首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
In order to improve the concentration sensitivity of capillary electrophoresis (CE), two sample preconcentration techniques, single drop microextraction (SDME) and large volume stacking using an electroosmotic flow pump (LVSEP), were coupled in-line in a commercial CE instrument. By simple programming of liquid handling sequences, a pentanol drop was prepared at the tip of a fused silica capillary over which a Teflon tube had been sleeved to serve as a hydrophobic support. After extraction of the analytes from an aqueous donor solution into the drop, the entire capillary column was filled with enriched pentanol extract. LVSEP, in which the sample matrix is automatically removed by the EOF, was then carried out using a methanolic run buffer. The overall enrichment factors for the analytes pentachlorophenol (PCP), 3-bromobenzoic acid (3-BBA), and 4-iodobenzoic acid (4-IBA), from a combination of 30 min SDME and LVSEP on a 27 cm capillary, were about 7000, even without agitation of the donor solution. The resulting limits of detection for PCP, 3-BBA, and 4-IBA were 0.7, 0.3 and 0.7 nM, respectively. Since no modification of the existing CE instrument is necessary and a bare capillary is used for LVSEP, this scheme can be adapted quite easily for many CE applications that require high concentration sensitivity.  相似文献   

2.
Single drop microextraction (SDME) is a convenient and powerful preconcentration method for CE before injection. By simple combination of sample‐handling sequences without modification of the CE apparatus, a drop of an aqueous acceptor phase covered with a thin organic layer was formed at the tip of a capillary; 10 min SDME of fluorescein and 6‐carboxyfluorescein from a donor phase of pH 1 to an acceptor phase of pH 9 provided 110‐fold enrichments without stirring the donor phase. To improve the concentration effect further, SDME was coupled with an on‐line (after injection) sample preconcentration method, sweeping, in which analytes in a long sample zone are accumulated at the boundary of a pseudostationary phase penetrating into the sample zone. It is thus necessary to inject a sample of much larger volume than that of a drop in typical SDME. A Teflon sleeve over the capillary inlet allowed a large volume drop to be held stably during extraction. By in‐line coupling 10 min SDME and sweeping of a 30 nL sample using a cationic surfactant dodecyltrimethylammonium, enrichment factors of the double preconcentration were increased up to 32 000.  相似文献   

3.
A novel approach based on ionic liquid‐single‐drop microextraction (IL‐SDME) online coupling with capillary electrophoresis (CE) was used to determine a toxic alkaloid – colchicine. The IL‐SDME procedure was optimized by extraction solvent, drop volume controlling, sample volume and pH, extraction time, and ionic strength. Under optimum conditions, enrichment factor was as much as 41‐fold with a relative standard deviation of 2.8% (n=3). Linear range of response was observed from 1 to 100 μg/mL, with detection limit of 0.25 μg/mL and correlation coefficient (R2) of 0.9994. The extraction of colchicine from spiked Lanzhou lily sample was performed and obtaining good result with an average recovery rate of 102.4 and 98.8% at 5 and 50 μg/mL, respectively. Comparing with the previous methods, IL‐SDME‐CE is really a convenient, economical, and environmentally benign way for determining colchicine.  相似文献   

4.
This study describes a method to determine nonsteroidal anti‐inflammatory drugs (NSAIDs) in urine samples based on the use of single‐drop microextraction (SDME) in a three‐phase design as a preconcentration technique coupled in‐line to capillary electrophoresis. Different parameters affecting the extraction efficiency of the SDME process were evaluated (e.g. type of extractant, volume of the microdroplet, and extraction time). The developed method was successfully applied to the analysis of human urine samples with LODs ranging between 1.0 and 2.5 μg/mL for all of the NSAIDs under study. This method shows RSD values ranging from 8.5 to 15.3% in interday analysis. The enrichment factors were calculated, resulting 27‐fold for ketoprofen, 14‐fold for diclofenac, 12‐fold for ibuprofen, and 44‐fold naproxen. Samples were analyzed applying the SDME–CE method and the obtained results presented satisfactory recovery values (82–115%). The overall method can be considered a promising approach for the analysis of NSAIDs in urine samples after minimal sample pretreatment.  相似文献   

