首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An analytical method has been developed for the determination of five naturally occurring estrogens (estradiol, estriol, estrone, genistein, daidzein), one synthetic hormone (ethynylestradiol) and three xenoestrogens (4-nonylphenol (NP), 4-tert-octylphenol (4-tert-OP), bisphenol A (BPA)) in coastal marine waters. The procedure includes a solid-phase extraction of approx. fifty litres of water samples on the solid-phase copolymer Oasis HLB followed by a clean-up on silica. Twenty-five percent aliquots were used for the analytical determination of the analytes using high performance liquid chromatography coupled with electrospray-ionisation tandem mass spectrometry (HPLC-ESI-MS/MS). Calculated extraction recoveries between 52 (4-tert-octylphenol) and 91% (nonylphenol) were obtained for the method developed. Matrix interferences occurring during electrospray ionisation were quantified by spiking the extracts prior to the measurements. Method detection limits ranged from 0.02 (estrone) to 1 ng L(-1) (estriol). The method was applied to determine environmental estrogens in coastal waters of the Baltic Sea. The analyses showed the presence of five compounds at levels between 0.10 (estrone) and 17 ng L(-1) (ethynylestradiol).  相似文献   

2.
A high-performance liquid chromatographic method with diode array detection (HPLC-DAD), based on chelation with ammonium pyrrolidinedithiocarbamate (APDC), has been developed for the determination of chromium species. Determination of Cr3+, CrO42-, and Cr2O72- was performed for standards and synthetic environmental matrixes. This method is robust, rugged, and can be used for rapid routine determination of chromium species with high precision and reliability. Sample pretreatment is simple. The method is capable of discriminating not only between Cr(III) and Cr(VI) but also between the chemical forms of Cr(VI) - CrO42- and Cr2O72-. By analysis of numerous samples the method has been shown to be selective, sensitive, and free from matrix interference, which is crucial for the determination of chromium species in difficult-to-analyze environmental matrixes. This method has been validated by means of an interlaboratory study. Although different speciation techniques were used during this study, there was good agreement between results from the two laboratories. The method detection limits were 7 and 4 mg L(-1) for Cr3+ and Cr2O72-, respectively. Recoveries of the analytes from spiked samples were 98% and 100% for Cr3+ and Cr2O72-, respectively. Both were based on a 10-mL sample volume spiked with 0.4 mg L(-1) chromium.  相似文献   

3.
Xu Q  Wang M  Yu S  Tao Q  Tang M 《The Analyst》2011,136(23):5030-5037
A simple, rapid and sensitive method for the determination of diethylstilbestrol (DES), dienestrol (DE) and hexestrol (HEX) was developed by using the Nylon 6 nanofibers mat-based solid-phase extraction (SPE) coupled with liquid chromatography-tandem mass spectrometry (LC-MS). These estrogens were separated within 8 min by LC using an ODS column and methanol/water (80/20, v/v) at a flow rate of 1.0 mL min(-1). Electrospray ionization conditions in the negative ion mode were optimized for MS detection of the estrogens. Under the optimum SPE conditions, all target analytes in 50 mL environmental water samples can be completely extracted by 1.5 mg Nylon 6 nanofibers mat at flow rate of 3.0 mL min(-1) and easily eluted by passage of 500 μL mobile phase. By using the novel SPE-LC/MS method, good linearity of the calibration curve (r(2) ≥ 0.9992) was obtained in the concentration range from 0.10 ng L(-1) to 1.0 mg L(-1) (except for DE which was 0.20 ng L(-1) to 1.0 mg L(-1)) for all analytes examined. The limits of detection (S/N = 3) of the three estrogens ranged from 0.05 ng L(-1) to 0.10 ng L(-1). This method was applied successfully to the analysis of environmental water samples without any other pretreatment and interference peaks. Several water samples were collected from Jinchuan River and Xuanwu Lake, and in Jinchuan River water DES was detected at 0.13 ng L(-1). The recoveries of estrogens spiked into tap water were above 98.2%, and the relative standard deviations were below 4.78%.  相似文献   

