首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A system for on-line preconcentration and determination of platinum by ultrasonic nebulization (USN) coupled to inductively coupled plasma optical emission spectrometry (ICP-OES) was studied. It is based on the chemical sorption of platinum on a column packed with polyurethane foam loaded with thiocyanate reagent. The optimization step was carried out using two level full factorial design. Three variables (pH, loading flow rate (LFR) and eluent concentration) were regarded as factors in the optimization. Results of the two level factorial design 23 with three replicates of the central point for platinum preconcentration, based on the variance analysis (ANOVA), demonstrated that the factors and their interactions are not statistically significant. The proposed procedure allowed the determination of platinum with a detection limit of 0.28 μg l−1. The precision for 10 replicate determinations at 10.0 μg l−1 Pt level was 3.8% relative standard deviation (R.S.D.), calculated from the peak heights obtained. A total enhancement factor of 100 was obtained with respect to ICP-OES using pneumatic nebulization (10 for USN and 10 for preconcentration). A sampling frequency of 50 samples per hour was obtained. The effect of other ions in concentrations agreeing with water samples was studied. The addition/recovery experiments in the samples analyzed demonstrated the accuracy and applicability of the system developed for platinum determination in spiked water samples.  相似文献   

2.
The use of aerosol produced in a nebulization chamber is proposed as an alternative to gas sample capture in flow systems. This paper describes the coupling of a sampling interface with a flow system, for in situ gas monitoring. Aspects related with the behavior of aerosol formation and gas solubilization in liquid drops are discussed. The method is applied to the determination of residual lime in acidic soils. Aliquots of 5.0 ml of 1.0 mol l−1 HCl were mixed with soil samples (1 g). The CO2 released from these samples was captured by a nebulized aerosol and determined conductivity. The analytical curve from 1.0×10−2 to 5.0×10−2 mol kg−1 CaCO3 was ploted applying the matrix matching approach. This proposition, allowed an increase in the sensibility with detection limit of 6.0×10−3 mol kg−1. The precision was good (R.S.D. <3%) for an analytical frequency of 22 determinations per hour. A fair agreement, at 95% confidence level, was found between the results from the proposed method and certified values of the investigated samples.  相似文献   

3.
A cross-flow atmospheric plasma jet with distilled water or analyte solution nebulization has been investigated. The plasma gas flows perpendicularly to the RF powered electrode (11.21 MHz) and a grounded electrode was added for plasma stabilization. The working parameters of the plasma generator can be controlled in order to maximize either the plasma power (75 W) or the voltage on the RF powered electrode (plasma power, 40 W). The plasma gas, pure argon (0.4 l min1) or a mixture of argon (0.3–0.4 l min1) and helium (0–0.2 l min1), was also used for liquid nebulization. Optical emission of the plasma, collected in the normal viewing mode, was used for plasma diagnostics and for evaluating its excitation capabilities. The influence of helium content in the mixed-gas plasma on the plasma characteristics and on the emission axial profiles of the plasma gas constituents and of the analytes originate from the wet aerosol was studied. The addition of helium to the argon plasma, generally determines decreases in the emission of the plasma gas constituents (with the exception of molecular nitrogen), in the rotational temperature and in the electron number density and increases in the excitation temperatures and in the emission of easily excitable analytes. Based on the determined electron number densities, it was concluded that in the plasma zone which presents interest from analytical point of view the plasma is not very far from the partial thermodynamic equilibrium. In function of the helium content in the plasma gas and of the axial distance from the powered electrode the excitation temperatures are in the range of 2420–3340 K for argon, 2500–5450 K for oxygen and 900–2610 K for ionic calcium and the electron number densities are in the range of 1.2 1012–1.25 1013 cm3. Some elements with excitation energy lower than 6 eV were excited in the plasma. The plasma excitation capability depends on the working conditions of the plasma generator (maximum power or maximum voltage on the RF powered electrode) and on the helium content in the mixed-gas plasma. The estimated detection limits for the studied elements (Na, Li, K, Ca, Cu, Ag, Cd, Hg and Zn) are in the range of 7 ng ml1 to 28 μg ml1.  相似文献   

