首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Besides protein identification via mass spectrometric methods, protein and peptide quantification has become more and more important in order to tackle biological questions. Methods like differential gel electrophoresis or enzyme-linked immunosorbent assays have been used to assess protein concentrations, while stable isotope labeling methods are also well established in quantitative proteomics. Recently, we developed metal-coded affinity tagging (MeCAT) as an alternative for accurate and sensitive quantification of peptides and proteins. In addition to absolute quantification via inductively coupled plasma mass spectrometry, MeCAT also enables sequence analysis via electrospray ionization tandem mass spectrometry. In the current study, we developed a new labeling approach utilizing an iodoacetamide MeCAT reagent (MeCAT-IA). The MeCAT-IA approach shows distinct advantages over the previously used MeCAT with maleinimide reactivity such as higher labeling efficiency and the lack of diastereomer formation during labeling. Here, we present a careful characterization of this new method focusing on the labeling process, which yields complete tagging with an excess of reagent of 1.6 to 1, less complex chromatographic behavior, and fragmentation characteristics of the tagged peptides using the iodoacetamide MeCAT reagent.  相似文献   

2.
Mass spectrometry has arguably become the core technology for the characterization of food proteins and peptides. The application of mass spectrometry-based techniques for the qualitative and quantitative analysis of the complex protein mixtures contained in most food preparations is playing a decisive role in the understanding of their nature, structure, functional properties and impact on human health. The application of mass spectrometry to protein analysis has been revolutionized in the recent years by the development of soft ionization techniques such as electrospray ionization and matrix assisted laser desorption/ionization, and by the introduction of multi-stage and ‘hybrid’ analyzers able to generate de novo amino acid sequence information. The interfacing of mass spectrometry with protein databases has resulted in entirely new possibilities of protein characterization, including the high sensitivity mapping (femtomole to attomole levels) of post-translational and other chemical modifications, protein conformations and protein–protein and protein–ligand interactions, and in general for proteomic studies, building up the core platform of modern proteomic science. MS-based strategies to food and nutrition proteomics are now capable to address a wide range of analytical questions which include issues related to food quality and safety, certification and traceability of (typical) products, and to the definition of the structure/function relationship of food proteins and peptides. These different aspects are necessarily interconnected and can be effectively understood and elucidated only by use of integrated, up-to-date analytical approaches. In this review, the main aspects of current and perspective applications of mass spectrometry and proteomic technologies to the structural characterization of food proteins are presented, with focus on issues related to their detection, identification, and quantification, relevant for their biochemical, technological and toxicological aspects.  相似文献   

3.
Proteomics separates and analyzes proteins for investigation at the cellular level in regard to disease processing by analyzing the proteins’ expression, function, structure, post-translational modification, and protein–protein interaction. In general forensic investigations, the postmortem interval was evaluated by measuring changes in body temperature after death, along with forensic entomological knowledge. These investigations may be restrictive and subjective because of external factors. The objectives of this study are to sort biomarker candidates and develop a direct postmortem-interval characterization method using proteomics through analyzing and tracking down proteins in the deceased that change in accordance with the postmortem interval. The liver and heart tissues of rats were collected for protein extraction in the 24-h interval following death, and two-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis analysis was conducted based on the isoelectric point and the molecular weight for separation. To validate protein spot changes on the gel, the stained electrophoresis gels were scanned and converted to digital images. Through image analysis, 14 liver proteins and 12 heart proteins were sorted and classified into four groups based on pattern changes. These proteins containing spots were extracted from the gel and analyzed by high-performance liquid chromatography with tandem mass spectrometry. Finally, 26 protein postmortem-interval relevant biomarker candidates were identified using software. Some of the proteins were muscle proteins while others were oxidation-related proteins. This study presents a new approach to the postmortem-interval research using proteomics and could be substituted for postmortem-interval evaluation.  相似文献   

