首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
He L  Zhang K  Wang C  Luo X  Zhang S 《Journal of chromatography. A》2011,1218(23):3595-3600
An ionic liquid dispersive liquid–liquid microextraction high-performance liquid chromatography (IL-DLLME-HPLC) method for effective enrichment and determination of nitrite ion in water and biological samples was developed. The method was based on the reaction of nitrite ion with p-nitroaniline in the presence of diphenylamine in acid media and IL-DLLME of azo product. The optimization of reaction and extraction conditions, such as kind and concentration of acid, reaction time, volume of reaction solvent, temperature, kind of extraction and dispersive solvent, volume of extraction and dispersive solvent, addition of salt, extraction and centrifugal time were studied. Under the optimal conditions, 1-octyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide IL-DLLME procedure provided high enrichment factor of 430 and good extraction recovery of 91.7% for nitrite ion. The linearity was observed in the range of 0.4–500.0 μg L−1 with good correlation coefficient (r2 = 0.9996). The relative standard deviations (RSDs) for five replicate measurements varied between 1.5% and 4.8%. The limit of detection of the method (S/N = 3) was 0.05 μg L−1. The interference effect of some anions and cations was also tested. The developed method allowed achieving an excellent enrichment factor, yielding a lower LOD in comparison with other methods. Moreover, the proposed method was able to analyze nitrite ion in water and biological samples with satisfactory recovery ranged from 96.5% to 107.3%.  相似文献   

2.
Ren R  Wang Y  Zhang R  Gao S  Zhang H  Yu A 《Talanta》2011,83(5):6259-1400
A new method was developed for the determination of monolinuron, propazine, linuron, and prebane in environmental water samples. The solvent (ionic liquid) impregnated resin (IL-SIR)-based extraction coupled with dynamic ultrasonic desorption (DUSD) was applied to the separation and concentration of the analytes. The high performance liquid chromatography (HPLC) was applied to the determination of the analytes. The ionic liquid [C6MIM][PF6] was immobilized on Diaion HP20 resin by immersing the resin in ethanol solution containing [C6MIM][PF6]. The effect of extraction parameters, including pH value of sample solution, salt concentration in sample and extraction time, and elution conditions, including the concentration of ethanol in elution solvent, the flow rate of elution solvent and the ultrasonic power, were examined and optimized. The limits of detection and quantification for the analytes were in the range of 0.15-0.29 μg L−1 and 0.51-0.98 μg L−1, respectively. Some environmental water samples were analyzed and the analytical results were satisfactory.  相似文献   

3.
A fast, simple and environmentally friendly ultrasound-assisted dispersive liquid–liquid microextraction (USADLLME) procedure has been developed to preconcentrate geosmin and 2-methylisoborneol (MIB) from water and wine samples prior to quantification by gas chromatography–mass spectrometry (GC–MS). A two-stage multivariate optimization approach was developed by means of a Plackett–Burman design for screening and selecting the significant variables involved in the USADLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were: solvent volume, 8 μL; solvent type: tetrachloroethylene; sample volume, 12 mL; centrifugation speed, 2300 rpm; extraction temperature 20 °C; extraction time, 3 min; and centrifugation time, 3 min. Under the optimized experimental conditions the method gave good levels of repeatability with coefficient of variation under 11% (n = 10). Limits of detection were 2 and 9 ng L−1 for geosmin and MIB, respectively. Calculated calibration curves gave high levels of linearity with correlation coefficient values of 0.9988 and 0.9994 for geosmin and MIB, respectively. Finally, the proposed method was applied to the analysis of two water (reservoir and tap) samples and three wine (red, rose and white) samples. The samples were previously analyzed and confirmed free of target analytes. Recovery values ranged between 70 and 113% at two spiking levels (0.25 μg L−1 and 30 ng L−1) showing that the matrix had a negligible effect upon extraction. Only red wine showed a noticeable matrix effect (70–72% recovery). Similar conclusions have been obtained from an uncertainty budget evaluation study.  相似文献   