4.
The effects and benefits of N2 addition to the central channel of the ICP through the nebulizer gas used in ICP OES with axial view configuration were investigated in the present study. The N2 flow rate, nebulizer gas flow rate, RF power and sample uptake rate were evaluated and compared for two sample introduction systems (pneumatic nebulization/aerosol desolvation and conventional pneumatic nebulization). It was observed that N2 did not affect solution nebulization and aerosol transport but affects the ICP characteristics. The higher thermal conductivity of N2 (in comparison with Ar) changes energy distribution in the ICP, observed by monitoring the signals of Ar emission lines and sodium emission. The ratio Mg(II)-280.270 nm/Mg(I)-285.213 nm was utilized as a diagnostic tool for plasma robustness. The addition of N2 (20 mL min−1) increased plasma robustness significantly and mitigated effects caused by Na, K and Ca. For 40 spectral lines evaluated, it was observed that the emission signals of ionic spectral lines were in general more affected by N2 than those of atomic spectral lines. Detection limits, precision, sensitivity and linearity of calibration curves obtained using N2-Ar-ICP were almost similar to those obtained using Ar-ICP. The analysis of 5 different reference materials revealed that accuracy was not degraded by adding N2 to the Ar-ICP.  相似文献   

5.
Cortada C  Vidal L  Canals A 《Talanta》2011,85(5):2546-2552
A fast, simple, inexpensive, sensitive, efficient and environmental friendly direct ultrasound-assisted dispersive liquid-liquid microextraction (DUSA-DLLME) procedure has been developed to concentrate five nitroaromatic explosives from water samples prior to quantification by gas chromatography-mass spectrometry (GC-MS). An efficient ultrasonic probe has been used to radiate directly the samples producing very fine emulsions from immiscible liquids. A D-optimal design was used for optimizing the factors and to evaluate their influential upon extraction. The optimum experimental conditions were: sample volume, 10 mL; extraction time, 60 s; cycles, 0.6 s(s−1); power of ultrasound energy, 40% (70 W); and, extractant solvent (chlorobenzene) volume, 20 μL. Under the optimized experimental conditions the method presents good level of repeatability with coefficients of variation under 6% (n = 8; spiking level 10 μg L−1). Calculated calibration curves gave high level of linearity with correlation coefficient values between 0.9949 and 0.9992. Limits of detection were ranged between 0.03 and 0.91 μg L−1. Finally, the proposed method was applied to the analysis of two types of water samples, reservoir and effluent wastewater. The samples were previously analysed and confirmed free of target analytes. At 5 μg L−1 spiking level recovery values ranged between 75 and 96% for reservoir water sample showing that the matrix had a negligible effect upon extraction. However, a noticeable matrix effect (around 50% recovery) was observed for effluent wastewater sample. In order to alleviate this matrix effect, the standard addition calibration method was used for quantitative determination. This calibration method supplied recovery values ranged between 71 and 79%. The same conclusions have been obtained from an uncertainty budget evaluation study.  相似文献   

6.
1-Vinyl-3-octadecylimidazolium bromide ionic liquid [C18VIm]Br was prepared and used for the modification of mercaptopropyl-functionalized silica (Si-MPS) through surface radical chain-transfer addition. The synthesized octadecylimidazolium-modified silica (SiImC18) was characterized by thermogravimetric analysis (TGA), infrared spectroscopy (IR), 13C NMR and 29Si NMR spectroscopy and used as an extraction phase for the automated 96-blade solid phase microextraction (SPME) system with thin-film geometry using polyacrylonitrile (PAN) glue. The new proposed extraction phase was applied for extraction of aminoacids from grape pulp, and LC–MS–MS method was developed for separation of model compounds. Extraction efficiency, reusability, linearity, limit of detection, limit of quantitation and matrix effect were evaluated. The whole process of sample preparation for the proposed method requires 270 min for 96 samples simultaneously (60 min preconditioning, 90 min extraction, 60 min desorption and 60 min for carryover step) using 96-blade SPME system.  相似文献   

