首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
A planar differential mobility spectrometer (DMS) was coupled to a Mini 10 handheld rectilinear ion trap (RIT) mass spectrometer (MS) (total weight 10 kg), and the performance of the instrument was evaluated using illicit drug analysis. Coupling of DMS (which requires a continuous flow of drift gas) with a miniature MS (which operates best using sample introduction via a discontinuous atmospheric pressure interface, DAPI), was achieved with auxiliary pumping using a 5 L/min miniature diaphragm sample pump placed between the two devices. On-line ion mobility filtering showed to be advantageous in reducing the background chemical noise in the analysis of the psychotropic drug diazepam in urine using nanoelectrospray ionization. The combination of a miniature mass spectrometer with simple and rapid gas-phase ion separation by DMS allowed the characteristic fragmentation pattern of diazepam to be distinguished in a simple urine extract at lower limits of detection (50 ng/mL) than that achieved without DMS (200 ng/mL). The additional separation power of DMS facilitated the identification of two drugs of similar molecular weight, morphine (average MW = 285.34) and diazepam (average MW = 284.70), using a miniature mass spectrometer capable of unit resolution. The similarity in the proton affinities of these two compounds resulted in some cross-interference in the MS data due to facile ionization of the neutral form of the compound even when the ionic form had been separated by DMS.  相似文献   

2.
The effects of flow rate and column length on analyte response (peak area and height), total cycle time, column backpressure, and elution volume are presented. Rapid chromatographic separations and tandem mass spectrometric (MS/MS) detection are applied to the supernatant of protein-precipitated plasma standards containing four compounds from a drug discovery screen. The plasma samples were injected onto three C-18 columns (2 x 10,2.1 x 30 and 2.1 x 50 mm) at flow rates of 0.25, 0.50, 1.00 and 1.50 mL/min. The plasma samples were detected using a Sciex API 3000 tandem mass spectrometer operated in the Turbo Ionspray mode. A post-column split was used to maintain a flow rate of 0.25 mL/min into the mass spectrometer source to avoid differences in nebulization efficiency. The data show that diluted protein-precipitated plasma supernatants show average matrix effects (i.e. suppression) of 60.0% (2 x 10 mm), 89.3% (2 x 30 mm), and 76.7% (2 x 50 mm) of expected response at 10 ng/mL. Average matrix effects of 70.2% (2 x 10 mm), 88.9% (2 x 30 mm), and 81.2% (2 x 50 mm) of expected response at 1000 ng/mL plasma. The data also show if peak widths remain relatively constant, analytes are less sensitive as flow rates are increased. These data are consistent with the concentration-dependent relationship of ionspray in the range of flow rates studied. The data show that, while analyte response decreased proportionately to increases in flow rate, the analysis cycle times did not decrease proportionately.  相似文献   

3.
We report a new hybrid mass spectrometer, which is a combination of a quadrupole ion trap and an orthogonal time-of-flight (TOF) mass spectrometer. This new configuration consists of a collisional-damping chamber (CDC) inserted between an MSn-capable ion trap and a high-mass-accuracy orthogonal-TOF mass spectrometer. Because the CDC converted an ion packet into an energy-focused and quasi-continuous beam, a high mass resolution of over 10,000 and a high mass accuracy of better than 3 ppm were achieved. Moreover, the ratio of the maximum detectable m/z to the minimum detectable m/z, which is referred to here as the mass window, was improved to more than 10.  相似文献   

