首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The voltammetric behavior of Strontium Ranelate (SR) was studied using Cyclic (CV), differential pulse (DPV) and square wave (SWV) voltammetry. CV showed two well‐defined, irreversible, diffusion‐controlled anodic peaks using Britton‐Robinson buffer, pH 2.0 at Pencil graphite (PGE), Carbon paste (CPE) and glassy carbon (GCE) electrodes. The peak current‐concentration relationship was rectilinear over the range 1.0–10.0, 1.0–11.25 and 2.5–24.0 µg/mL at PGE, CPE and GCE respectively, with a minimum detectability of 0.17, 0.24 and 0.39 µg/mL for peak 1 and 0.19, 0.27 and 0.51 µg/mL for peak 2. Recoveries showed the high accuracy of the method; 99.8 %, 99.5 % and 99.7 % at PGE, CPE and GCE respectively for peak 1 and 100.1 %, 99.9 % and 99.7 % at PGE, CPE and GCE respectively for peak 2. Hence DPV and SWV were conducted for the quantitative determination of SR in its pure and pharmaceutical dosage form. the method was validated and the results were in good agreement with those obtained from the reported method.  相似文献   

2.
A new, simple and low cost voltammetric method for the determination of cefpirome in pharmaceutical preparations has been developed using multiwalled carbon nanotube modified glassy carbon electrode (MWCNT), which showed stable response with enhanced selectivity and sensitivity over the bare glassy carbon electrode. A multiwalled carbon nanotube (MWCNT) modified glassy carbon electrode (GCE) is used for the simultaneous determination of cefpirome by differential pulse voltammetry and square wave voltammetry. Results indicated that cathodic peak of cefpirome is greatly improved at MWCNT modified GC electrode as compared with the bare GC electrode showing excellent electrocatalytic activity towards cefpirome reduction. Linear calibration curves are obtained over the concentration range 100-600 μg mL(-1) in Britton Robinson buffer at pH 4.51 with limit of detection (LOD) and limit of quantification (LOQ) are 0.647 μg mL(-1) and 2.159 μg mL(-1) using SWV and 5.540 μg mL(-1) and 18.489 μg mL(-1) using DPV, respectively. The described method is rapid and can be successfully applied for the determination of cefpirome in bulk form and pharmaceutical formulations.  相似文献   

3.
In this research, copper oxide nanoparticles modified carbon paste electrode was developed for the voltammetric determination of lidocaine. The square wave voltammogram of lidocaine solution showed a well-defined peak between +0.5 and +1.5 V. Instrumental and chemical parameters influencing voltammetric response were optimized by both one at a time and Box–Behnken model of response surface methodology. The results revealed that there was no significant difference between two methods of optimization. The linear range was 1–2500 μmol L~(-1)(Ip= 0.11 C_(LH)+ 17.38, R~2= 0.999). The LOD and LOQ based on three and ten times of the signal to noise(S/N) were 0.39 and 1.3 μmol L~(-1)(n = 10),respectively. The precision of the method was assessed for 10 replicate square wave voltammetry(SWV)determinations each of 0.05, 0.5 and 1 μmol L~(-1) of lidocaine showing relative standard deviations 4.1%,3.7% and 2.1%, respectively. The reliability of the proposed method was established by application of the method for the determination of lidocaine in two pharmaceutical preparations, namely injection and gel.  相似文献   

4.
《Analytical letters》2012,45(11):1783-1802
Abstract

Griseofulvin is an antifungal antibiotic used to treat various pathogenic mycotic diseases. The voltammetric behavior of griseofulvin at a hanging mercury drop electrode in Britton‐Robinson buffers of pH 2–11.5 was studied and discussed. A fully validated sensitive square‐wave adsorptive cathodic stripping voltammetric procedure was described for direct determination of bulk griseofulvin substance. The procedure was based on the reduction of the >C?O double bond of griseofulvin molecule following its preconcentration onto a hanging mercury drop electrode in a Britton‐Robinson buffer of pH 10. Limits of detection (LOD) and quantitation (LOQ) of 5.8×10?10 M and 1.93×10?9 M bulk griseofulvin were achieved, respectively. The proposed stripping voltammetric procedure was successfully applied to assay griseofulvin in tablets and in spiked human serum and urine samples. LOD of 8.65×10?10 M and 6.6×10?9 M and LOQ of 2.88×10?9 M and 2.2×10?8 M griseofulvin in spiked human serum and urine samples, respectively, were achieved.  相似文献   

