首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Inductively coupled plasma-mass spectrometry (ICP-MS) was coupled to a gas chromatographic (GC) system with electron capture detector (ECD), which enables relatively easy characterization and quantification of brominated and iodinated (halogenated) volatile organic compounds (HVOCs) in aquatic and air samples. The GC-ECD system is connected in series with an ICP-MS by a directly heated transfer line and an outlet port-hole for elimination of the ECD make-up gas during ignition of the plasma. The hyphenated GC-ECD/ICP-MS system provides high selectivity and sensitivity for monitoring individual HVOCs under fast chromatographic conditions. The ECD is most sensitive for the detection of chlorinated and brominated but the ICP-MS for iodinated compounds. The greatest advantage of the use of an ICP-MS is its element-specific detection, which allows clear identification of compounds in most cases. The absolute detection limits for ICP-MS are 0.5 pg for iodinated, 10 pg for brominated, and 50 pg for chlorinated HVOCs with the additional advantage that calibration is almost independent on different compounds of the same halogen. In contrast to that detection limits for ECD vary for the different halogenated compounds and lie in the range of 0.03-11 pg. The two-dimensional GC-ECD/ICP-MS instrumentation is compared with electron impact mass spectrometry (EI-MS) and microwave induced plasma atomic emission detection (MIP-AED). Even if EI-MS has additional power in identifying unknown peaks by its scan mode, the detection limits are much higher compared with GC-ECD/ICP-MS, whereas the selective ion monitoring mode (SIM) reaches similar detection limits. The MIP-AED detection limits are at the same level as EI-MS in the scan mode.  相似文献   

2.
Summary Capillary gas chromatography coupled to both mass spectrometry (GCMS) and atomic emission spectroscopy (GC-AED) was studied for the analysis of bromine-containing alkylbenzenes present in sludge from a nickel refinery. Owing to the high abundance of chlorinated compounds, location of the brominated species was difficult based on GC-MS with electron ionization. In contrast, GC-MS with negative chemical ionization (GC-NCIMS) and GC-AED enabled bromine-selective detection and were utilized for an effective location of the brominated compounds. Bromine-selective detection by GC-NCIMS relied on the monitoring of Br (m/z 79/81) with CH4 as ionization gas, while atomic emission (827.2 nm) from a helium plasma was utilized in the case of GC-AED. While GC-NCIMS was 30–500 times more sensitive than GC-AED, the latter technique was superior for quantitative purposes. Because the bromine response of the AED was independent of molecular structure, quantification was possible without reference material.  相似文献   

3.
The analysis by gas chromatography coupled with mass spectrometry (GC/MS) of 40 different congeners of polybrominated diphenyl ethers (PBDEs) containing 1-7 bromine atoms is described. Two different MS approaches were used, negative chemical ionization (NCI-MS) and electron ionization (EI-MS). Operating parameters such as electron energy and source temperature were optimized in order to obtain the maximum sensitivity in the EI-MS study. For NCI-MS analyses, the effects of the moderating gas (methane or ammonia), source temperature and system pressure were studied. The quality parameters of the two approaches tested were compared. NCI-MS gave detection limits between 30 fg and 1.72 pg, whereas EI-MS gave detection limits between 0.53 and 32.09 pg. The main advantage of EI-MS is that it provides better structural information. Moreover, the use of EI-MS allowed the use of an isotope dilution method for quantification, making the analysis more reliable at trace levels.  相似文献   

4.
A time- and cost-saving method for the congener-specific analysis of polychlorinated biphenyls (PCBs) in human serum has been developed and validated. After two fast extraction and clean-up steps, analyses were performed using gas chromatography coupled with mass spectrometry with single ion monitoring (GC/SIM-MS), either in electron impact (EI) or electron-capture negative ionization (ECNI) mode. For the determination of dioxin-like congeners, an improvement in EI-MS sensitivity is desirable and use of NI is thus preferred. The procedure was validated for 12 dioxin-like congeners by analyzing spiked samples on three different days and using (13)C(12)-labelled analogues as internal standards. When using an NCI source, the limit of quantification was assessed at 0.01 microg/L, except for PCBs #77 and #81, which cannot be reliably detected below 0.05 microg/L. For the lower chlorinated non-dioxin-like congeners, NI offers less selectivity because of limited fragmentation. Electron impact ionization and electron-capture negative ionization mode can therefore be considered to be complementary for the determination of PCB congeners in the general population.  相似文献   

