首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
For this study, multiphoton ionization/mass spectrometry using an ultraviolet (UV) femtosecond laser was employed for the trace analysis of organic compounds. Some of the molecules, such as dioxins, contain several chlorine atoms and have short excited-state lifetimes due to a "heavy atom" effect. A UV femtosecond laser is, then, useful for efficient resonance excitation and subsequent ionization. A technique of multiphoton ionization using an extremely short laser pulse (e.g., <10 fs), referred to as "impulsive ionization," may have a potential for use in fragmentation-free ionization, thus providing information on molecular weight in mass spectrometry.  相似文献   

2.
Defined by their solubility in toluene and insolubility in n-heptane, asphaltenes are a highly aromatic, polydisperse mixture consisting of the heaviest and most polar fraction of crude oil. Although asphaltenes are critically important to the exploitation of conventional oil and are poised to rise in significance along with the exploitation of heavy oil, even as fundamental a quantity as their molecular weight distribution is unknown to within an order of magnitude. Laser desorption/ionization (LDI) mass spectra vary greatly with experimental parameters so are difficult to interpret: some groups favor high laser pulse energy measurements (yielding heavy molecular weights), arguing that high pulse energy is required to detect the heaviest components of this mixture; other groups favor low pulse energy measurements (yielding light molecular weights), arguing that low pulse energy is required to avoid aggregation in the plasma plume. Here we report asphaltene mass spectra recorded with two-step laser mass spectrometry (L2MS), in which desorption and ionization are decoupled and no plasma is produced. L2MS mass spectra of asphaltenes are insensitive to laser pulse energy and other parameters, demonstrating that the asphaltene molecular weight distribution can be measured without limitation from insufficient laser pulse energy or plasma-phase aggregation. These data resolve the controversy from LDI, showing that the asphaltene molecular weight distribution peaks near 600 Da and previous measurements reporting much heavier species suffered from aggregation effects.  相似文献   

3.
Appling JR  Bland DD 《Talanta》1992,39(8):883-886
A Nd: YAG laser has been used to perform IR desorption of analytes followed by UV ionization, all within the same laser pulse. At moderate laser powers, mass spectra recorded using this method are dominated by molecular ions.  相似文献   

4.
Both the techniques mentioned provide molecular weight and structural information, but laser microprobe mass spectrometry (LMMS) also provides greater control over the degree of fragmentation and enhanced sensitivity. In addition, LMMS allows microprobe analysis (i.e., spatial resolution of a few μm2) as well as providing quantitative measurements. The less energetic nature of fast-atom-bombardment mass spectrometry (FAB-MS) makes it more suitable for the analysis of highly labile polar compounds and high-mass biopolymers.  相似文献   

5.
基体辅助激光解吸质谱法测定蛋白质分子量   总被引:1,自引:0,他引:1  
钟峰  赵善楷 《化学学报》1995,53(9):889-894
本文叙述用自行研制成功的激光微探针飞行时间质谱仪及采用基体辅助激光解吸的新方法, 对溶菌酶、细胞色素C、肌红蛋白、胰蛋白酶、蛋白酶、白蛋白等多种蛋白质的分子量进行测定, 并对蛋白质混合物进行分析, 得一以满意的结果。此方法测定蛋白质分子量具有速度快(十分钟一个样品), 准确度高(±1%-0.1%), 灵敏度高(10^-^1^2~10^-^1^5mol)等优点, 是传统生物方法难以比拟的。  相似文献   

6.
7.
The influence shaped femtosecond laser pulses have on molecular photofragmentation and ionization, coupled with the intrinsic sensitivity of mass spectrometry, results in a powerful tool for fast, accurate, reproducible and quantitative isomeric identification. Complex phase functions are introduced to enhance differences during the laser-molecule interactions, which depend on geometric structure, resulting in different fragmentation fingerprints. A full account is given on the setup and results leading to a technique that can be used to distinguish between compounds normally indistinguishable by conventional electron ionization mass spectrometry. We demonstrate geometric and structural isomer identification of cis-/trans-3-heptene, cis-/trans-4-methyl-2-pentene, o-/p-cresol and o-/p-xylene. For the positional isomers of xylene we present a complete dataset consisting of 1024 different phases to explore phase complexity. A selection of two phases from that data can then be used to achieve quantitative identification in mixtures of xylene isomers. Finally, we evaluate receiver operational curves obtained from our experimental data to demonstrate the reliability that can be achieved by femtosecond laser control mass spectrometry.  相似文献   