5.
Capillary electrophoresis with large‐volume sample stacking using an electroosmotic flow pump was developed for the determination of chondroitin sulfate, dermatan sulfate, and hyaluronic acid. Central composite design was used to simultaneously optimize the parameters for capillary electrophoresis separation. The optimized capillary electrophoresis conditions were 200 mM sodium dihydrogen phosphate, 200 mM butylamine, and 0.5% w/v polyethylene glycol as a background electrolyte, pH 4 and ‐16 kV. Exploiting large‐volume sample stacking using an electroosmotic flow pump, the sensitivity of the proposed capillary electrophoresis system coupled with UV detection was significantly improved with limits of detection of 3, 5, 1 mg/L for chondroitin sulfate, dermatan sulfate, and hyaluronic acid, respectively. The developed method was applied to the determination of chondroitin sulfate and hyaluronic acid in cell culture media, cerebrospinal fluid, cosmetic products, and supplementary samples with highly acceptable accuracy and precision. Therefore, the proposed capillary electrophoresis approach was found to be simple, rapid, and reliable for the determination of chondroitin sulfate, dermatan sulfate, and hyaluronic acid in cell culture media, cerebrospinal fluid, cosmetic, and supplementary samples without sample pretreatment.  相似文献   

6.
Single drop microextraction (SDME) is a convenient and powerful preconcentration and sample cleanup method for capillary electrophoresis (CE). In SDME, analytes are typically extracted from a sample donor solution into an acceptor drop hanging at the inlet tip of a capillary. The enriched drop is then introduced to the capillary for CE analysis. Since the volume of the acceptor drop can be as small as a few nanoliters, the consumption of solvents can be minimized and the preconcentration effect is enhanced. In addition, by covering the acceptor phase with an organic layer or by using an organic acceptor phase, inorganic ions such as salts in the sample solution can be blocked from entering the acceptor phase, providing desalting effects. Here, we describe the basic principles and instrumentation for SDME and its coupling with CE. We also review recent developments and applications of SDME-CE.  相似文献   

7.
Zhu Z  Zhang L  Marimuthu A  Yang Z 《Electrophoresis》2002,23(17):2880-2887
A simple, quick, and sensitive capillary electrophoretic technique-large volume stacking using the electroosmotic flow (EOF) pump (LVSEP) - has been developed for determining ethylenediaminetetraacetic acid (EDTA) in drinking water for the first time. It is based on a precapillary complexation of EDTA with Fe(III) ions, followed by large-volume sample stacking and direct UV detection at 258 nm. The curve of peak response versus concentration was linear from 5.0 to 600.0 microg/L, and 0.7 to 30.0 mg/L. The regression coefficients were 0.9988 and 0.9990, respectively. The detection limit of the current technique for EDTA analysis was 0.2 microg/L with an additional 10-fold preconcentration procedure, based on the signal-to-noise ratio of 3. As opposed to the classical capillary zone electrophoresis (CE) method, the detection limit was improved about 1000-fold by using this LVSEP method. To the best of our knowledge, it represents the highest sensitivity for EDTA analysis via CE. Several drinking water samples were tested by this novel method with satisfactory results.  相似文献   

8.
黄颖  段建平  张建华  陈国南 《色谱》2007,25(3):326-331
建立了毛细管区带电泳(CZE)在线富集3种肌肽类活性肽(肌肽、鹅肌肽和高肌肽)的两种简便有效的方法。一种是大体积进样反向压力排除基体富集(LVSRP)技术,即通过流体动力学进样,在不改变电源极性的条件下,利用反向压力排除样品基体,电堆积富集后进行CZE分离;另一种是大体积进样电渗流排除基体富集(LVSEP)技术,即通过流体动力学进样,于运行缓冲液中加入溴化十六烷基三甲基铵(CTAB)动态修饰毛细管表面,通过电渗流排除样品基体,改变电源极性后进行CZE分离。与常规CZE相比,LVSRP技术和LVSEP技术使检测灵敏度提高了40~60倍。对影响两种富集过程的一些因素进行了研究,在最优富集条件下考察本方法的线性范围为0.080~5.0 μmol/L。对3种生物活性肽的检测限(S/N=3)分别为LVSRP 41~58 nmol/L,LVSEP 35~43 nmol/L。  相似文献   