5.
In this work, a green technique for preparing TbFeO3/CuO was reported by employing Crataegus and Lantana Camara leaves as fuel and alkalizing agents, respectively. The new sensor based on the perovskite-type nanocomposite was employed as a sensitive and selective platform to detect Pb(II), Zn(II) and Cd(II) simultaneously. TbFeO3/CuO/Carbon paste electrode (CPE) exhibited a large specific surface area and great electrical conductivity, which enhanced electron transport in the electrochemical process considerably. Moreover, square wave anodic stripping voltammetry (SWASV) was used for the investigation of some factors influencing the sensor sensitivity like pH, modifier concentration, as well as accumulation time and potential. Therefore, the low detection limit (LOD) and a wide linear range were obtained at optimum conditions. In this study, a linear range between 0.9 and 110 µg/L for three ions and LOD of 0.48, 0.29 and 0.12 for zinc, cadmium and lead were achieved, respectively. Moreover, TbFeO3/CuO/CPE was employed to detect zinc, cadmium and lead ions simultaneously in the real samples so that the results have shown consistency with a standard inductively coupled plasma (ICP).  相似文献   

6.
An adsorptive stripping square wave voltammetric (AdSqW) method was developed for the determination of 3-nitrotyrosine (3-NT), a biomarker of in vivo oxidative damage in Alzheimer, ALS, Parkinson’s, cardiovascular diseases and cancer, in some biological fluids. Voltammetric measurements were performed in 0.30 M (pH 9.0) phosphate solution as supporting electrolyte, a reduction peak was observed at–0.487 V (vs. Ag/AgCl–3 M KCl) with a hanging mercury drop electrode by square wave voltammetry. Cyclic voltammetric measurements showed that the current was adsorption-controlled. LOD and LOQ values were as 0.25 and 1.5 nM, respectively, for the AdSqW method. 3-NT was determined in plasma and cerebrospinal fluid using AdSqW method, which allowed to work at low concentrations. Recovery value was measured as 96.3 ± 2.3%.  相似文献   

7.
In the present work TiO2 nanotubes (TNT) have been synthesized by alkaline hydrothermal transformation. Then they have been doped with Gd element. Characterizations of doped and undoped TNT have been done with TEM and SEM. The chemical composition was analyzed by EDX, Raman and FTIR spectroscopy. The crystal structure was characterized by XRD. Carbon paste electrode has been fabricated and mixed with Gd doped and undoped TNT to form a nanocomposite working electrode. Comparison of bare carbon paste electrode and Gd doped and undoped TNT carbon paste electrode for 1.0 ×10−3 M K4 [Fe(CN)6] voltammetric analysis; it was observed that Gd doped TNT modified electrode has advantage of high sensitivity. Gd doped TNT modified electrode has been used as working electrode for itopride assay in a pharmaceutical formulation. Cyclic voltammetry analysis showed high correlation coefficient of 0.9973 for itopride (0.04–0.2 mg/mL) with a limit of detection (LOD) and limit of quantitation values (LOQ) of 2.9 and 23.0 μg.mL−1 respectively.  相似文献   

8.
研究了沙丁胺醇(SAL)在表面活性剂十二烷基苯磺酸钠(SDBS)现场自组装膜与离子液体1-苄基-3-甲基咪唑六氟磷酸盐([BnMIM]PF6)复合修饰碳糊电极(SDBS-[BnMIM]PF6/CPE)上的电催化氧化行为和电化学动力学性质。实验结果表明,SDBS-[BnMIM]PF6/CPE对SAL的电化学氧化具有良好的催化作用。用循环伏安法(CV)和计时电流法(CA)测得SAL在SDBS-[BnMIM]PF6/CPE上的电极反应过程动力学参数。用方波伏安法(SWV)测得SAL氧化峰电流(Ipa)与其浓度在9.0×10-5~1.0×10-3mol.L-1范围内呈良好的线性关系,检出限(S/N=3)为1.08×10-6mol.L-1。运用该方法对市售吸入用沙丁胺醇溶液中SAL的含量进行了测定,结果满意。  相似文献   

