首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Chiral-modified silica-based monoliths have become well-established stationary phases for both high performance liquid chromatography (HPLC) and capillary electrochromatography (CEC). The silica-based monoliths were fabricated either in situ in the capillaries for nano-HPLC and CEC or in a mould for “conventional” HPLC. The present review summarizes the chiral modification of silica monoliths and the recent development in the field of enantioselective separations by nano-HPLC and CEC.  相似文献   

2.
Qu Q  Tang X  Wang C  Yang G  Hu X  Lu X  Liu Y  Yan C 《Journal of separation science》2006,29(13):2098-2102
Fused-silica capillarieswere packed with porous 1 microm bare silica microspheres and immobilized by potassium silicate-formamide in order to obtain columns with silica-based monolithic packing. After curing, the particle-fixed monolithic columns were octadecylated insitu with dimethyloctadecylchlorosilane. The columns were mechanically strong and permeable. No noticeable loss in efficiency was found after using a column continuously for 1 month. The performances of the particle-fixed silica monolithic columns were evaluated for CEC under RP conditions. High separation efficiency (about125 200 plates/m) was obtained by using these new types of columns.  相似文献   

3.
Amylose tris(5-chloro-2-methylphenylcarbamate) was coated onto native and aminopropylsilanized silica in order to prepare chiral stationary phases (CSP) for enantioseparations using nano-liquid chromatography (nano-LC) and capillary electrochromatography (CEC). The effect of the nature of silica, the particle size and pore diameter, the chiral selector loading onto silica, the mobile phase composition and pH, as well as separation variables such as a linear flow rate of the mobile phase, applied voltage in CEC, etc. on the separation of enantiomers was studied. It was found that CSPs based on amylose tris(5-chloro-2-methylphenylcarbamate) can be used for preparation of stable capillary columns for enantioseparations by nano-LC and CEC in combination with polar organic and aqueous–organic mobile phases. Higher peak efficiency was observed in CEC than in nano-LC.  相似文献   

4.
Silica monoliths coated with functionalised latex particles have been prepared for use in monolithic ion-exchange capillary electrochromatography (IE-CEC) for the separation of inorganic anions. The ion-exchange monoliths were prepared using 70 nm quaternary ammonium, anion-exchange latex particles, which were bound electrostatically to a monolithic silica skeleton synthesised in a fused silica capillary. The resulting stationary phases were characterised in terms of their chromatographic performance and capacity. The capacity of a 50 microm diameter 25 cm latex-coated silica monolith was found to be 0.342 nanoequivalents and 80,000 theoretical plates per column were typically achieved for weakly retained anions, with lower efficiency being observed for analytes exhibiting strong ion-exchange interaction with the stationary phase. The electroosmotic flow (EOF) was reversed after the latex-coating was applied (-25.96 m2 V(-1) s(-1), relative standard deviation (RSD) 2.8%) and resulted in anions being separated in the co-EOF mode. Ion-exchange interactions between the analytes and the stationary phase were manipulated by varying the ion-exchange selectivity coefficient and the concentration of a competing ion (phosphate or perchlorate) present in the electrolyte. Large concentrations of competing ion (greater than 1M phosphate or 200 mM perchlorate) were required to completely suppress ion-exchange interactions, which highlighted the significant retention effects that could be achieved using monolithic columns compared to open tubular columns, without the problems associated with particle-packed columns. The latex-coated silica monoliths were easily produced in bulk quantities and performed reproducibly in acidic electrolytes. The high permeability and beneficial phase ratio makes these columns ideal for micro-LC and preconcentration applications.  相似文献   