9.
In this work, we overcame the deficiencies of large volume sample stacking (LVSS) in separating low‐mobility and neutral analytes through combining LVSS with sweeping in CE, and employed this new approach to enrich and separate neutral and anionic analytes simultaneously. This technique was carried out with pressure injection of large‐volume sample followed by EOF as a pump pushing the bulk of low‐conductivity sample matrix out of the outlet of the capillary while analytes were swept by micelles and separated via MEKC without the electrode polarity switching. Careful optimization of the enrichment and separation conditions allowed the enrichment factors (EFs) of peak height and peak area of the analytes to be in the range of 9–33 and 21–35 comparing with the conventional injection mode, respectively. The five analytes were baseline separated in 15 min and the detection limits ranged from 26.5 to 55.8 ng/mL (S/N = 3). The developed method was successfully applied to determine adenine, caffeine, theophylline, reduced L‐glutathione (GSH) and oxidized L‐glutathione (GSSG) in two different teas with recoveries that ranged from 84.4 to 105.2%.  相似文献   

10.
Headspace (HS) extraction is a sample pretreatment technique for volatile and semivolatile organic compounds in a complex matrix. Recently, in-tube microextraction (ITME) coupled with CE using an acceptor plug placed in the capillary inlet was developed as a simple but powerful HS extraction method. Here, we present single bubble (SB) ITME using a bubble hanging to the capillary inlet immersed in a sample donor solution as a HS of submicroliter volume (∼200 nL). The analytes evaporated to the bubble were extracted into the acceptor phase through the capillary opening, then electrophoresis of the enriched extract was carried out. Since the bubble volume was much smaller than a conventional HS volume (∼1 mL), it was filled with the evaporated analytes rapidly and the analytes could be enriched much faster compared to conventional HS-ITME. Owing to the high surface-to-volume ratio of the SB, 5 min SB-ITME yielded the enrichment factor values similar to those of 10 min HS-ITME. When 5 min SB-ITME at room temperature was applied to a tap water sample, the enrichment factors of 2,4,6-trichlorophenol (TCP), 2,3,6-TCP, and 2,6-dichlorophenol were 53, 41, and 60, respectively, and the LOQs obtained by monitoring the absorbance at 214 nm were 5.6–8.3 ppb, much lower than 200 ppb, the World Health Organization guideline for the maximum permissible concentration of 2,4,6-TCP in drinking water.  相似文献   

11.
Capillary zone electrophoresis methods, based on either aqueous and non-aqueous solutions as running buffers and UV spectrophotometric detection, have been developed and optimized for the separation of several halogenated phenolic and bisphenolic compounds, suspected or proved to exhibit hormonal disrupting effects. Both aqueous capillary electrophoresis (CE) and non-aqueous capillary electrophoresis (NACE) methods were suitable for the analysis of compounds under study. The separation of the analytes from other 25 potentially interfering phenolic derivatives was achieved with NACE method. Large-volume sample stacking using the electroosmotic flow pump (LVSEP) was assayed as on-column preconcentration technique for sensitivity enhancement. LVSEP-CE and LVSEP-NACE improved peak heights by 5-26 and 16-330 folds, respectively. To evaluate their applicability, the capillary electrophoresis methods developed were applied to the analysis of water samples, using solid-phase extraction as sample pre-treatment process.  相似文献   

12.
《Electrophoresis》2018,39(14):1771-1776
An ionic liquid‐based headspace in‐tube liquid‐phase microextraction (IL‐HS‐ITLPME) in‐line coupled with CE is proposed. The method is capable of quantifying trace amounts of phenols in environmental water samples. In the newly developed method, simply by placing a capillary injected with ionic liquids (IL) in the HS above the aqueous sample, volatile phenols were extracted into the IL acceptor phase in the capillary. After extraction, electrophoresis of the phenols in the capillary was carried out. Extraction parameters such as the extraction time, extraction temperature, ionic strength, volume of the sample solution, and IL types were systematically investigated. Under the optimized conditions, enrichment factors for four phenols were from 1510 to 1985. The proposed method provided a good linearity, low limits of detection (below 5.0 ng/mL), and good repeatability of the extractions (RSDs below 6.7%, n = 6). This method was then utilized to analyze two real environmental samples of Xiaoxi Lake and tap water, obtaining acceptable recoveries and precisions. Compared with the usual HS‐ITLPME for CE, IL‐HS‐ITLPME‐CE is a simple, low cost, fast, and environmentally friendly preconcentration technique.  相似文献   