9.
Ersin Demir 《Electroanalysis》2019,31(8):1545-1553
In the present study, desmedipham, used as an herbicide to control broad leaf weed in commonly sugar beet crops, was analyzed at the first time by cyclic voltammetry (CV) and square wave stripping voltammetry (SWSV) with the modified carbon paste electrode based on hematite nanoparticles (α‐Fe2O3?CPE). The modified α‐Fe2O3?CPE prepared by hematite (α‐Fe2O3 nanoparticles), which is very sensitive to carbon paste electrode (CPE) and glassy carbon electrode (GCE). Morphology of electrode surface detailed by scanning electron microscopy (SEM) and energy dispersive X‐ray analysis (EDX). The oxidation of desmedipham created irreversible well‐done two peaks at nearly +1.1 and +1.3 V. In order to obtain the best calibration graph, various important parameters such as pH, accumulation time, puls amplitude and frequency etc. were investigated. Under the optimum conditions, electrochemical behavior of desmedipham presented two linear working ranges at 0.15–1.20 mg/L and 1.20–4.50 mg/L. The limits of detection (LOD) for the desmedipham were calculated as 41.00 and 50.00 μg/L for the peak I and II, respectively. Furthermore, desmedipham was analyzed at high recovery in the presence of rizolex, fluometuron, teflubenzuron and some heavy metal ions. Consequently, the developed SWSV was successfully applied to evaluate desmedipham in spiked commercial strawberry juices at recoveries of 96.00–104.00 % with satisfactory relative standard deviations.  相似文献   

10.
Nine widely used veterinary sulfonamide drugs were baseline separated (R s ≥1.5) in just over 4 min using a 3 × 100 mm, 1.8 μm RX-Sil column, with 9.2 % methanol in carbon dioxide, at 110 bar and 30 °C, with direct UV detection at 260 nm using a 3 mm, 2 μL tapered flow cell. Pressure drop was only 172 bar. Optimization was difficult due to the similarity in structures. Small changes in modifier concentration, temperature and pressure, each tended to improve the resolution of some peak pairs but degraded the resolution of others. There were four critical pairs, each responding differently to changes in conditions. Optimization was performed by plotting resolution between pairs as a function of modifier concentration first, temperature second, and outlet pressure third. Retention time was then minimized by changing flow rate. The estimated limit of quantitation (LOQ, S/N >10), for direct injections, was ≈200–400 ng/g of each, inadequate for regulatory requirements. Solid phase extraction (SPE) attempted to pre-concentrate samples spiked with sulfamethazine by ≈20:1. From water, the limit of detection (LOD) was ≈2.7 ng/mL with LOQ ≈9 ng/mL using UV at 260 nm. The LOD for milk was 6.2 ng/mL, and LOQ was 20.1 ng/mL. A better pre-concentration step or a more sensitive detector such as MS–MS is required. Even with these inadequacies, SFC was shown to be a feasible, faster, “greener” alternative to HPLC for the separation of these drugs.  相似文献   

