首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple batch method for the fluorometric determination of hydrogen peroxide using phosphine-based fluorescent reagents has been developed. A rapid, mild and selective derivatization reaction was achieved by adding sodium tungstate dihydrate to the reaction mixture of hydrogen peroxide and a phosphine-based fluorescent reagent. When 4-diphenylphosphino-7-methylthio-2,1,3-benzoxadiazole was used as a reagent, the derivatization reaction was completed after 2 min at room temperature. The calibration curve was linear between 12.5 and 500 ng hydrogen peroxide in a 10 microL sample solution. This method is accurate and has potential for on-line applications.  相似文献   

2.
A method for the determination of hydrogen peroxide and several organic peroxides by high-performance liquid chromatography with post-column UV irradiation, derivatization and fluorescence detection is described. By means of post-column UV irradiation in the presence of water organic peroxides are converted into hydrogen peroxide and organic hydroperoxides, which react rapidly with the post-column derivatization agent p-hydroxyphenylacetic acid (PHPAA) under catalysis of horseradish peroxidase to yield the fluorescent PHPAA dimer that is detected at excitation and emission wavelengths of 285 and 400 nm, respectively. The detection limit for hydrogen peroxide is 14 ng/mL, for organic peroxides between 34 ng/mL and 5 μg/mL. No interference by other compounds was observed when their concentrations were below 10 mg/mL except ethers and phenols. Received: 6 August 1997 / Revised: 11 December 1997 / Accepted: 15 December 1997  相似文献   

3.
A method for the determination of hydrogen peroxide and several organic peroxides by high-performance liquid chromatography with post-column UV irradiation, derivatization and fluorescence detection is described. By means of post-column UV irradiation in the presence of water organic peroxides are converted into hydrogen peroxide and organic hydroperoxides, which react rapidly with the post-column derivatization agent p-hydroxyphenylacetic acid (PHPAA) under catalysis of horseradish peroxidase to yield the fluorescent PHPAA dimer that is detected at excitation and emission wavelengths of 285 and 400 nm, respectively. The detection limit for hydrogen peroxide is 14 ng/mL, for organic peroxides between 34 ng/mL and 5 μg/mL. No interference by other compounds was observed when their concentrations were below 10 mg/mL except ethers and phenols. Received: 6 August 1997 / Revised: 11 December 1997 / Accepted: 15 December 1997  相似文献   

4.
A simple and sensitive fluorescent quenching method for the determination of trace hydrogen peroxide (H(2)O(2)) has been proposed to determine hydrogen peroxide in rain water sample. The method is based on the reaction of H(2)O(2) with 3,3'-diethyloxadicarbocyanine iodide (DI) to form a compound which has no fluorescence in acetate buffer solution (pH 3.09). The maximum emission wavelength of the system is located at 604 nm with excitation at 570 nm. Under the optimal conditions, the calibration graph was obtained between the quenched fluorescence intensity and hydrogen peroxide concentration in the range of 5.0 x 10(-7) to 9.0 x 10(-4) mol L(-1). The proposed method was applied to determine H(2)O(2) in rain water samples, and the result was satisfactory. The mechanism involved in the reaction was also studied.  相似文献   

5.
研究了铁(Ⅲ)催化H2O2氧化2-(5-羧基-1,3,4-三氮唑偶氮)-5-二乙氨基苯甲酸(CTZDBA)的褪色反应及其动力学条件,褪色反应程度与铁(Ⅲ)量在一定范围内呈线性关系,建立了测定痕量铁(Ⅲ)的催化动力学光度法。在pH4.0的HAc-NaAc缓冲溶液介质中,褪色体系的最大吸收波长581nm,Fe(Ⅲ)的质量浓度在0.0008~0.04μg/mL范围内符合线性关系,回归方程为ΔA=25.325ρ-8.02×10-3(ρ:μg/mL),相关系数为0.9977,检出限3.78×10-10g/mL,方法用于头发和面粉中痕量铁的测定,结果与AAS测定结果相符。  相似文献   

6.
双波长双指示剂催化动力学光度法测定痕量铁   总被引:1,自引:0,他引:1  
铁是人体健康所必须的微量元素,它对人体的生理功能有一定影响.如果体内可利用的铁不能满足血红蛋白正常合成的需要,致使红细胞增殖能力下降,就会造成缺铁性贫血.相反,体内铁含量过高,又易产生癌症~([1]).  相似文献   

