 共查询到20条相似文献,搜索用时 15 毫秒
1.
This work describes the synchronized dual-polarity (DP) electrospray ionization (ESI) method and demonstrates the first DP ESI mass spectra obtained using two mass spectrometers. Stable double Taylor cones were produced by applying two counter electric voltages with opposite polarities to one electrosprayer. The development of double Taylor cones required higher extraction voltages than conventional ESI, but DP ESI worked effectively at liquid flow rate range three times wider than conventional ESI. Using pure methanol, the emission currents of the two cones were neutralized and no current was drawn from the sprayer. Synchronized DP mass spectra were obtained using electrospray calibrants dissolved in methanol solution of low water content. For bovine insulin with conventional electrospray solution, the gas-assisted electrospray delivered satisfactory sensitivity and stability for routine mass analyses.  相似文献   

2.
3.
An emitter electrode with an electroactive poly(pyrrole) (PPy) polymer film coating was constructed for use in electrospray ionization mass spectrometry (ESI‐MS). The PPy film acted as a surface‐attached redox buffer limiting the interfacial potential of the emitter electrode. While extensive oxidation of selected analytes (reserpine and amodiaquine) was observed in positive ion mode ESI using a bare metal (gold) emitter electrode, the oxidation was suppressed for these same analytes when using the PPy‐coated electrode. A semi‐quantitative relationship between the rate of oxidation observed and the interfacial potential of the emitter electrode was shown. The redox buffer capacity, and therefore the lifetime of the redox buffering effect, correlated with the oxidation potential of the analyte and with the magnitude of the film charge capacity. Online reduction of the PPy polymer layer using negative ion mode ESI between analyte injections was shown to successfully restore the redox buffering capacity of the polymer film to its initial state. Published in 2010 by John Wiley & Sons, Ltd.  相似文献   

4.
Rezenom YH  Dong J  Murray KK 《The Analyst》2008,133(2):226-232
We have used an infrared laser for desorption of material and ionization by interaction with electrosprayed solvent. Infrared laser-assisted desorption electrospray ionization (IR LADESI) mass spectrometry was used for the direct analysis of water-containing samples under ambient conditions. An ion trap mass spectrometer was modified to include a pulsed Er:YAG laser at 2.94 microm wavelength coupled into a germanium oxide optical fiber for desorption at atmospheric pressure and a nanoelectrospray source for ionization. Analytes in aqueous solution were placed on a stainless steel target and irradiated with the pulsed IR laser. Material desorbed and ablated from the target was ionized by a continuous stream of charged droplets from the electrosprayed solvent. Peptide and protein samples analyzed using this method yield mass spectra similar to those obtained by conventional electrospray. Blood and urine were analyzed without sample pretreatment to demonstrate the capability of IR LADESI for direct analysis of biological fluids. Pharmaceutical products were also directly analyzed. Finally, the role of water as a matrix in the IR LADESI process is discussed.  相似文献   

5.
6.
Editorial Comment Last month we presented, as a Special Feature, a set of five articles that constituted a Commentary on the fundamentals and mechanism of electrospray ionization (ESI). These articles produced some lively discussion among the authors on the role of electrochemistry in ESI. Six authors participated in a detailed exchange of views on this topic, the final results of which constitute this month's Special Feature. We particularly hope that younger scientists will find value in this month's Special Feature, not only for the science that it teaches but also what it reveals about the processes by which scientific conclusions are drawn. To a degree, the contributions part the curtains on these processes and show science in action. We sincerely thank the contributors to this discussion. The give and take of intellectual debate is not always easy, and to a remarkable extent this set of authors has maintained good humor and friendships, even when disagreeing strongly on substance. Graham Cooks and Richard Caprioli Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

7.
8.
By electrospray ionization (ESI) mass spectrometry, micelle solutions of sodium cholate were investigated in detail in the presence and absence of ethanol. The average aggregation number could be evaluated from the spectra acquired under conditions where soft collisions adequate to measure the micelle solution were induced, and the value agreed well with that obtained previously by other methods. From the dependence on ethanol content, it was also found that the average aggregation number in aqueous solution without organic solvent could be reliably estimated. The ESI method proved to be a useful tool for determining the micelle mass in the original aqueous phase.  相似文献   