11.
2,4-dichlorophenoxyacetic acid (2,4-D) is an auxinic herbicide used to control broadleaf weeds. It is also a threatening factor for not only aquatic life but also human health due to its genotoxicity and endocrine disruptive property. Herein, the interaction between 2,4-D and double stranded DNA was investigated by using single-use pencil graphite electrodes (PGE) in combination with electrochemical techniques. The detection mechanism was based on the monitoring of the changes at the guanine oxidation signal obtained before/after surface-confined interaction of 2,4-D and DNA at the surface of PGE. The electrochemical characterization of the interaction was studied by using microscopic and electrochemical techniques. The response obtained by interaction in the presence of another herbicide, glyphosate, which is widely used with 2,4-D for weed control, was compared to the one occurred in the presence of 2,4-D. Electrochemical monitoring of the interaction between the herbicide whose active molecule was 2,4-D and DNA was also investigated. The detection (LOD) and quantification limits (LOQ) for 2,4-D and the herbicide could be obtained in the linear concentration ranges of 30–70 µg/mL and 10–30 µg/mL, respectively and LOD and LOQ values were found to be 2.85 and 9.50 µg/mL for both 2,4-D and the herbicide. The sensitivity of the biosensor was calculated as 0.087 µA.mL / µg.cm2 .This is the first study in literature by means of not only voltammetric detection of 2,4-D and DNA interaction but also the herbicide-DNA interaction at the surface of PGE based on the changes at the guanine signal.  相似文献   

12.
In this study, a simple and sensitive square wave voltammetric procedure has been developed for the determination of acemetacin (ACM) at graphite flake paste electrode (GFPE) and glassy carbon electrode (GCE). Under optimized conditions, the dependence of ACM peak current on its concentration showed wide linear range: 0.03–1.0 μmol L−1 and 0.7–15.0 μmol L−1 at GFPE and GCE, respectively. The developed method was successfully applied for the determination of ACM in pharmaceuticals and spiked urine with satisfying recoveries. The electrochemical oxidation of ACM is an irreversible process controlled by mixed nature of the mass transfer process.  相似文献   

13.
Berger  Terry A.  Berger  Blair K. 《Chromatographia》2013,76(23):1631-1639

Nine widely used veterinary sulfonamide drugs were baseline separated (R s ≥1.5) in just over 4 min using a 3 × 100 mm, 1.8 μm RX-Sil column, with 9.2 % methanol in carbon dioxide, at 110 bar and 30 °C, with direct UV detection at 260 nm using a 3 mm, 2 μL tapered flow cell. Pressure drop was only 172 bar. Optimization was difficult due to the similarity in structures. Small changes in modifier concentration, temperature and pressure, each tended to improve the resolution of some peak pairs but degraded the resolution of others. There were four critical pairs, each responding differently to changes in conditions. Optimization was performed by plotting resolution between pairs as a function of modifier concentration first, temperature second, and outlet pressure third. Retention time was then minimized by changing flow rate. The estimated limit of quantitation (LOQ, S/N >10), for direct injections, was ≈200–400 ng/g of each, inadequate for regulatory requirements. Solid phase extraction (SPE) attempted to pre-concentrate samples spiked with sulfamethazine by ≈20:1. From water, the limit of detection (LOD) was ≈2.7 ng/mL with LOQ ≈9 ng/mL using UV at 260 nm. The LOD for milk was 6.2 ng/mL, and LOQ was 20.1 ng/mL. A better pre-concentration step or a more sensitive detector such as MS–MS is required. Even with these inadequacies, SFC was shown to be a feasible, faster, “greener” alternative to HPLC for the separation of these drugs.

  相似文献   

14.
A new voltammetric sensor based on electropolymerization of glycine at glassy carbon electrode (GCE) was developed and applied to determine of pyrazinamide (PZA) by square-wave voltammetry (SWV). The initial cyclic voltammetric studies showed an electrocatalytic activity of poly(Gly)/GCE on redox system of pyrazinamide in 0.1 mol L?1 phosphate buffer solution pH 7.5, with E Pc and E Pa in ?0.85 and ?0.8 V (versus E Ag/AgCl), respectively. Studies at different scan rates suggest that the redox system of pyrazinamide at poly(Gly)/GCE is a process controlled by diffusion in the interval from 10 to 100 mV s?1. Square-wave voltammetry-optimized conditions showed a linear response of PZA concentrations in the range from 0.47 to 6.15 μmol L?1 (R?=?0.998) with a limit of detection (LOD) of 0.035 μmol L?1 and a limit of quantification (LOQ) of 0.12 μmol L?1. The developed SWV-poly(Gly)/GCE method provided a good intra-day (RSD?=?3.75 %) and inter-day repeatability (RSD?=?4.96 %) at 4.06 μmol L?1 PZA (n?=?10). No interference of matrix of real samples was observed in the voltammetric response of PZA, and the method was considered to be highly selective for the compound. In the accuracy test, the recovery was found in the range of 98.2 and 104.0 % for human urine samples and pharmaceutical formulation (tablets). The PZA quantification results in pharmaceutical tablets obtained by the proposed SWV-poly(Gly)/GCE method were comparable to those found by official analytical protocols.  相似文献   

