首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-performance capillary electrophoresis (HPCE) method based on laser-induced fluorescence detection is presented here. It enables the determination of sulfur-containing amino acids within 15 min. Fluorescence of sulfur-containing amino acids in plasma is linear over a range of 50-150 micromol/L for L-methionine, 5-100 micromol/L for L-homocysteine, and 50-200 micromol/L for L-cysteine. For homocysteine, we were able to detect 1 fmol injected, equivalent to a plasma concentration of 10 nmol/L. A similar sensitivity is present for cysteine, an even lower one being found for methionine. The intra- and interassay relative standard deviations are < 1%. High-performance liquid chromatography (HPLC) methods are commonly employed for quantifying blood concentrations of sulfur-containing amino acids. A comparative analysis of HPCE and HPLC quantitation of homocysteine has been carried out in 61 blood samples. Plasma concentrations measured by HPCE were in good agreement with those obtained employing an HPLC-based method, a satisfactory correlation being observed between the concentrations obtained by the two methods (r= 0.9972). Thus, the HPCE-based procedure presented here for the measurement of sulfur-containing amino acids in plasma is a simple, fast, accurate, and very sensitive method, suitable for routine determinations in clinical studies.  相似文献   

2.
Quantitative analysis of amino acids in blood and urine is primarily indicated for the diagnosis of amino acid disorders. The high-performance liquid chromatography (HPLC) technique is frequently used for this detection. The frequency of sample collection on filter paper has been increasing exponentially, and there are many advantages attributed to processing biological samples in this way. The aim of this study was to validate a quantitative analysis of amino acids by HPLC in blood and urine collected on filter paper and to establish reference values in the neonatal period. Dried blood and dried urine samples of respectively 58 and 45 healthy newborns (2–9 days) were collected. Pre-treatment and extraction of samples were done according to the literature. Separation and analysis of amino acids were carried out by HPLC with fluorescence detection. The developed method demonstrated excellent separation, linearity, limits of detection and quantification, repeatability and recovery. The reference values for 17 amino acids were defined in dried blood and urine samples of newborns. This work presents a simple, fast and effective method for the simultaneous analysis of 17 amino acids in blood and urine collected on filter paper in a single run. The reference values were established and validated.  相似文献   

3.
白洁  王妲  刘泽平  张佳琪  刘丽艳  韩艳梅 《色谱》2020,38(8):923-928
以邻苯二甲醛(o-phthalaldehyde,OPA)为衍生试剂,建立了柱前衍生-高效液相色谱(HPLC)同时测定血清中氨基酸类神经递质牛磺酸(Tau)、谷氨酸(Glu)、甘氨酸(Gly)、γ-氨基丁酸(γ-GABA)和单胺类神经递质多巴胺(DA)含量的分析方法。血清与乙醇以1:2的体积比混合,进行蛋白质沉淀后离心,取其上清液,氮吹至近干。前处理后的样品与OPA进行柱前衍生,衍生化产物采用Luna 5u C18色谱柱(250 mm×4.6 mm,5 μm)分离,以柠檬酸-乙酸钠缓冲溶液(pH 3.73)为流动相A、乙腈为流动相B进行梯度洗脱,流速为1.0 mL/min,柱温为30℃,检测波长为338 nm。5种神经递质在各自范围内线性关系良好(r2≥0.9866),检出限为0.10~0.40 μmol/L,不同加标水平下目标物的加标回收率为87.57%~115.31%,相对标准偏差均低于7.80%。方法操作简单,灵敏度高,精密度、线性关系和回收率等方法学指标较好,可实现血清中氨基酸类及单胺类神经递质的同时检测。  相似文献   

4.
A simple, sensitive and reproducible isocratic high-performance liquid chromatography (HPLC) method has been developed for the determination of amino acids in human serum. The method involves precipitation of the serum proteins with methanol followed by pre-column derivatization of amino acids with o-phthalaldehyde-2-mercaptoethanol or o-phthalaldehyde-sodium sulfite. HPLC separation of the derivatives was performed using an ODS column with an isocratic mobile phase system and electrochemical detection (+0.75 V). The response was linear over the range 5-300 microM for all amino acids. The method allows quantitative determination of glutamic acid, asparagine, serine, glutamine, histidine, taurine, alanine, arginine, methionine, isoleucine, ornithine, leucine, phenylalanine, lysine and tryptophan at concentrations as low as 0.5-5.0 pmol (signal-to-noise ratio=2). Using this method, the levels of amino acids in serum from healthy donors and patients with ischemic stroke were determined.  相似文献   

