首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
It is known that the main factors in a variation in the shape memory alloy properties under insonation are heating of the material and alternate stresses action. In the present work the experimental study of the mechanical behaviour and functional properties of shape memory alloy under the action of alternate stresses and varying temperature was carried out. The data obtained had demonstrated that an increase in temperature of the sample resulted in a decrease or increase in deformation stress depending on the structural state of the TiNi sample. It was shown that in the case of the alloy in the martensitic state, a decrease in stress was observed, and on the other hand, in the austenitic state an increase in stress took place. It was found that action of alternate stresses led to appearance of strain jumps on the strain–temperature curves during cooling and heating the sample through the temperature range of martensitic transformation under the constant stress. The value of the strain jumps depended on the amplitude of alternate stresses and the completeness of martensitic transformation. It was shown that the heat action of ultrasonic vibration to the mechanical behaviour of shape memory alloys was due to the non-monotonic dependence of yield stress on the temperature. The force action of ultrasonic vibration to the functional properties was caused by formation of additional oriented martensite.  相似文献   

2.
In recent years, LPS activated RAW264.7 cells are widely used as an in vitro inflammatory model for the screen of effective anti-inflammation drugs and the investigation of exact anti-inflammation mechanism of these drugs. But up to now, there are few data about the effect of LPS on the morphology, especially on the membrane ultrastructure and bio-mechanical properties of RAW264.7 macrophages. In this work, the topographical and biophysical changes of RAW264.7 macrophages upon LPS stimulation are detected by high resolution atomic force microscopy (AFM). The AFM results suggested that LPS activated RAW264.7 macrophages changed to be much bigger than control cells with some holes emerged on cell surface. The size of membrane protein clusters and the roughness of membrane significantly increased after LPS exposure. In addition, the AFM force measurement results demonstrated that LPS stimulation increased the adhesion force of RAW264.7 macrophages, and also increased the stiffness of RAW264.7 macrophages, which were attributed to the re-distribution of intracellular F-actin structures induced by LPS. These findings suggested that LPS stimulation could also induce the pathophysiological changes of RAW264.7 macrophages, which would benefit our understanding of the inflammatory processes in macrophages upon pathogen stimulation at nano-scale.  相似文献   

3.
原子力显微镜观察脂胞囊形貌结构及稳定性   总被引:5,自引:2,他引:5  
用原子力显微镜(AFM)观察了液晶态脂胞囊形貌结构和稳定性.实验结果显示,对于1,2-二油酸甘油-3-磷脂酰乙醇胺(DOPE)超分子聚集体,在扫描区域内,可观察到一些大小不同球形颗粒;对于1,2-二油酸甘油-3-磷脂酸乙醇胺(DOPE)和1,2-二油酸甘油-3-磷脂酰胆碱(DOPC)混合的超分子聚集体,则不仅观察到类似脂胞囊的球形颗粒,而且也观察到了双层膜结构,其厚度约为5~6 nm.  相似文献   

4.
We have observed three-dimensional sponge-like structures as well as strips of connecting pits on the surface of the LR 115 detector after etching, which can be confused with the small tracks formed after short etching time. We have employed an atomic force microscope (AFM) to study these “damages” as well as genuine alpha tracks for short etching time. It was found that while the track and damage openings could be similar in size and shape, the depths for the damages were consistently smaller. Therefore, the depth of the pits will serve as a clear criterion to differentiate between tracks and other damages. The ability to discriminate between genuine tracks from other damages is most important for etching for short time intervals.  相似文献   

5.
郑红星  刘剑  夏明许  李建国 《物理学报》2005,54(4):1719-1721
采用差示扫描量热和x射线衍射技术研究Ni-Fe-Ga磁致形状记忆合金的马氏体相变行为.结 果发现,在多晶Ni56556.5Fe19019.0Ga2452 4.5和Ni56356.3Fe17017.0 Ga26726.7合金中除马氏体相变外,还观察到一次完整的、正相变和逆相 变对应出现、单 纯由温度诱发的中间马氏体相变.该中间马氏体相变与马氏体相变均为热弹性相变. 关键词: Ni-Fe-Ga 中间马氏体相变 磁致形状记忆合金  相似文献   

6.
李盼盼  王敬民  蒋成保 《中国物理 B》2011,20(2):28104-028104
This paper studies the martensitic transformation in the Cu-doped NiMnGa alloys. The orthorhombic martensite transforms to L21 cubic austenite by Cu substituting for Ni in the Ni50-xCuxMn31Ga19 (x=2--10) alloys, the martensitic transformation temperature decreases significantly with the rate of 40 K per Cu atom addition. The variation of the Fermi sphere radius (kF) is applied to evaluate the change of the martensitic transformation temperature. The increase of kF leads to the increase of the martensitic transformation temperature.  相似文献   