9.
A multiple sprayer electrospray ion source for high-throughput analysis is described. The ion source is comprised of multiple electrospray capillaries, each with an ion lens located near the tip. The electric potentials applied to the ion lenses are used to control the sprayers. The use of ion lenses eliminates the need for mechanical blocking devices to selectively enable or disable the sprayers, and results in a less expensive and more reliable set-up. Sprayers can be enabled or disabled within approximately 50-250 ms when the lens potentials are controlled manually. For simultaneous operation of multiple electrospray capillaries, it is advantageous to orient the capillaries so that the spray from each passes directly in front of the entrance aperture of the mass spectrometer.  相似文献   

10.
Analysis of petroleum samples at the molecular level by Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) typically requires a prolonged accumulation of ions and/or summing up a large number of scans. Here, a chip-based micro-ESI system (Advion NanoMate, Ithaca, NY) has been successfully automated in combination with FT-ICR MS analysis of petroleum samples. A foil-sealed 96-well glass plate prevents solvent evaporation, with no visible loss of sample after 20 h of continuous operation. Mass spectra obtained from the same sample but taken from different wells after various time delays were very similar. Data from replicate samples in different wells could be combined to enhance mass spectral signal-to-noise ratio and dynamic range. Furthermore, the automated data acquisition eliminates sample carryover, and produces heteroatom class distribution, double-bond equivalents (DBE), and carbon number very similar to those from the conventional (manual) micro-ESI experiments.  相似文献   

11.
A non-tapered open tubular emitter with 75 microm internal diameter (i.d.) and 360 microm external diameter (o.d.) was developed by simply grinding the exit aperture of a fused-silica capillary. The roughened emitter, with a relatively large aperture, generates stable electrospray signals (generally <5% relative standard deviation (RSD) for most conditions studied) at less than 500 nL/min flow rates, and was characterized with atomic force microscopy. The surface treatment greatly extends the operational range of an open tubular emitter to lower flow rates, compared to that of a cleaved capillary with similar dimensions. The stabilized nanoelectrospray is attributed to the increased surface roughness and modified wetting characteristics of the emitter exit resulting from grinding. Electrospray performance was evaluated, and as a result of the enhanced sensitivity from a roughened emitter, five femtomoles of leucine enkephalin were detected at a 50 nL/min flow rate with a signal to noise (S/N) ratio of 48. Furthermore, trypsin-digested bovine serum albumin (BSA) was used to demonstrate the application of the emitter in protein identification, giving a sequence coverage of 60%. These emitters are robust, and may become a facile alternative to tapered emitters at moderate nano flow rates (e.g. 50 to 500 nL/min).  相似文献   

12.
Positive ion electrospray ionization mass spectra have been obtained of deoxyribonucleic acids (DNA) and ribonucleic acids (RNA), including transfer RNAs (77-mer, ~ 25 kDa). For several different solution conditions, the charge state distributions of DNA and RNA molecules were determined. It is postulated that the production of the multiply charged positive ions results from gas phase dissociation of complexes between nitrogen-containing bases and oligonucleotides.  相似文献   

13.
A battery-powered, controlled-current, two-electrode electrochemical cell containing a porous flow-through working electrode with high surface area and multiple auxiliary electrodes with small total surface area was incorporated into the electrospray emitter circuit to control the electrochemical reactions of analytes in the electrospray emitter. This cell system provided the ability to control the extent of analyte oxidation in positive ion mode in the electrospray emitter by simply setting the magnitude and polarity of the current at the working electrode. In addition, this cell provided the ability to effectively reduce analytes in positive ion mode and oxidize analytes in negative ion mode. The small size, economics, and ease of use of such a battery-powered controlled-current emitter cell was demonstrated by powering a single resistor and switch circuit with a small-size, 3 V watch battery, all of which might be incorporated on the emitter cell.  相似文献   

14.
Electrospray mass spectrometry was used to simultaneously determine aspartame (APM) and five of its degradation products; aspartic acid, aspartylphenylalanine, 5-benzyl-3,6-dioxo-2-piperazieacetic acid (diketopiperazine), phenylalanine, and phenylalanine methyl ester. Under the ionization conditions used, there was no interfering fragmentation for any of the six compounds, i.e., no fragmentation of the compound being tested into other species also being monitored. A study of APM degradation in solution at various pH's and at various temperatures using this method was performed.  相似文献   

