiane (GPTMS), phenyltriethoxysilane (PhTES) and hydroxyalkylphosphonic acid. Two kinds of hydroxyalkylphosphonic acids, 1-hydroxyethane-1,1-diphosphonic acid (HEDPA) and hydroxyethanephosphonic acid (HEPA), were incorporated into the membranes as functional molecules for proton conduction. FT-IR and Raman studies revealed the presence of phosphonic acid groups in the hybrid membranes. 13C and 29Si NMR confirmed that a three-dimensional siloxane network was formed in the prepared hybrid membrane by hydrolysis and condensation reactions. DTA-TG analysis showed that these membranes were thermally stable up to 200 °C. The HEDPA-based system was found to have higher proton conductivities than the HEPA-based one. The proton conductivities of the hybrid membranes increased with the phosphonic acid content and temperature up to 130 °C. The conductivities of the HEDPA/GPTMS/PhTES membranes = 1/1.6/0.4 were 1.0 × 10−1 and 4.5 × 10−4 S cm−1 at 100% relative humidity and non-humidified conditions, respectively, at 130 °C.  相似文献   

4.
The bisphenol A (BPA) imprinted polymer microspheres were prepared by simple Pickering emulsion polymerization. Compared to traditional bulk polymerization, both high yields of polymer and good control of particle sizes were achieved. The characterization results of scanning electron microscopy and nitrogen adsorption–desorption measurements showed that the obtained molecularly imprinted polymer microsphere (MIPMS) particles possessed regular spherical shape, narrow diameter distribution (30–60 μm), a specific surface area (SBET) of 281.26 m2 g−1 and a total pore volume (Vt) of 0.459 cm3 g−1. Good specific adsorption capacity for BPA was obtained in the sorption experiment and good class selectivity for BPA and its seven structural analogs (bisphenol F, bisphenol B, bisphenol E, bisphenol AF, bisphenol S, bisphenol AP and bisphenol Z) was demonstrated by the chromatographic evaluation experiment. The MIPMS as solid-phase extraction (SPE) packing material was then evaluated for extraction and clean-up of these bisphenols (BPs) from human urine samples. An accurate and sensitive analytical method based on the MIPMS-SPE coupled with HPLC-DAD has been successfully established for simultaneous determination of eight BPs from human urine samples with detection limits of 1.2–2.2 ng mL−1. The recoveries of BPs for urine samples at two spiking levels (100 and 500 ng mL−1 for each BP) were in the range of 81.3–106.7% with RSD values below 8.3%.  相似文献   

5.
A voltammetric procedure in the flow system for determination of traces of Cr(VI) in the presence of Cr(III) and humic acid is presented. The calibration graph is linear from 5×10−10 to 1×10−7 mol l−1 for an accumulation time of 120 s. The R.S.D. for 1×10−8 mol l−1 Cr(VI) is 5.3% (n=5). The detection limit estimated from 3σ for a low concentration of Cr(VI) and accumulation time of 120 s is 2×10−10 mol l−1. The method can be used for Cr(VI) determination in the presence of up to 50 mg l−1 of humic acid. The validation of the method was carried out by studying the recovery of Cr(VI) from spiked river water and by the comparison of the results of determination of Cr(VI) in a soil sample. The method cannot be used for analysis of samples containing high concentrations of chloride ions such as seawater and estuarine water.  相似文献   

6.
In this paper, a method for the determination of four groups of endocrine-disrupting compounds in human hair is proposed. Target compounds were a plastic monomer (bisphenol A), three parabens commonly used as preservatives (methylparaben, ethylparaben and propylparaben), six perfluoroalkyl compounds commonly used as water, oil and dirt repellents (perfluorooctane sulfonic acid and five perfluoroalkyl carboxylic acids, with alkyl chains from four to eight carbon atoms) and a brominated flame retardant (hexabromocyclododecane). All of them are of especial concern to human health because they are utilized in many everyday products. The method is based on hair incubation with methanol/acetic acid solution (85:15, v/v), extraction with acetone for 15 min in an ultrasonic bath and analysis by liquid chromatography-electrospray-tandem mass spectrometry in negative ionization mode. Limits of quantification in hair samples ranged from 0.6 ng g−1 to 6.1 ng g−1, except for hexabromocyclododecane (36 ng g−1). Recoveries were higher than 69%. Intra-day and inter-day precision, expressed as relative standard deviation, were lower than 15% and 10%, respectively. The applicability of the method was proven by analyzing the target compounds in hair samples from six volunteers. High frequencies of detection and concentrations were obtained for bisphenol A (83% of samples; concentrations up to 158 ng g−1) and parabens (100% of samples; concentrations up to 624 ng g−1). Lower concentrations were detected for the perfluoroalkyl compounds (up to 13 ng g−1). Hexabromocyclododecane was not detected.  相似文献   