7.
A new and simple method was developed for preconcentration trace amount of gold in aqueous and mineral samples. The method was based on the sorption of gold on granular activated carbon (AC) in acidic medium (hydrochloric acid) and subsequently direct determination by graphite furnace atomic absorption spectrometry (GFAAS). A small particle of adsorbent was delivered to small volume of sample. After extraction, AC removed and analyzed directly by GFAAS. Several factors influencing the extraction efficiency, such as the hydrochloric acid concentration, sample volume and extraction time were studied as well as effect of potential interfering ions. The preconcentration factor 50 was obtained. The limit of detection (LOD) of gold in water and soil samples was 0.007 μg L− 1 and 0.9 ng g− 1, respectively. The proposed method was applied successfully to the determination of trace amount of gold in environmental and geological samples. In order to validate the developed method, two certified reference materials: Platinum Ore (SARM-7B) and Copper Ore Mill Heads (No. 330) were analyzed and the determined values obtained were in good agreement with the certified values and recovery was obtained in the range of 80-118%. The relative standard deviations (RSD) for the spiking levels of 0.5 μg L− 1 in the real samples was 4%, (n = 15).  相似文献   

8.
A low-flow air-cooled inductively coupled plasma (ICP) design for optical emission spectrometry (OES) with axial plasma viewing is described and an evaluation of its analytical capabilities in trace element determinations is presented. Main advantage is a total argon consumption of 0.6 L min−1 in contrast to 15 L min−1 using conventional ICP sources.The torch was evaluated in trace element determinations and studied in direct comparison with a conventional torch under the same conditions with the same OES system, ultrasonic nebulization (USN) and single-element optimization. A variety of parameters (x-y-position of the torch, rf power, external air cooling, gas flow rates and USN operation parameters) was optimized to achieve limits of detection (LOD) which are competitive to those of a conventional plasma source.Ionic to atomic line intensity ratios for magnesium were studied at different radio frequency (rf) power conditions and different sample carrier gas flows to characterize the robustness of the excitation source. A linear dynamic range of three to five orders of magnitude was determined under compromise conditions in multi-element mode. The accuracy of the system was investigated by the determination of Co, Cr, Mn, Zn in two certified reference materials (CRM): CRM 075c (Copper with added impurities), and CRM 281 (Trace elements in rye grass). With standard addition values of 2.44 ± 0.04 and 3.19 ± 0.21 μg g−1 for Co and Mn in the CRM 075c and 2.32 ± 0.09, 81.8 ± 0.4, 32.2 ± 3.9 for Cr, Mn and Zn, respectively, were determined in the samples and found to be in good agreement with the reported values; recovery rates in the 98-108% range were obtained. No influence on the analysis by the matrix load in the sample was observed.  相似文献   

9.
A simple and rapid procedure for extraction of chloramphenicol (CAP) in milk and analysis by high-performance liquid chromatography coupled with quadrupole mass spectrometry in tandem was developed. The method consisted of one step of liquid-liquid extraction using ethyl acetate and acidified water (10 mmol L−1 formic acid) and HPLC-MS/MS detection. CAP-D5 was used as internal standard. The method was validated according to Commission Decision 2002/657/EC. The calibration curves were linear, with typical r2 values higher than 0.98. Absolute recovery of CAP from milk proved to be more than 95%, however CAP-D5 absolute recovery was 75%. The method was accurate and reproducible, being successfully applied to the monitoring of CAP in milk samples obtained from the Brazilian market. Decision limit (CCα) was 0.05 ng mL−1 and detection capability (CCβ) was 0.09 ng mL−1.  相似文献   

10.
A high performance liquid chromatographic method with fluorimetric detection for the determination of aflatoxin M1 (AFM1) in milk has been optimized and validated according to Commission Decision 2002/657/EC by using the conventional validation approach. The procedure for determining selectivity, recovery, precision, decision limit (CCα), detection capability (CCβ) and ruggedness of the method has been reported. The results of the validation process demonstrate the agreement of the method with the provisions of Commission Regulation 401/2006/EC. The mean recovery calculated at three levels of fortification (0.5, 1.0, and 1.5-fold the MRL) was 91% and the maximum relative standard deviation value for the within-laboratory reproducibility was 15%. Limit of detection (LOD) and limit of quantitation (LOQ) values were 0.006 μg kg−1 and 0.015 μg kg−1 while the CCα and CCβ values were 0.058 μg kg−1 and 0.065 μg kg−1, respectively. The relative expanded measurement uncertainty of the method was 7%. The method was not affected by slight variations of some critical factors (ruggedness minor changes) as pre-treatment and clean-up of milk samples, thermal treatment and different storage conditions, as well as by major changes valued in terms of milk produced by different species (buffalo, goat and sheep). The method allowed accurate confirmation analyses of milk samples, resulted positive by the screening method. In fact, the Z-score values attained in a proficiency test round were well below the reference value of 1, proving the excellent laboratory performances.  相似文献   