5.
The Certificate of Analysis for SRM 1589a PCBs, Pesticides, PBDEs, and Dioxins/Furans in Human Serum has been updated to include certified concentration values for 27 polychlorinated biphenyl (PCB) congeners, three chlorinated pesticides, and four polybrominated diphenyl ether (PBDE) congeners as well as reference concentration values for 27 additional PCB congeners, six additional chlorinated pesticides, three additional PBDE congeners, and selected polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs). This represents an addition of concentration values for 29 PCB congeners and for PBDE congeners that were not quantified in the previous issue of SRM 1589a. With the increased number of certified and reference concentration values for PCBs and the inclusion of certified and reference concentration values for PBDEs, this serum material will be more useful as a reference material for contaminant monitoring in human tissues and fluids. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

6.
The reactivity of a series of commonly used halogenated compounds (trihalomethanes, chlorofluorocarbon, hydrochlorofluorocarbon, fluorocarbons, and hydrofluoroolefin) with hydroxide and oxygen anion is studied in a compact Fourier transform ion cyclotron resonance. O is formed by dissociative electron attachment to N2O and HO by a further ion‐molecule reaction with ammonia. Kinetic experiments are performed by increasing duration of introduction of the studied molecule at a constant pressure. Hydroxide anion reactions mainly proceed by proton transfer for all the acidic compounds. However, nucleophilic substitution is observed for chlorinated and brominated compounds. For fluorinated compounds, a specific elimination of a neutral fluorinated alkene is observed in our results in parallel with the proton transfer reaction. Oxygen anion reacts rapidly and extensively with all compounds. Main reaction channels result from nucleophilic substitution, proton transfer, and formal H2+ transfer. We highlight the importance of transfer processes (atom or ion) in the intermediate ion‐neutral complex, explaining part of the observed reactivity and formed ions. In this paper, we present the first reactivity study of anions with HFO 1234yf. Finally, the potential of O and HO as chemical ionization reagents for trace analysis is discussed.  相似文献   

7.
Increased interest in the fate, transport and toxicity of polybrominated diphenyl ethers (PBDEs) over the past few years has led to a variety of studies reporting different methods of analysis for these persistent organic pollutants. Because PBDEs encompass a range of vapor pressures, molecular weights and degrees of bromine substitution, various analytical methods can lead to discrimination of some PBDE congeners. Recent improvements in injection techniques and mass spectrometer ionization methods have led to a variety of options to determine PBDEs in environmental samples. The purpose of this paper is therefore to review the available literature describing the advantages and disadvantages in choosing an injection technique, gas chromatography column and detector. Additional discussion is given to the challenges in measuring PBDEs, including potential chromatographic interferences and the lack of commercial standards for higher brominated congeners, which provides difficulties in examining degradation and debromination of BDE congeners, particularly for BDE 209.  相似文献   

8.
Current procedures for the evaluation of spectral accuracy of mass spectrometers are limited by the lack of certified isotopic reference materials and the high uncertainty in the isotopic composition of natural abundance molecules. The calculated uncertainties in the ratio M + 1/M for natural abundance molecules containing any number of C, H, N and/or O atoms are close to 5% relative because of the natural variability of the isotopic composition of carbon. So, we have developed two alternative measurement procedures with much lower theoretical uncertainties for a better evaluation of spectral accuracy in both single and triple quadrupole analysers. The first method is based on the measurement of the M + 2/M, M + 4/M + 2, etc. ratios for halogenated organic compounds containing either Cl or Br. The theoretical uncertainties for these ratios because of natural variability are in the order of 0.3 to 1.0% making them suitable for the evaluation of spectral accuracy with the additional advantage that there is no need to take into account other limitations such as cluster purity or poor mass resolution. This procedure was applied to the evaluation of a single quadrupole GC‐MS instruments using natural abundance PCB and PBDE standards with satisfactory results. The second method can be applied to tandem instruments and takes advantage of the loss of two halogen atoms when PCB and PBDE standards are fragmented by Collision Induced Dissociation. Theoretical SRM transition ratios can be calculated as a pure combinatorial probability with theoretical uncertainties lower than 0.1%. By combining PCBs and PBDEs with different number of halogen atoms, a mass range from 100 to 700 u and abundance ratios from 0.1 to 10 can be evaluated. The use of penta‐chlorinated PCBs and/or penta‐brominated PBDEs is finally recommended for the evaluation of spectral accuracy of mass spectrometers with the EI source. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
建立了气相色谱-负离子化学电离质谱法(GC-NCI/MS)同时分析深海鱼油食品中5种多溴联苯醚残留的分析方法。深海鱼油食品用正己烷超声提取、中性与酸性硅胶色谱柱净化和正己烷洗脱后,以PCB103为内标物,采用GC-NCI/MS的选择离子监测方式(SIM)分析;同时探讨了5种多溴联苯醚的NCI/MS特征离子的断裂机理。当空白深海鱼油食品的加标浓度为20.0和100.0 μg/kg时,加标回收率为88.6%~111.3%,相对标准偏差为3.8%~13.5%,方法的检测限为0.77~1.34 μg/kg,线性范围为1.0~500.0 μg/kg,相关系数均大于0.9992。此方法已成功地应用于深海鱼油食品中5种痕量多溴联苯醚残留的同时分析。  相似文献   