7.
A biosensor based on the ionic liquid, 1-n-butyl-3-methylimidazolium hexafluorophosphate containing dispersed iridium nanoparticles (Ir-BMI.PF6) and polyphenol oxidase was constructed. This enzyme was obtained from the sugar apple (Annona squamosa), immobilized in chitosan ionically crosslinked with oxalate. The biosensor was used for determination of chlorogenic acid by square wave voltammetry. The polyphenol oxidase catalyzes the oxidation of chlorogenic acid to the corresponding o-quinone, which is electrochemically reduced back to this substance at +0.25 V vs. Ag/AgCl. Under optimized operational conditions the chlorogenic acid concentration was linear in the range of 3.48 × 10−6 to 4.95 × 10−5 mol L−1 with a detection limit of 9.15 × 10−7 mol L−1. The biosensor was applied in the determination of chlorogenic acid in organic and decaffeinated coffee and the results compared with those obtained using the capillary electrophoresis method. The recovery study for chlorogenic acid in these samples gave values of 93.2-105.7%.  相似文献   

8.
Innovative and simultaneous multiresidue analytical methods of 33 multi-class pollutants in wastewaters, surface and ground waters, using solid phase extraction (SPE) followed by gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) are presented. Target compounds include several groups of emerging and persistent contaminants derived from the European priority list of the registration evaluation and authorisation of chemicals system (REACH): organochlorine (8) and organophosphorus (2) pesticides, carbamates (2), fungicides (8), phthalates (2), alkylphenols (10) and bisphenol A.The recovery rates of the SPE gave levels ranged from 84 to 118% with exception of some compounds that yielded lower (methamidophos (50%), p,p′-DDT (60%) and o,p′-DDT (72%)) but all recoveries were acceptable. Low limits of detection (LOD) varied between 0.2 and 88.9 ng L−1 (except for HPTE and 4n-octylphenol giving 161 and 220 ng L−1, respectively). A study of matrix effects was performed in order to evaluate the best and reliable calibration approach.The developed analytical method was successfully applied to the analysis of the 33 substances in wastewater effluents as well as surface and ground waters. The most frequently detected families were alkylphenols and industrial endocrine disrupting compounds (phthalates and bisphenol A).  相似文献   

9.
The effective methylation of phosphonic acids related to chemical warfare agents (CWAs) employing trimethyloxonium tetrafluoroborate (TMO·BF4) for their qualitative detection and identification by gas chromatography-mass spectrometry (GC-MS) is presented. The methylation occurs in rapid fashion (1 h) and can be conveniently carried out at ambient temperature, thus providing a safer alternative to the universally employed diazomethane-based methylation protocols. Optimization of the methylation parameters led us to conclude that methylene chloride was the ideal solvent to carry out the derivatization, and that even though methylated products can be observed surfacing after only 1 h, additional time was not found to be detrimental but beneficial to the process particularly when dealing with analytes at low concentrations (∼10 μg mL−1). Due to its insolubility in methylene chloride, TMO·BF4 conveniently settles to the bottom during the reaction and does not produce additional interfering by-products that may further complicate the GC-MS analysis. The method was demonstrated to successfully methylate a variety of Schedule 2 phosphonic acids, including their half esters, resulting in derivatives that were readily detected and identified using the instrument's spectral library. Most importantly, the method was shown to simultaneously methylate a mixture of the organophosphorus-based nerve agent hydrolysis products: pinacolyl methylphosphonate (PMPA), cyclohexyl methylphosphonate (CyMPA) and ethyl methylphosphonate (EMPA) (at a 10 μg mL−1 concentration each) in a fatty acid ester-rich organic matrix (OPCW-PT-O3) featured in the 38th Organisation for the Prohibition of Chemical Weapons (OPCW) Proficiency Test. In addition, the protocol was found to effectively methylate N,N-diethylamino ethanesulfonic acid and N,N-diisopropylamino ethanesulfonic acid that are products arising from the oxidative degradation of the V-series agents VR and VX respectively. The work described herein represents the first report on the use of TMO·BF4 as a viable, stable and safe agent for the methylation of phosphonic acids and their half esters and within the context of an OPCW Proficiency Test sample analysis.  相似文献   