4.
A new sampling method was developed to collect vapor-phase polycyclic aromatic compounds (PAHs) downstream of a diesel engine equipped with a diesel particulate filter (DPF). This configuration allowed us to collect separately the particulate phase, which was trapped inside the DPF, and the vapor phase, which was sampled downstream of the DPF. PAHs, which were not predominantly absorbed into the poor organic fraction of the diesel soot, but were rather physically sorbed on high energetic adsorption sites, should be extracted using very drastic extraction conditions Microwave-assisted extraction using solvent mixtures composed of pyridine and diethylamine were used to desorb particulate PAHs, and the total PAH amounts corresponded to a very low value, i.e., 8 μg g−1 or 0.24 μg km−1, with a predominance of low weight PAHs. For collection of the vapor phase, gas bubbling in an aqueous medium was preferred to conventional methods, e.g., trapping on solid sorbents, for several reasons: aqueous trapping allowed us to use a solid phase enrichment process (SPE) that permitted PAH sampling at the sub-picogram levels. Consequently, low volume sampling was possible even if the sampling duration was very short (20 min). Additionally, the amount of time saved for the analysis was considerable when coupling SPE to the analytical system (liquid chromatography with fluorimetric detection). Solvent consumption for the overall sampling and analytical processes was also drastically reduced. Experiments on a diesel engine showed that vapor phase samples collected downstream of the DPF contained all of the 15 target priority PAHs, even the heaviest ones. The total vapor-phase PAH amount was 6.88 μg N m−3 or 10.02 μg km−1, which showed that the gaseous fraction contains more PAHs than the particulate fraction. Partitioning coefficients (Kp) were estimated showing the predominance in the vapor phase of all the PAHs. However, the DPF technology effects a considerable decrease in the total PAH emission when compared to non-equipped diesel vehicles.  相似文献   

5.
The bottleneck of applying stir bar sorptive extraction (SBSE) to elemental speciation analysis is lack of suitable extraction phases with good affinities to different elemental species. In this paper, a newly high polar extraction phase of titania immobilized polypropylene hollow fiber (TiO2-PPHF) was prepared by sol–gel immersion and low temperature hydrothermal process and the obtained TiO2-PPHF inherits the adsorption properties of TiO2 and the toughness of PPHF. With a suitable size of stainless steel magnetic bar inserted into the prepared TiO2-PPHF, a disposable TiO2-PPHF coating stir bar was obtained. The prepared TiO2-PPHF was characterized by X-ray diffraction spectrometry and scanning electron microscopy and the significant parameters affecting the extraction efficiency of different arsenic species were studied. Based on the above facts, a new method of SBSE combined with high performance liquid chromatography (HPLC)–inductively coupled plasma mass spectrometry (ICP-MS) was developed for the speciation of phenyl arsenic compounds and their possible transformation products in chicken tissues. Under the optimal conditions, limits of detection (LODs) of the developed method for eight target arsenic species were in the range of 11.4–64.6 ng L−1 with enrichment factors of 8.5–22.3 (theory enrichment factor was 50), and the relative standard deviations (RSDs) were varying from 6.3 to 12.6% (cAsIII/V = 5 μg L−1, cMMA,DMA,p-ASA,4-OH,3-NHPAA,PA,4-NPAA = 10 μg L−1, n = 7). The proposed method was successfully applied to the speciation of arsenic in chicken meat/liver samples and the recoveries for the spiked samples were in the range of 78.5–120.4%. In order to validate the accuracy of the proposed method, a certified reference material of BCR-627 tuna fish tissue was analyzed and the determined values were in good agreement with the certified values. The TiO2-PPHF was demonstrated to be a highly selective coating for the target arsenic species, and could be easily prepared in batches with low cost. In addition, with the disposable coating, the carry-over effect commonly encountered in conventional SBSE was avoided.  相似文献   