10.
Two different gas chromatographic detectors, the helium ionization detector (HID) and the more commonly used flame ionization detector (FID), were used in parallel to compare their responses to a number of organic compounds. Atmospherically important oxygenated species were analyzed, as well as hydrocarbons and chlorinated and sulfur containing organics. The HID exhibited the better response to all compounds investigated, most notably to formaldehyde and higher oxygenates. A gas chromatographic system was developed to trap and analyze atmospheric organic compounds with HID detection. This required careful choice of the adsorbent material and removal of inorganic components (namely nitrogen and oxygen) before analysis. Real air samples were then taken and analyzed qualitatively for a range of olefinic and aromatic compounds.  相似文献   

11.
Several recent reports indicate that both toxaphene (polychlorocamphene, PCC) and chlordane are widespread pollutants in our environment. These insecticides, both complex mixtures of chlorinated hydrocarbons, are difficult to separate from each other. Thus the analyses of them in environmental samples are difficult and furthermore complicated by interferences from other chlorinated hydrocarbons such as PCB and DDT compounds. Mass fragmentography using the negative ions formed by chemical ionization proved to be useful to selectively detect the toxaphenes and the chlordanes without interferences from DDT. High concentrations of PCB still influence on the results and have to be removed in the clean-up procedure.  相似文献   

12.
Separations of 12 compound classes, polychlorinated biphenyls (PCBs), diphenyl ethers (PCDEs), naphthalenes (PCNs), dibenzothiophenes (PCDTs), dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), terphenyls (PCTs) and alkanes (PCAs), toxaphene, organohalogenated pesticides (OCPs), and polybrominated biphenyls (PBBs) and diphenyl ethers (PBDEs) by comprehensive two-dimensional gas chromatography were evaluated. Five column combinations, DB-1 x 007-210, DB-1 x HT-8, DB-1 x LC-50, DB-1 x 007-65HT and DB-1 x VF-23ms were used to study, primarily, group-type separations, but attention was devoted also to within-class separation, especially for those classes which were not addressed in much detail before, the PCNs, OCPs, PBBs and PCTs. The DB-1 x 007-210 column set did not offer any extra separation compared to one-dimensional GC. For the DB-1 x HT-8 column combination, the useful principle of congener separation on the basis of number of halogen substituents in a molecule was confirmed (PCBs, toxaphene) and extended (PCTs, PBDEs). No practically useful group-type separation was observed for this column combination. The DB-1 x LC-50 set provides group separation based on planarity: planar compounds such as PCDDs, PCDFs, PCDTs and PCNs are much more retained than, and therefore separated from, non-planar analytes. Within the classes of PCBs, PBBs and PCTs highly useful separation of planar from non-planar compounds was also observed. The DB-1 x 007-65HT column set effectively separates PCAs and PBDEs from all other compound classes, and provides a good separation of brominated and chlorinated analogue classes from each other. This column set was the most efficient one for within-class separation of OCPs and PCNs. Finally, DB-1 x VF-23ms yields excellent within-class separations, especially of non-aromatic compounds, viz. OCPs, toxaphene and PCAs. No group separation was observed here. The applicability of the approach was demonstrated for a sediment extract and a dust extract. In the sediment extract, PCDDs, PCDFs, PCAs and PCNs were identified and their efficient separation was achieved. In the dust sample, separation of PCAs and PBDEs was achieved and several new PBDE congeners were identified.  相似文献   

13.
Abstract

Several recent reports indicate that both toxaphene (polychlorocamphene, PCC) and chlordane are widespread pollutants in our environment. These insecticides, both complex mixtures of chlorinated hydrocarbons, are difficult to separate from each other. Thus the analyses of them in environmental samples are difficult and furthermore complicated by interferences from other chlorinated hydrocarbons such as PCB and DDT compounds. Mass fragmentography using the negative ions formed by chemical ionization proved to be useful to selectively detect the toxaphenes and the chlordanes without interferences from DDT. High concentrations of PCB still influence on the results and have to be removed in the clean-up procedure.  相似文献   