10.
《Analytica chimica acta》2002,459(2):229-234
The ligand 1,4,8-tri(n-octyl)-1,4,8,11-tetraazacyclotetradecane (L1) containing pendant octyl groups has been synthesised. L1 is a tetraazamacrocycle derived from the well-known cyclam unit, and the Ni2+ and Co2+ complexes, [Ni(L1)]2+ and [Co(L1)]2+, have been isolated and characterised. The ability of the nickel(II) and cobalt(II) complexes to act as anion receptors has been studied by using them as ionophores in membrane-based ion-selective electrodes (ISEs). The PVC membrane containing the complex [Ni(L1)]2+ and 2-nitrophenyloctylether as plasticizer shows a Nernstian response against iodide in a concentration range from 1×10−1 to 4×10−5 M I with a detection limit of 1.6×10−5 M I and a slope of 58.6 mV/pI at pH 7 (25 °C). In comparison, the electrode containing [Co(L1)]2+ as ionophore gave a sub-Nernstian slope and a low lifetime. A comparison between the iodide-selective electrode containing [Ni(L1)]2+ and other reported iodide-selective electrodes is also reported.  相似文献   

11.
A new method for uric acid (UA) determination based on the quenching of the cathodic ECL of the tris(2,2-bipyridine)ruthenium(II)–uricase system is described. The biosensor is based on a double-layer design containing first tris(2,2-bipyridine)ruthenium(II) (Ru(bpy)32+) electrochemically immobilized on graphite screen-printed cells and uricase in chitosan as a second layer. The uric acid biosensing is based on the ECL quenching produced by uric acid over the cathodic ECL caused by immobilized Ru(bpy)32+ in the presence of uricase. The use of a −1.1 V pulse for 1 s with a dwelling time of 10 s makes it possible to estimate the initial enzymatic rate, which is used as the analytical signal. The Stern–Volmer type calibration function shows a dynamic range from 1.0 × 10−5 to 1.0 × 10−3 M with a limit of detection of 3.1 × 10−6 M and an accuracy of 13.6% (1.0 × 10−4 M, n = 5) as relative standard deviation. Satisfactory results were obtained for urine samples, creating an affordable alternative for uric acid determination.  相似文献   

12.
Potentiometric FIA titrations were performed to determine enzyme activities of lipase type B from Candida antarctica, CAL-B. Two substrates, triacetin and tributyrin were hydrolyzed in phosphate buffer solutions, and the concentration change of the base component of the buffer was titrated in a carrier solution containing hydrochloric acid and potassium chloride. The system was calibrated with butyric acid and acetic acid, respectively. FIA titration peaks were evaluated with respect to peak height and peak area. Butyric acid and acetic acid could be titrated in the buffer solution from 3 × 10−3 mol L−1 to 0.1 mol L−1. The detection limit of enzyme activity was determined to be 0.07 U mL−1 (15 min reaction time) and the minimum activity was calculated to be 0.035 units corresponding to 35 nmol min−1. The specific activities of lipase B for the hydrolysis of tributyrin and triacetin were determined as 16 ± 2 U mg−1 and 2 ± 0.2 U mg−1 (per mg commercial lipase preparation), respectively.  相似文献   

13.
A bifurcated optical fiber chemical sensor for continuous monitoring of bisphenol A (BPA) has been proposed based on the fluorescence quenching (λex/λem = 286/390 nm) of pyrene/dimethyl β-cyclodextrin (HDM-β-CD) supramolecular complex immobilized in a plasticized poly(vinyl chloride) (PVC) membrane, in which pyrene served as a sensitive fluorescence indicator probe. The decrease of the fluorescence intensity of pyrene/HDM-β-CD complex upon the addition of BPA was attributed to the displacement of pyrene by BPA, which has been utilized as the basis of the fabrication of a BPA-sensitive fluorescence sensor. The response mechanism of the sensor was discussed in detail. The sensor exhibited a dynamic detection range from 7.90 × 10−8 to 1.66 × 10−5 mol L−1 with a detection limit of 7.00 × 10−8 mol L−1, and showed excellent reproducibility, reversibility, selectivity, and lifetime. The proposed sensor was successfully used for the determination of BPA in water samples and landfill leachate.  相似文献   

14.
A highly sensitive flow-injection (FI) method with chemiluminescence (CL) detection is used for the determination of l-ascorbic acid. The method is based on the CL reaction of Rhodamine B with cerium(IV) in sulfuric acid media. l-Ascorbic acid is suggested to be a catalyst utilized in the energy-transferred excitation process. The proposed procedure allows quantitation of l-ascorbic acid in the range 3.8×10−13 to 1.0×10−10 mol l−1 with a correlation coefficient of 0.9998 (n=5) and relative standard deviation (R.S.D.) of 0.92% (n=11) at 1.0×10−11 mol l−1. The detection limit (3×blank) was 1.0×10−13 mol l−1. The method is successfully used to determine l-ascorbic acid in fresh vegetables. The possible mechanism of the chemiluminescence in the system is discussed.  相似文献   