4.
An ion mobility spectrometer that can easily be installed as an intermediate component between a commercial triple-quadrupole mass spectrometer and its original atmospheric pressure ionization (API) sources was developed. The curtain gas from the mass spectrometer is also used as the ion mobility spectrometer drift gas. The design of the ion mobility spectrometer allows reasonably fast installation (about 1 h), and thus the ion mobility spectrometer can be considered as an accessory of the mass spectrometer. The ion mobility spectrometer module can also be used as an independently operated device when equipped with a Faraday cup detector. The drift tube of the ion mobility spectrometer module consists of inlet, desolvation, drift, and extraction regions. The desolvation, drift and extraction regions are separated by ion gates. The inlet region has the shape of a stainless steel cup equipped with a small orifice. Ion mobility spectrometer drift gas is introduced through a curtain gas line from an original flange of the mass spectrometer. After passing through the drift tube, the drift gas serves as a curtain gas for the ion-sampling orifice of the ion mobility spectrometer before entering the ion source. Counterflow of the drift gas improves evaporation of the solvent from the electrosprayed sample. Drift gas is pumped away from the ion source through the original exhaust orifice of the ion source. Initial characterization of the ion mobility spectrometer device includes determination of resolving power values for a selected set of test compounds, separation of a simple mixture, and comparison of the sensitivity of the electrospray ionization ion mobility spectrometry/mass spectrometry (ESI-IMS/MS) mode with that of the ESI-MS mode. A resolving power of 80 was measured for 2,6-di-tert-butylpyridine in a 333 V/cm drift field at room temperature and with a 0.2 ms ion gate opening time. The resolving power was shown to be dependent on drift gas flow rate for all studied ion gate opening times. Resolving power improved as the drift gas flow increased, e.g. at a 0.5 ms gate opening time, a resolving power of 31 was obtained with a 0.65 L/min flow rate and 47 with a 1.3 L/min flow rate for tetrabutylammonium iodide. The measured limits of detection with ESI-MS and with ESI-IMS/MS modes were similar, demonstrating that signal losses in the IMS device are minimal when it is operated in a continuous flow mode. Based on these preliminary results, the IMS/MS instrument is anticipated to have potential for fast screening analysis that can be applied, for example, in environmental and drug analysis.  相似文献   

5.
Direct spectroscopy of a fast molecular ion beam offers many advantages over competing techniques, including the generality of the approach to any molecular ion, the complete elimination of spectral confusion due to neutral molecules, and the mass identification of individual spectral lines. The major challenge is the intrinsic weakness of absorption or dispersion signals resulting from the relatively low number density of ions in the beam. Direct spectroscopy of an ion beam was pioneered by Saykally and co-workers in the late 1980s, but has not been attempted since that time. Here, we present the design and construction of an ion beam spectrometer with several improvements over the Saykally design. The ion beam and its characterization have been improved by adopting recent advances in electrostatic optics, along with a time-of-flight mass spectrometer that can be used simultaneously with optical spectroscopy. As a proof of concept, a noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS) setup with a noise equivalent absorption of ~2 × 10(-11) cm(-1) Hz(-1/2) has been used to observe several transitions of the Meinel 1-0 band of N(2) (+) with linewidths of ~120 MHz. An optical frequency comb has been used for absolute frequency calibration of transition frequencies to within ~8 MHz. This work represents the first direct spectroscopy of an electronic transition in an ion beam, and also represents a major step toward the development of routine infrared spectroscopy of rotationally cooled molecular ions.  相似文献   

6.
Photodissociation of H+2 and D+2 has been observed in a crossed beam experiment. A laser used as photon source. The ion and laser beam cross each other inside the laser cavity. The momentum spectra of the resulting H+ or D+ fragments are recorded with a mass spectrometer. From the spectra the excess kinetic energy is calculated. These values agree with the theoretically expected ones within the experimental error. From the measured intensity distribution the relative population for several vibrational states in the primary ion beam is calculated. Our values deviate from the usual assumed Franck-Condon pattern as well as from the values reported by Dunn. The angular dependence of the fragments is also measured. This dependence indicates a polarization of the primary beam perpendicular to its direction.  相似文献   

7.
Mass spectra of doubly charged mercury clusters (m/z=30-1065) were investigated by secondary ion mass spectrometry. Positively charged ions were generated from an amalgam of mercury and silver by bombardment with a xenon ion beam and mass analysis by a grand-scale sector type mass spectrometer. Hg n 2+, n=1-10 and Hg n +, n =1- 5 were observed. Some doubly charged mercury clusters, (Hg n 2+) survived at least for 0.1 ms.  相似文献   