6.
Wei R  Li W  Yang L  Jiang Y  Xie T 《Talanta》2011,83(5):334-1490
A sensitive method of online preconcentration followed by capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-C4D) is evaluated as a novel approach for the determination of benzoic acid and sorbic acid in soy sauce. The online preconcentration technique, namely field-enhanced sample injection, coupled with CE-C4D were successfully developed and optimized. In order to reduce the complex matrix interference resulting from the constituents of soy sauce, a suitable sample clean-up procedure was also investigated for real sample pretreatment. Under optimized conditions, sorbic acid and benzoic acid were well separated within 10 min, and the detection limits were 0.05 μM (5.6 μg L−1) and 0.08 μM (9.8 μg L−1), respectively. The accuracy was tested by spiking 10.0 mg L−1 and 100.0 mg L−1 of standards in the soy sauce samples, and the recoveries were 95-99%, respectively. Results of this study show a great potential for the proposed method as a tool for the fast screening of benzoic acid and sorbic acid in a complex matrix.  相似文献   

7.
A novel ionic liquid (IL) bonded fused-sil-ica fiber for headspace solid-phase microextraction (HS-SPME)/gas chromatography-flame ionization detection (GC-FID) of methyl tert-butyl ether (MTBE) in a gasoline sample was prepared and used. The new proposed chemically bonded fiber has better thermal stability and durability than its corresponding physically coated fiber. Another advantage is that no spacer was used for the purpose of bonding the IL to the surface of the fused-silica. The latter advantage makes the preparation of these fibers easier with lower cost than those prepared using sol–gel method. The ionic liquid 1-methyl-3-(3-trimethoxysilyl propyl) imidazolium bis(trifluoromethylsulfonyl) imide was synthesized and cross linked to the surface of the fused-silica fiber. Then, the chemically IL-modified fibers were applied to the headspace extraction of MTBE. The chemically IL-modified fibers showed improved thermal stability at temperatures up to 220 °C relative to the physically IL-modified fibers (180 °C). The chemically bonded IL film on the surface of the fused-silica fiber was durable over 16 headspace extractions without any significant loss of the IL film. The calibration graph was linear in a concentration range of 2–240 μg L−1 (R2 = 0.996) with the detection limit of 0.1 μg L−1 level. The reproducibility (RSD %, n = 6) of the new IL bonded fused-silica fiber (8.9%) was better than the physically coated fiber (12%) suggesting that the proposed chemically IL-modified fiber is more robust than the physically IL-modified fiber. The optimum extraction conditions were the followings: 40 °C extraction temperature, 12 min extraction time, 30 s desorption time and sample agitation at 200 rpm.  相似文献   

8.
Platform and wall vaporization for electrothermal vaporization (ETV)-inductively coupled plasma mass spectrometry (ICP-MS) determination of some refractory elements (Ti, V, Cr, Mo, La and Zr) and Pb were comparatively studied with the use of poly (tetrafluoroethylene) (PTFE) as fluorinating reagent. The factors affecting the vaporization behaviors of the target analytes in the platform and tube wall vaporization including vaporization temperature and time, pyrolytic temperature and time were studied in detail, and the flow rates of carrier gas/auxiliary carrier gas, were carefully optimized. Under the optimal conditions, the signal profiles, signal intensity, interferences of coexisting ions and analytical reproducibility for wall and platform vaporization ETV-ICP-MS were compared. It was found that both wall and platform vaporization could give very similar detection limits, but the platform vaporization provided higher signal intensity and better precision for some refractory elements and Pb than the wall vaporization. Especially for La, the signal intensity obtained by platform vaporization was 3 times higher than that obtained by wall vaporization. For platform vaporization ETV-ICP-MS, the limits of detection (LODs) of 0.001 μg L−1 (La) ~ 0.09 μg L− 1 (Ti) with the relative standard deviations (RSDs) of 1.5% (Pb) ~ 15.5% (Zr) were obtained. While for wall vaporization ETV-ICP-MS, LODs of 0.005 μg L− 1 (La) ~ 0.4 μg L− 1 (Pb) with RSDs of 3.2% (Mo) ~ 12.8% (Zr) were obtained. Both platform and tube wall vaporization techniques have been used for slurry sampling fluorination assisted ETV-ICP-MS direct determination of Ti, V, Cr, Mo, La, Zr and Pb in certified reference materials of NIES No. 8 vehicle exhaust particulates and GBW07401 soil, and the analytical results obtained are in good agreement with the certified values.  相似文献   