15.
For polymer electrolyte membrane fuel membrane cell (PEMFC) applications, the effect of electron-withdrawing groups on the properties of sulfonated poly(arylene ether) (SPE) ionomer membranes was investigated. A series of poly(arylene ether)s containing fluorenyl groups and electron-withdrawing groups (sulfone, nitrile, or fluorine) was synthesized, which were sulfonated with chlorosulfonic acid using a flow reactor to obtain the title ionomers. The ionomers had high molecular weight (M> 77 kDa, Mw > 238 kDa) and gave tough, ductile membranes by solution casting. The ion exchange capacity (IEC) of the membranes ranged from 1.6 to 3.5 mequiv/g as determined by titration. The electron-withdrawing groups did not appear to affect the thermal properties (decomposition temperature higher than 200 °C). The presence of nitrile groups, especially at positions meta to the ether linkages, improved the oxidative stability of the SPE membranes, while it led to a deterioration of the hydrolytic stability. The perfluorinated biphenylene groups were effective in providing high mechanical strength with reasonable dimensional change, probably due to a somewhat decreased water absorbability. The SPE membrane containing sulfone groups showed the highest proton conductivity (10−3-10−1 S/cm) at 20-93% RH (relative humidity) and 80 °C. The nitrile-containing SPE membrane showed smaller apparent activation energies for oxygen and hydrogen permeability and is thus considered to be a possible candidate for applications in PEMFCs.  相似文献   

16.
A novel chemiluminescence (CL) microfluidic system incorporating a molecularly imprinted polymer (MIP) preconcentration step was used for the determination of chloramphenicol in honey samples. The MIP was prepared by using chloramphenicol as the template, diethylaminoethyl methacrylate (DAM) as the function monomer, ethylene glycol dimethacrylate (EGDMA) as the cross-linking monomer, 2, 2′-dimethoxy-2-phenylacetophenone (DMPA) as the free radical initiator and toluene and dodecanol as the solvent. The MIP was pre-loaded into a 10 mm long, 2 mm wide and 150 μm deep channel in a planar glass microfluidic device. When the sample containing chloramphenicol was introduced into the microfluidic device it was first preconcentrated on the MIP then detected by an enhancement effect on the chemiluminescence reaction of tris(2, 2′-bipyridyl) ruthenium(II) with cerium(IV) sulphate in sulphuric acid. A micro-syringe pump was used to pump the reagents. The CL intensity was linear in relationship to the chloramphenicol concentrations from 1.55 × 10−4 to 3.09 × 10−3 μmol L−1 (r2 = 0.9915) and the detection limit (3σ) and the quantitation limit (10σ) were found to be 7.46 × 10−6 and 2.48 × 10−5 μmol L−1, respectively. This method offered a high selectivity and sensitivity for quantitative analysis of chloramphenicol in the honey samples.  相似文献   

17.
Terbium sensitized fluorescence was used as a post-column detection system to develop a simple, sensitive and rapid high-performance liquid chromatographic method for the simultaneous determination of catecholamines norepinephrine (NE), epinephrine (E) and dopamine (DA).Catecholamines were separated by an ion-pair reversed-phase chromatography on a BDS-Hypersil analytical column with a mobile phase of methanol and 50 mmol l−1 acetate buffer (pH 4.7) containing 1.1 mmol l−1 SOS and 0.11 mmol l−1 EDTA (15+85 v/v).Catecholamines and the internal standard (3,4-dihydroxybenzylamine, DHBA) were post-column derivatized by the addition to the eluent of an alkaline solution containing a stoichiometric mixture of terbium(III) chloride and EDTA. Fluorescence detection (λex=300 nm, λem=545 nm) is based on the sensitization of terbium ion fluorescence after complexation with catecholamines.The chemical compatibility between the eluent and the post-column reagent was studied and the analytical characteristics of the method were established. Detection limits found were 1.0×10−8, 4.0×10−8 and 7.0×10−8 mol l−1 for NE, E and DA, respectively. The method has been successfully applied to the determination of catecholamines in urine samples after solid-phase extraction (SPE) pre-treatment. Recoveries from urine spiked with NE (4.0×10−7, 2.0×10−6 and 4.0×10−6 mol l−1), E (8.2×10−8, 4.1×10−7 and 8.2×10−7 mol l−1) and DA (1.0×10−6, 5.0×10−6 and 1.0×10−5 mol l−1) varied from 98 to 100% (mean=99.3%), from 106 to 107% (mean=106.3%) and from 98 to 101% (mean=99.3%), respectively. The between-run precision (relative standard deviation, R.S.D.) for the method for three urine samples at different concentration levels of each catecholamine varied from 3.6 to 7.0%.  相似文献   

