首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 812 毫秒
1.
于泓  丁永胜  牟世芬 《色谱》2002,20(5):398-402
 用阴离子交换 积分脉冲安培检测法测定了氨基酸注射液中 1 7种氨基酸和葡萄糖。研究了氨基酸和葡萄糖在阴离子交换中的保留行为。采用了优化的水、NaOH和NaAc三元梯度淋洗条件。在优化的梯度淋洗条件和积分脉冲安培检测条件下 ,氨基酸和葡萄糖的检出限为 0 3pmol~ 1 0 3pmol,线性范围约为 2个数量级。样品加标回收率为 88 3 %~ 1 0 4 6 %。方法简单、灵敏、准确。  相似文献   

2.
Some factors influencing the separation and detection of amino acids by high-performance anion-exchange chromatography with integrated pulsed amperometric detection were investigated. These factors include eluent concentration, column temperature, and detection waveform. The selectivity changes in weakly retained amino acids are slight with changing sodium hydroxide eluent concentration. When sodium acetate eluent concentration is changed, the selectivity variations between strongly retained amino acids containing two carboxyl groups and containing only one carboxyl group are obviously different. Significant but slight selectivity changes in weakly retained amino acids can be achieved through changing the column temperature. Sodium hydroxide and sodium acetate eluent concentration affect the detection of amino acids. Detection sensitivity of amino acids can be improved by increasing the concentration of sodium hydroxide and sodium acetate in a certain concentration range. The detections of amino acids at two different detection waveforms were compared. The hydroxyl amino acids can be selectively detected by choosing a modified detection waveform. The optimized gradient elution condition and column temperature for analyzing 19 amino acids were obtained. The time for the gradient elution program was 60 min. The column temperature was 35 degrees C. Under the optimized conditions, detection limits for 19 amino acids were 0.15-4.52 pmol. The calibration graphs of peak area for all the analytes were linear for about three orders of magnitude. The RSDs (n=5) of peak area were 0.6-5.6%. The determination of trace amino acid impurities in valine product is shown as an application example.  相似文献   

3.
A polymer monolith bearing weak cation-exchange functionality was prepared for the purpose of demonstrating pH-selective extraction and elution in in-line solid-phase extraction-capillary electrophoresis (SPE-CE) utilising a model set of cationic analytes, namely imidazole, lutidine and 3-phenylpropanamine. Optimization of the electrolyte conditions for efficient elution of the adsorbed analytes using a moving pH boundary required that the capillary and monolith be filled with 44 mM sodium acetate at high pH (pH 6) and a low pH electrolyte of 3 mM sodium acetate pH 3 was placed in the electrolyte vials. This combination allowed the adsorbed analytes to be simultaneously eluted and focused into narrow bands, with peak widths of the eluted analytes having a baseline width of 1.2 s immediately after the monolith. Using these optimum elution conditions, the versatility of the SPE-CE approach was demonstrated by removing unwanted adsorbed components after extraction with a wash at a different pH and also by selecting a pH at which only some of the model weak bases were ionised. The analytical performance of the approach was evaluated and the relative standard deviation for peak heights, peak area and migration times were in the ranges of 1.4-5.3, 1.2-3.3 and 0.4-1.2% respectively. Analytes exhibited linear calibrations with r(2) values ranging from 0.996 to 0.999 over two orders of magnitude. Analyte pre-concentration provided excellent sensitivity, and limits of detection for the analyte used in this study were in the range 8.0-30 ng ml(-1), which was an enhancement of 63 when compared to normal hydrodynamic injection occupying 1.3% of the capillary of these bases in water.  相似文献   

4.
A method based on pre-capillary derivatization with luminol (3-aminophthalhydrazide) for carbohydrate analysis using capillary electrophoresis with on-line chemiluminescence (CL) detection was developed. The derivatives of seven monosaccharides were separated and detected by using 200 mM borate buffer containing 100 mM hydrogen peroxide at pH 10.0 as separation electrolyte and 25 mM hexacyanoferrate in 3 M sodium hydroxide solution as post-capillary chemiluminescence reagent with separation efficiencies ranging from 160,000 to 231,000 plates per metre. The minimum amount of carbohydrate derivatized was 2 pmol (corresponding to the concentration of 2 microM). The method also provided a linear response for glucose in the concentration range of 0.1-250 microM with a mass detection limit of 420 amol or a concentration detection limit of 0.1 microM. Preliminary work using the CE-CL format to determine glucose in a rat brain microdialysis sample is presented as a typical case.  相似文献   