9.
In this work a fast liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) method using a C18 Fused Core™ column, was developed for the simultaneous analysis of bisphenol A diglycidyl ether (BADGE), bisphenol A (2,3-dihydroxypropyl) glycidyl ether (BADGE·H2O), bisphenol A bis(2,3-dihydroxypropyl) ether (BADGE·2H2O), bisphenol A (3-chloro-2-hydroxypropyl) glycidyl ether (BADGE·HCl), bisphenol A bis(3-chloro-2-hydroxypropyl) ether (BADGE·2HCl) and bisphenol A (3-chloro-2-hydroxypropyl)(2,3-dihydroxypropyl ether) (BADGE·HCl·H2O) and bisphenol F diglycidyl ether (BFDGE), bisphenol F bis(2,3-dihydroxypropyl) ether (BFDGE·2H2O), bisphenol F bis(3-chloro-2-hydroxypropyl) ether (BFDGE·2HCl). The LC method was coupled with a triple quadrupole mass spectrometer, using an ESI source in positive mode and using the [M+NH4]+ adduct as precursor ion for tandem mass spectrometry experiments. The method developed was applied to the determination of these compounds in canned soft drinks and canned food. OASIS HLB solid phase extraction (SPE) cartridges were used for the analysis of soft drinks, while solid canned food was extracted with ethyl acetate. Method limits of quantitation ranged from 0.13 μg L−1 to 1.6 μg L−1 in soft drinks and 1.0 μg kg−1 to 4.0 μg kg−1 in food samples. BADGE·2H2O was detected in all the analyzed samples, while other BADGEs such as BADGE·H2O, BADGE·HCl·H2O, BADGE·HCl and BADGE·2HCl were also detected in canned foods.  相似文献   

10.
A new separation and quantification method using ultra high-performance liquid chromatography (UHPLC) with UV detection was developed for the detection of sibiromycin in fermentation broth of Streptosporangium sibiricum. The solid phase extraction method based on cation-exchange was employed to pre-concentrate and purify fermentation broth containing sibiromycin prior to UHPLC analysis. The whole assay was validated and showed a linear range of detector response for the quantification of sibiromycin in a concentration from 3.9 to 250.0 μg mL−1, with correlation coefficient of 0.999 and recoveries ranging from 71.66 ± 3.55% to 74.76 ± 5.18%. Method limit of quantification of the assay was determined as 0.18 μg mL−1 and was verified with resulting RSD of 9.6% and accuracy of 97.6%. The developed assay was used to determine the sibiromycin production in 12 different fermentation broths. Moreover, several natural sibiromycin analogues/derivatives were described with pilot characterization using off-line mass spectrometry: the previously described dihydro-sibiromycin (DH-sibiromycin) and tentative bis-glycosyl forms of sibiromycin and its dihydro-analogue.  相似文献   

11.
Fragrances are widespread aquatic contaminants due to their presence in many personal care products used daily in developed countries. Levels of galaxolide and tonalide are commonly found in surface waters, urban wastewaters and river sediments. On the other hand, earthy-musty compounds confer bad odour to drinking water at levels that challenge the analytical capabilities. The combined determination of earthy-musty compounds and fragrances in water would be a breakthrough to make the traditional organoleptic evaluation of the water quality stricter and safer for the analyst. Two approaches were attempted to improve the analytical capabilities: analyte pre-concentration with a newly developed PDMS-DVB solid-phase microextraction fibre on metal alloy core and sensitive detection by tandem mass spectrometry (MS/MS). The optimization of SPME parameters was carried out using a central composite design and desirability functions. The final optimum extraction conditions were: headspace extraction at 70 °C during 40 min adding 200 g L−1 of NaCl. The detection limits in tandem MS (0.02-20 ng L−1) were marginally lower compared to full scan except for geosmin and trichloroanisol which go down to 0.1 and 0.02 ng L−1, respectively.The analysis of different water matrices revealed that fragrances and earthy-musty compounds were absent from ground- and drinking waters. Surface waters of river Leça contained levels of galaxolide around 250 ng L−1 in the 4 terminal sampling stations, which are downstream of WWTPs and polluted tributaries. Geosmine was ubiquitously distributed in natural waters similarly in rivers Leça and Douro at concentrations <7 ng L−1.  相似文献   