5.
In the last decade, silica monolithic capillaries have focused more and more attention on miniaturized separation techniques like capillary electrochromatography (CEC), nano-liquid chromatography (nano-LC) and chip electrochromatography owing to their unique chromatographic properties and their simplified preparation compared with packed columns. They are synthesized according to a sol-gel multi-step process that includes, after a gelation step at 40 degrees C leading to the formation of the macropores network and the silica skeleton, a post-gelation step (hydrothermal treatment at 120 degrees C in basic medium) that allows to tailor the mesopores and finally a calcination or a washing step to remove remaining polymers. In order to reduce the synthesis time, the number of synthesis steps and above all the temperature synthesis, to adapt the synthesis of such silica monoliths in polymeric microsystem devices, we extensively studied the influence of the hydrothermal treatment and its duration on textural (pore size distribution) and chromatographic properties (retention, efficiency) of in situ-synthesized capillary monoliths in nano-LC and CEC. This study was performed on pure silica and octyl chains grafted silica monoliths. Untreated monoliths show small pores (<6 nm), whereas hydrothermally treated monoliths exhibit medium and large mesopores (8-17 nm). It was demonstrated that the hydrothermal treatment at 120 degrees C was not necessary for pure silica monolithic capillaries dedicated to normal phase liquid chromatography or hydrophilic interaction liquid chromatography (HILIC) and electrochromatography: the suppression of the hydrothermal treatment did not impair efficiencies in CEC and in nano-LC but contributed to increase in retention factors. Minimal plate heights of ca. 5 microm in CEC and 6 microm in nano-LC were obtained with or without hydrothermal treatment with bare silica. In the same way, the hydrothermal treatment was not necessary for grafted silica monoliths only dedicated to CEC. However, the results clearly indicate that the hydrothermal treatment becomes essential before grafting in order to preserve the efficiency of the monolithic silica capillaries dedicated to nano-LC: in this particular case, the suppression of the hydrothermal treatment leads approximately to a loss of a factor two in efficiency.  相似文献   

6.
A hydride-based octadecyl stationary phase on both 4.0 and 1.8 microm silica particles is tested in both the capillary LC and the pressurized capillary electrochromatography (pCEC) modes. These two materials are compared to standard C18 stationary phase made by organosilanization and to the hydride material packed into a convention 4.6mm I.D. column. The performance of the capillary columns is evaluated in terms of analysis times for various mixtures as well as efficiency. Of particular interest are the differences between the LC mode where only laminar flow is present and pCEC operation where a flat electrodriven flow profile is superimposed on the parabolic pressurized flow. Differences in performance between columns packed with 4.0 and 1.8 microm particle silica are also evaluated.  相似文献   

7.
A new vinyltrimethoxysilane‐based hybrid silica monolith was developed and used as a reversed‐phase capillary column. The synthesis of this rich vinyl hybrid macroporous monolith, by cocondensation of vinyltrimethoxysilane with tetramethoxysilane, was investigated using an unconventional (formamide, nitric acid) porogen/catalyst system. A macroporous hybrid silica monolith with 80% in mass of vinyltrimethoxysilane in the feeding silane solution was obtained and compared to a more conventional low vinyl content hybrid monolith with only of 20% vinyltrimethoxysilane. Monoliths were characterized by scanning electron microscopy, 29Si nuclear magnetic resonance spectroscopy and N2 adsorption–desorption. About 80% of the vinyl precursor was incorporated in the final materials, leading to 15.9 and 61.5% of Si atoms bonded to vinyl groups for 20% vinyltrimethoxysilane and 80% vinyltrimethoxysilane, respectively. The 80% vinyltrimethoxysilane monolith presents a lower surface area than 20% vinyltrimethoxysilane (159 versus 551 m2/g), which is nevertheless compensated by a higher vinyl surface density. Chromatographic properties were evaluated in reversed‐phase mode. Plots of ln(k) versus percentage of organic modifier were used to assess the reversed‐phase mechanism. Its high content of organic groups leads to high retention properties. Column efficiencies of 170 000 plates/m were measured for this 80% vinyltrimethoxysilane hybrid silica monolith. Long capillary monolithic columns (90 cm) were successfully synthesized (N = 120 000).  相似文献   

8.
We report an experimental study on the structural (especially radial) heterogeneity of eleven 100 μm i.d. capillary tetramethoxysilane-methyltrimethoxysilane hybrid silica monoliths with different pore and skeleton sizes, which were imaged by an optimized confocal laser scanning microscopy method. This method allows the optical sectioning of the monoliths, which is a prerequisite for quantitative morphological image analysis. Both radial porosity profiles and chord length distributions were calculated in the macropore domain for each column from at least 100 complete cross-sectional views along the column axis. The statistical approach visualized radial heterogeneities on different length scales in the monolithic structures. Chord length distributions followed a simplified k-gamma function, and a structural parameter obtained from this function is introduced to provide a scalar measure of column heterogeneity. It enables the comparison of monoliths with different pore sizes and helps to establish correlations between the microscopic properties of a column, eddy dispersion, and its separation efficiency.  相似文献   