5.
Dionex high-performance ion chromatographic methods were evaluated for separation and quantitation of plant sugars and starch digestion products in the ruminal digesta of cattle. Mono- and disaccharides were eluted from a Dionex CarboPac PA1 column with sodium hydroxide used isocratically or as a pH gradient. Maltooligosaccharides which had a degree of polymerization (DP) less than 30 glucose residues were eluted in 60 min by a sodium hydroxide eluent containing a sodium acetate gradient. Carbohydrates were detected amperometrically. Responses were linear (r2 greater than 0.99) for glucose, disaccharides and maltooligosaccharides (DP less than 8). Precipitation and solid-phase extraction methods were evaluated for clean-up of samples of feedstuffs, ruminal contents, and bacterial culture fluids. Perchloric acid precipitation hydrolyzed sucrose but did not affect recoveries of cellobiose, isomaltose or maltose. Ethanol in concentrations of 79 and 86% precipitated maltooligosaccharides having chain lengths larger than 14 and 9 glucose residues, respectively. Maltooligosaccharide recoveries from solid-phase extraction columns varied with maltooligosaccharide size and column packing. Recoveries were greater than 94% for short chains (DP less than 6) eluted from phenyl-substituted columns and variable for all oligosaccharides eluted from C18 columns. Applications of these methods are presented and include: (1) detection of sugars in ruminant feed, (2) monitoring changes in ruminal sugars after feeding and (3) monitoring changes in extracellular sugars and oligosaccharides in the culture fluids of the ruminal bacterium, Bacteroides ruminicola.  相似文献   

6.
Fast protein liquid chromatography (FPLC) in combination with ion-exchange chromatography on a Mono Q column was used to purify glucose oxidase from Penicillium amagasakiense to homogeneity. Purification was performed with a mixed pH and salt gradient, with 20 mM phosphate buffer (pH 8.5) as starting buffer (A) and 50 mM acetate buffer (pH 3.6) with 0.1 M NaCl as elution buffer (B). Elution conditions were optimized to permit the simultaneous purification and separation of the glucose oxidase isoforms. Three peaks, each consisting of 1-2 isoforms and exhibiting a homogeneous titration curve profile, were resolved with a very flat linear gradient of 5.0-5.1% B in 40 ml. Three more peaks, each consisting of several isoforms, were eluted at 10%, 30% and 100% B. Optimization of the elution conditions and separation of the glucose oxidase isoforms was only possible because of the rapidity of each purification step and the high resolution provided by FPLC and Mono Q.  相似文献   

7.
Homogenization of hexadecane in water at pH 9 gives the same surface charge density in the presence of 0.2 mM thiocyanate or acetate anions as in the presence of chloride, indicating that these dipolar anions are not preferentially adsorbed at the oil/water interface. The decrease in the zeta potential of the emulsion droplets as the sodium salts of iodate, thiocyanate, or acetate are added from 0.1 to 10 mM is the same as that when sodium chloride is added, leading to the same conclusion. Increasing the sodium hydroxide concentration from pH 9 to 11.5 has a different effect on the zeta potential, consistent with the specific adsorption of hydroxide ion at the oil/water interface.  相似文献   

8.
A rapid and sensitive high performance liquid chromatographic method is described for the simultaneous determination of benzylpenicillin, ampicillin, phenoxymethylpenicillin, cloxacillin, dicloxacillin and nafcillin in small samples of human serum. The chromatographic system involves the use of a Spherisorb ODS reversed phase column and a gradient elution with 1 mM ammonium acetate buffer/acetonitrile (from 90:10 to 75:25 in 15 min). Detection and quantification are monitored by UV absorption at 208 nm. The compounds are extracted with dichloromethane, using tetrabutylammonium hydrogen sulfate neutralized with sodium hydroxide and buffered with borate as an ion pairing reagent; beta-hydroxyethyltheophylline is added as an internal standard. Our results show that the method is accurate and reproducible, allowing quantification of serum levels of assayed penicillins (0.5-50 micrograms/mL) without interference from other drugs commonly used in therapy. Recoveries were generally greater than 79.4%.  相似文献   