7.
This study aimed to observe the multicellular spinning behavior of Proteus mirabilis by atomic force microscopy (AFM) and multifunctional microscopy in order to understand the mechanism underlying this spinning movement and its biological significance. Multifunctional microscopy with charge-coupled device (CCD) and real-time AFM showed changes in cell structure and shape of P. mirabilis during multicellular spinning movement. Specifically, the morphological characteristics of P. mirabilis, multicellular spinning dynamics, and unique movement were observed. Our findings indicate that the multicellular spinning behavior of P. mirabilis may be used to collect nutrients, perform colonization, and squeeze out competitors. The movement characteristics of P. mirabilis are vital to the organism's biological adaptability to the surrounding environment.  相似文献   

8.
True atomic resolution of conductors and insulators is now routinely obtained in vacuum by frequency modulation atomic force microscopy. So far, the imaging parameters (i.e., eigenfrequency, stiffness and oscillation amplitude of the cantilever, frequency shift) which result in optimal spatial resolution for a given cantilever and sample have been found empirically. Here, we calculate the optimal set of parameters from first principles as a function of the tip–sample system. The result shows that the either the acquisition rate or the signal-to-noise ratio could be increased by up to two orders of magnitude by using stiffer cantilevers and smaller amplitudes than are in use today.  相似文献   

9.
We demonstrated the high resolution imaging of the organic molecules using noncontact atomic force microscopy in ultrahigh vacuum. The sample was C60 molecules deposited on the Si(111)-7×7 reconstructed surface. When the thickness of the C60 film was submonolayer, we could image some isolated C60 molecules and the reconstructed Si surface simultaneously. However, the imaging was highly unstable not only because of the large structure but also due to the large difference between the interaction forces on the molecules and on the Si surface. On the other hand, when the thickness of the C60 molecules was almost monolayer, individual molecules could be stably imaged.  相似文献   

10.
Human serum albumin (HSA), a major plasma protein and plasma-derived therapeutic, interacts with a wide variety of drugs and native plasma metabolites. In this study the interactions of costunolide (CE) and dehydrocostuslactone (DE) with HSA were investigated by molecule modeling, atomic force microscopy (AFM), and different optical techniques. In the mechanism discussion, it was proved that fluorescence quenching of HSA by both of the drugs is a result of the formation of drug-HSA complexes. Binding parameters for the reactions were determined according to the Stern-Volmer equation and static quenching. The results of thermodynamic parameters ΔG0, ΔH0, and ΔS0 at different temperatures indicated that hydrogen bonding interactions play a major role in the drug-HSA associations process. The binding properties were further studied by quantitative analysis of CD, FTIR, and Raman spectra. Furthermore, AFM results showed that the dimension of HSA molecules became more swollen after binding with the drugs.  相似文献   

11.
We have studied frictional force between SiN tip and Si surface by using lateral force microscopy. The cantilever we have used has very low stiffness of 0.006 N/m, and the normal force acting on the surface was much lower than the attractive force such as van der Waals force. In this low normal force limit, it was found that the frictional force did not depend on the normal force. We suggest a calibration method to estimate the attractive force from the lateral force data in this limit. The estimated attractive force between Si sample and SiN tip with radius of 10 nm was 0.4 nN in flat region and 0.65 nN at the corner of a rectangular hole.  相似文献   

12.
We apply an external feedback control technique to vibrating microcantilevers in atomic force microscopy. Here we have no difficulty in getting information on periodic orbits required for application of the external feedback control unlike controlling chaos since stable orbits are used as reference ones. This approach enables us not only to control vibrations of the cantilevers but also to measure the sample surfaces (surface topographies) simultaneously. The efficiency and validity of our approach is demonstrated by numerical simulations and a theoretical analysis with the assistance of numerical computations.  相似文献   

13.
We introduce a dynamic force spectroscopy technique enabling the quantitative measurement of conservative and dissipative tip-sample forces in ambient conditions. In difference to the commonly detected force-vs-distance curves dynamic force microscopy allows to measure the full range of tip-sample forces without hysteresis effects caused by a jump-to-contact. The approach is based on the specific behavior of a self-driven cantilever (frequency-modulation technique). Experimental applications on different samples (Fischer-sample, silicon wafer) are presented.  相似文献   

14.
The exciting microstructures found in several eutectic alloys are a result of a cooperative growth, which is connected to the atomic transfer in the melt ahead the solid/liquid interface. In a eutectic system, the growth of solid phases depends on the simultaneous rejection of constituents to the liquid phase, which causes adjustments of the melt composition and hence, mass transport by diffusion normal to the growth direction. Generally, eutectic microstructures are examined by using optical (OM) and scanning electron microscopy (SEM). While OM may not provide the necessary resolution, the eutectic microstructure may present three-dimensional features, as a result of etching, which is not always possible to be observed by SEM. As an alternative, this paper describes the use of atomic force microscopy (AFM) in understanding micro-scale feature of a eutectic microstructure. For such a purpose, directionally solidified samples of a Ni–Al–V lamellar eutectic, a Ni–Al–Mo fibrous eutectic and a Ni–Al–Nb three-phase eutectic were examined. The results obtained provided a new picture of multi-phase microstructures and allows one to understand their new characteristics.  相似文献   