4.
利用生物传感芯片质谱法(BIA/MS)对微球蛋白及其抗体的相互作用进行分析和鉴定.将微球蛋白抗体偶联到芯片上,让微球蛋白溶液流过芯片表面,然后使用“三明治”结构的微再生方法把结合的微球蛋白从芯片上洗脱下来,再对其进行酶解及质谱鉴定,在10-15mol水平得到了明确的结果.  相似文献   

5.
High-density lipoproteins (HDLs) isolated by immunoaffinity chromatography and separated by immobilized pH gradient-isoelectric focusing (IPG-IEF) were examined by mass spectrometry directly, applying a new proteomics technology, virtual two-dimensional (2-D) gel electrophoresis. A preliminary examination of HDL particles has revealed at least 42 unique masses for protein species with isoelectric points between pH 5.47-5.04, some of which have not been observed previously. By delivering masses of intact proteins from complex cellular mixtures in a format that correlates directly to classical 2-D gel analyses, virtual 2-D gel electrophoresis constitutes a general discovery tool to expose and monitor protein isoforms and post-translational modifications. Furthermore, its general ability to deliver ions from sub-picomole level proteins enmeshed in complex cellular mixtures potentially fulfills the need of top-down proteomics to obtain intact protein ions from microscale samples. Additional comparison of such data to 2-D gel analyses and their identified proteins may elucidate the functions of the individual apolipoprotein components and the cardioprotective effects of HDL.  相似文献   

6.
The patterns of gene expression, post-translational modifications, protein/biomolecular interactions, and how these may be affected by changes in the environment, cannot be accurately predicted from DNA sequences. Approaches for proteome characterization are generally based upon mass spectrometric analysis of in-gel digested two dimensional polyacrylamide gel electrophoresis (2-D PAGE) separated proteins, allowing relatively rapid protein identification compared to conventional approaches. This technique, however, is constrained by the speed of the 2-D PAGE separations, the sensitivity limits intrinsic to staining necessary for protein visualization, the speed and sensitivity of subsequent mass spectrometric analyses for identification, and the limited ability for accurate quantitative measurements based on differences in spot intensity. We are presently developing alternative approaches for proteomics based upon the combination of fast capillary electrophoresis, or other suitable chromatographic separations, and the high mass accuracy and sensitivity obtainable with unique Fourier transform ion cyclotron resonance (FTICR) mass spectrometers available at our laboratory. Several approaches are presently being pursued; one based upon the analysis of intact proteins and the second upon approaches for global protein digestion and accurate peptide mass analysis. Quantitation of protein/peptide levels are based on using two or more stable-isotope labeled versions of proteomes which are combined to obtain precise quantitation of relative protein abundances. We describe the status of our efforts towards the development of a high-throughput proteomics capability and present initial results for application to several microorganisms and discuss our efforts for extending the developed capability to mammalian proteomes.  相似文献   

7.
Protein identification: the origins of peptide mass fingerprinting   总被引:10,自引:0,他引:10  
Peptide mass fingerprinting (PMF) grew from a need for a faster, more efficient method to identify frequently observed proteins in electrophoresis gels. We describe the genesis of the idea in 1989, and show the first demonstration with fast atom bombardment mass spectrometry. Despite its promise, the method was seldom used until 1992, with the coming of significantly more sensitive commercial instrumentation based on MALDI-TOF-MS. We recount the evolution of the method and its dependence on a number of technical breakthroughs, both in mass spectrometry and in other areas. We show how it laid the foundation for high-throughput, high-sensitivity methods of protein analysis, now known as proteomics. We conclude with recommendations for further improvements, and speculation of the role of PMF in the future.  相似文献   

