首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We demonstrate a concept‐proof work of using fluorescence (FL) “turn‐on” probes for the discriminatory detection of cysteine (Cys) over homocysteine (Hcy). The fluorogens are provided with aggregation‐induced emission (AIE) characteristic and functionalized with two aldehyde‐groups (DMTPS‐ALD and TPE‐ALD). All the detections were carried out in a biocompatible medium (10 mM HEPES buffer and DMSO, pH 7.4). In principle, the formation of thiazinane/thiazolidine through the chemical reaction of aldehydes on the probe molecules and the residue of Cys/Hcy determines the selective recognition of Cys and Hcy over other amino acids and glucose. The FL responses originate from the AIE property of thiazinane/thiazolidine resultants, which have low solubility and precipitate (aggregate) in the detection medium. The discrimination between Cys and Hcy comes from the difference in reaction kinetics of TPE‐ALD/DMTPS‐ALD with Cys and Hcy, thereby the FL responses show different time courses and intensity enhancement. It is worth noting that TPE‐ALD outshined the other two probes in performance with fast response, a high FL enhancement up to 16‐fold, high sensitivity, and good specificity and selectivity. Moreover, its FL response threshold at 250 μM is very close to the lower limit of the normal level of Cys in human plasma, which implies that TPE‐ALD could be applied as a potential indicator of Cys deficiency.  相似文献   

2.
An amphiphilic oligo p-phenylene derivative (DCHO) bearing electron-donating group (–NH(CH2)2OH) and electron-withdrawing group (–CHO) has been synthesised and characterised. The sensing characteristics of this probe (DCHO) for cysteine (Cys) and homocysteine (Hcy) are studied in a mixture solution of DMSO–HEPES by UV–vis and fluorescence spectra. 1H NMR, MALDI-TOF and UV–vis titration experiments proved that thiazolidine and thiazinane derivatives were formed. The highly Cys/Hcy-selective fluorescence hypsochromic shift (>110 nm) can be observed due to the switching of intramolecular charge transfer, leading to potential fabrication of ratiometric fluorescent detection of Cys/Hcy.  相似文献   

3.
Tae-Ki Kim 《Tetrahedron letters》2008,49(33):4879-4881
A new fluorescent sensor (1) based on a coumarin was synthesized for the selective detection of homocysteine (Hcy) and cysteine (Cys). The chemosensor has shown a selective response to Hcy or Cys over other various amino acids via a ring formation of thiazinane or thiazolidine. When Hcy or Cys was added, the fluorescent intensity of 1 was completely quenched through a photo-induced electron transfer with the sensitivity of sub-millimolar concentration.  相似文献   

4.
We designed and synthesized a series of BODIPY based probes with fast and distinct ratiometric responsiveness for discriminative detection of GSH from Cys and Hcy. The discriminative detection is based on the different products obtained by the SNAr between probes and thiol-containing amino acids. The amino group of the obtained thioether from the reaction with Cys or Hcy but not GSH would trigger an intramolecular nucleophilic substitution through five- or six-membered cyclic transition state, finally yielding an amino substituted derivative. To achieve highly discriminative detection and fast response, a series of structure modifications and improvements have been made by elongating the π-conjugation and introducing electron withdrawing groups, finally affording probe BOD-DBNPF with optimized responsiveness and selectivity. Importantly, BOD-DBNPF was successfully used for the selective detection of GSH from Cys with distinct fluorescent ratiometric responses in living HeLa cells.  相似文献   

5.
Thiol‐containing amino acids (aminothiols) such as cysteine (Cys) and homocysteine (Hcy) play a key role in various biological processes including maintaining the homeostasis of biological thiols. However, abnormal levels of aminothiols are associated with a variety of diseases. The native chemical ligation (NCL) reaction has attracted great attention in the fields of chemistry and biology. NCL of peptide segments involves cascade reactions between a peptide‐α‐thioester and an N‐terminal cysteine peptide. In this work, we employed the NCL reaction mechanism to formulate a Förster resonance energy transfer (FRET) strategy for the design of ratiometric fluorescent probes that were selective toward aminothiols. On the basis of this new strategy, the ratiometric fluorescent probe 1 for aminothiols was judiciously designed. The new probe is highly selective toward aminothiols over other thiols and exhibits a very large variation (up to 160‐fold) in its fluorescence ratio (I458/I603). The new fluorescent probe is capable of ratiometric detection of aminothiols in newborn calf and human serum samples and is also suitable for ratiometric fluorescent imaging of aminothiols in living cells.  相似文献   