4.
Huang Y  Zhang Q  Liu M  Wang X  Li J  He L 《色谱》2012,30(1):56-61
以莱克多巴胺为模板分子,丙烯酰胺为功能单体,乙二醇二甲基丙烯酸酯为交联剂,合成了对莱克多巴胺具有高选择性的分子印迹聚合物。考察了甲醇、乙腈、丙酮和氯仿-甲醇与三乙胺构成致孔剂合成的聚合物性能及其形貌特征。通过正交试验优化的聚合反应配方为: 1.0 mmol莱克多巴胺,4.0 mmol丙烯酰胺,20.0 mmol乙二醇二甲基丙烯酸酯,6.0 mL乙腈-三乙胺(30:1, v/v), 50.0 mg偶氮二异丁腈。建立的基于分子印迹固相萃取-高效液相色谱测定饲料试样中莱克多巴胺的方法,在0.50~100 mg/L质量浓度范围内有良好的线性关系(r=0.9994);饲料试样中1.0、10及100 mg/kg 3个添加水平的莱克多巴胺平均回收率大于80%;批内、批间测定的相对标准偏差小于10%;检出限(信噪比为3)达到0.1 mg/kg。该方法灵敏、可靠,用于饲料等复杂基质中莱克多巴胺检测的效果优于相关标准分析方法。  相似文献   

5.
In this work, a fast, simple and economic method is proposed for the determination of imazalil in water samples by flow injection photoinduced chemiluminescence. In this method, imazalil degrades in basic media through the use of a photoreactor, and the resulting photofragments react with ferricyanide and generate the direct chemiluminescence signal. To the authors' knowledge, this is the first time that a chemiluminescence method has been proposed for the determination of this fungicide. All physical and chemical parameters in the flow injection chemiluminescence system were optimized in the experimental setting. In the absence of preconcentration, the linear dynamic range for imazalil was 0.75-5 mg L(-1) and the detection limit was 0.171 mg L(-1). The application of solid-phase extraction with C18 cartridges allowed the elimination of interference ions, the reduction of the linear dynamic range to 15-100 μg L(-1), and a detection limit of 3.4 μg L(-1). This detection limit is below the maximum concentration level established by the Regulations of the Hydraulic Public Domain for pesticide dumping. The sample throughput after solid-phase extraction of the analyte was 12 samples h(-1). The intraday and interday coefficients of variation were below 9.9% in all cases. This method was applied to the analysis of environmental water samples, and recoveries of between 95.7 and 110% were obtained.  相似文献   

6.
Determination of polybrominated diphenyl ethers (PBDEs) in environmental samples has raised great concerns due to the widespread use of PBDEs and their potential risk to humans. Solid-phase microextraction (SPME) is a fast, simple, cost-effective, and green sample preparation technique and is widely used for environmental analysis, but reports on the application of SPME for determination of PBDEs are very limited, and only a few publications dealing with commercial SPME fibers are available for extraction of PBDEs. Herein, we report a novel SPME method using multiwalled carbon nanotubes (MWCNTs) as the SPME fiber coating for gas chromatography with electron-capture detection (GC-ECD) of PBDEs in environmental samples. The MWCNTs coating gave much higher enhancement factors (616-1756) than poly (5% dibenzene-95% dimethylsiloxane) coating (139-384) and activated carbon coating (193-423). Thirty-minute extraction of 10 mL of sample solution using the MWCNTs coated fiber for GC-ECD determination yielded the limits of detection of 3.6-8.6 ng L(-1) and exhibited good linearity of the calibration functions (r(2)>0.995). The precision (RSD%, n=4) for peak area and retention time at the 500 ng L(-1) level was 6.9-8.8% and 0.6-0.9%, respectively. The developed method was successfully applied for the analysis of real samples including local river water, wastewater, and milk samples. The recovery of the PBDEs at 500 ng L(-1) spiked in these samples ranged from 90 to 119%. No PBDEs were detected in the river water and skimmed milk samples, whereas in the wastewater sample, 134-215 ng L(-1) of PBDEs were found. The PBDEs were detected in all whole fat milk samples, ranging from 13 to 484 ng L(-1). In a semiskimmed milk sample, only BDE-47 was found at 21 ng L(-1).  相似文献   