18.
The immobilization of tyrosinase onto glutaraldehyde activated streptavidine magnetic particles and subsequent retention onto a magnetized carbon paste electrode for the amperometric assay of tyrosinase inhibitors is described. Tyrosine was used as substrate as it is the first substrate in the melanogenesis process. The sensing mode is based on monitoring the decrease of the amperometric signal corresponding to the electrochemical reduction of dopaquinone enzymatically generated. This current decrease is due to the presence of inhibitors acting directly on the enzyme or inhibitors acting on the product of the enzymatic reaction, i.e. dopaquinone. The methodology is designed for the evaluation of the inhibitory potency of the most frequently used active substances in cosmetic marketed products against hyperpigmentation such as kojic acid, azelaic acid and benzoic acid. These compounds bind to the tyrosinase active center. Ascorbic acid is also investigated as it interrupts the synthesis pathway of melanin by reducing the melanin intermediate dopaquinone back to l-dopa. By comparing the obtained IC50, under the same experimental conditions, the order of their inhibitory potency was: kojic acid (IC50 = 3.7 × 10−6 M, Ki = 8.6 × 10−7 M), ascorbic acid (IC50 = 1.2 × 10−5 M), benzoic acid (IC50 = 7.2 × 10−5 M, Ki = 2.0 × 10−5 M) and azelaic acid (IC50 = 1.3 × 10−4 M, Ki = 4.2 × 10−5 M) in close agreement with literature spectrophotometric inhibition data using the soluble tyrosinase.  相似文献   

19.
The dependence of Th recovery on hydrofluoric acid (HF) concentration in nitric acid (HNO3) solutions (1–5 mol/dm3) containing 1 × 10−6 mol/dm3 of Th and various concentrations of HF and the elution behavior were studied using a commercially available UTEVA (for uranium and tetravalent actinide) resin column. Thorium recovery decreased with an increase in HF concentration in the sample solutions. The concentration of HF at which Th recovery started to decrease was ∼1 × 10−4 mol/dm3 in 1 mol/dm3 HNO3 solution, ∼1 × 10−3 mol/dm3 in 3 mol/dm3 HNO3 solution, and ∼1 × 10−2 mol/dm3 in 5 mol/dm3 HNO3 solution. When Al(NO3)3 (0.2 mol/dm3) or Fe(NO3)3 (0.6 mol/dm3) was added as a masking agent for F to the Th solution containing 1 × 10−1 mol/dm3 HF and 1 mol/dm3 HNO3, Th recovery improved from 1.4 ± 0.3% to 95 ± 5% or 93 ± 3%. Effective extraction of Th using UTEVA resin was achieved by selecting the concentration of HNO3 and/or adding masking agents such as Al(NO3)3 according to the concentration of HF in the sample solution.  相似文献   

20.
Numerous drugs are carboxylic acid derivatives containing amino group, and hydrolysis reaction of these agents often generates toxic amines. Thus, the detection of amine impurity is of great importance in drug quality control of these amino group-containing ester and amide. A capillary electrophoresis method coupled with end-column electrochemiluminescent detection based on tris(2,2′-bipyridyl)ruthenium(II) system was proposed for the analysis of N,N-dimethyl ethanolamine (DMEA, the degradation product of meclophenoxate) in the presence of its precursor. Baseline separation of DMEA and meclophenoxate can be easily achieved under the selected conditions. DMEA can be assayed within 3 min over the concentration range of 5.0 × 10−8 to 3.0 × 10−6 mol L−1 with a detection limit of 2.0 × 10−8 mol L−1 at the signal-to-noise ratio of 3. The relative standard deviations of the signal intensity and the migration time were less than 5.3 and 2.5% for a standard sample containing 1.0 × 10−7 mol L−1 DMEA (n = 5), respectively. The presented method has been successfully applied for the profiling of DMEA resulting from the hydrolysis of meclophenoxate in commercial formulations. A primary stability investigation of meclophenoxate in aqueous solution was also carried out at different temperatures, and the results showed that the degradation of meclophenoxate accelerated at the higher temperature.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号