6.
Biothiols such as cysteine (Cys), homocysteine (Hcy), and glutathione (GSH) play crucial roles in maintaining redox homeostasis in biological systems. This Minireview summarizes the most significant current challenges in the field of thiol‐reactive probes for biomedical research and diagnostics, emphasizing the needs and opportunities that have been under‐investigated by chemists in the selective probe and sensor field. Progress on multiple binding site probes to distinguish Cys, Hcy, and GSH is highlighted as a creative new direction in the field that can enable simultaneous, accurate ratiometric monitoring. New probe design strategies and researcher priorities can better help address current challenges, including the monitoring of disease states such as autism and chronic diseases involving oxidative stress that are characterized by divergent levels of GSH, Cys, and Hcy.  相似文献   

7.
The specific detection of cysteine (Cys) over homocysteine (Hcy), glutathione (GSH) and other amino acids is of great significance for studying its biological functions as well as for the diagnosis of related diseases. Chloroacetyl group was often used as a reaction site for cysteine fluorescent probes for its sensitivity and selectivity. However, high background fluorescence and low stability are common problems encountered by such probes. Here, four chloroacetyl group based fluorescent probes (C1, C2, C3, and H4) was synthesized for a comparative study. We found that the inefficient quenching ability of chloroacetyl group turned into an advantage when connected with a ratiometric fluorophore. With the modification of chloroacetyl group, probe H4 displayed excellent ratiometric property and great selectivity for Cys, the stability was also improved. Additionally, the probe was successfully applied for quantitative detection of Cys in fetal bovine serum and real-time imaging in living HeLa cells with low toxicity.  相似文献   

8.
Two fluorescence probes for the detection of cysteine (Cys), glutathione (GSH) and other biothiols, such as homocysteine (Hcy) and cysteinyl-glycine (Cys-Gly), were developed. These molecular probes are coumarin-based derivatives containing a chalcone-like moiety that reacts with biothiols through a Michael addition reaction, leading to strong fluorescence enhancements. The reactivity of the tested biothiols toward both probes (ChC1 and ChC2) follows the order Cys > GSH > Hcy > Cys-Gly, ChC1 being less reactive than ChC2. Possible interference with other amino acids was assessed. ChC1 and ChC2 display a highly selective fluorescence enhancement with thiols, allowing these probes to be used for fluorimetric thiol determination in SH-SY5Y cells.  相似文献   

9.
Background autofluorescence from biological systems generally reduces the sensitivity of a fluorescent probe for imaging biological targets. Addressing this challenge requires the development of fluorescent probes that produce emission in the near‐infrared region. Herein, we report the design and synthesis of a fluorescent probe that generates an NIR emission with a large Stokes shift upon the selective response to Cys over Hcy and GSH. The probe is designed to consist of two Cys‐sensing sites, an acrylate ester and an aldehyde installed ortho to each other. The reaction of the probe with Cys triggers an excited state intramolecular proton transfer process upon photo‐excitation, thereby producing an NIR emission with a large Stokes shift. Accordingly, this probe hold great promise for the selective detection of Cys in biological systems. We further demonstrate the capacity of this probe for Cys imaging in living cells.  相似文献   

10.
《Tetrahedron》2019,75(36):130477
Two fluorescein derivatives containing 2,4-dinitrobenzenesulfonyl group have been developed as fluorescent probes to detect the biothiols (Cys, Hcy and GSH) in aqueous solution. Probes 1 and 2 can distinguish these biothiols in the presence of other amino acids. While probe 1 can recognize the biothiols in PBS/DMSO (v:v = 95:5, pH = 7.40) solution, notably probe 2 could be used in PBS buffer solution (pH = 7.40). The detection limit of Cys for probe 2 reached at 0.021 μM in aqueous solution, which was lower than the intracellular concentration of Cys. In the recognition process, a reaction between the probes and the biothiols occurred, in which the S–O bond was cleaved to remove 2, 4-dinitrobenzenesulfonyl group. The data of 1H NMR, MS and DFT/TD-DFT calculation further confirmed the detection mechanism. Moreover, two probes were successfully applied to the HeLa cell imaging.  相似文献   

11.
A turn-on fluorescent probe, based on a water-soluble terphenyl derivative, for the detection of cysteine and homocysteine is reported. The aldehyde groups in the probe play crucial roles in providing reaction with thiol groups in the amino acids, leading to a formation of thiazolidine (from cysteine) or thiazinane ring (from homocysteine). As a result, the new formation of such rings alters the electronic property of the conjugated system in the probe and results in emission enhancement. The probe in aqueous solution exhibits a remarkable increase in its quantum yield upon exposure to cysteine (up to 20-fold) and to homocysteine (up to 700-fold), while slight quenching is observed in the presence of glutathione. Moreover, an investigation on time-resolved fluorescence spectra of the probe in the presence of cysteine and homocysteine reveals potential discriminatory detection of cysteine and homocysteine. Bioimaging of the thiols in live HeLa cells was successfully applied.  相似文献   