8.
Electrospray ionization for analysis of platelet-activating factor.   总被引:1,自引:0,他引:1  
Platelet-activating factor (PAF) was analyzed by electrospray-ionization mass spectrometry (ESI-MS) using a single quadrupole mass spectrometer. The positive-ion spectrum was dominated by an ion corresponding to a sodiated molecule when a low potential difference between the capillary exit (nozzle) and the skimmer was employed, but when the capillary exit voltage was increased, fragmentation of PAF was observed. Initial fragmentation involved the loss of the elements of trimethylamine from the sodiated molecule to yield [M+Na-59]+. An intense ion at m/z 147, generated by the loss of trimethylamine from the sodiated phosphocholine portion of the molecule was also detected, along with a lower intensity ion at m/z 184 which is representative of a protonated phosphocholine moiety. With negative-ion detection the major molecular species was [M+Cl]-. Interpretation of the mass spectral fragments was verified by ESI tandem mass spectrometry on a triple-quadrupole tandem mass spectrometer.  相似文献   

9.
Super‐atmospheric pressure chemical ionization (APCI) mass spectrometry was performed using a commercial mass spectrometer by pressurizing the ion source with compressed air up to 7 atm. Similar to typical APCI source, reactant ions in the experiment were generated with corona discharge using a needle electrode. Although a higher needle potential was necessary to initiate the corona discharge, discharge current and detected ion signal were stable at all tested pressures. A Roots booster pump with variable pumping speed was installed between the evacuation port of the mass spectrometer and the original rough pumps to maintain a same pressure in the first pumping stage of the mass spectrometer regardless of ion source pressure. Measurement of gaseous methamphetamine and research department explosive showed an increase in ion intensity with the ion source pressure until an optimum pressure at around 4–5 atm. Beyond 5 atm, the ion intensity decreased with further increase of pressure, likely due to greater ion losses inside the ion transport capillary. For benzene, it was found that besides molecular ion and protonated species, ion due to [M + 2H]+ which was not so common in APCI, was also observed with high ion abundance under super‐atmospheric pressure condition. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

10.
A new gas chromatography/mass spectrometry (GC/MS) system was designed and evaluated which we have named 'Supersonic GC/MS'. It is based on a modification of a commercially available GC/MS system to include a supersonic molecular beam (SMB) MS interface. In this system the standard electron ionization (EI) ion source was replaced with a fly-through EI ion source mounted in the path of the SMB. A hyperthermal surface ionization (HSI) ion source combined with a 90 degrees ion mirror (for the EI-produced ions) was also added, and placed inside the quadrupole mass analyzer in place of its original EI ion source. The 'Supersonic GC/MS' system requires 18 cm added bench space plus the addition of an air-cooled 60 L/s diffusion pump and a 537 L/min rotary pump. The system is user friendly since all the gas flow rates, heated zones, sampling and data analysis are performed the same way as the original system and are computer-controlled via the original software. Similar EI sensitivity was obtained as with the original system for hexachlorobenzene and octafluoronaphthalene, while improved EI detection limits were demonstrated for methyl stearate and eicosane due to the significant enhancement of their molecular ion abundances. A GC/MS detection limit of 500 ag for pyrene was demonstrated using HSI. Good supersonic expansion cooling was achieved with large alkanes, despite the use of a rotary pump at the nozzle chamber instead of a diffusion pump. High temperature GC/MS analysis was demonstrated for large polycyclic aromatic hydrocarbons (PAHs) including ovalene and decacyclene (ten rings). Library searches with EI mass spectra are demonstrated, and it is explained why the enhancement of the molecular ion actually improves the library search in most cases. The analysis of large phthalate esters is also described, and the improvement obtained is shown to originate from their enhanced molecular and high mass fragment ions.  相似文献   