7.
固相萃取-气相色谱法测定茶叶中残留的92种农药   总被引:13,自引:5,他引:8  
建立了茶叶中92种农药多残留的气相色谱分析方法。茶叶样品用乙腈一次性提取后,有机磷类农药经Envi-Carb固相小柱净化,用10 mL乙腈-甲苯(体积比为3∶1)洗脱剂淋洗,气相色谱-火焰光度检测器(GC-FPD)检测;有机氯类和拟除虫菊酯类农药经串联Envi-Carb和NH2固相小柱净化,用5 mL乙腈-甲苯(体积比为3∶1)洗脱剂淋洗,GC-电子捕获检测器(ECD)检测。采用外标法定量。添加回收试验的结果表明:92种农药的平均回收率为80.3%~117.1%,相对标准偏差为1.5%~9.8%。方法的检出限为0.0025~0.10 mg/kg。该方法的灵敏度、准确度和精密度均符合农药残留测定的技术要求。  相似文献   

8.
The aim of this work was to develop a fast method using capillary electrophoresis for the determination of creatinine in human urine samples. The pH and constituents of the background electrolyte were selected by inspection of effective mobility of creatinine and candidate urine interferents versus pH curves. The tendency of the analyte to undergo electromigration dispersion and the buffer capacity were evaluated by the Peakmaster software and considered in the optimization of the background electrolyte, composed by 10 mmol L(-1) tris(hydroxymethyl)aminomethane and 20 mmol L(-1) 2-hydroxyisobutyric acid (HIBA) at pH 3.93. Separation was conducted in a fused-silica capillary (32 cm total length and 8.5 cm effective length, 50 microm I.D.), with short-end injection configuration and direct UV detection at 215 nm. The migration time of creatinine was only 22s. A few figures of merit of the method are as follows: good linearity in the concentration interval of 5-70 mg L(-1) (R(2)>0.99), limit of detection of 0.5 mg L(-1), inter-day precision better than 2.7% (n=9) and recovery in the range 99.0-103.7% at three concentration levels (50, 100 and 150 mg L(-1)). Urine samples were prepared by deproteination with acetonitrile (1:3 sample:acetonitrile, v/v), centrifugation and dilution of a deproteinated aliquot with 12.5 mmol L(-1) HIBA (1:4, v/v). Creatinine concentrations between 489 and 1063 mg L(-1) were obtained in the urine of four healthy volunteers.  相似文献   

9.
A method has been developed for the determination of zinc pyrithione (ZnPT) in environmental water samples using monolithic reversed-phase silica columns for rapid on-line large volume solid phase extraction in tandem with on-line matrix removal using sacrificial strong anion exchange (SAX) columns. This is coupled with reversed-phase liquid chromatography with atmospheric pressure chemical ionisation mass spectrometric detection. Limits of detection in spiked river water samples, using a 200 mL preconcentration volume, were determined as 18 ng L(-1), with a limit of quantitation of 62 ng L(-1). The percentage recovery from spiked river water was found to be 72+/-9 (n=3 extractions), whilst overall method precision, following 10 repeat complete analyses was found to be 27% RSD at 1 microg L(-1). Linearity was determined over the concentration range of 0.25-10 microg L(-1) and the calculated regression coefficient was R(2)=0.9802. The method was used to investigate the environmental fate of zinc pyrithione in waters and its partition coefficient between sediment and water phases.  相似文献   