7.
Using the oxidation reaction between hydrogen peroxide and dl-tyrosine as fluorescence indication, the evident tuning effect of nucleic acids on catalytic activity of mimetic enzyme iron (III) tetracarboxy phthalocyanine (FeC4Pc) in the presence of poly-lysine was observed and studied. The oxidation reaction between hydrogen peroxide and dl-tyrosine with FeC4Pc as catalyst gave an intensively fluorescent compound, which has an excitation wavelength of 325 nm and an emission wavelength of 418 nm. The fluorescence was quenched by a proper concentration of poly-lysine due to its association with FeC4Pc and consequently the descent of the catalytic activity of FeC4Pc, but recovered by addition of nucleic acids. Under optimal conditions, the recovered fluorescence is proportional to the concentration of nucleic acids. Based on the fact, a kinetic fluorescent method was developed for the determination of nucleic acids. The calibration graphs are linear over the range 10-2000 ng/mL both for fish sperm DNA (FS DNA) and calf thymus DNA (CT DNA). The corresponding detection limits are 1.04 ng/mL for FS DNA and 1.18 ng/mL for CT DNA, respectively. Four synthetic and three real nucleic acid samples were determined with satisfactory results.  相似文献   

8.
A highly sensitive spectrophotometric method is described for the determination of trace amounts of osmium(VIII), based on its catalytic effect on the oxidation of carminic acid by hydrogen peroxide. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of carminic acid at 540 nm after 3 min of mixing the reagents. The optimum reaction conditions were 1x10(-4) mol l(-1) carminic acid, 0.013 mol l(-1) hydrogen peroxide and pH 10 at 25 degrees C. By using the recommended procedure, the calibration graph was linear from 0.1 to 1.5 ng ml(-1) of osmium; the detection limit was 0.02 ng ml(-1); the RSD for five replicate determinations of 0.2-1.4 ng ml(-1) was in the range of 1.8-4.7%. The influence of several foreign ions on osmium determination were studied and the effect of interfering ions were removed by extracting osmium into isobuthyl methyl ketone and back extracting into sodium hydroxide solution.  相似文献   

9.
Zhou  Z. Y.  Dauphin  C.  Prognon  P.  Hamon  M. 《Chromatographia》1994,39(3-4):185-191
Summary A sensitive precolumn fluorescence derivatization method for low level detection of the, volatile (N-nitrosodimethylamine and N-nitrosopyrrolidine) and non-volatile N-nitrosamines (N-nitrosoproline and N-nitrosodiethanolamine) an high-performance liquid chromatography was developed. This method is based on the denitrosation of the compounds of interest by a mixture of hydrobromic acid and acetic acid to produce the corresponding secondary amines. These are, then, able to react with, a quinolizinocoumarin derivative (luminarin 9®) to form highly fluorescent labelled N-nitrosamine derivatives. The structural elucidation of the luminarin 9® derivatives of N-nitrosoproline and N-nitrosodimethylamine by way of example, were established by liquid chromatography-mass spectrometry (LC-MS) and by direct chemical ionization-mass spectrometry (CI-MS). The separation, derivatization and detection conditioins were optimized for all the studied compounds. The detection limits (signal to noise ratio=3) were between 0.4 and 1.0 pmol injected depending on the compound. The calibration graphs were linear for derivatized amounts in the range of 0.5–40 nmol for N-nitrosodimethylamine and N-nitrosopyrrolidine, 0.4–2- nmol for N-nitrosoproline and 1.0–40 nmol for N-nitrosodiethanolamine. The repeatability (RSD less than 3.5%, n=6) and reproducibility (RSD less than 4.8%, n-6) were satisfactory.  相似文献   

10.
D-Lactate in biological samples was converted into a strongly fluorescent substance in a one-vial reaction. It was first converted into the pyruvate hydrazone in the presence of D-lactate dehydrogenase, an NADH-reoxidation system using diaphorase, D,L-6,8-thioctamide and hydrazine. This hydrazone was then converted into 2-hydroxy-6,7-dimethoxy-3-methylquinoxaline by 1,2-diamino-4,5-dimethoxybenzene in 1 M hydrochloric acid, and the quinoxaline was extracted and measured fluorimetrically at 432 nm (excitation at 365 nm). The calibration curve for D-lactate was linear up to at least 100 nmol/ml of the assay mixture, with a determination limit of 2 nmol/ml. The quinoxaline was also analysed by high-performance liquid chromatography with fluorimetric detection. The calibration curve for D-lactate was linear from 500 fmol to 75 nmol in the reaction mixture. This method was 4000 times more sensitive than the fluorimetric method, and could determine D-lactate in blood plasma volumes of less than 1 microliter.  相似文献   