8.
Circular dichroism in ion yield has promising new potentials for chiral analysis. Our progress of its development is described here. Circular dichroism in ion yield is achieved by resonance-enhanced multiphoton ionization. The feasibility of circular dichroism spectroscopy and quantitative determination of circular dichroism by this method is demonstrated. Several excitation schemes have been applied using different types of lasers, which vary in wavelength and repetition rate. Progress to improve the statistical error and thus the lower limit of measurable circular dichroism is described. This is achieved by adding achiral compounds or racemic mixtures of chiral compounds to the sample gas as reference substances and ionizing them by the same laser pulse. Therefore, in the mass spectrum of every single laser pulse, ion signals of sample and reference species appear both being subject to the same kind of instrumental fluctuations (in particular of laser pulse energy). In another approach, a laser repetition rate of 200 Hz allowed averaging of large numbers of laser pulses.   相似文献   

9.
This paper presents a set of data which compares the potential and limitations of laser microprobe mass spectrometry (TOF-LMMS and FT-LMMS) and static secondary ion mass spectrometry (S-SIMS) for inorganic speciation at a microscopical level. In general LMMS yields prominent signals of adduct ions consisting of the intact molecule combined with a stable ion, which allows a direct identification of the analyte. S-SIMS also yields abundant diagnostic signals to specify the molecular composition. However, adduct ions are not always present, which means that the identification often relies on fingerprinting. Results further indicate that the potential and the application area of S-SIMS and FT-LMMS are complementary to one another.  相似文献   

10.
Of all the inorganic mass spectrometric techniques, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) plays a key role as a powerful and sensitive microanalytical technique enabling multi- element trace analysis and isotope ratio measurements at trace and ultratrace level. LA-ICP-MS was used to produce images of detailed regionally-specific element distribution in 20 microm thin sections of different parts of the human brain. The quantitative determination of copper, zinc, lead and uranium distribution in thin slices of human brain samples was performed using matrix-matched laboratory standards via external calibration procedures. Imaging mass spectrometry provides new information on the spatially inhomogeneous element distribution in thin sections of human tissues, for example, of different brain regions (the insular region) or brain tumor tissues. The detection limits obtained for Cu, Zn, Pb and U were in the ng g(-1) range. Possible strategies of LA-ICP-MS in brain research and life sciences include the elemental imaging of thin slices of brain tissue or applications in proteome analysis by combination with matrix-assisted laser desorption/ionization MS to study phospho- and metal- containing proteins will be discussed.  相似文献   

11.
This paper describes the use of double-pulse laser ablation to improve ICP-MS internal (temporal relative standard deviation, %TRSD) and external (%RSD) precision. The first laser pulse is used to ablate a large quantity of mass from the sample surface. The second pulse is applied with a variable time delay after the first pulse to break the ablated mass into a finer aerosol, which is more readily transported to and digested in the ICP-MS. A factor of two improvement in %TRSD and factor of five in %RSD are demonstrated.  相似文献   

12.
Summary A double focusing mass spectrometer was equipped with a laser plasma ion source. This instrument has been used for multi-element analysis of solid materials. Laser plasma mass spectrometry (LMS) permits direct analysis of both conducting and non-conducting samples. The abundances of about 30 trace elements can be determined simultaneously in rock samples. A great advantage of LMS is that most elements are ionized with about the same efficiency, this means that only small corrections are necessary for quantitative analysis. Solutions which have been dried on a quartz disk can also be analyzed. This technique yields mass spectra which are free of interferences of molecules or cluster-ions.
Spurenelementanalyse durch Laser-Plasma-Massenspektrometrie
  相似文献   

13.
A new photocleavable molecule for laser desorption ionization mass spectrometry (LDI-MS) was designed and synthesized. The molecule exhibited high sensitivity for negative mode MS detection with good chemical stability. The molecule was successfully applied to molecular tag for (LDI-MS). Kinetic measurement of the amidation reaction and monitoring of aminolysis of acetylated sugars were demonstrated with the molecular tag.  相似文献   