10.
建立固相萃取与电感耦合等离子体原子发射光谱法(ICP–AES)测定环境水样中Cr(Ⅲ)含量的方法。合成了功能化铁氧体磁性材料作为固相萃取剂,优化了固相萃取条件。当样品溶液的p H值为2.5时,固相萃取剂能在5 min内完成Cr(Ⅲ)的富集。使用1 mol/L HNO3在3 min内即可解吸附分离Cr(Ⅲ),饱和吸附容量为15.2μg/mg,研究了共存离子的影响。Cr(Ⅲ)含量在1~50μg/L范围内与发射光谱强度呈良好的线性关系,线性相关系数为0.999 9,检出限为0.09μg/L,测定结果的相对标准偏差为2.2%(n=8),回收率为97.7%~104.8%。该方法高效、快速,测定结果准确可靠,可用于测定环境水样品中的痕量Cr(Ⅲ)。  相似文献   

11.
环境水样中9种三唑类农药的固相萃取-气相色谱-质谱分析   总被引:4,自引:0,他引:4  
游明华  孙广大  陈猛  袁东星 《色谱》2008,26(6):704-708
应用C18柱萃取/富集,NH2柱净化,气相色谱-质谱联用技术检测,建立了环境水样中9种三唑类农药同时分析的方法。9种目标农药在0.025~0.500 mg/L质量浓度范围内线性关系良好,方法的检出限为0.002~0.009 μg/L。以实际水样为基底,加标质量浓度为0.025 μg/L和0.100 μg/L时,9种目标农药的基底加标回收率和相对标准偏差(n=3)分别为68.4%~113.9%,1.6%~6.9%(河水)和70.3%~115.2%,0.8%~8.2%(海水)。该方法操作简单、灵敏度高、选择性好,符合多种农药残留分析的要求,并成功地应用于福建九龙江河口区表层水样中三唑类农药的残留状况调查。  相似文献   

12.
A complete analytical procedure, including sample clean-up and a micellar electrokinetic chromatographic method, is presented for the determination of sulfamethoxazole, trimethoprim, and their main metabolites by using 20 mmol L(-1) borate buffer (pH 9.3), 25 mmol L(-1) sodium dodecylsulfate, and 5% v/v acetonitrile as electrolyte. The separation was carried out at 30 kV and 20 degrees C in a fused silica capillary (60.2 cm x 75 microm inner diameter) fitted with a window in the capillary cartridge of 100 x 800 microm. The detector response was linear from the limit of quantification to 3 mg L(-1) for the individual components. The limits of quantification ranged from 0.13 up to 0.24 mg L(-1). The method was applied to human serum, previously spiked at different concentrations of all the analytes, and recoveries between 95% and 108% were obtained.  相似文献   

13.
Capillary zone electrophoresis was employed for the determination of histamine using end-column amperometric detection with a carbon fiber microelectrode, at a constant potential. The optimum conditions of separation and detection were 10 mmol/L phosphate buffer, pH 5.6 for the buffer solution, 15 kV for the separation voltage, and 1.35 V (versus SCE) for the detection potential. The linear range was from 6.3 x 10(-7) to 1.5 x 1(-5) mol/L with the regression coefficient of 0.9997, and the detection limit was 4.0 x 10(-7) mol/L (S/N = 3). The proposed method was successfully applied to the direct determination of histamine in the beer samples without any sample clean-up procedures.  相似文献   

14.
赵海香  刘海萍  闫早婴 《色谱》2014,32(3):294-298
建立了多壁碳纳米管为吸附剂的固相萃取净化-高效液相色谱-紫外检测测定猪肉和鸡肉中多种磺胺类药物多残留的方法。样品采用乙腈提取,多壁碳纳米管固相萃取净化,NaH2PO4缓冲溶液(pH 5.5~6.0)溶解上样,5%(v/v)丙酮-正己烷淋洗,丙酮-二氯甲烷(1:1,v/v)洗脱。色谱分离以50 mmol/L NaH2PO4-乙腈(7:3,v/v)为流动相,方法的线性范围为0.01~1.00 mg/L,线性相关系数大于0.998,检出限(LOD)为0.003 mg/L,定量限(LOQ)为0.01 mg/L。在0.02~0.2 mg/kg添加范围内,9种磺胺类药物的回收率高于70%,RSD低于8%,表明多壁碳纳米管对磺胺类药物具有较强的吸附富集能力。该方法简便、准确可用于动物组织及产品中磺胺药物残留的检测。  相似文献   