11.
Crude extract of kohlrabi (Brassica oleracea gongylodes) was prepared by a simple procedure and its enzymatic activity and total protein concentration were determined. It was found that this crude extract is a rich source of peroxidase (POx) and has high specific activity. Cross-linked polyvinylpyrrolidone was used as a stabilizer in the preparation of the crude extract. The POx activity of kohlrabi crude extract did not vary for at least 2 months when deoxygenated and stored at 4 degrees C. This extract was applied for the spectrofluorometric determination of hydrogen peroxide using homovanillic acid as a fluorogenic substrate. POx catalyzes the hydrogen peroxide oxidation of homovanillic acid to produce a dimer which shows strong fluorescence at 420 nm with excitation at 312 nm. In the optimum conditions, the calibration graph for hydrogen peroxide was linear up to 190 ng mL(-1), with a detection limit of 4.4 ng mL(-1). The relative standard deviation (RSD) was 1.48% for 50 ng mL(-1) hydrogen peroxide. The proposed method was successfully applied to the determination of hydrogen peroxide in honey. The concentration-time profile of H2O2 produced upon dilution of honey was studied and H2O2 contents of some different honeys from various areas of Iran were determined.  相似文献   

12.
This paper describes the application of organo nanoclay, an easily prepared and stable solid sorbent, to the preconcentration of trace amounts of palladium ions in aqueous solution. The organo nanoclay was prepared by adding tetradecyldimethylbenzylamonium chloride onto montmorillonite, which was then modified with 1-(2-pyridylazo)-2-naphthol. The modified nanoclay was used as a solid sorbent for separation and preconcentration of trace amounts of Pd(II) ions, and a simple, sensitive, and economical method was developed for determination of trace amounts of palladium by flame atomic absorption spectrometry. The sorption of Pd(II) ions was quantitative in the pH range of 1.5-5.0, whereas quantitative desorption occurred with 5.0 mL of a mixture containing 1.0 M thiourea and 1.0 M HCl. The RSD of the method was +/- 2.1% (n = 10; concn = 0.5 microg/mL), and the LOD (3sigma(bl); sigma = SD and bl = blank) was 0.1 ng/mL. The calibration curve was linear for concentrations of 0.5-8.0 microg/mL in the initial solution, and the preconcentration factor was 140. The maximum capacity of the sorbent was 2.4 mg Pd(II)/g modified organo nanoclay. The influences of the experimental parameters, including sample pH, eluant volume, eluant type, sample volume, and interfering ions, on the recoveries of the palladium ion were investigated. The proposed method was applied to the preconcentration and determination of palladium in different samples.  相似文献   

13.
Salinas F  Nevado JJ  Valiente P 《Talanta》1987,34(3):321-324
A kinetic method is described for determining trace amounts of manganese(II), based on its catalytic effect on the oxidation of salicylaldehyde guanylhydrazone by hydrogen peroxide. The reaction is followed spectrophotometrically by measuring the rate of change of absorbance at 505 nm. The calibration graph is linear in the range 8-80 mug/l. with a relative error of +/- 1%. The method has been applied to the determination of manganese in various samples.  相似文献   

14.
A new flow injection-kinetic method has been developed for the determination of trace amount of osmium(WI), based on its catalytic effect on the bromopyrogallol red and hydrogen peroxide reaction. The reaction is followed spectrophotometrically by measuring the decrease in absorbance at 559 nm. The calibration graph for osmium(VIII) is linear over the range from 0.0040 to 0.10 μg/ml and the detection limit and sampling frequency are 0.0030 μg/ml and 47 per hour, respectively. The proposed method was applied to the determination of trace amounts of osmium in refined ores and chlorination residues with satisfactory results.  相似文献   

15.
The peroxidase-like catalytic activity of metal complexes of thiacalix[4]arenetetrasulfonate (TCAS[4]) on a modified anion-exchanger (Me(n+)-TCAS[4]A-500; Me(n+) = H2, Fe3+, Fe2+, Mn3+, Co3+, Co2+, Cu2+, Zn2+, Ni2+) for the oxidation of p-hydroxyphenyl derivatives to produce fluorescent substances in the presence of hydrogen peroxide has been investigated. Among the Me(n+)-TCAS[4]A-500 tested, Fe(3+)-TCAS[4]A-500 exhibited the highest level of catalytic activity for the oxidation of p-acetoamidophenol in a carbonate buffer solution of pH 10. The catalytic activity of Fe(3+)-TCAS[4]A-500 was then used for the spectrofluorometric determination of hydrogen peroxide. The calibration curve for the Fe(3+)-TCAS[4]A-500 method was linear over a range spanning from 0.1 to 5.0 microg of hydrogen peroxide in a 1.0 ml sample solution.  相似文献   