11.
A homogeneous aggregation immunoassay involving the use of gold nanoparticles (AuNPs) and light scattering detection is described for soy protein determination in food samples. AuNPs act as enhancers of the precipitate that appears when the antigen-antibody complex is formed. The AuNPs-antibody conjugate has been synthesized by physical adsorption of polyclonal anti-soy protein antibodies onto the surface of commercial AuNPs with a nominal diameter of 20 nm. The direct assay is based on the reaction of the conjugate with soy protein, which reaches the equilibrium in about 10 min, and the measurement of the light scattering intensity at 530 nm, which is proportional to the analyte concentration. The dynamic range of the calibration graph is 0.2-20 μg mL−1 and the detection limit value is 65 ng mL−1. The precision, expressed as relative standard deviation, has been assayed at two different concentrations, 0.2 and 1 μg mL−1, giving values ranging from 4.7 to 5.9%. The interference of other proteins has been assayed. The usefulness of this method has been shown by its application to the analysis of fruit juice and “nonmilk yoghourt” samples. The results obtained with the proposed method are similar to those obtained by using a commercial ELISA kit, but the assay time is significantly shorter and the detection limit was about 10 times lower. A recovery study has been also performed, giving values in the range of 84.0-119.3%.  相似文献   

12.
The present work reports the development of a methodology for the direct determination of lead in high saline waters derived from petroleum exploration employing electrothermal atomic absorption spectrometry with permanent Ir-W and HF as modifiers. These waters, so-called produced waters, have complex composition containing several types of organic and inorganic substances. In order to attain best conditions (highest analytical signal besides lowest background) for the methodology studies about the effect of several variables and the convenient calibration strategy were performed. Also, the efficiency of other modification approaches was evaluated. At best conditions, pyrolysis and atomization temperature were 800 and 2200 °C, respectively, when the modifiers cited above were utilized. Obtained results indicate that, in this kind of sample, lead can be determined by standard addition method or employing external calibration with standard solutions prepared in 0.8 mol l−1 NaCl medium. In order to evaluate the accuracy of the procedure, a recovery test was performed with six spiked samples of produced waters. The detection limit, quantification limit and the relative standard deviation in 0.8 mol l−1 NaCl were also calculated and the values are 1.5 μg l−1, 5.0 μg l−1 and 5.0% (at 10 μg l−1 level), respectively.  相似文献   

13.
A wall-free detection method based on liquid junction in a capillary gap was proposed for laser-induced fluorescence (LIF) of capillary electrophoresis (CE). The capillary gap of the wall-free cell was fabricated by etching a 10-mm × 50-μm I.D. fused-silica capillary to obtain a polyimide coating sleeve, decoating about 6 mm at one end of both 50 μm I.D. separation and liquid junction capillary, inserting the treated capillary ends into the coating sleeve oppositely, fixing the capillaries with a gap distance of 140 μm by epoxy glue and removing the coating sleeve by burning. The theoretical model, experimental results and wall-free cell images indicated that the gap distance and applied voltage were main influence factors on the wall-free detection. Since the wall-free cell increased the absorption light path and avoided the stray light from the capillary wall, it improved the ratio of signal to noise and limit of detection (LOD) of CE-LIF. Three flavin compounds of riboflavin (RF), flavin mononucleotide sodium (FMN) and flavin adenine dinucleotide disodium (FAD) were used to evaluate the wall-free detection method. Compared with on-column cell, the LODs of the wall-free cell were improved 15-, 6- and 9-fold for RF, FMN and FAD, respectively. The linear calibration concentrations of the flavins ranged from 0.005 to 5.0 μmol/L. The column efficiency was in the range from 1.0 × 105 to 2.5 × 105 plates. The wall-free detection of CE-LIF was applied to the analysis of the flavins in spinach and lettuce leaves.  相似文献   