12.
A carbon paste electrode was used for the electrochemical determination of linuron concentrations in water and vegetable extracts. Optimal conditions were established with respect to electrode activation (electrochemical pretreatment), time accumulation, potential accumulation, scan rate, and pH. The limit of detection achieved with a pre-concentration step was 23.0 μg L−1. Recovery measurements in vegetable extract and natural water samples were in the range of 98-103%, indicating that the proposed electrochemical method can be employed to analyze linuron in these matrices. The determination results were in good agreement with HPLC results.  相似文献   

13.
Cao Y  Wu X  Wang M 《Talanta》2011,84(4):1530-1194
Nucleic acids can greatly enhance fluorescence intensity of the kaempferol (Km)-Al(III) system in the presence of silver nanoparticles (AgNPs). Based on this, a novel method for the determination of nucleic acids is proposed. Under studied conditions, there are linear relationships between the extent of fluorescence enhancement and the concentration of nucleic acids in the range of 5.0 × 10−9 to 2.0 × 10−6 g mL−1 for fish sperm DNA (fsDNA), 7.0 × 10−9 to 2.0 × 10−6 g mL−1 for salmon sperm DNA (smDNA) and 2.0 × 10−8 to 3.0 × 10−6 g mL−1 for yeast RNA (yRNA), and their detection limits are 2.5 × 10−9 g mL−1, 3.2 × 10−9 g mL−1 and 7.3 × 10−9 g mL−1, respectively. Samples were satisfactorily determined. And the system of Km-Al(III)-AgNPs was used as a fluorescence staining reagent for sensitive DNA detection by DNA pattern of agarose gel electrophoresis analysis. The results indicate that the fluorescence enhancement should be attributed to the formation of Km-Al(III)-AgNPs-nucleic acids aggregations through electrostatic attraction and adsorption bridging action of Al(III) and the surface-enhanced fluorescence effect of AgNPs.  相似文献   

14.
We describe a selective pressurized liquid extraction (SPLE) method, followed by gas chromatography–mass spectrometry (GC–MS), for the simultaneous extraction and clean-up of polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) in sheep liver tissue samples. The on-line clean-up of liver tissue by SPLE was tested using differing amount of acid-modified silica (sulphuric acid:silica gel, 1:2, w/w), the most effective amount being 20 g. Different extraction solvents (iso-hexane and dichloromethane), either alone or in various combinations, were used to extract these target compounds from spiked liver samples. Variables affecting the SPLE extraction efficiency, including temperature, pressure, number of extraction cycles and static extraction time were studied; the optimum parameters were 80 °C, 10.3 MPa, 2 cycles and 5 min, respectively. The SPLE based method was compared with more traditional Soxhlet, off-line PLE, ultrasonic and heating extraction methods. Overall the mean percentage recoveries for all target chemicals using SPLE were 86–103% (n = 3, SD < 9%), and compared favourably with the Soxhlet (63–109%, n = 3, SD < 8%), off-line PLE (82–104%, n = 3, SD < 18%), ultrasonic (86–99%, n = 3, SD < 11%) and heating (72–102%, n = 3, SD < 21%) extraction methods. The limits of detection of the proposed method were 5–96 pg g−1 and 2–29 pg g−1 for the different PBDE and PCB chemicals studied, respectively. The outputs of the proposed method were linear over the range from 0.02 to 30 ng g−1, for all PCB and PBDE congeners except for PBDE 100 and 153 (0.05–30 ng g−1) and PBDE 183 (0.1–30 ng g−1). The method was successfully applied to sheep liver samples for the determination of the target PBDE and PCB compounds.  相似文献   