16.
建立了测定肉制品中甘草抗氧化物含量的方法。样品经流动相提取,采用C.8色谱柱分离,以甲醇-0.2mol/L乙酸铵-冰乙酸(体积比70:29:1)为流动相,流速为1.0mL/min,波长为250nm,以保留时间进行定性,峰面积进行定量。甘草酸在1.0-80.0μg/mL范围内线性关系良好,回归方程为y=8.55×10^-5x-0.599(r=0.9997),检出限为1.0mg/kg,定量限为3.0mg/kg,加标回收率为95.7%-103.4%,测定结果的相对标准偏差为1.57%-3.53%(n=6)。该方法适用于检验机构日常检验中大批量肉制品中甘草抗氧化物含量的测定。  相似文献   

17.
以一种天然活性成分葛根素(Puerarin)为辣根过氧化物酶(HRP)底物建立了葛根素-辣根过氧化物酶-过氧化氢反应新体系. 在反应体系中 HRP 催化H2O2 氧化葛根素(弱荧光)形成二聚体产物(强荧光), 该产物在315 nm 的激发光下能发射波长为478 nm的强荧光, 并且反应体系荧光强度增加与HRP量在一定浓度范围内呈线性相关. 根据此关系和竞争型免疫定量原理, 以兔布氏杆菌抗体为分析对象建立了基于葛根素的酶联荧光免疫传感分析新方法. 对葛根素性质的研究结果证实, 葛根素在空气中稳定、对温度稳定, 对H2O2+HRP 敏感性优于传统底物如对羟基苯乙酸、Amplex Red和高香草酸. 优化了酶联荧光免疫传感分析方法的实验条件如HRP-BrAb 用量、温度等. 运用新体系测定了兔血清样品的布氏杆菌抗体, 该方法线性范围为1.3~120 ng/mL, 检测限为1.3 ng/mL (3σ), 相对标准偏差为3.8%.  相似文献   

18.
周宏兵  向日良夫 《色谱》2000,18(1):10-13
 合成了一种用于醇类分析的高灵敏度的荧光衍生化试 剂2-(4-羧基苯基)-4,5-萘并咪唑(CNI),将其在二氯甲烷中于80 ℃条件下与醇缩合成酯 ,并采用RP-HPLC法进行分离检测,色谱柱为Zorbax Bp C8柱(250 mm×4.6 mm i.d.) ,流动 相为V(乙腈)∶V(甲醇)=90∶10的溶液,荧光检测波长λex 345 nm, λem 485 nm。同时,测定了人血清中的胆固醇,其最低检出质量浓度为1.0 μg /L。  相似文献   

19.
A kinetic method is described for the determination of trace amounts of manganese(II), based on its catalytic effect on the oxidation of 2-hydroxybenzaldehyde thiosemicarbazone by hydrogen peroxide. The reaction is followed by measuring the rate of change of fluorescence (lambda(ex) 365 and lambda(em) 440 nm). The calibration is linear over the manganese range 2-9 ng ml with a precision of +/-1%. The proposed method suffers from few interferences.  相似文献   

20.
A novel method for the trace analysis of 17beta-estradiol (E2) in river water sample was developed, which involved stir bar sorptive extraction (SBSE) with in situ acylation (first derivatization) and thermal desorption (TD) with quartz wool assisted (QWA) in tube silylation (second derivatization), followed by gas chromatography-mass spectrometry (GC-MS), and is called the "dual derivatization method." The optimum conditions for SBSE with in situ acylation, such as the volume of acetic acid anhydride and the extraction time, were investigated. In addition, the optimum conditions for TD with QWA in tube silylation, such as the volume of N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) and the TD temperature and hold time, were investigated as well. The detection limit (S/N = 3) and the quantitation limit (S/N>10) of E2 in the river water sample were 0.5 and 2 pg ml(-1) (ppt), respectively, by the dual derivatization method. In addition, the detection limit was 0.1 pg ml(-1) by using dual derivatization method with multi-shot mode. The calibration curve for E2 was linear in the range of 0.002-10 ng ml(-1) with correlation coefficients >0.999. The average recoveries of E2 (n = 6) at the concentrations of 0.05 and 1.0 ng ml(-1) from the river water sample were 93.1 (RSD: 1.4%) and 98.4% (RSD: 0.8%), respectively, with correction using the added surrogate standard, 17beta-estradiol-(13)C(4). This simple, accurate, sensitive and selective analytical method may be applicable to the determination of trace amounts of E2 in water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号