14.
Simultaneous determination of PCDDs, PCDFs, PCBs and PBDEs in food   总被引:4,自引:0,他引:4  
Fernandes A  White S  D'Silva K  Rose M 《Talanta》2004,63(5):1147-1155
Established and comprehensively validated methodology for the analysis of PCDDs, PCDFs and polychlorinated biphenyls (PCBs) in food, animal feed and other matrices is presented. The method achieves the analytical standards of EU protocols (2002/69/EC and 2002/70/EC) that are used to determine the compliance of food and animal feed to maximum permissible levels of chlorinated dioxins in these commodities. The methodology provides WHO–TEQ data for dioxins and PCBs as well as individual concentrations for toxic PCDD/F congeners and >50 commonly occurring PCBs. In addition, the methodology allows the simultaneous determination of individual polybrominated diphenylether (PBDE) congeners. A wide range of 13Carbon-labelled surrogates allow accurate internal standardisation, and measurements are carried out using high resolution GC coupled to high resolution mass spectrometry except for mono-, tetra, ortho-substituted PCBs where unit resolution mass spectrometry can be used instead. Evidence of internal as well as external validation through the frequent use of reference materials, and successful participation in international inter-comparison exercises over many years is presented. A large number of different food types have been analysed for dioxins and PCBs using this methodology over several years and typical congener profiles for various food matrices are discussed.  相似文献   

15.
A new LC-MS-MS method for quantitative analysis of nonylphenol (NP), nonylphenol carboxylates (NPECs), and their halogenated derivatives: brominated and chlorinated nonylphenols (BrNP, ClNP), brominated and chlorinated nonylphenol carboxylates (BrNPE(1)C and ClNPE(1)C) and ethoxycarboxylates (BrNPE(2)C and ClNPE(2)C) in water and sludge has been developed. Electrospray negative ionization MS-MS was applied for the identification of above mentioned compounds. Upon collision-induced dissociation, their deprotonated molecules gave different fragments formed by the cleavage of the alkyl moiety and/or (ethoxy)carboxylic moiety. For halogenated compounds a highly diagnostic characteristic pattern of isotopic doublet signals was obtained and fragmentation yielded, in addition to above mentioned ions, [Br](-) and [Cl](-), respectively. Quantitative analysis was done in the multiple reaction monitoring (MRM) mode, using two specific combinations of a precursor-product ion transitions for each compound. Additionally, for halogenated compounds two specific channels for each transition reaction, corresponding to two isotopes, were monitored and the ratio of their abundances used as an identification criterion. The method has been validated in terms of sensitivity, selectivity, accuracy, and precision and was applied to the analysis of water and sludge samples from drinking water treatment plant (DWTP) of Barcelona (Catalonia, NE Spain). Halogenated NP and NPECs were detected in prechlorinated water in concentrations up to 315 ng/L, BrNPE(2)C being the most abundant compound. In the DWTP effluent non-halogenated compounds were detected at trace levels (85, 12 and 10 ng/L for NP, NPE(1)C, and NPE(2)C, respectively), whereas concentration of halogenated derivatives never exceeded 10 ng/L. Nonylphenol, brominated and chlorinated NPs were found in flocculation sludge in concentrations of 150, 105, and 145 microg/kg, respectively. Acidic polar metabolites were found in lower concentrations up to 20 microg/kg.  相似文献   

16.
Summary A multiresidue method for the analysis of a number of chlorinated and brominated organic compounds in biological samples has been developed. The method includes gas-chromatographic analysis of hexachlorinated and hexabrominated benzenes (HCB and HBB), polychlorinated and polybrominated biphenyls (PCB and PBB), polychlorinated phenols (PCP), guaiacols (PCG), paraffins (CP) and naphthalenes (PCN), polybrominated diphenyl ethers (PBDE) and the pesticides DDT, polychlorinated terpenes (PCC or toxaphene), chlordanes, hexachlorocyclohexanes (HCH), aldrin and dieldrin. The use of charcoal column in the clean-up procedure makes it also possible to analyze the planar PCB congeners (pPCB). Cod muscle samples were spiked with 10 and 50 times the detection levels of the compounds to be analyzed. The mean recoveries, relative to internal standards, for 40 compounds or compound groups were between 51 and 120%.  相似文献   