8.
Chemical analysis has long relied on instrumentation, from the simplest (eg, burets) to the more sophisticated (eg, mass spectrometers) to facilitate precision measurements. Regardless of their complexity, the development of a new instrumental device can be a valued approach to address problems in science. In this perspective, we outline the process of novel device design, from early phase conception to the manufacturing and testing of the tool or gadget. Focus is placed on the development of improved front‐end devices to facilitate protein sample manipulations ahead of mass spectrometry, which therefore augment the proteomics workflow. Highlighted are some of the many training secrets, choices, and challenges that are inherent to the often iterative process of device design. In hopes of inspiring others to pursue instrument design to address relevant research questions, we present a summary list of points to consider prior to innovating their own devices.  相似文献   

9.
The recent completion of the first rough draft of the human genome has provided fundamental information regarding our genetic make-up; however, the post-genome era will certainly require a host of new technologies to address complex biological questions. In particular, a rapid and accurate approach to characterize genetic markers, including short tandem repeats (STRs) and single nucleotide polymorphisms (SNPs) is demanded. STRs are the most informative of the two polymorphisms owing to their remarkable variability and even dispersity throughout eukaryotic genomes. Mass spectrometry is rapidly becoming a significant method in DNA analysis and has high probability of revolutionizing the way in which scientists probe the human genome. It is our responsibility as biomolecular mass spectrometrists to understand the issues in genetic analysis and the capabilities of mass spectrometry so that we may fulfill our role in developing a rapid, reliable technology to answer specific biological questions. This perspective is intended to familiarize the mass spectrometry community with modern genomics and to report on the current state of mass spectrometry, specifically electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry, for characterization of STRs.  相似文献   

10.
New and improved strategies are eagerly sought for the rapid identification of microorganisms, particularly in mixtures. Mass spectrometry remains a powerful tool for this purpose. Small acid-soluble proteins (SASPs), which are relatively abundant in Bacillus spores, represent potential biomarkers for species characterization. Despite sharing extensive sequence homology, these proteins differ sufficiently in sequence for discrimination between species. This work focuses on the differences in sequence between SASPs from various Bacillus species. Compilation of SASP sequences from protein database searches, followed by in silico trypsin digestion and analysis of the resulting fragments, identified several species-specific peptides that could be targeted for analysis using mass spectrometry. This strategy was tested and found to be successful in the characterization of Bacillus spores both from individual species and in mixtures. Analysis was performed using an ion trap mass spectrometer with an atmospheric pressure MALDI source. This instrumentation offers the advantage of increased speed of analysis and accurate precursor ion selection for tandem mass spectrometric analysis compared with vacuum matrix-assisted laser desorption/ionization and time-of-flight instruments. The identification and targeting of species-specific peptides using this type of instrumentation offers a rapid, efficient strategy for the identification of Bacillus spores and can potentially be applied to different microorganisms.  相似文献   

11.
Potential agents for biological attacks include both microorganisms and toxins. In mass spectrometry (MS), rapid identification of potential bioagents is achieved by detecting the masses of unique biomarkers, correlated to each agent. Currently, proteins are the most reliable biomarkers for detection and characterization of both microorganisms and toxins, and MS-based proteomics is particularly well suited for biodefense applications. Confident identification of an organism can be achieved by top-down proteomics following identification of individual protein biomarkers from their tandem mass spectra. In bottom-up proteomics, rapid digestion of intact protein biomarkers is again followed by MS/MS to provide unambiguous bioagent identification and characterization. Bioinformatics obviates the need for culturing and rigorous control of experimental variables to create and use MS fingerprint libraries for various classes of bioweapons. For specific applications, MS methods, instruments and algorithms have also been developed for identification based on biomarkers other than proteins and peptides.  相似文献   