13.
电渗泵中电渗流的控制   总被引:1,自引:0,他引:1  
电渗泵是利用载流的电渗驱动原理,结合电色谱(EC)、毛细管电泳(CE)、液相色谱柱技术制作的输液微泵,是新颖的流体和样品输送技术。电渗泵中电渗流(EOF)控制方法与EC和CE等文献中的电渗流控制方法是相同的。本文对EC和CE等文献中有关EOF控制方法作了总结,并对电渗泵的研究现状和应用作一些前瞻分析。  相似文献   

14.
Field amplified sample stacking (FASS) uses differential electrophoretic velocity of analyte ions in the high‐conductivity background electrolyte zone and low conductivity sample zone for increasing the analyte concentration. The stacking rate of analyte ions in FASS is limited by molecular diffusion and convective dispersion due to nonuniform electroosmotic flow (EOF). We present a theoretical scaling analysis of stacking dynamics in FASS and its validation with a large set of on‐chip sample stacking experiments and numerical simulations. Through scaling analysis, we have identified two stacking regimes that are relevant for on‐chip FASS, depending upon whether the broadening of the stacked peak is dominated by axial diffusion or convective dispersion. We show that these two regimes are characterized by distinct length and time scales, based on which we obtain simplified nondimensional relations for the temporal growth of peak concentration and width in FASS. We first verify the theoretical scaling behavior in diffusion‐ and convection‐dominated regimes using numerical simulations. Thereafter, we show that the experimental data of temporal growth of peak concentration and width at varying electric fields, conductivity gradients, and EOF exhibit the theoretically predicted scaling behavior. The scaling behavior described in this work provides insights into the effect of varying experimental parameters, such as electric field, conductivity gradient, electroosmotic mobility, and electrophoretic mobility of the analyte on the dynamics of on‐chip FASS.  相似文献   

15.
CE is gaining great popularity as a well‐established separation technique for many fields such as pharmaceutical research, clinical application, environmental monitoring, and food analysis, owing to its high resolving power, rapidity, and small amount of samples and reagents required. However, the sensitivity in CE analysis is still considered as being inferior to that in HPLC analysis. Diverse enrichment methods and techniques have been increasingly developed for overcoming this issue. In this review, we summarize the recent advances in enrichment techniques containing off‐line preconcentration (sample preparation) and on‐line concentration (sample stacking) to enhancing sensitivity in CE for trace analysis over the last 5 years. Some relatively new cleanup and preconcentration methods involving the use of dispersive liquid–liquid microextraction, supercritical fluid extraction, matrix solid‐phase dispersion, etc., and the continued use and improvement of conventional SPE, have been comprehensively reviewed and proved effective preconcentration alternatives for liquid, semisolid, and solid samples. As for CE on‐line stacking, we give an overview of field amplication, sweeping, pH regulation, and transient isotachophoresis, and the coupling of multiple modes. Moreover, some limitations and comparisons related to such methods/techniques are also discussed. Finally, the combined use of various enrichment techniques and some significant attempts are proposed to further promote analytical merits in CE.  相似文献   

16.
环境水样中百菌清残留的单滴微萃取-反相液相色谱测定   总被引:6,自引:1,他引:6  
应用单滴微萃取(SDME)-反相液相色谱(RPLC)检测了环境水样中的百菌清残留.优化了单滴微萃取条件:环己烷萃取剂6 μL、单滴体积2 μL、搅拌速率350 r/min、萃取时间40 min、水溶液温度35 ℃、无盐度.水样经单滴微萃取后,使用Hypersil C18柱反相液相色谱分离测定百菌清.反相液相色谱条件:100%甲醇流动相、流速1.0 mL/min、柱温25 ℃、224 nm检测.方法的线性范围、检出限、相对标准偏差和富集倍数分别为1.0 ~50 μg/L、0.02 μg/L、6.1%和427倍.采用该法对环境水样中的百菌清残留进行了测定,环境水样的加标回收率为98% ~106%.  相似文献   