5.
A rapid and sensitive method was developed for the analysis of amino acids by microchip electrophoresis with Hg-lamp excitation fluorescence detection. Fluorescein-isothiocyanate (FITC) was chosen to estimate the sensitivity of this system, and the detection limit (S/N = 3) with FITC was 1.7 nM, which showed that the system was sensitive as well as simple. Two derivatizing agents, FITC and ortho-phthalaldehyde (OPA) were employed to label amino acids and were compared in the same fluorescence detection system with an Hg lamp as the excitation source. The separation parameters were optimized in detail. Optimum separation of OPA-labeled amino acids was obtained in less than 200 s with 20 mM borate buffer (pH 9.0) containing 20% acetonitrile and 10 mM beta-cyclodextrin. Detection limits for amino acids (alanine (Ala), taurine (Tau), glycine (Gly), glutamic acid (Glu), and aspartic acid (Asp)) of 0.38-1.0 muM were achieved. The method was successfully applied to analysis of amino acids in human vascular endothelial cells (ECV-304). The average amount of amino acids in single ECV-304 cells is estimated to be 5.84 fmol for Ala, 2.78 fmol for Tau, 1.15 fmol for Gly, 3.10 fmol for Glu, and 1.30 fmol for Asp.  相似文献   

6.
Taurine is an amino acid which is not incorporated into proteins but found in the cytosol of many mammalian cells, in high concentrations (2–30 mM). Increase in plasma taurine concentration has already been reported after surgical trauma, X-radiation, muscle necrosis, carbon tetrachloride-induced liver damage, and paracetamol overdose. Plasma taurine concentration was measured using LC with fluorescence detection following derivatization by o-phtalaldehyde plus 3-mercapto-propionic acid and α-aminobutyric acid as internal standard. Under these conditions the retention time of taurine was 10 min. This method was sensitive enough, to quantify 150 pg mL?1 and detect 50 pg mL?1 of taurine ranging normally between 65 and 179 mmol L?1 (8–22 μg mL?1). The validated method allowed simple determination of human plasma taurine in pharmacokinetic and biomarker studies.  相似文献   

7.
A high-performance liquid chromatographic method (HPLC) with combined diode array and fluorescence detection of amino acids and amines in various cheese samples is described. The proposal is based on acidic deproteinization, derivatization and gradient optimization studies, resulting in the identification and quantification of 21 amino acids and 9 amines from a single solution, by one injection. The optimized, simple protocol consists of deproteinization (1M perchloric acid), centrifugation, filtration and the subsequent derivatization with the o-phthalaldehyde-ethanethiol-9-fluorenylmethyl chloroformate (OPA-ET-FMOC) reagent. The method can be characterized with a linearity of wide concentration range (6.25-1000pM/injection), a good chromatographic reproducibility (average: 2.69% RSD) and an excellent recovery (average: 100.2%; average 3.84% RSD). The developed method was successfully applied in the determination of the amino acid and amine contents of port salut cheese, blue cheese and smoked cheese samples.  相似文献   

8.

Taurine is an amino acid which is not incorporated into proteins but found in the cytosol of many mammalian cells, in high concentrations (2–30 mM). Increase in plasma taurine concentration has already been reported after surgical trauma, X-radiation, muscle necrosis, carbon tetrachloride-induced liver damage, and paracetamol overdose. Plasma taurine concentration was measured using LC with fluorescence detection following derivatization by o-phtalaldehyde plus 3-mercapto-propionic acid and α-aminobutyric acid as internal standard. Under these conditions the retention time of taurine was 10 min. This method was sensitive enough, to quantify 150 pg mL−1 and detect 50 pg mL−1 of taurine ranging normally between 65 and 179 mmol L−1 (8–22 μg mL−1). The validated method allowed simple determination of human plasma taurine in pharmacokinetic and biomarker studies.