15.
A method for the quantitative determination of non-steroidal anti-inflammatory drugs (NSAIDs) in sewage sludge was developed and validated. The target compounds were extracted using pressurized hot water extraction (PHWE) and then purified and preconcentrated by three-phase hollow fiber liquid phase microextraction (HF-LPME) followed by LC–ESI-MS analysis. The PHWE was optimized with regard to the pH of solvent as well as other operational parameters. The optimum conditions were 0.01 M NaOH as the extraction solvent, temperature of 120 °C, pressure of 100 bar, static time 5 min, 5 cycles, flush volume 90% and purge time 60 s. Spike recoveries for sludge samples spiked at 200 ng g−1 were in the range of 101–109% but for the native drugs in non-spiked sludge samples, recoveries were 38.9%, 59.8%, 90.3% and 47.8% for ketoprofen, naproxen, diclofenac and ibuprofen, respectively. Donor phase pH, ionic strength and extraction time were optimized for HF-LPME after PHWE. The optimum conditions were 2 h extraction at pH 1.5 without salt addition. Enrichment factors in the range of 947–1213 times were achieved (extraction recoveries were 23.6–30.3%) for HF-LPME after PHWE. The matrix effect on the ionization of drugs in LC–ESI-MS was also investigated. The results show that there is a smaller matrix effect (−8.9% to +14.6%) in comparison with other published values obtained using solid phase extraction (SPE) for clean-up after pressurized liquid extraction (PLE). Method detection limits (MDLs) and method quantification limits (MQLs) for different drugs were in the range of 0.4–3.7 ng g−1 and 1.5–12.2 ng g−1 in dried sludge samples, respectively. The characteristics of the proposed method were compared with those of other published works. The considerably lower ion suppression/enhancement and minimum use of organic solvents (a few microliters of di-n-hexyl ether) in the sample preparation step are two highlighted advantages of the proposed method in comparison with previously published works. The method was applied to determine NSAIDs in sewage sludge from Källby wastewater treatment plant (Lund, Sweden) in April, June, August and October 2010. The highest concentration level was recorded for ibuprofen in the April sewage sludge sample (588 ng g−1) and all of the selected NSAIDs were detected in all the samples analyzed.  相似文献   

16.
A multiresidue analytical method for the determination of emerging pollutants belonging to personal care products (PCPs) (antimicrobials, preservatives), benzotriazole UV stabilizers (BUVSs) and organophosphorus compounds (OPCs) in fish has been developed using high speed solvent extraction (HSSE) followed by silica gel clean up and ultra fast liquid chromatography coupled with tandem mass spectrometry (UFLC–MS/MS) analysis. Developed extraction and clean up method yielded good recovery (>70%) for all the four groups of emerging pollutants, i.e. antimicrobials (78.5–85.6%), preservatives (85.0–89.4%), BUVSs (70.9–112%) and OPCs (81.6–114%; except for TEP – 68.9% and TPeP – 58.1%) with RSDs ranging from 0.7 to 15.4%. Intra- and inter-day repeatabilities were less than 19.8% and 19.0%, respectively at three spiked levels. The concentrations were given in lipid weight (lw) basis, and the method detection limits were achieved in the lowest range of 0.001–0.006 ng g−1 for two antimicrobials, 0.001–0.015 ng g−1 for four preservatives, 0.0002–0.009 ng g−1 for eight BUVSs and 0.001–0.014 ng g−1 for nine OPCs. Finally, the method was successfully validated as a simple and fast extraction method for the determination of 23 compounds belonging to PCPs, BUVSs and OPCs and applied to the analysis of three species of fish from Manila Bay, the Philippines. Concentrations ranged from 27 to 278 ng g−1 for antimicrobials, 6.61 to 1580 ng g−1 for paraben preservatives, −1 for BUVSs and ND (not detected) to 266 ng g−1 for OPCs suggesting the ubiquitous contamination by these emerging pollutants in Manila Bay. This is the first method developed for the determination of triclocarban, four paraben preservatives and four BUVSs, in fish.  相似文献   

17.
A multiclass method for the analysis of residues, in egg matrices, of 41 antimicrobial agents belonging to seven families (sulfonamides, diaminopyridine derivates, quinolones, tetracyclines, macrolides, penicillins and lincosamides) was developed and validated according to the requirements of European Commission Decision 2002/657. Compounds were extracted with a pressurized liquid extraction (PLE) technique using a 1:1 mixture of acetonitrile and a succinic acid buffer (pH 6.0) at 70 °C. As this resulted in clear extracts, no further clean-up was necessary. Analytes were determined by ultra-high-pressure liquid chromatography–tandem mass spectrometry (UHPL–MS/MS) in a chromatographic run of 13 min. Calibration was carried out with spiked blank samples subjected to the entire analytical procedure. Five compounds, two of them isotopically labelled, were used as internal standards. Most analytes were quantified with errors below 10%. Precision in terms of reproducibility standard deviation was between 10% and 20% in most cases. CCα values were in the range 0.5–3.8 μg kg−1 for the non-authorized compounds. The proposed method would enable an experienced analyst to process about 25 samples per day.  相似文献   