15.
An electrospray ionization ion source coupled to a time-of-flight mass analyzer incorporating a multi-anode time-to-digital converter is described. High-speed data acquisition (kHz mass spectral acquisition) rates are achieved. The four-anode detector produces a significant increase in detection/counting efficiency over that for a single-anode detector. In this work a 2.5 times increase in detection efficiency is demonstrated. The multi-anode detector is also used as a diagnostic tool to optimize transmission of the ion optics.  相似文献   

16.
Some tenets pertaining to electrospray ionization mass spectrometry   总被引:6,自引:0,他引:6  
The field of electrospray ionization mass spectrometry is reviewed with emphasis placed upon advances in the elucidation of fundamental mechanistic aspects of the ionization process that have been reported over the past 10 years. The analytical consequences of these findings are also examined. Eight central conclusions or 'tenets' are presented, as deduced from the body of work contained in 80 references.  相似文献   

17.
18.
Desorption electrospray ionization mass spectrometry of intact bacteria   总被引:1,自引:0,他引:1  
Desorption electrospray ionization (DESI) mass spectrometry (MS) was used to differentiate seven bacteria species on the basis of their measured DESI-mass spectral profile. Both gram-positive and gram-negative bacteria were tested and included Escherichia coli, Staphyloccocus aureus, Enterococcus sp., Bordetella bronchiseptica, Bacillus thuringiensis, Bacillus subtilis and Salmonella typhimurium. Distinct DESI-mass spectra, in the mass range of 50-500 u, were obtained from whole bacteria in either positive or negative ion modes in less than 2 mins analysis time. Positive ion DESI-mass spectral fingerprints were compared using principal components analysis (PCA) to investigate reproducibility for the intraday and the day-to-day measurements and the method selectivity to differentiate the bacteria studied. Detailed study of variances in the assay revealed that a large contribution to the DESI-mass spectral fingerprint variation was the growth media preparation procedure. Specifically, experiments conducted with the growth media prepared using the same batch yielded highly reproducible DESI-mass spectra, both in intraday and in day-to-day analyses (i.e. one batch of growth media used over a 3-day period versus a new batch every day over the same 3-day period). Conclusions are drawn from our findings in terms of strategies for rapid biodetection with DESI-MS.  相似文献   

19.
A novel high-frequency alternating current (AC) electrospray ionization (ESI) source has been developed for applications in mass spectrometry. The AC ESI source operates in a conical meniscus mode, analogous to the cone-jet mode of direct current (DC) electrosprays but with significant physical and mechanistic differences. In this stable conical-meniscus mode at frequencies greater than 50 kHz, the low mobility ions, which can either be cations or anions, are entrained within the liquid cone and ejected as droplets that eventually form molecular ions, thus making AC ESI a viable tool for both negative and positive mode mass spectrometry. The performance of the AC ESI source is qualitatively shown to be frequency-dependent and, for larger bio-molecules, the AC ESI source produced an ion signal intensity that is an order of magnitude higher than its DC counterpart.  相似文献   

20.
A novel microfabricated device for isoelectric focusing (IEF) incorporating an optimized electrospray ionization (ESI) tip was constructed on polycarbonate plates using laser micromachining. The IEF microchip incorporated a separation channel (50 micro x 30 micro x 16 cm), three fluid connectors, and two buffer reservoirs. Electrical potentials used for IEF focusing and electrospray were applied through platinum electrodes placed in the buffer reservoirs, which were isolated from the separation channel by porous membranes. Direct ESI-mass spectrometry (MS) using electrosprays produced directly from a sharp emitter "tip" on the microchip was evaluated. The results indicated that this design can produce a stable electrospray and that performance was further improved and made more flexible with the assistance of a sheath gas and sheath liquid. Error analysis of the spectral data showed that the standard deviation in signal intensity for an analyte peak was less than approximately 5% over 3 h. The production of stable electrosprays directly from microchip IEF device represents a step towards easily fabricated microanalytical devices. Microchannel IEF separations of protein mixtures were demonstrated for uncoated polycarbonate microchips. Direct microchannel IEF-ESI-MS was demonstrated using the microfabricated chip with an ion-trap mass spectrometer for characterization of protein mixtures.  相似文献   