12.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) has been used extensively for the analysis of -intact proteins and for proteomics. Proteins or proteomics analyses with low molecular mass range have some limitations because of background interference from the salt or surfactant ions. Lanthanum-calcium- manganate La(0.67)Ca(0.33)MnO(3) nanoparticles (LCMONPs) have been used as the matrix-assisting material after surface modification to reduce the salt or surfactant interference. The detectable mass range was tested in the range of 800-16,000 Da. The surface-modified LCMONPs have affinity with protein molecules through ionic or electrostatic interaction at pH 4.0. The nanoparticles mixed with proteins give a spectrum with a large signal-to-noise ratio for the analytes, and effectively eliminate the noise from interfering salt or surfactant ions. The results indicate that surface-modified La(0.67)Ca(0.33)MnO(3) nanoparticles can be used with MALDI matrix for proteins to eliminate the excessive noise of selective surfactants or salt ions from the MALDI spectrum.  相似文献   

13.
Over the past several years, a large effort has been focused on improvements of two-dimensional (2-D) gel electrophoresis-based proteomics technology, and on development of novel approaches for proteome analysis. Here, we describe the application of an alternative strategy for the analysis of complex proteomes. The strategy combines isoelectric focusing in immobilized pH gradient strips (in-gel IEF), mass spectrometry (MS), and bioinformatics. A protein mixture is separated by in-gel IEF, and the entire strip is cut into a set of gel sections. Proteins in each gel section are digested with trypsin, and the tryptic peptides are subjected to liquid chromatography-nanoelectrospray-quadrupole ion-trap tandem mass spectrometry (LC-ESI-MS/MS). The LC-ESI-MS/MS data are used to identify the proteins through searches of a protein sequence database. Using this in-gel IEF-LC-MS/MS strategy, we have identified 127 proteins from a human pituitary. This study demonstrates the potential of the in-gel IEF-LC-MS/MS approach for analyses of complex mammalian proteomes.  相似文献   

14.
Cui W  Rohrs HW  Gross ML 《The Analyst》2011,136(19):3854-3864
Top-down mass spectrometry is an emerging approach for the analysis of intact proteins. The term was coined as a contrast with the better-established, bottom-up strategy for analysis of peptide fragments derived from digestion, either enzymatically or chemically, of intact proteins. Although the term top-down originates from proteomics, it can also be applied to mass spectrometric analysis of intact large biomolecules that are constituents of protein assemblies or complexes. Traditionally, mass spectrometry has usually started with intact molecules, and in this regard, top-down approaches reflect the spirit of mass spectrometry. This article provides an overview of the methodologies in top-down mass spectrometry and then reviews applications covering protein posttranslational modifications, protein biophysics, DNAs/RNAs, and protein assemblies. Finally, challenges and future directions are discussed.  相似文献   

15.
Structural proteomics is the application of protein chemistry and modern mass spectrometric techniques to problems such as the characterization of protein structures and assemblies and the detailed determination of protein-protein interactions. The techniques used in structural proteomics include crosslinking, photoaffinity labeling, limited proteolysis, chemical protein modification and hydrogen/deuterium exchange, all followed by mass spectrometric analysis. None of these methods alone can provide complete structural information, but a "combination" of these complementary approaches can be used to provide enough information for answering important biological questions. Structural proteomics can help to determine, for example, the detailed structure of the interfaces between proteins that may be important drug targets and the interactions between proteins and ligands. In this review, we have tried to provide a brief overview of structural proteomics methodologies, illustrated with examples from our laboratory and from the literature.  相似文献   

16.
With advancements in ionization methods and instrumentation, liquid chromatography/mass spectrometry (LC/MS) has become a powerful technology for the characterization of small molecules and proteins. This article will illustrate the role of LC/MS analysis in drug discovery process. Examples will be given on high-throughput analysis, structural analysis of trace level impurities in drug substances, identification of metabolites, and characterization of therapeutic protein products for process improvement. Some unique MS techniques will also be discussed to demonstrate their effectiveness in facilitating structural identifications.  相似文献   