17.
《Electrophoresis》2017,38(16):2075-2080
A combination of two online sample concentration techniques, large‐volume sample stacking with an electroosmotic flow (EOF) pump (LVSEP) and field‐amplified sample injection (FASI), was investigated in microchip electrophoresis (MCE) to achieve highly sensitive analysis. By applying reversed‐polarity voltages on a cross‐channel microchip, anionic analytes injected throughout a microchannel were first concentrated on the basis of LVSEP, followed by the electrokinetic stacking injection of the analytes from a sample reservoir by the FASI mechanism. As well as the voltage application, a pressure was also applied to the sample reservoir in LVSEP‐FASI. The applied pressure generated a counter‐flow against the EOF to reduce the migration velocity of the stacked analytes, especially around the cross section of the microchannel, which facilitated the FASI concentration. At the hydrodynamic pressure of 15 Pa, 4520‐fold sensitivity increase was obtained in the LVSEP‐FASI analysis of a standard dye, which was 33‐times higher than that obtained with a normal LVSEP. Furthermore, the use of the sharper channel was effective for enhancing the sensitivity, e.g., 29 100‐fold sensitivity increase was achieved with the 75‐μm wide channel. The developed method was applied to the chiral analysis of amino acids in MCE, resulting in the sensitivity enhancement factor of 2920 for the separated d ‐leucine.  相似文献   

18.
Wang CC  Chiou SS  Wu SM 《Electrophoresis》2005,26(13):2637-2642
This study describes approaches for stacking a large volume of sample solutions containing a mixture of mercaptopurine monohydrate, 6-methylmercaptopurine, thioguanine, thioguanosine, and thioxanthine in capillary electrophoresis (CE). After filling the run buffer (60 mM borate buffer, pH 8.5), a large sample volume was loaded by hydrodynamic injection (2.5 psi, 99.9 s), followed by the removal of the large plug of sample matrix from the capillary using polarity switching (-15 kV). Monitoring the current and reversing the polarity when 95% of current recovered, the separation of anionic analytes was performed in a run buffer < 20 kV. Around 44- to 90-fold improvement of sensitivity for five analytes was achieved by large-volume stacking with polarity switching when compared with CE without stacking. This method was feasible for determination of the analytes spiked in plasma. Removing most of electrolytes from plasma is a key step for performing large-volume sample stacking. Solid-phase extraction was used for pretreatment of biological samples. To our knowledge, this study is one of few applications showing the possibilities of this stacking procedure to analyze biological samples by large-volume sample stacking with polarity switching (LVSSPS) in CE.  相似文献   

19.
An automatic exposed and in‐syringe dynamic single‐drop microextraction method (SDME) for the determination of five polycyclic musks in natural waters was developed using gas chromatography with mass spectrometry. Online agitation was first introduced to the automatic SDME with a magnetic mixer fixed to the bottom of the sample tray of the autosampler. A high enrichment factor (110 ~182) for the target analytes could be achieved after several parameters that affected the microextraction were optimized. The recoveries were between 84.9 and 119.5%, while the limit of detection ranged from 3.4 to 11 ng/L with relative standard deviation < 11.1% for the polycyclic musks. This new SDME mode is fully automatic with great convenience, high enrichment and good reproducibility, and no human intervention. The proposed method was, therefore, successfully applied to determine the polycyclic musks in 31 surface sea waters that were collected from the Pearl River Estuary and the South China Sea. Most polycyclic musks could be detected with the total concentrations ranging from 58.9 to 528.5 ng/L. By using spatial interpolation method of ordinary kriging, the most contaminated area was found near the cities of Dongguan and Guangzhou with local discharge via the major rivers.  相似文献   

20.
The reaction between α,α-dialkylated amino acids and amino acid N-carboxyanhydrides is slow leading to low concentrations of products (peptides). The detection by capillary electrophoresis of the analytes contained in such samples is therefore a challenging issue. In this work, on-line sample pre-concentration methods based on field-amplified sample stacking have been implemented and compared. Because of the high ionic strength present in the sample matrix, samples were diluted with an organic solvent prior to analysis to decrease the sample conductivity. Different modes of sample injection (field amplified sample injection (FASI), hydrodynamic normal sample stacking (NSS) or large volume sample stacking (LVSS)) were compared. Pre-concentration factors of 20 for FASI, about 30–40 for NSS and 60 for LVSS were obtained for the analysis of (l,l) dipeptide of valine in a large excess of isovaline and 0.2 M of ionic strength. For LVSS application and resolution optimisation, a new non-covalent coating based on the partial modification of the capillary surface was used to tune the electroosmotic flow magnitude and to pump the sample matrix out of the capillary. This on-line sample pre-concentration step allowed confirming that oligopeptides including α,α-dialkylated amino acids are formed during the reaction between α,α-dialkylated amino acids and N-carboxyanhydride amino acids.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号