14.
Yang M  Yang Y  Qu F  Lu Y  Shen G  Yu R 《Analytica chimica acta》2006,567(2):211-217
Anilinemethyltriethoxysilane (AMTEOS) was first used as precursor as well as selective stationary phase to prepare the sol-gel derived anilinemethyltriethoxysilane/polydimethylsiloxane (AMTEOS/PDMS) solid-phase microextraction (SPME) fibers. The novel SPME fiber exhibits high extraction efficiency, good thermal stability and long lifetime compared with commercial SPME coatings. In addition, the phenyl groups in the porous layer can exhibit π-π interactions with aromatic compounds, such as monocyclic aromatic hydrocarbons (MAHs) and polycyclic aromatic hydrocarbons (PAHs). Therefore, SPME using the AMTEOS/PDMS sol-gel fiber coupled with GC-FID was recommended as a sensitive and selective method towards the analysis of these compounds in environmental water samples. The optimal extraction conditions were investigated by adjusting extraction time, salt addition, extraction temperature, and desorption time. The method showed linearity between 2 and 4000 μg l−1 for MAHs and 1 and 1000 μg l−1 for PAHs. The limit of detection (LOD) was 0.6-3.8 μg l−1for MAHs and 0.2-1.5 μg l−1 for PAHs. The novel AMTEOS/PDMS fiber was applied to extract small amount of aromatic compounds in wastewater and river water respectively. The recovery of the method was acceptable for quantitative analysis.  相似文献   

15.
A method based on the coupling microHPLC-microneb-ICPMS has been developed for Hg(II), MeHg+, EtHg+ and PhHg+ species. Gradient elution using methanol and l-cysteine at pH 3.0 allowed the chromatographic separation of all species in less than 13 min (total analysis time 15 min). The direct coupling of microLC to ICPMS through a Micromist nebulizer permits the analysis of environmental water without sample pretreatment and derivatization steps. Nebulizer type, organic modifier and column length were the main parameters tested. The methanol content and pH of the mobile phase greatly affected the retention time and sensitivity of the method. Key factors to obtain high signal to noise ratio, at concentrations below 1 μg L−1, were found to be the nebulization step and traces of Hg present in the complexing agent. A detailed optimization of carrier and make up gas flow rates have enabled the nebulization of the methanol gradient elution with good mass transport efficiency, low organic solvent loading into the plasma and excellent precision.The performance of the microHPLC-microneb-ICPMS method developed was evaluated on a surface water sample filtered (0.22 μm) and spiked with 0.5 μg L−1 (as Hg) of each species. Precision (R.S.D., n = 6) for all species of Hg varied from 0.5 to 2.1%. Detection limit, defined as three times the standard deviation (n = 6), ranged from 8 ng L−1 for EtHg+ to 32 ng L−1 for PhHg+ and was noticeably lower than those reported in previous LC-based methods. Accuracy was suitable with recoveries ranging from 85 to 100% when tested at two levels (0.5 and 10 μg L−1) in groundwater samples. Recovery was matrix affected when water samples of high salinity (depurated wastewater and seawater) were used.  相似文献   

16.
In this work, for the first time, capillary zone electrophoresis (CZE) technique combined with microwave-assisted extraction (MAE) was developed for the fast quantification of chlorogenic acid (CA) in tobacco residues. CA in tobacco residue samples were extracted by MAE technique, and then analyzed by CZE. As a new sample preparation method for tobacco residues, the MAE procedure is optimized, validated and compared with conventional methods including ultrasonic extraction (USE) and reflux extraction (RE). It is found that MAE gives the best result due to the highest extraction efficiency within shortest extraction time (only 4.0 min). Here, CA is determined by CZE based on the calibration curve of its authentic standard. The method linearity, detection limit, precision and recovery are studied. The results show that the combined MAE and CZE method has a linearity (R2 0.991, 0.003-0.5 mg ml−1), a limit of detection (0.003 mg ml−1), a limit of quantification (0.01 mg ml−1), good precision (R.S.D. = 4.28%) and a finer recovery (89.0%). The proposed method was successfully applied to the analysis of CA in tobacco residue samples. The experiment results have demonstrated that the CZE combined with MAE is a convenient, fast, economical and reliable method for the determination of CA in tobacco residues.  相似文献   