11.
12.
Accurate quantitation has been demonstrated on many different types of mass spectrometer. However, quantitative applications of Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) have been limited. In this study, the quantitative potential of FTICRMS has been investigated using an exact matching isotope dilution method for the determination of creatinine in serum. Creatinine is an important clinical biomarker and its measurement is used as an assessment of renal function. The quantitation of creatinine was selected because a high-accuracy high-performance liquid chromatography/mass spectrometry (HPLC/MS) determination using a triple quadrupole mass spectrometer has already been successfully developed in-house. Therefore, a direct comparison of the quantitative capability of FTICRMS could be made against an established method. The accuracy of the quantitation of creatinine was found to be equivalent to that obtained using LC/MS. However, the expanded measurement uncertainty (k = 2) was larger, at 6%, when using FTICRMS compared with 1% when using HPLC/MS with the triple quadrupole mass spectrometer.  相似文献   

13.
Azithromycin is a broad spectrum antimicrobial agent that is approved in the United States for use in humans. Due to azithromycin's low rate of metabolism it is likely to be found in wastewater treatment plants, where its broad spectrum of antimicrobial activity could lead to development of resistance in bacteria. A liquid-liquid extraction using K2CO3 and methyl-t-butyl ether (MTBE) was used to extract azithromycin from 10 ml aliquots of wastewater. Liquid chromatography was performed using a Luna C18(2) (30 mm x 2.0 mm) column with a mass spectrometer friendly mobile phase containing 50:24:2:24 acetonitrile, methanol, tetrahydrofuran, and 0.04 M ammonium hydroxide. The mass spectrometer used an electrospray source with positive ionization and an ion trap detector. A linear standard curve from 5 to 200pg/ml was validated and used to quantitate azithromycin in wastewater.  相似文献   

14.
Trace level vanadium determination is reported using a dual beam thermal lens spectrometer. The thermal lens was generated using an argon ion beam laser (pump beam) which was focused into a sample cuvette. The thermal lens signal (TLs) was monitored with a He-Ne laser beam and a photodiode detector. Multichannel averager software was developed for processing the transient TLs. The optimal set up, ensuring maximum sensitivity and linear calibration graphs was obtained using experimental design techniques. Under optimized conditions, the detection limits for aqueous and ethanol-water (2+3 v/v) and (4+1 v/v) vanadium complex solutions were, respectively, 0.0071 mg/l, 0.0065 and 0.0039 mg/l.  相似文献   

15.
介绍了最新推出的全谱同时检测的电感耦合等离子体质谱(ICP-MS)仪器,它是目前市场上唯一的从6Li到238U质量范围同时测量的ICP质谱仪,实现了从时序扫描测量到全谱同时测量的新飞跃.其革命性技术的核心是双聚焦扇形场质谱仪与全新的能够同时俘获全部离子的检测器及其创新设计的离子透镜系统,展现出优越的性能和更广阔的应用前...  相似文献   

16.
An ion trap/time-of-flight (IT/TOF) mass spectrometer was developed and applied to infrared multiphoton dissociation (IRMPD) studies of ions generated by electrospray ionization. A pulsed 10.6- micro m laser beam from a CO(2) laser was used for excitation of trapped ions. Results from IRMPD of peptide ions show that this method provides useful information related to the amino acid sequence of analyzed peptides. Comparative studies show that IRMPD spectra are similar to those obtained using a 266-nm UV laser beam for excitation. However, in contrast to multiple-pulse excitation required at 266 nm, the energy of a single laser pulse in IRMPD is sufficient to induce dissociation of peptide ions. The laser power is practically an exclusive parameter that must be controlled in order to obtain IRMPD spectra that will provide the optimal structural information. It is further demonstrated that the IRMPD IT/TOF technique has the potential to probe the structural features of larger ions that cannot be readily fragmented by collision-induced dissociation (CID). A multiply charged ion of equine cytochrome c is successfully fragmented in a single laser pulse experiment. The IRMPD IT/TOF technique is also shown to be a promising tool for studying dissociation kinetics of peptide and protein ions. Unlike other methods that usually monitor the dissociation ion kinetics in a dissociation time frame of greater than milliseconds, the IT/TOF can promptly detect all product ions generated by the dissociation process, and thus monitor the dissociation process of peptides and proteins in a sub-millisecond time frame. This instrument allows us to determine the dissociation rates of cytochrome c ions using high-energy photoexcitation. It is found that the charge state of the protein ion has a significant effect on dissociation kinetics, which is consistent with that found under low-energy excitation experiments. It is shown that the increase in energy of a laser pulse from 130 to 180 mJ changes the dissociation rate constant for the +12 ion from k = 2.4 x 10(3) x s(-1) to k = 7.3 x 10(4) x s(-1). The +8 ion following excitation at 130 mJ dissociates slower with a rate constant of k = 2.6 x 10(2) x s(-1). The rate difference observed is attributed to conformational differences among the ions with different charge states.  相似文献   