17.
The extent and effects of sequence scrambling in peptide ions during tandem mass spectrometry (MS/MS) have been examined using tryptic peptides from model proteins. Sequencescrambled b ions appeared in about 35% of 43 tryptic peptides examined under MS/MS conditions. In general, these ions had relatively low abundances with averages of 8% and 16%, depending on the instrumentation used. A few tryptic peptides gave abundant scrambled b ions in MS/MS. However, peptide and protein identifications under proteomic conditions with Mascot were not affected, even for these peptides wherein scrambling was prominent. From the 43 tryptic peptides that have been investigated, the conclusion is that sequence scrambling is unlikely to impact negatively on the accuracy of automated peptide and protein identifications in proteomics.  相似文献   

18.
Direct mass spectrometric analysis of complex biological samples is becoming an increasingly useful technique in the field of proteomics. Matrix-assisted laser desorption/ionization mass spectroscopy (MALDI-MS) is a rapid and sensitive analytical tool well suited for obtaining molecular weights of peptides and proteins from complex samples. Here, a fast and simple approach to cellular protein profiling is described in which mammalian cells are lysed directly in the MALDI matrix 2,5-dihydroxybenzoic acid (DHB) and mass analyzed using MALDI-time of flight (TOF). Using the unique MALDI mass spectral "fingerprint" generated in these analyses, it is possible to differentiate among several different mammalian cell lines. A number of techniques, including MALDI-post source decay (PSD), MALDI tandem time-of-flight (TOF-TOF), MALDI-Fourier transform ion cyclotron resonance (FTICR), and nanoflow liquid chromatography followed by electrospray ionization and tandem mass spectrometry (LC-ESI-MS/MS) were employed to attempt to identify the proteins represented in the MALDI spectra. Performing a tryptic digestion of the supernatant of the cells lysed in DHB with subsequent LC-ESI-MS/MS analysis was by far the most successful method to identify proteins.  相似文献   

19.
O-Fucosylation is an unusual posttranslational modification present in several proteins that play important roles in physiological processes such as coagulation, cell signaling and metastasis. Although the exact function of the modification is still unclear, the number of proteins found to be modified is increasing, and there is a need for further structural and functional analyses. Here we report on a rapid and straightforward approach in the analysis of glycosylation status and determination of glycosylation sites in O-fucosylated glycopeptides using nano-electrospray quadrupole time-of-flight (nano-ESI Q-TOF) mass spectrometry. In a single measurement of previously chemically untreated O-fucosylated peptides originating from the thrombospondin-1 repeats, we were able to determine the glycosylation status of the analyzed peptide, the glycosylation site, and the glycan structure. The abundance of glycosylated peptide fragment ions in MS(2) spectra suggests that nano-ESI Q-TOF mass spectrometry can be used as a general approach in structural studies of O-fucosylation in proteins.  相似文献   

20.
Mass spectrometry has evolved to a key technology in the areas of metabolomics and proteomics. Centralized facilities generate vast amount of data, which frequently need to be processed off‐site. Therefore, the distribution of data and software, as well as the training of personnel in the analysis of mass spectrometry data, becomes increasingly important. Thus, we created a comprehensive collection of mass spectrometry software which can be run directly from different media such as DVD or USB without local installation. MASSyPup is based on a Linux Live distribution and was complemented with programs for conversion, visualization and analysis of mass spectrometry (MS) data. A special emphasis was put on protein analysis and proteomics, encompassing the measurement of complete proteins, the identification of proteins based on Peptide Mass Fingerprints (PMF) or LC‐MS/MS data, and de novo sequencing. Another focus was directed to the study of metabolites and metabolomics, covering the detection, identification and quantification of compounds, as well as subsequent statistical analyses. Additionally, we added software for Mass Spectrometry Imaging (MSI), including hardware support for self‐made MSI devices. MASSyPup represents a ‘ready to work’ system for teaching or MS data analysis, but also represents an ideal platform for the distribution of MS data and the development of related software. The current Live DVD version can be downloaded free of charge from http://www.bioprocess.org/massypup . Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号