12.
Chen H  Zhao Q  Wu Y  Li F  Yang H  Yi T  Huang C 《Inorganic chemistry》2007,46(26):11075-11081
A new homocysteine-selective sensor based on the iridium(III) complex Ir(pba)2(acac) (Hpba = 4-(2-pyridyl)benzaldehyde; acac = acetylacetone) was synthesized, and its' photophysical properties were studied. Upon the addition of homocysteine (Hcy) to a semi-aqueous solution of Ir(pba)2(acac), a color change from orange to yellow and a luminescent variation from deep red to green were evident to the naked eye. The blue-shift of the absorption spectrum and enhancement of the phosphorescence emission upon the addition of Hcy can be attributed to the formation of a thiazinane group by selective reaction of the aldehyde group of Ir(pba)2(acac) with Hcy, which was confirmed by 1H NMR studies. Importantly, Ir(pba)2(acac) shows uniquely luminescent recognition of Hcy over other amino acids (including cysteine) and thiol-related peptides (reduced glutathione), in agreement with the higher luminescent quantum yield of the adduct of Ir(pba)2(acac) with Hcy (0.038) compared with that of the adduct with Cys (~0.002). Both surface charge analysis and the electrochemical measurement indicated that a photoinduced electron-transfer process for Ir(pba)2(acac)-Cys might be responsible for the high specificity of Ir(pba)2(acac) toward Hcy over Cys.  相似文献   

13.
Due to the biological importance of amino acids, the development of optical probes for these molecules has been an active research area in recent years. This tutorial review focuses on recent contributions since the year 2000 concerning the fluorescent or colorimetric sensors for amino acids, and is organized according to their structural classification and reaction types. For reaction based chemosensors, the works are classified according to the mechanisms between sensors and amino acids, including imine formation, Michael addition, thiazinane or thiazolidine formation, cleavage of a sulfonate ester, cleavage of disulfide, metal complexes-displace coordination and others.  相似文献   

14.
《化学:亚洲杂志》2017,12(16):2098-2103
The development of a fluorescent probe to distinguish between cysteine (Cys) and homocysteine (Hcy) is always a challenge owing to their structural similarity, and the simultaneous detection of Cys and Hcy by utilizing different emission channels is especially difficult. In this work, we designed and synthesized a new fluorescent probe to differentiate between Cys and Hcy on the basis of a coumarin derivative with a chlorine atom and an α,β‐unsaturated aldehyde. Cys and Hcy induced different cascade reactions with the probe, which led to different products with distinct photophysical properties. The nonfluorescent probe responded to Cys and emitted strong blue fluorescence, whereas it reacted with Hcy and generated yellow fluorescence without interference from glutathione. In addition, the probe was successfully applied to distinguish between Cys and Hcy in living cells.  相似文献   

15.
A new strategy for fast fluorescent detection of cysteine (Cys), based on a response‐assisted electrostatic attraction, is demonstrated. By utilizing this strategy, we designed and synthesized three fluorescent probes for the specific detection of Cys under actual physiological conditions. The probe m‐ CP , a coumarin fluorophore conjugated with a substituted methyl pyridinium group through an unsaturated ketone unit, showed highly selective and sensitive detection for cysteine (Cys) over homocysteine (Hcy) and glutathione (GSH). The kinetic analysis indicated that the sensing process was highly accelerated (a response time less than 1 min) by the response‐assisted electrostatic attraction. More importantly, control experiments with isomeric probes first demonstrated that the spatial charge configuration of the probe played an important role in Cys‐preferred selectivity and kinetic rate acceleration. Furthermore, the practical utility of the probe m‐ CP in the fluorescent labeling of Cys residues within proteins was demonstrated. Finally, these probes were employed in living cell imaging with HeLa cells, in which it displayed satisfactory cell permeability and enabled us to distinguish active thiols in the cytoplasm, nucleus, and mitochondria.  相似文献   

16.
A simple colorimetric method for the determination of cysteine and homocysteine has been developed. The reaction of the azo dyes containing an aldehyde group with cysteine or homocysteine afforded very stable derivatives thiazolidines or thiazinanes under neutral pH conditions. The method is selective and sensitive for cysteine and homocysteine detection without the interference of other amino acids. Importantly, the recognition of Cys and Hcy could be observed by naked eyes.  相似文献   