  相似文献   

9.
马明生  韩慧婉  刘国诠 《色谱》1995,13(4):257-261
Laser induced fluorescence(LIF)detector as a highiy sensitive detector for HPLC and HPCE was widelyused in biochenllcal analysis,DNA sequencing,immunoassay,etc.In the present paper a review of LIF forHPLC and HPCE was reported with 48 references. The principles for choice of the components contained in aLIF detector,such as,a lase,optic lens,filters and a photodetector,were reviewed in detail.Various opticdesigns and detection flow cells were also reviewed.  相似文献   

10.
A simple and sensitive high-performance liquid chromatography (HPLC) method is proposed for the analysis of some carboxylic acids in food samples and the environment. The use of 9-chloromethyl anthracene as a fluorescence-labeling reagent has been investigated. The derivatization reagent reacts with unitary carboxylic acids and tetrabutylammonium bromide as a catalyst within 50 min in acetonitrile to give esters, which can be separated by HPLC employing fluorescence detection at λ(ex) = 365 and λ(em) = 410 nm. The optimum conditions for derivatization, fluorescence detection and chromatographic separation are established. The method shows good sensitivity, with a detection limit from 0.18 to 2.53 pmol, and good linearity between 1-250 nmol/mL of each analyte. The practical applicability of the method was demonstrated by analyzing samples that were spiked with the acid standards, environment and food samples.  相似文献   

11.
Volpi N 《Electrophoresis》2003,24(6):1063-1068
A rapid, highly sensitive and reproducible high-performance capillary electrophoresis (HPCE) method (electrokinetic chromatography with sodium dodecyl sulfate) is described for the determination of disaccharides present in the polysaccharide from the uropathogenic Escherichia coli K4 bacteria (05:K4:H4) and its defructosylated product. Following chondroitinase digestion of K4 and its derivative, the two disaccharides, DeltaHexAFrc-GalNAc for K4 and deltaHexA-GalNAc for defructosylated K4, are separated and readily determined within 20 min on an uncoated fused-silica capillary using normal polarity at 20 kV and detection at 230 nm. Comparison was made by separation of these two disaccharides in isocratic strong-anion exchange HPLC. A linear relationship was found for the two unsaturated disaccharides over a wide range of concentrations, from approximately 0.5 to 5 micro g for high-performance liquid chromatography (HPLC) and from approximately 0.06 to 0.3 micro g for HPCE. The HPCE separation produced a greater detection sensitivity (about 10 times greater) than HPLC. The described methods were used to evaluate the defructosylation process of K4 under drastic acid conditions. Good correspondence was found for the amount of unsaturated disaccharides for the two techniques.  相似文献   

12.
Pheomelanin is an important type of melanin distributed in the skin, eye and hair in the mammal, which is of great social, clinical and cosmetic significance. In this study, a new HPLC method with fluorescence detection is described originally for the sensitive determination of pheomelanin in biological materials. The pheomelanin polymer is decomposed into two specific degradation products, 3-amino-4-hydroxyphenylalanine (3-AHP) and 4-amino-3- hydroxyphenylalanine (4-AHP) with hydriodic acid. Then the two AHP isomers are derivatized using a fluorescent probe naphthalene-2,3-dicarboxaldehyde in the presence of cyanide. The resulting highly stable 2-substituted 1-cyanobenz[f] isoindole derivatives were separated on a 5NH(2)-MS aminopropyl packed HPLC column with binary isocratic elution profile and detected fluorimetrically. The assay shows high sensitivity of 0.11nM (2.2fmol per injection, the lowest reported) at signal-to-noise ratio of 3 for each AHPs, good accuracy and precision (RSDs<3.1%), and linearity (range of 0.02-10microM, r>0.995). The results obtained by using fluorescence detection have been compared with other detection systems (electrochemical and UV). The sensitivity can increase from 100 to respect electrochemical detection and 30000 times respect UV detection. The method has been used for the quantitative determination of pheomelanin in various biological samples, including cell cultures from five types of melanoma cell lines of human and rat origin, hair samples of various colors, melanoma tissue and the urines from human melanoma patients and healthy subjects. This original application of HPLC-fluorescence detection represents a powerful tool for investigating pheomelanin synthesis in vitro and in vivo under physiological and pathophysiological conditions.  相似文献   