15.
The usefulness of fullerene modified glassy carbon electrode in mediating the reduction of cefitizoxime in solubilized system has been demonstrated. Due to the unique structure and extraordinary properties, fullerene shows higher catalytic efficiency towards cefitizoxime reduction. The kinetic parameters, electron transfer coefficient (α) and rate constant (K0) across the modified electrode are 0.37 and 0.1081/s respectively. The proposed square‐wave voltammetric method is linear over the concentration range 1.2–10.3 µg/mL. The limit of detection (LOD) is found 0.27 ng/mL. High sensitivity and selectivity together with low detection limit of the electrode response make it suitable for the determination of cefitizoxime.  相似文献   

16.
Glassy carbon electrodes (GCE) and carbon paste electrodes (CPE) were modified with imidazole functionalized polyaniline with the aim to develop a sensor for lead (II) in both acidic and basic aqueous solution. The electrodes were characterized by cyclic voltammetry and differential pulse adsorptive stripping voltammetry. The limit of detections obtained with glassy carbon electrode and carbon paste electrode are 20?ng?mL-1 and 2?ng?mL-1 of lead ion, respectively. An interference study was carried out with Cd(II), As(III), Hg(II) and Co(II) ions. Cd(II) ions interfere significantly (peak overlap) and As(III) has a depressing effect on the lead signal. The influence of pH was investigated indicating that bare and modified GCE and CPE show optimum response at pH?4.0 ± 0.05.
Figure
Imidazole functionalized polyaniline modified glassy carbon and carbon paste electrodes were used for lead ion detection by using CV and DPASV techniques. The lower detection limit observed with GCE and CPE are 20?ng mL-1 and 2?ng mL-1.  相似文献   

17.
《Analytical letters》2012,45(8):1392-1404
The electrochemical behavior of cyromazine (N-cyclopropyl-1,3,5-triazine-2,4,6 triamine) insecticide has been studied at newly prepared multi-wall carbon nanotubes paste electrodes using square wave stripping voltammetry. The cyromazine was accumulated at 0.0 mV [vs. Ag/AgCl (3 M NaCl)] and a well-defined anodic peak obtained at +1110 mV in 0.1 M H2SO4. The cyclic voltammetric measurements showed an irreversible nature of oxidation wave in the range of scan rates comprised between 500 and 4000 mV s?1. The calibration curve obtained from square wave stripping voltammetry was linear in the range 0.41 to 83.30 µg/mL with a detection limit of 0.12 µg/mL. The method was applied to the direct determination of cyromazine in natural water samples. Recoveries calculated for river and tap water samples spiked with 10.0 µg/mL level were 101.5 ± 1.9% and 100.6 ± 2.3% at 95% confidence level, respectively. The method was extended to the determination of cyromazine in agrochemical formulation Trigard® with a recovery of 100.49% and accuracy was in agreement with that obtained by HPLC comparison method. Influences of some interfering ions and pesticides were also investigated.  相似文献   

18.
N-乙酰-L-半胱氨酸在咖啡酸修饰碳糊电极上的电催化氧化   总被引:1,自引:1,他引:0  
研究了N-乙酰-L-半胱氨酸(N-acetyl-L-cysteine,NAC)在咖啡酸(CFA)修饰碳糊电极(CFA/CPE)上的电催化行为。结果表明,NAC在裸碳糊电极(CPE)上的直接电化学氧化过程十分迟缓,而CFA/CPE对NAC的电化学氧化具有良好的催化作用。用循环伏安法(CV)、计时电流法(CA)测定了NAC在CFA/CPE上的电极过程动力学参数。电荷传递系数α=0.79,电催化氧化反应速率常数k=(4.40±0.10)×10^3(mol.L^-1)^-1.s^-1。用微分脉冲伏安法(DPV)测得催化氧化峰电流与NAC浓度在1.0×10^-6~7.5×10^-4mol.L^-1范围内呈良好的线性关系,线性回归方程为Ipa(μA)=4.075c(mmol.L^-1)+2.671,r=0.9988,检出限为1.7×10^-7mol.L^-1。用该方法对市售药品富露施中的NAC含量进行测定,结果令人满意。  相似文献   