17.
Trapping of ions in the electron beam of a FTICR mass spectrometer is investigated and a simple model describing the confinement process is presented. Detection of resistive-wall destabilization of the magnetron motion of ions in the trapped-ion cell is used to determine conditions for ion trapping within and escape from the electron beam. The model predicts a potential well that is dependent on electron beam current, energy, and dimension in defining its capacity for low energy ions. Plots of ion retention time versus ion number are consistent with a model in which ions are initially trapped in the electron beam but with increasing ion formation will eventually overcome the potential depression in the electron beam and escape into magnetron orbits. Based upon this model, expressions are derived for ion retention time which are then fit to the experimental data. The model is used to estimate ion number, initial magnetron radius and ion cloud shape and density. One example in which electron trapping is important in the FTICR experiment is in the efficient transfer of ions between dual trapped-ion cells. Ion transfer within the potential depression of the electron beam environment is shown to be virtually 100% efficient over a 10 ms interval whereas all ions are lost to collisions with the conductance limit after 2 ms when transferring without the confining aid of the electron beam. Several analytical applications of electron traps in the ICR cell are now being investigated.  相似文献   

18.
An inexpensive multisample fast-atom bombardment (FAB) probe assembly was designed for high-throughput analysis of samples on a VG ZAB-SE mass spectrometer. The system consists of a vacuum lock system and a FAB probe whose tip contains five or more sample wells. The probe enters the mass spectrometer source region perpendicular to the secondary ion beam axis, The probe is maintained at high voltage on contact with a spring clip attached to the screen plate of the source block. Sample throughput with the multisample probe is twice that of a coaxial probe, with about twice the sensitivity and no sample cross contamination.  相似文献   

19.
A simple ion trap/ion mobility/time-of-flight (TOF) mass spectrometer has been coupled with nanoflow liquid chromatography to examine the feasibility of analyzing mixtures of intact proteins. In this approach proteins are separated using reversed-phase chromatography. As components elute from the column, they are electrosprayed into the gas phase and separated again in a drift tube prior to being dispersed and analyzed in a TOF mass spectrometer. The mobilities of ions through a buffer gas depend upon their collision cross sections and charge states; separation based on these gas-phase parameters provides a new means of simplifying mass spectra and characterizing mixtures. Additionally it is possible to induce dissociation at the exit of the drift tube and examine the fragmentation patterns of specific protein ion charge states and conformations. The approach is demonstrated by examining a simple three-component mixture containing ubiquitin, cytochrome c, and myoglobin and several larger prepared protein mixtures. The potential of this approach for use in proteomic applications is considered.  相似文献   

20.
Presented is the application and evaluation of a magnetic field focusing central trapping electrode ion accumulation cell for a capillary liquid chromatography electrospray Fourier transform ion cyclotron (LC-ESI/FTICR) mass spectrometer. The ESI source and accumulation cell are located within the magnetic field to confine the radial motion of the ions, eliminating the need for elaborate focusing optics to transport the ions to the low-pressure analyzer cell for analysis. The central trapping electrode accumulation cell increases sensitivity by providing the necessary potential well in a confined volume to capture ions currently lost during the detection event of LC/FTICR experiments. With this electrode geometry the time needed to gate the ions into the analyzer cell is reduced and pump down delays are minimized. The decreased scan time improves LC resolution and increases the number of mass spectral scans per eluted component while maintaining appropriate base pressures for high performance ESI/FTICR. Results achieved with the central trapping electrode accumulation cell include an effective duty cycle increase from 10% to 40%, a S/N increase by a factor of 30, and a mass resolution increase of 80%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号