9.
A method for determination of anions and cations in boric acid is proposed by matrix volatilization. The boric acid matrix was eliminated as trimethyl borate ester in a vapour phase matrix elimination (VPME) system using a mixture of glycerol-methanol. In this VPME system, in situ reagent purification, sample decomposition and digest evaporation were achieved in a single step. Trace anions were separated on anion-exchange column (IonPac AS17) by an isocratic elution with 15 mM sodium hydroxide and the cations on a cation-exchange column (IonPac CS12) by 20 mM hydrochloric acid as eluents. Method detection limits (3sigma) for most ions ranged from 0.3 to 8 ng/g (ppb). Recovery experiments combined with comparison of data obtained by other methods were employed to verify the accuracy of the proposed method. Application of the method to determine trace levels of anions like acetate, oxalate, sulfate, phosphate and cations such as lithium, sodium, potassium, magnesium and calcium in two highly pure grades of boric acid using ion chromatography is demonstrated.  相似文献   

10.
We have established a simple method for assaying the quantity of soluble bromine in the discharge tubes of an extra-high-pressure mercury discharge lamp. Each discharge tube is destroyed in 5 ml of 10 mM sodium hydroxide, and the recovered sodium hydroxide solution is analyzed by suppressed-ion chromatography using gradient elution. We have clarified that this method can assay less than 1 microg of soluble bromine in a discharge tube.  相似文献   

11.
Two water-insoluble glucans, U-3-N ([alpha]D +1.0 degree, 0.5 M sodium hydroxide) and U-3-AP1 ([alpha]D +2.5 degrees, 1 M sodium hydroxide) were isolated from hot-water extract of the fruiting bodies of Y? ?r (Chinese name) (Auricularia sp.). U-3-N and U-3-AP1 were investigated by a combination of chemical and spectroscopic methods. The results indicated that U-3-N (molecular weight, 6.1 x 10(5)) was similar to beta-(1----6)-branched (1----3)-beta-D-glucan (N-5P: molecular weight, 5.6 x 10(5)) isolated from the alkaline extract of the fruiting bodies, and U-3-AP1 (molecular weight, 6.3 x 10(4)) was beta-(1----6)-branched (1----3)-beta-D-glucan containing beta-(1----6)-linked D-glucopyranosyl residues. U-3-N showed potent anti-tumor activity against the solid form of sarcoma 180, although U-3-AP1 had little effect on the tumor.  相似文献   

12.
A sensitive, specific, and reliable liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for detection and identification of zeranol in chicken or rabbit liver. A homogenized liver sample was hydrolyzed with beta-glucuronidase/arylsulfatase, and the hydrolysate was extracted with ethyl ether. The supernatant was evaporated to dryness, and the residue was dissolved in chloroform and re-extracted with sodium hydroxide. After acidification, the extract was cleaned up on a C18 solid-phase extraction cartridge and analyzed by electrospray LC-MS/MS in the negative ion mode. The multiple reaction monitoring transition from both m/z 321 to 277 and m/z 321 to 303 was monitored for confirmation, and the product ion of 277 was used for quantitation. Separation was performed on a Waters XTettra C18 column (50 x 2.1 mm, 3.5 microm) combined with a safeguard column (Symmetry C18, 20 x 3.9 mm, 5 microm), using a gradient elution with acetonitrile and 20 mM ammonium acetate. Calibration curves were prepared and good linearity was achieved over the concentration ranges tested. For all liver samples fortified at 3 different levels of 1, 5, and 50 microg/kg, the overall recoveries and relative standard deviations were in the range of 61-90 and 8-13%, respectively. The limit of quantitation based on the assay validation was 1 microg/kg. The method had been used on a routine basis for detection and identification of zeranol in liver samples.  相似文献   