13.
A high performance liquid chromatographic (HPLC) method for analysis of 4 free and 8 conjugated bile acids in submicromolar quantities in serum is described using precolumn derivatization with 4-bromomethyl-7-methoxycoumarin (BMC) and fluorescence detection. Bile acids were extracted from serum with 0.4 M sodium bicarbonate, adsorbed onto a Sep-Pak C18 cartridge and eluted with methanol. The extract was derivatized with BMC in acetonitrile using 18-crown-6 crown ether as catalyst and the BMC labelled glycine conjugates and free bile acids were analysed using acetonitrile + methanol + water gradient elution and detection at 320/385 nm. Using a novel and simple approach, taurine conjugates were isolated by extracting the dried, derivatized material with water, in contrast to previous methods which required column chromatography cleanup to isolate the taurine conjugates prior to derivatization. The isolated taurine conjugates were then hydrolysed enzymatically, extracted, derivatized and analysed as free-bile acids. Recoveries of individual bile acids varied from 83-96% for free and glycine conjugates and 72-83% for taurine conjugates. Coefficients of variation were in the range of 5.1-12.5%. In addition to the simpler and shorter procedure for taurine conjugates, this method has increased sensitivity over most other procedures and improved HPLC separation for the various bile acids and conjugates with equivalent recovery and reproducibility compared with other published methods.  相似文献   

14.
将荧光试剂2,3-二甲醛基喹喔啉首次应用到氨基酸的高效液相色谱分离分析中。考察了该荧光试剂与伯胺氨基酸衍生反应的pH值、比例、反应时间等影响因素,确定衍生反应的最佳条件为:100 mmol/L硼砂缓冲液(pH 9.5),二巯基乙醇、衍生试剂与氨基酸的比例为9∶3∶1,室温下反应5 min。采用C18色谱柱,经二元梯度洗脱,荧光检测,17种伯胺蛋白氨基酸得到较好分离。氨基酸的浓度在0.01~1.00 mmol/L范围内与其衍生物峰面积呈较好的线性关系,氨基酸衍生物的检出限为0.02~0.07μg/L。应用该方法对麦冬中游离氨基酸的含量进行测定,结果满意。此方法快速,高效,灵敏度高,精密度好。  相似文献   

15.
The determination of amino acids with actions like neurotransmitters or modulators has been increasingly important for diagnosis in many neuropsychiatric diseases. A rapid and simple high‐performance liquid chromatography with fluorescence detection method was developed for simultaneous determination of seven amino acids: aspartate (Asp), glutamate (Glu), serine (Ser), glutamine (Gln), glycine (Gly), taurine (Tau) and γ‐aminobutyric` acid (GABA). Homoserine was used as an internal standard. The analysis was performed on a BDS column with methanol and 50 mm sodium acetate solution (pH 6.5) using a simple gradient elution. Several parameters of the developed method were validated including linearity, accuracy, precision, extraction recovery and stability, which were within the acceptable range. The method was successfully applied to determination of real samples: hippocampus and cortex in depressed rats exposed to chronically unpredictable stress in order to study if there existed differences in the seven amino acids levels between depressed rats and control. The results showed that Asp, Gly, Tau and GABA significantly decreased with increasing Gln in the hippocampus of depressed rats, compared with that of the control group, among which obviously lower level of Asp and higher level of Gln in cortex were observed. The analytical method and the results could be useful for clinical diagnosis and further insight into pathophysiological mechanism of depression.  相似文献   

16.
《Analytical letters》2012,45(7):1439-1449
Abstract

In this work, the (R)‐N,N,N‐trimethyl‐2‐aminobutanol‐bis(trifluoromethanesulfon)imidate chiral ionic liquid was first used in chromatography and exhibited a excellent chiral recognition ability in high performance capillary electrophoresis (HPCE), high performance liquid chromatography (HPLC), and capillary gas chromatography (CGC), which also showed for the first time that chrial ionic liquid was an effective chiral selector in HPCE and HPLC. The compounds that have been separated using this chiral ionic liquid at least included alcohol, amine, acid, and amino acid, et al. enantiomers. As the chiral ionic liquid can be easily synthesized from relatively inexpensive materials, it should have a great potentiality for chiral separation in chromatographic science.  相似文献   