14.
Visible matrix-assisted laser desorption/ionization (VIS-MALDI) was performed using 2-amino-3-nitrophenol as matrix. The matrix is of near-neutral pH, and has an optical absorption band in the near-UV and visible region. A frequency-doubled Nd:YAG laser operated at 532 nm wavelength was used for matrix excitation and comparisons were made with a frequency-tripled Nd:YAG laser (355 nm). Visible and ultraviolet (UV)-MALDI produce similar mass spectra for peptides, polymers, and small proteins with comparable sensitivities. Due to the smaller optical absorption coefficient of the matrix at 532 nm wavelength, the optical penetration depth is larger, and the sample consumption per laser shot in VIS-MALDI is higher than that of UV-MALDI. Nevertheless, VIS-MALDI using 2-amino-3-nitrophenol as matrix may offer a complementary technique to the conventional UV-MALDI method in applications where deeper laser penetration is required.  相似文献   

15.
An intermolecular alkyl transfer reaction (ATR) leading to ion-pair formation has been observed for internal salts by using laser mass spectrometry (l.m.s.). Positive- and negative-ion spectra both show evidence for alkyl transfer. Both the LAMMA-500 (transmission) and LAMMA-1000 (reflection) laser mass spectrometers were used. The positive-ion laser mass spectra obtained by these two instruments show some significant differences; no significant differences were observed in the negative-ion spectra. Results obtained for quaternary ammoniohexanoates as a function of laser power indicate that the extent of ATR is greater at high laser power. Addition of a small amount of p-toluenesulfonic acid to the ammoniohexanoates reduces fragmentation and enhances the intensity of the quasimolecular ion (M + H)+ relative to ATR. Results from deuterated sultaines were used to confirm intermolecular alkyl transfer and to elucidate some fragmentation processes. Field-desorption (f.d.) mass spectra of internal salts show similarities and differences from l.m.s.; not all internal salts showed the alkyl transfer reaction in f.d. Cluster ion formation was observed in f.d.m.s. but not in l.m.s.  相似文献   

16.
Metal labelling of peptides and proteins using high-affinity metal-chelating compounds has found widespread applications in the medical and bioanalytical fields. In the present study we investigated the analysis of peptides derivatized either with cysteine- or amino group-directed metal-bound DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) chelators in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The metal complexes of DOTA were shown to be stable under MALDI-MS conditions. The introduction of the metal label led in a number of cases to significantly increased signal-to-noise (S/N) values and thus improved sensitivity of the labelled peptides compared to their unlabelled counterparts, especially for multiply labelled peptides. The presence of the labels did alter the tandem mass spectrometric (MS/MS) behaviour, namely the formation of sequence specific a-, b- and y-ion series, in dependence of the position of the label within the peptide sequence. For cysteine-derivatized peptides several label-specific reporter ions and characteristic immonium ions could be identified. Amino-directed labelling led only to the formation of characteristic immonium ions in ε-amino groups of lysine, whereas N-terminal labelling in some cases led to the formation of a(1)- and b(1)-ions. The results clearly show that MALDI-MS is suitable for the analysis of metal-labelled peptides, which was also confirmed in liquid chromatography (LC)/MALDI-based identification of proteins in a model protein mixture labelled with Cys-reactive DOTA. Here, in comparison to a run with alkylated cysteines, more than 50% more cysteine-containing peptides were identified.  相似文献   

17.
Summary A simple method for obtaining laser mass spectra (LMS) of liquids is described using a nitrocellulose membrane or fibrous material as the sample substrate. Laser mass spectra of liquids are presented along with those of solutes in aqueous systems. The use of a liquid matrix with the laser soft ionization method enhances molecular ion formation. Results are presented for charge-transfer derivatization and the influence of solution pH on LMS.  相似文献   

18.
The possibilities of laser mass spectrometry in determining the main composition of silicon carbonitride films (SiC x N y ) deposited on a substrate made of germanium and gallium arsenide are considered. The conditions of laser sampling were selected and the instrument was adjusted to identify the major components of films synthesized by the plasma deposition. The instrument was calibrated by neat silicon compounds to obtain quantitative data on the concentrations of carbon, nitrogen, oxygen, and silicon. A calibration method was proposed, and the concentration of hydrogen in the layers of silicon carbonitride was estimated.  相似文献   

19.
20.
Taxanes are biologically active compounds that have been extensively used in pharmacology for their powerful anticancer properties. High specificity and low level sensitivity for analysis of these compounds have been obtained with reversed-phase high-pressure liquid chromatography/mass spectrometry (RP-HPLC/MS), but the number of applications of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) for low molecular weight analytes is rapidly growing. A new MALDI-MS approach for the rapid screening of a variety of taxanes and a tandem mass spectrometric (MS/MS) analysis of the most important and diagnostic taxane fragmentation pathways are proposed. A solid-phase extraction method followed by preliminary quantification is also reported.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号