13.
Regulatory agencies from all over the world have set up stringent guidelines with regard to drug degradation products due to their toxic effects or carcinogenicity. Lansoprazole, a proton‐pump inhibitor, was subjected to forced degradation studies as per ICH guidelines Q1A (R2). The drug was found to degrade under acidic, basic, neutral hydrolysis and oxidative stress conditions, whereas it was found to be stable under thermal and photolytic conditions. The chromatographic separation of the drug and its degradation products were achieved on a Hiber Purospher, C18 (250 × 4.6 mm, 5 μ) column using 10 mM ammonium acetate and acetonitrile as a mobile phase in a gradient elution mode at a flow rate of 1.0 ml/min. The eight degradation products (DP1–8) were identified and characterized by UPLC/ESI/HRMS with in‐source CID experiments combined with accurate mass measurements. DP‐1, DP‐2 and DP‐3 were formed in acidic, DP‐4 in basic, DP‐5 in neutral and DP‐1, DP‐6, DP‐7 and DP‐8 were in oxidation stress condition Among eight degradation products, five were hitherto unknown degradation products. In addition, one of the major degradation products, DP‐2, was isolated by using semi preparative HPLC and other two, DP‐6 and DP‐7 were synthesized. The cytotoxic effect of these degradation products (DP‐2, DP‐6 and DP‐7) were tested on normal human cells such as HEK 293 (embryonic kidney cells) and RWPE‐1(normal prostate epithelial cells) by MTT assay. From the results of cytotoxicity, it was found that lansoprazole as well as its degradation products (DP‐2, DP‐6 and DP‐7) were nontoxic up to 50‐μM concentrations, and the latter showed slightly higher cytotoxicity when compared with that of lansoprazole. DNA binding studies using spectroscopic techniques indicate that DP‐2, DP‐6 and DP‐7 molecules interact with ctDNA and may bind to its surface. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

14.
Tyrosinemia type 1, which is caused by a deficiency in fumarylacetoacetate hydrolase, is successfully treatable with nitisone (NTBC), an inhibitor of 4-hydroxyphenyl pyruvate dioxygenase. The recommended average dose of NTBC is 1 mg/kg per day. A rapid liquid chromatography (LC) coupled with negative electrospray ionization tandem mass spectrometry method was developed and validated for the quantification of NTBC in heparinized human plasma. The plasma samples were prepared by precipitation in acetonitrile. NTBC and the internal standard (IS) were chromatographed on a BEH C18 column. Gradient elution was done with a mixture of 10 mM ammonium acetate and methanol. The analyte was analyzed by LC-tandem mass spectrometry with only 2 min run time. Selected reaction monitoring modes for detection of NTBC and the IS were achieved by using m/z 328 > 281 and 234 > 190, respectively. The LC retention times for NTBC and IS were 0.99 and 0.93 min, respectively. The method was linear in the concentration range of 0.75-150 μM with r ≥ 0.998. Thus, this method is suitable for follow-up of patients treated with NTBC, because the current therapeutical concentrations range from 20 to 120 μM.  相似文献   

15.
The inability to separate fluoride, phosphate and sulfate by electrostatic ion chromatography (EIC) was overcome by using an ODS silica column coated with mixed zwitterionic-cationic surfactants as the stationary phase. The best results were obtained using the zwitterionic surfactant, 3-(N,N-dimethylmyristylammonium)-propanesulfonate (C19H41NO3S), and the cationic surfactant, myristyltrimethylammonium, CH3(CH2)13N+(CH3)3, in a 10:1 molar ratio in the column coating solution. With a dilute solution of sodium tetraborate as the eluent the model analyte anions were completely separated in the following elution order: F, HPO42-, SO42-, Cl-, NO2-, Br-, NO3-. The very early elution of phosphate and sulfate is most unusual and is unique to this system. Detection limits better than 1.1 x 10(-4) mM and linear calibration plots up to 7.0 mM were obtained with a suppressed conductivity system.  相似文献   

16.
Micellar electrokinetic capillary chromatography (MEKC) was examined for analysis of cefalexin and its related substances. Good selectivity was obtained with two different buffer solutions: a sodium acetate buffer (50 mM, pH 5.25) containing sodium dodecyl sulfate (50 mM SDS) or sodium phosphate buffer (40 mM, pH 7.0) containing 100 mM SDS. Both methods permit cefalexin to be completely separated from its ten related substances within 20 min. The robustness of the method, using pH 5.25 acetate buffer, was examined by means of a full-fraction factorial design to test the influence of buffer pH, concentration of SDS and buffer concentration. The parameters for validation such as linearity, precision, limit of detection and limit of quantitation are also reported. The results show that method 1 is suitable for the analysis of cefalexin.  相似文献   