17.
Naphthalene-2,3-dicarboxyaldehyde (NDA) is commonly used for detection of primary amines in conjunction with their separation with HPLC and CE. The fluorescence of the derivatives can be measured by a conventional fluorometer or via LIF. NDA is a reactive dye, which can replace o-phthaldehyde (OPA) and provides for derivatives which are considerably more stable than OPA derivatives. In addition, NDA can be used to derivatize primary amines at concentrations as low as 100 pM. In this work, HPLC/fluorescence and MEKC/LIF experiments were performed to separate/detect six neuroactive compounds, the amino acids, Gly, Glu, Asp, gamma-aminobutyric acid (GABA) and the catecholamines, dopamine and noradrenaline. The two methods were compared in terms of performance of separation. The amino acids can be separated in HPLC in less than 30 min and an identical separation is obtained in CE using MEKC and lithium salts with greater resolution (the number of theoretical plates was approximately 5000 for HPLC and 200 000 for MEKC). The lowest detected concentration was in the range of 0.1 nM for CE/LIF. The presence of a high salt concentration does not affect the separation of the samples. Examples of the analysis of microdialysate samples as well as amino acids in Ringer's solution are presented.  相似文献   

18.
The quantitation of thiopental in human serum and plasma was investigated using high-performance capillary electrophoresis (HPCE) in a micellar configuration and the results were compared with reversed-phase high-performance liquid chromatography (HPLC). Thiopental and an internal standard (carbamazepine for HPCE and thiamylal for HPLC) were extracted from serum or plasma using pentane and a phosphate buffer (pH 6.4). HPCE analysis took place in a phosphate-borate buffer with 50 mM sodium dodecyl sulphate using an automated instrument and HPLC was performed with a C8 column and a mobile phase of phosphate buffer-acetonitrile (65:35, v/v). HPCE and HPLC data from 66 patient samples compared well based on linear regression analysis. However, estimates obtained with the inclusion of the internal standard were lower than those based on the sample peak only. This example allows the elucidation of the advantages of using HPCE as an assay methodology for the therapeutic monitoring of thiopental and other drugs.  相似文献   

19.
A sensitive and selective high-performance capillary electrophoresis (HPCE) procedure was developed for the determination of total cicletanine in human plasma. The procedure consisted in extraction of the drug with diethyl ether and analysis by micellar electrokinetic capillary chromatography in a fused-silica capillary using sodium dodecyl sulphate in the run buffers and ultraviolet detection. The concentrations of cicletanine obtained by this method were compared with those obtained by a high-performance liquid chromatographic (HPLC) method used routinely. The within-run precision of the methods, expressed as relative standard deviation, ranged from 1.6 to 7.8% for HPLC and from 6.4 to 11.1% for HPCE. Both methods showed an adequate level of accuracy; the relative errors ranged from 0.02 to 3.25% for HPLC and from 0.21 to 2.90% for HPCE. The HPCE method required less than half the time taken by the HPLC method, making HPCE a useful alternative technique for the routine determination of cicletanine in plasma. Both methods were used to follow the time course of total cicletanine in human plasma after a single oral therapeutic dose of the drug.  相似文献   

20.
痕量氨基糖和中性单糖的高效毛细管电泳及液相色谱分析   总被引:8,自引:0,他引:8  
林启山  张任恩  刘国诠 《色谱》1995,13(1):12-15
由于糖缀合物具有较弱的紫外吸收,采用了一种与单糖有高反应活性的新型紫外、荧光衍生试剂芴甲氧羰基肼(FMOC-Hydrazine)和芴甲氧羰基氯(FMOC-cl)对单糖进行衍生。利用高效毛细管电泳(HPcE)和液相色谱技术对衍生产物进行了分析。结果表明:以上衍生试剂可用于fmol级单糖的测定。对单糖的HPCE分离因素进行了详细讨论。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号