18.
Enzymatic hydrolysis of seafood materials for isolating arsenic species (As(III), As(V), DMA and AsB) has been successfully performed by assisting the procedure with ultrasound energy (35 kHz) supplied by an ultrasound water-bath. The use of pepsin, as a proteolytic enzyme, under optimized operating conditions (pH 3.0, temperature 40 °C, enzyme to sample ratio of 0.3) led to an efficient assistance of the enzymatic process in a short period of time (from 4.0 to 30 min). The enzymatic extract was then subjected to a clean-up procedure based on ENVI-Carb™ solid phase extraction (SPE). An optimized anion exchange high performance liquid chromatography (HPLC) coupled to inductively coupled plasma-mass spectrometry (ICP-MS) permitted the fast separation (less than 15 min) of six different arsenic species (arsenite, As(III); arsenate, As(V); dimethylarsinic acid, DMA; and arsenobetaine, AsB; as well as monomethylarsonic acid, MMA; and arsenocholine, AsC) in a single run. Relative standard deviations (n = 11) of the over-all procedure were 7% for AsB and DMA, 11% for As(III) and 9% for MMA. HPLC–ICP-MS determinations were performed using aqueous calibrations covering arsenic concentrations of 0, 5, 10, 25, 100 and 200 μg L−1 (expressed as arsenic) for As(III), As(V), MMA, DMA and AsC; and 0, 125, 250, 500, 750, 1000 and 2000 μg L−1 (expressed as arsenic) for AsB. Germanium (5 μg L−1) was used as an internal standard. Analytical recoveries from the anion exchange column varied from 96 to 105% (enzymatic digests spiked with low target concentrations), from 97 to 104% (enzymatic digests spiked with intermediate target concentrations), and from 98 to 103% (enzymatic digests spiked with high target concentrations). The developed method was successfully applied to two certified reference materials (CRMs), DORM-2 and BCR 627, which offer certified AsB and DMA contents, and also to different seafood samples (mollusks, white fish and cold water fish). Good agreement between certified and found AsB concentrations was achieved when analyzing both CRMs; and also, between certified and found DMA concentrations in BCR 627. In addition, the sum of the different arsenic species concentrations found in most of the analyzed samples was statistically similar to the assessed total arsenic concentrations after a total sample matrix decomposition treatment.  相似文献   

19.
Araújo CL  Melo EI  Coelho NM 《Talanta》2011,84(4):661-1173
The development, evaluation and application of a simple and low-cost graphite carbon electrode for the direct determination of citrate in food samples are described here. The electrode exhibits a linear response with a slope of −29.0 ± 1.0 mV decade−1 in a concentration range of 0.07-7.0 mmol L−1 in 0.1 mol L−1 KCl/1.0 mmol L−1 phosphate buffer solution with a limit of detection of 3.0 μmol L−1. The electrode is easily constructed at a relatively low cost and has a fast time response (within 120 s) with no significant changes in its performance characteristics. The performance of the graphite sensor was tested to determine citrate in beverage samples (juices and an isotonic drink), and the results were validated against a reference procedure. The proposed method is quick, inexpensive, selective and sensitive, and is based entirely on conventional instrumentation.  相似文献   

20.
Field-flow fractionation (FFF) is one of the most versatile separation techniques in the field of analytical separation sciences, capable of separating macromolecules in the range 103–1015 g mol−1 and/or particles with 1 nm–100 μm in diameter. The most universal and most frequently used FFF technique, flow FFF, includes three types of techniques, namely symmetrical flow FFF, hollow fiber flow FFF, and asymmetrical flow FFF which is most established variant among them. This review provides a brief look at the theoretical background of analyte retention and separation efficiency in FFF, followed by a comprehensive overview of the current status of asymmetrical flow FFF with selected applications in the field of biopolymers and bioparticles.  相似文献   