17.
A sensitive chemiluminescence high-performance liquid chromatographic method has been developed for the determination of hyaluronic acid, chondroitin sulphate and dermatan sulphate as their unsaturated disaccharide-dansylhydrazine derivatives involving an effective sample clean-up system. The dansylhydrazones of the unsaturated disaccharides derived from the hyaluronic acid, chondroitin sulphate and dermatan sulphate by chondroitinase ABC and/or chondroitinase ACII, were separated by reversed-phase chromatography using a mixture of 0.1 M sodium acetate buffer (pH 6.0) and 80% acetonitrile on a column (250 mm x 4.0 mm I.D.) packed with amide-80 silica beads (5 microns diameter). For post-column elution in the chemiluminescence system, 1 mM bis[2-(3,6,9-trioxadecanyloxycarbonyl)-4-nitrophenyl]oxalate and 3mM hydrogen peroxide in acetonitrile were used. The detection limit of each glycosaminoglycan was 100 fmol. The method was applicable to the determination of the levels of hyaluronic acid, chondroitin sulphate and dermatan sulphate in rat peritoneal mast cells.  相似文献   

18.
Qi L  Han Y  Zuo M  Chen Y 《Electrophoresis》2007,28(15):2629-2634
A novel method of chiral ligand-exchange CE was developed with either L- or D-lysine (Lys) as a chiral ligand and zinc(II) as a central ion. This type of chiral complexes was explored for the first time to efficiently separate either individual pairs of or mixed aromatic amino acid enantiomers. Using a running buffer of 5 mM ammonium acetate, 100 mM boric acid, 3 mM ZnSO(4) x 7H(2)O and 6 mM L-Lys at pH 7.6, unlabeled D,L-tryptophan, D,L-phenylalanine, and D,L-tyrosine were well separated, giving a chiral resolution of up to 7.09. The best separation was obtained at a Lys-to-zinc ratio of 2:1, zinc concentration of 2-4 mM and running buffer pH 7.6. The buffer pH was determined to have a strong influence on resolution, while buffer composition and concentration impacted on both the resolution and peak shape. Boric acid with some ammonium acetate was an adoptable buffer system, and some additives like ethylene diamine tetraacetic acid capable of destroying the complex should be avoided. Fine-tuning of the chiral resolution and elution order was achieved by regulating the ratio of L-Lys to D-Lys; i.e. the resolution increased from zero to its highest value as the ratio ascended from 1:0 to 1:infinitive, and L-isomers eluted before or after D-isomers in excessive D- or L-Lys, respectively.  相似文献   

19.
励炯  孙岚  王红青  邱红钰  康健 《分析测试学报》2017,36(11):1357-1362
建立了水产品中5种硝基咪唑类药物的高效液相色谱-串联质谱检测方法。样品经含0.1%氨水乙腈提取,加无水硫酸钠、C18-N以及NH2-PSA净化剂后涡旋振荡对样品进行净化,以Merck Chromolith Performance RP-18e(4.6 mm×100 mm)色谱柱分离,甲醇和0.1%甲酸水溶液为流动相梯度洗脱,正离子模式电喷雾电离,配合多反应离子扫描(MRM)定性定量分析目标化合物。考察了提取剂中氨水和净化剂的用量对加标回收率的影响,在优化实验条件下,5种硝基咪唑类药物在20~500μg/L范围内线性关系良好,r2≥0.998 9;3个加标水平下的方法回收率为77.2%~94.8%;定量下限为0.7~2.0μg/kg。该方法快速、简单、准确,适用于水产品中5种硝基咪唑类药物残留的检测。  相似文献   

20.
A sensitive, rapid and simple high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) method for simultaneous determination of dipyridamole and salicylic acid in human plasma has been developed and validated. After the addition of diazepam and rosiglitazone as internal standard (IS), plasma samples were prepared by liquid-liquid extraction followed by an isocratic elution with methanol:2 mM ammonium acetate buffer (pH 4.25; 70/30, v/v) on a Shimadzu VP-ODS C(18) column (5 microm, 150 x 2.0 mm I.D.). Detection was performed on a quadrupole mass spectrometer with ESI interface operating in the positive-ion mode for dipyridamole and negative-ion mode for salicylic acid. Calibration curves were linear (r(2) > 0.99) over the concentration range 10-2500 ng/mL for dipyridamole and 30-4000 ng/mL for salicylic acid with acceptable accuracy and precision, respectively. The intra- and inter-batch precisions were less than 15% of the relative standard deviation. The limits of detection of dipyridamole and salicylic acid were 1 and 15 ng/mL, respectively. The validated HPLC-ESI-MS method was successfully applied to a preliminary pharmacokinetic study of fixed-dose combination of sustained-release dipyridamole/aspirin in Chinese healthy male volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号