17.
Homocysteine (Hcy) is a sulfur-containing α-amino acid that differs by one methylene (CH2) subunit from homologous cysteine (Cys). Elevated levels of Hcy are diagnostic markers of cardiovascular disease and other medical conditions. We present a new CuII-salicylidene glycinato complex 1 for the selective fluorometric detection of Hcy in water. In the presence of this analyte, the non-fluorescent copper-complex demetallates and disassembles into its building blocks. This process liberates a 3-chloro-5-sulfosalicylaldehyde signaling unit and is accompanied by a 51-fold turn-on fluorescence at 485 nm (λex=350 nm). Out of twenty proteinogenic amino acids, only histidine (12-fold turn-on fluorescence) and Cys (8-fold turn-on fluorescence) trigger some disassembly of probe 1 . In comparison with important pioneering work on the detection of biothiols, this study strikingly demonstrates that structural modifications of chelate core structures steer substrate selectivity of metal-based probes. Importantly, probe 1 has proven suitable for the detection of Hcy in artificial urine.  相似文献   

18.
An HPLC‐fluorescence (FL) method for determination of sulfur‐containing amino acids such as homocysteine (Hcy), methionine (Met) and cysteine (Cys) in human plasma was developed. The sulfur‐containing amino acids were labeled with 4‐(N,N‐dimethylaminosulfonyl)‐7‐fluoro‐2,1,3‐benzoxadiazole (DBD‐F). Calibration curves in the range of 1–100 µm (Hcy and Met) and 5–500 µm (Cys) indicated good linearities (r ≥ 0.998). The limits of detection at a signal‐to‐noise ratio of 3 were 0.13 (Hcy), 0.02 (Met) and 0.11 µm (Cys), respectively. Acceptable results for accuracy and precision of intra‐ and inter‐day measurements were obtained. The results of Hcy and Cys obtained by the proposed method indicated good correlations with the conventional method (r > 0.911, n = 20). Furthermore, the method was applied to determination of the sulfur‐containing amino acids in maternal plasma (n = 200) after delivery. The concentrations of Hcy, Met and Cys as a median (inter quartile range, Q1 and Q3) were 5.37 (3.32–7.79) μm , 25.20 (20.10–31.06) μm and 147.25 (102.81–189.31) μm , respectively. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

19.
A semi‐micro column HPLC‐fluorescence method for routine determination of thiol derivatives such as homocysteine (Hcy), cysteine (Cys) and cysteamine (CA) is described. The thiol derivatives labeled with ammonium‐7‐fluorobenzo‐2‐oxa‐1,3‐diazole‐4‐sulfonate (SBD‐F) were isocratically separated within 12 min on a semi‐micro ODS column (Daisopak‐SP‐120‐5‐ODS‐BP) with a mixture of 25 mm acetate buffer (pH 2.00) and CH3CN as a mobile phase. The purity and similarity of SBD‐thiols by a multi‐wavelength fluorescence detector were more than 92.3 and 96.7%. The detection limits of Hcy, Cys and CA at a signal‐to‐noise ratio of 3 were 0.16, 0.47 and 0.03 µm , respectively. Furthermore validation parameters such as accuracy, precision and robustness of the proposed method showed satisfactory results. Almost 850 plasma sample injections (range 572–1076, n = 3) for a column could be performed without differences in retention time and peak heights of labels. As an application of the proposed method, the determination of thiol derivatives in normal human plasma (n = 103) was demonstrated. The correlation coefficients between Hcy vs Cys and Hcy vs CA were 0.38 and −0.35, respectively. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
Differentiation of biologically important thiols, such as cysteine (Cys), homocysteine (Hcy), and glutathione (GSH) is still a challenging task. Herein, we present a novel fluorescent chemodosimeter capable of selectively detecting Cys over other biothiols including Hcy and GSH and other amino acids by a facile thiol‐Michael addition/transcyclization rearrangement cascade click process. The unique transcyclization step is critical for the selectivity as a result of the kinetically favorable formation of a six‐membered ring with the Cys Michael adduct. Moreover, the probe adopts a distinctive dual quenching mechanism—photoinduced electron transfer (PET) and photoinduced intramolecular charge transfer (ICT) to deliver a drastic turn‐on fluorescence response only at the Cys‐selective transcylization step. The judicious selection of strong electron‐withdrawing naphthalimide fluorophore with maleimide group enhances the electrophilicity and thus reactivity for the cascade process leading to fast detection and ultrasensitivity with a detection limit of 2.0 nm (S/N=3). The probe has demonstrated its practical utility potential in Cys imaging in live cells.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号