19.
A chromatographic system is developed for the separation and determination of levodopa, biogenic amines, and their metabolites from the catecholamines group: dopamine (DA), epinephrine (E), normetanephrine (NMN), metanephrine (MN), 3,4-dihydroxyphenylacetic acid (DOMA), 3-metoxy-4-hydroxyphenyl-glycol (MHPG), and homovanillic acid (HVA); and indoloamines group: serotonin (5HT) and 5-hydroxyindole-3-acetic acid (5HIAA) in urine. The limit of detection (LOD) and limit of quantitation (LOQ) are determined for all compounds with signal-to-noise ratio (S/N) of 3 and 10, respectively. LOD 10 (ng/mL) and LOQ 30 (ng/mL) are determined for L-DOPA, DOMA, E, NMN, DA, MN, and MHPG, as well as LOD 8 (ng/mL) and LOQ 24 (ng/mL) for HVA, 5HT, and 5HIAA. A fluorescence detector is used. Gradient elution with acetate buffer (pH=4.66) with methanol is applied. In urine samples from patients treated with levodopa, the following concentrations (microg/mL) of analytes are determined: L-DOPA 3.73-46.80, DOMA 1.43-28.43, E 0.83-13.57, NMN 2.58-8.81, DA 24.07-62.11, MN 0.89-66.20, MHPG 6.72-63.64, 5HT 22.96-95.27, 5HIAA 1.45-14.77, and HVA 0.21-15.07.  相似文献   

20.

The two adsorptive stripping voltammetric approaches for detection and quantitative determination of diethyl (2E)-2-{(2E)-[1-(4-methylphenyl)imidazolidin-2-ylidene]hydrazinylidene}butanedioate (DIB)—a novel molecule of medical importance—using two sensitive sensors based on modified glassy carbon electrodes as reusable sensors, were developed for the first time. The proposed electrochemical methods are based on adsorptive/reductive behaviour of DIB at two modified carbonic electrodes: a bismuth film-modified glassy carbon electrode (BiF/GCE) and a lead film-modified glassy carbon electrode (PbF/GCE). The electron gain mechanism for the electrochemical reduction of DIB on both developed sensors was proposed for the first time. To achieve the highest sensitivity in adsorptive stripping determinations, various experimental variables (e.g. the composition and pH of the supporting electrolytes, deposition conditions of bismuth and lead films, concentrations of plating solutions, accumulation times and potentials of DIB, etc.) were extensively examined. The comparison of validation parameters obtained during the determination of DIB at two sensors was presented. The excellent linear correlation was found between the monitored adsorptive stripping voltammetric peak current and the DIB concentration in the range of 15–600 μg L−1 at an accumulation time of 30 s (with LOD = 4.2 μg L−1 and LOQ = 14.0 μg L−1) using the BiF/GCE as a sensor. Furthermore, the excellent linear relationship was confirmed between the monitored adsorptive stripping voltammetric peak current and the DIB concentration in the range of 9–900 μg L−1 at an accumulation time of 10 s (with better LOD = 1.5 μg L−1 and LOQ = 5.0 μg L−1), employing the PbF/GCE as a sensor. The two optimized adsorptive stripping voltammetric approaches—as facile, sensitive, reliable and inexpensive—were successfully used as first methods for the quantitative analysis of a novel anticancer agent (DIB) in its pure pharmaceutically acceptable form. However, the practical applicability of square-wave adsorptive stripping voltammetric determination of the electroactive DIB molecule at a PbF/GCE, as the modified electrode of higher sensitivity, was presented after its successful solid phase extraction from a real serum sample.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号