17.
A flow injection on-line sorption system was developed for the separation and preconcentration of traces of Ag, Cd, Co, Ni, Pb, U and Y from natural water samples with subsequent detection by ICP TOF MS. Simultaneous preconcentration of the analytes was achieved by complexation with the chelating reagent 1-phenyl-3-methyl-4-benzoylpyrazol-5-one immobilized on the inner walls of a (200 cm × 0.5 mm) PTFE knotted reactor. The analytes were eluted and transported to an axial ICP TOF MS system with 1% (v/v) HNO3 containing 0.3 μg l−1 of Rh as an internal standard using ultrasonic nebulization. The detection limits (3σ) varied from 0.3 ng l−1 for Y to 15.2 ng l−1 for Ni and the precision (R.S.D.) was better than 4%. Using a loading time of 90 s and a sample flow rate of 4.5 ml min−1, enhancement factors of 3-14 were obtained for the different analytes in comparison with their direct determination by ICP TOF MS with ultrasonic nebulization without preconcentration. The accuracy of the method was demonstrated by analysis of water based certified reference materials.  相似文献   

18.
The present work reports the development of a methodology for the direct determination of vanadium in high saline waters derived from offshore petroleum exploration employing electrothermal atomic absorption spectrometry. Such waters, usually called produced waters, present complex composition containing various organic and inorganic substances. In order to attain best conditions (highest sensitivity besides lowest background) for the methodology, studies about the effects of several variables (evaluation of pyrolysis and atomization temperatures, type of chemical modifier, concentration of modifier and pyrolysis time) and the convenient calibration strategy were performed. Best conditions were reached with the addition of 10 μg of NH4H2PO4 as chemical modifier employing pyrolysis (during 10 s) and atomization temperatures of 1500 and 2700 °C, respectively. Obtained results indicated that, in this kind of sample, vanadium can be determined by standard addition method or employing an external calibration approach with standard solutions prepared in 0.8 mol l−1 NaCl medium. In order to evaluate possible matrix interferences, a recovery test was performed with five spiked samples of produced waters. The limit of detection, limit of quantification and relative standard deviation in 0.8 mol l−1 NaCl medium were also calculated and the derived values were 1.9 μg l−1, 6.3 μg l−1 and 5.6% (at 10 μg l−1 level), respectively.  相似文献   

19.
A novel titania sol-gel coating, including tetrabutyl orthototitanat (TBOT) as initial alkoxide, triethanolamine (TEA) as stabilizer, nitric acid as acid catalyst, and polyethylene glycol (PEG, 6000) as binder was prepared for the first time on an anodized aluminium wire and subsequently applied to headspace solid phase microextraction (HS-SPME) of benzene, toluene, ethylbenzene and xylenes (BTEX) with gas chromatography flame ionization detection (GC-FID). The analytical characteristics of the proposed porous titania sol-gel derived TBOT/PEG/TEA (41.6:16.0:42.4) fiber were comparable with reported fibers. The extraction temperature, extraction time, effect of salt addition, desorption temperature and desorption time were optimized. Under the optimized conditions and for all BTEX components, the linearity was from 20 to 800 μg L−1, the RSD was below 8.2% and limit of detections (LODs) were between 5.4 and 14.8 μg L−1. The recovery values were from 86.7% to 94.2% in water samples. The proposed HS-SPME-GC-FID method was successfully applied for the analysis of BTEX compounds from petrochemical wastewater samples.  相似文献   

20.
In this paper, an automatic method for the screening of water samples containing Cu(II) was proposed, based on peryoxalate chemiluminescence reaction using coproporphyrin I as fluorophor compound to provide selectivity and a simple flow injection (FI) chemiluminescence detector (CLD). FI system conditions were chosen in order to distinguish samples over or under legislation limit established (50 μg l−1) with high reliability. The detection limit found was 9 μg l−1 and the linear dynamic range was 15-125 μg l−1 of Cu(II). Repeatibility and reproducibility studies gave good precision and accuracy with recovery near 100%. Under these conditions, the method resulted selective and only Fe(II), Fe(III) and Pb(II) could interfere, but at a concentration level higher than their normal concentration in waters. The proposed method was found to be highly reliable for screening purposes and it was successfully applied to the screening of a variety of real water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