15.
Oxaliplatin is one of the most important anticancer drugs at present. However, the mechanism of action of oxaliplatin is still controversial. In this study, the interactions between oxaliplatin and a plasmid DNA have been studied so as to reveal the structural basis of its activity. The structural characteristic of pUC19 DNA (2 ng/μL) incubated with 100 μmol/L and 1000 μmol/L of oxaliplatin for the different time on a freshly cleaved highly ordered pyrolytic graphite (HOPG) surface was investigated by atomic force microscopy (AFM). High resolution AFM observation indicated that oxaliplatin can induce pUC19 DNA molecules change from the extended conformation to the entangled structures with many nodes, and finally to the compact particles. The present AFM results provide structural evidence about the interactions between oxaliplatin and circular duplex DNA containing multiple targets.  相似文献   

16.
The adsorption of DNA molecules on mica surface and the following desorption of DNA molecules at ethanol-mica interface were studied using atomic force microscopy. By changing DNA concentration, different morphologies on mica surface have been observed. A very uniform and orderly monolayer of DNA molecules was constructed on the mica surface with a DNA concentration of 30 ng/μL. When the samples were immersed into ethanol for about 15 min, various desorption degree of DNA from mica (0-99%) was achieved. It was found that with the increase of DNA concentration, the desorption degree of DNA from the mica at ethanol-mica interface decreased. And when the uniform and orderly DNA monolayers were formed on the mica surface, almost no DNA molecule desorbed from the mica surface in this process. The results indicated that the uniform and orderly DNA monolayer is one of the most stable DNA structures formed on the mica surface. In addition, we have studied the structure change of DNA molecules after desorbed from the mica surface with atomic force microscopy, and found that the desorption might be ascribed to the ethanol-induced DNA condensation.  相似文献   

17.
As a frame work of the study for the latent track size measurement using atomic force microscope, we have measured the minute etch pits and the extremely small amount of bulk etch of CR-39 at the beginning of chemical etching, and obtained its growth curves in nanometer dimensions. The pieces of CR-39 were exposed to 6 MeV/nC and Fe ions with normal incidence angle and were etched in 70°C 7 N NaOH solution for 0.5,1,2,3,5 min. The diameters of latent track were estimated to be 17 nm for Fe ions and 8 nm for C ions, respectively. These values are comparable to the experimental data on the average ‘track core diameters’ that have been obtained by various experimental techniques.  相似文献   

18.
When atomic force microscopy (AFM) is employed for in vivo study of immersed biological samples, the fluid medium presents additional complexities, not least of which is the hydrodynamic drag force due to viscous friction of the cantilever with the liquid. This force should be considered when interpreting experimental results and any calculated material properties. In this paper, a numerical model is presented to study the influence of the drag force on experimental data obtained from AFM measurements using computational fluid dynamics (CFD) simulation. The model provides quantification of the drag force in AFM measurements of soft specimens in fluids.The numerical predictions were compared with experimental data obtained using AFM with a V-shaped cantilever fitted with a pyramidal tip. Tip velocities ranging from 1.05 to 105 μm/s were employed in water, polyethylene glycol and glycerol with the platform approaching from a distance of 6000 nm. The model was also compared with an existing analytical model. Good agreement was observed between numerical results, experiments and analytical predictions. Accurate predictions were obtained without the need for extrapolation of experimental data. In addition, the model can be employed over the range of tip geometries and velocities typically utilized in AFM measurements.  相似文献   

19.
杨海艳  王振宇  李英姿  张维然  钱建强 《物理学报》2013,62(20):200703-200703
轻敲模式原子力显微镜高次谐波信号包含待测样品表面纳米力学特性等方面的信息, 但是传统原子力显微镜的高次谐波信号非常微弱. 里兹法证明在探针悬臂的特定位置打孔可以实现探针的内共振从而增强高次谐波信号强度. 本文通过有限元仿真计算获得探针第一共振频、第二共振频及其比值随着孔的尺寸和位置变化的规律. 在实验上通过聚焦离子束在探针悬臂上打孔使其第二共振频约为第一共振频的6倍, 提高了第6次谐波信号的信噪比, 并在实验室研制的高次谐波成像实验装置上获得了6次谐波图像. 关键词: 轻敲模式原子力显微镜 探针悬臂几何结构 高次谐波 聚焦离子束加工  相似文献   

20.
The nanoscaled tip in an AFM (atomic force microscope) has become an effective scratching tool for material removing in nanofabrication. In this article, the characteristics of using a diamond-coated pyramidal tip to scratch Ni-Fe thin film surfaces was experimentally investigated with the focus on the evaluation of the influence of the scratch or scan direction on the final shape of the scratched geometry as well as the applied scratch force. Results indicated that both the scratched profile and the scratch force were greatly affected by the scratch direction. It has been found that, to minimize the formation of protuberances along the groove sides and to have a better control of the scratched geometry, the tip face should be perpendicular to the scratching direction, which is also known as orthogonal cutting condition. To demonstrate the present findings, three groove patterns have been scratched with the tip face perpendicular to the scratching direction and very little amount of protuberances was observed. The threshold scratch force was also predicted based on the Hertz contact theory. Without considering the surface friction and adhesive forces between the tip and substrate, the threshold force predicted was twice smaller than the measurement value. Finally, recommendations for technical improvement and research focuses are provided.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号