15.
With polyamide( PA)as an efficient sorbent for solid phase extraction( SPE)of Sudan dyes II,III and Red 7B from saffron and urine,their determination by HPLC was performed. The optimum conditions for SPE were achieved using 7 mL methanol/water( 1:9,v/v,pH 7)as the washing solvent and 3 mL tetrahydrofu-ran for elution. Good clean-up and high( above 90%)recoveries were observed for all the analytes. The opti-mized mobile phase composition for HPLC analysis of these compounds was methanol-water( 70:30,v/v). The SPE parameters,such as the maximum loading capacity and breakthrough volume,were also determined for each analyte. The limits of detection( LODs),limits of quantification( LOQs),linear ranges and recoveries for the analytes were 4. 6-6. 6 μg/L,13. 0-19. 8 μg/L,13. 0-5 000 μg/L( r2> 0. 99)and 92. 5% -113. 4%,respec-tively. The precisions( RSDs)of the overall analytical procedure,estimated by five replicate measurements for Sudan II,III and Red 7B in saffron and urine samples were 2. 3%,1. 8% and 3. 6%,respectively. The developed method is simple and successful in the application to the determination of Sudan dyes in saffron and urine sam-ples with HPLC coupled with UV detection.  相似文献   

16.
A new method for simultaneous determination of underivatized biogenic amines based on the separation by cation-exchange chromatography and suppressed conductivity coupled with mass spectrometry detection has been developed. The method has been applied to the analysis of cadaverine, putrescine, histamine, agmatine, phenethylamine and spermidine in processed meat products. The amines were extracted from muscle tissue with methanesulfonic acid without any additional derivative step or sample clean-up. Biogenic amines were separated by the IonPac CS17 column, a cation-exchange column used with gradient elution, and detection was done by suppressed conductivity and mass spectrometry. Tyramine was simultaneously analysed by using a spectrophotometer (275 nm) before the suppressed conductivity detection. Linearity of response was obtained in the range 0.25-25 microg mL(-1). The detection limits ranged from 23 microg L(-1) for putrescine to 155 microg L(-1) for spermidine (suppressed conductivity) and from 9 microg L(-1) for agmatine to 34 microg L(-1) for spermidine (MS). Average recoveries from meat samples ranged from 85 to 97% and coefficients of variation ranged from 4.5 to 9.7%. The analysis of biogenic amines in fresh and processed meats (dry-cured, cooked and fermented products) can be used as a quality marker of raw material and for studying the relationship between their changes and the fermentation process involved in dry sausage ripening.  相似文献   

17.
Determination of phosphorus in small amounts of protein samples by ICP–MS   总被引:3,自引:0,他引:3  
Inductively coupled plasma mass spectrometry (ICP-MS) is used for phosphorus determination in protein samples. A small amount of solid protein sample (down to 1 micro g) or digest (1-10 micro L) protein solution was denatured in nitric acid and hydrogen peroxide by closed-microvessel microwave digestion. Phosphorus determination was performed with an optimized analytical method using a double-focusing sector field inductively coupled plasma mass spectrometer (ICP-SFMS) and quadrupole-based ICP-MS (ICP-QMS). For quality control of phosphorus determination a certified reference material (CRM), single cell proteins (BCR 273) with a high phosphorus content of 26.8+/-0.4 mg g(-1), was analyzed. For studies on phosphorus determination in proteins while reducing the sample amount as low as possible the homogeneity of CRM BCR 273 was investigated. Relative standard deviation and measurement accuracy in ICP-QMS was within 2%, 3.5%, 11% and 12% when using CRM BCR 273 sample weights of 40 mg, 5 mg, 1 mg and 0.3 mg, respectively. The lowest possible sample weight for an accurate phosphorus analysis in protein samples by ICP-MS is discussed. The analytical method developed was applied for the analysis of homogeneous protein samples in very low amounts [1-100 micro g of solid protein sample, e.g. beta-casein or down to 1 micro L of protein or digest in solution (e.g., tau protein)]. A further reduction of the diluted protein solution volume was achieved by the application of flow injection in ICP-SFMS, which is discussed with reference to real protein digests after protein separation using 2D gel electrophoresis.The detection limits for phosphorus in biological samples were determined by ICP-SFMS down to the ng g(-1) level. The present work discusses the figure of merit for the determination of phosphorus in a small amount of protein sample with ICP-SFMS in comparison to ICP-QMS.  相似文献   