17.
Polychlorinated biphenyls (PCBs) are hazardous compounds for which there are few methods involving real-time measurement. Recently, the development of the pulsed-laser technique has enabled us to measure aromatic hydrocarbons quite rapidly. In particular, the LI-TOFMS (laser ionization time of flight mass spectrometry) technique is expected to be a powerful method for on-line, selective and sensitive measurements. In the context of developing a highly selective and sensitive technique, the effective laser wavelength and pulse duration for laser ionization of 2-4 chlorinated PCBs are considered. Excitation at lambda = 266 nm was found to be substantially more effective than at lambda = 280, 300 or 320 nm. Also, picosecond excitation for PCBs underwent more efficient ionization (by a factor of over 10) and less fragmentation than nanosecond excitation. The achievable sensitivity for trichlorinated biphenyl in a real-time (1 min) measurement using the LI-TOFMS technique was estimated to be in the sub-ppbV range (< 0.01 mg/Nm3).  相似文献   

18.
Fast gas chromatography/negative-ion chemical ionization mass spectrometric (GC/NICI-MS) assay combined with rapid and nonlaborious sample preparation is presented for the simultaneous determination of benzodiazepines and alpha-hydroxy metabolites, zaleplon and zopiclone in whole blood. The compounds were extracted from 100 microl of whole blood by simultaneous multitube, microscale liquid-liquid extraction (LLE) and derivatized by N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA), without the need for the time-consuming concentration stage. In the analytical separation, various parameters of fast GC/NICI-MS were applied, e.g. the use of hydrogen as a GC carrier gas, a high carrier gas velocity, a small film thickness of the analytical column, fast MS data acquisition, fast temperature ramping, and high initial and final temperatures of GC column. Sensitive identification, screening and quantitation of 18 compounds of interest were achieved in chromatographic separation in only 4.40 min. Accurate and reproducible results were obtained by using five different and carefully selected deuterated analogues on the basis of the chemical properties of the target analytes. Nevertheless, for alpha-OH-midazolam, and for bromazepam and flunitrazepam at low concentrations, the results can be considered only semiquantitative on the basis of the validation data. The extraction efficiencies ranged from 74.3 to 105.7% and the limits of quantitation (LOQ) from 1 to 100 ng ml(-1). Rapid sample preparation and fast chromatographic separation allowed cost-efficient, reliable and high sample-throughput analyses with a low amount of manual work. The method was fully validated and accredited according to EN ISO/IEC 17025 standards and is applicable for sensitive, reliable and quantitative determination of benzodiazepines, zaleplon and zopiclone, e.g. in clinical and forensic toxicology.  相似文献   

19.
采用全二维气相色谱/飞行时间质谱(GC×GC-TOFMS),建立了鱼肉样品中含卤有机污染物的定性和定量分析方法.鱼肉样品用正己烷丙酮(1∶1,V/V)提取,凝胶色谱和复合硅胶柱净化,浓缩富集,全二维气相色谱联用飞行时间质谱(DB-5MS毛细管色谱柱联HT-8色谱柱)检测.软件自动识别后,经三步筛查,共鉴定出含氯或溴化合物72种,其中包括33种多氯联苯,9种有机氯农药,4种多溴联苯醚,4种DDT代谢产物,2种氯代茴香醚,2种氯苯乙烯,1种氯代茴香硫醚及1种甲基三氯生.另外,从质谱信息上看,有16种化合物明显含氯或含溴,但是因为缺少必要的谱库信息不能准确识别.采用外标定量法,对鱼肉样品中检出的主要的10种多氯联苯和1种多溴联苯醚进行了准确定量分析.  相似文献   

20.
This work presents an exploratory study of the photochemical degradation process of decabromodiphenyl ether (decaBDE) and gives an interpretation of the kinetic pathway, species and effects of the key factors involved in the degradation process. Use of lowly brominated diphenyl ethers (PBDE) has been banned by the EU and there seems to be evidence of the photolytic degradation of highly brominated PBDEs into lowly brominated congeners. Hence, the importance of knowing the photodegradation process of decaBDE.The photodegradation was investigated under UV light by UV-spectrophotometric monitoring. A novel hybrid data analysis approach, based on the combination of hard- and soft-spectrophotometric multivariate curve resolution, was applied to elucidate the mechanism of the degradation process, to resolve kinetic profiles and pure spectra of the photodegradation products and to evaluate the rate constants. The photodegradation process could be described with a kinetic model based on three consecutive first-order reactions and a decrease of the degradation process was observed as solvent polarity increased. Complementary identification of photodegradation products by gas chromatography coupled to mass spectrometry using negative chemical ionization (GC-NCI-MS) is attempted.This work presents a novel attempt of describing in a comprehensive way the photochemical degradation process of decaBDE, with all successive steps and related rate constants. This study proves also the potential of the proposed hybrid data analysis methodology as a general strategy to interpret the evolution of these photochemical reactions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号