18.
A method suitable for the determination of unmetabolized polycyclic aromatic hydrocarbons (PAHs) excreted at trace levels (ng/L) in human urine for the monitoring of exposure of the general population to PAH contamination was developed. PAHs were determined, after enrichment by solid-phase extraction on polyurethane foam (PUF) chips, by HPLC with fluorescence detection. Different parameters affecting analyte extraction to the PUF, including urine salting-out and organic additives, and optimization of conditions for clean-up and desorption have been investigated. Optimized conditions were 40 mL acidified urine sample, added with magnesium sulfate, tetrahydrofuran and a 2 cm3 PUF chip, and extracted by shaking at 30 rpm for 1 h at ambient temperature. Desorption was performed, after a clean-up step with diluted sodium hydroxide, using a small amount of diethyl ether. The recovery of PAH congeners from spiked urines was >90% in the 2-100 ng/L range; the detection limit was 0.1-0.5 ng/L, depending on the considered PAH congener; day-to-day precision, at 50 ng/L native PAH content, was CV = 10-20%. The proposed technique provides a simple, economical and effective procedure for the determination of trace amounts of unmetabolized PAHs excreted in human urine spot samples.  相似文献   

19.
An isotope-dilution electrospray ionization tandem mass spectrometry (ESI-MS/MS) method with an on-line sample clean-up device, for the quantitative analysis of human urine for the benzene exposure biomarker S-phenylmercapturic acid (SPMA), was developed and validated. The sample clean-up system was constructed from an autosampler, a reversed-phase C18 trap cartridge, a two-position switching valve, and controlling computer software and hardware. The sample clean-up system was interfaced via 1/20 splitting to the ESI source of a triple-quadrupole mass spectrometer using negative ion mode and multiple reaction monitoring for SPMA and the isotope-labeled internal standard. A strategy was adopted to acquire pooled blank urine matrix and quality control samples spiked with standards. Validated procedures and data on method specificity, detection limits, standard curves, precision and recovery, sample storage stability, and inter-laboratory comparison are presented. The analytical system was fully automated. No tedious manual sample clean-up procedures are required. With the selectivity and the sensitivity provided by ESI-MS/MS detection, the analytical system can be used for high-throughput and accurate determination of SPMA levels in human urine samples, as a biomarker for environmental as well as occupational benzene exposure.  相似文献   

20.
A simple and efficient method for multiple determination of 77 pesticides, including one organonitrogen, eight carbamate, 12 pyrethroid, 26 organochloride, 30 organophosphorous compounds, in textiles is developed. Six representative textiles are chosen as test samples. Extraction using hexane-ethyl acetate (1:1) assisted by ultrasonic processor is carried out twice, followed by clean-up using solid-phase extraction on a florisil column. The final solution is analyzed using gas chromatography-mass spectrometry, and 77 pesticides are determined. This method is highly sensitive, selective, and reproducible, with a broad linear range and reliable accuracy. Six blank samples are spiked with 0.50 and 2.00 mg/kg of the 77 pesticides, and the corresponding recoveries are between 64.5% and 99.1%; the precisions range from 4.04% to 14.78%; and the minimum detection limits of this method are 0.02-0.20 mg/kg.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号