9.
A chloropropyl-functionalized silica (CP-silica) hybrid monolithic column was synthesized within the confines of a capillary via the sol–gel process using tetramethoxysilane (TMOS) and (3-chloropropyl)-trimethoxysilane (CPTMS) as the precursors. The resulting CP-silica hybrid monolith inside the capillary showed homogeneous macroporous morphology and was well attached to the inner wall of the capillary. The obtained CP-silica hybrid monolithic capillary column demonstrated the inherent hydrophobic property and could be applied as a reversed-phase stationary phase in CEC directly. Due to the great chemical reactivity of the incorporated chloro groups on the hybrid silica monolithic matrix, the chloropropyl moieties on the surface of the hybrid silica monolith matrix could be conveniently further modified by a tertiary amine of N,N-dimethyl-N-dodecylamine (DMDA) via the nucleophilic substitution reaction at 70 °C to introduce a dodecyl groups (C12) onto the CP-silica hybrid monolithic matrix. The resulting C12-silica hybrid monolithic column not only demonstrated the significantly enhanced hydrophobic property in the separation of alkylbenzenes in reversed-phase capillary electrochromatography (RP-CEC), but also the strong electroosmotic flow (EOF) in a wide pH range. Five alkylbenzenes could be baseline separated in 3 min with column efficiency ranging from 189 700 to 221 000 N/m with a 70% ACN running buffer in CEC.  相似文献   

10.
A simple approach to fabricate hybrid monolithic column within the confines of fused-silica capillaries (75 μm i.d.) was introduced. A polyhedral oligomeric silsesquioxanes (POSS) reagent containing a methacrylate group was selected as functional monomer, and copolymerized with bisphenol A dimethacrylate (BPADMA) or ethylene dimethacrylate (EDMA) in the presence of porogenic solvents via thermally initiated free radical polymerization. After optimization of the preparation conditions, two POSS-containing hybrid monoliths were successfully prepared and exhibited good permeability and stability. By comparison of the separation efficiencies of the resulting poly(POSS-co-BPADMA) and poly(POSS-co-EDMA) monoliths in capillary electrochromatography (CEC) and capillary liquid chromatography (cLC), it was indicated the former has better column efficiencies for alkylbenzenes, phenols, anilines and PAHs in CEC and cLC than the latter. Particularly, the hybrid poly(POSS-co-BPADMA) monolith is more suitable for separation of PAHs due to π–π interaction between the analytes and aromatic rings in the surface of monolithic stationary phase.  相似文献   

11.
Monolithic capillary columns with surface bound lectin affinity ligands were introduced for performing lectin affinity chromatography (LAC) by nano-liquid chromatography (nano-LC). Two kinds of polymethacrylate monoliths were prepared, namely poly(glycidyl methacrylateco-ethylene dimethacrylate) and poly(glycidyl methacrylate-co-ethylene dimethacrylate-co-[2-(methacryloyloxy)ethyl]trimethyl ammonium chloride) to yield neutral and cationic macroporous polymer, respectively. Two lectins including concanavalin (Con A) and wheat germ agglutinin (WGA) were immobilized onto the monolithic capillary columns. The neutral monoliths with immobilized lectins exhibited lower permeability under pressure driven flow than the cationic monoliths indicating that the latter had wider flow-through pores than the former. Both types of monoliths with immobilized lectins exhibited strong affinity toward particular glycoproteins and their oligosaccharide chains (i.e., glycans) having sugar sequences recognizable by the lectin. Due to the strong binding affinity, the monoliths with surface bound lectins allowed the injection of relatively large volume (i.e., several column volumes) of dilute samples of glycoproteins and glycans thus allowing the concentration of the glycoconjugates and their subsequent isolation and detection at low levels (approximately 10(-8) M). To further exploit the lectin monoliths in the isolation of glycoconjugates, two-dimensional separation schemes involving LAC in the first dimension and reversed-phase nano-LC in the second dimension were introduced. The various interrelated methods established in this investigation are expected to play a major role in advancing the sciences of "nano-glycomics".  相似文献   

12.
Liu Z  Otsuka K  Terabe S  Motokawa M  Tanaka N 《Electrophoresis》2002,23(17):2973-2981
The physical adsorption method proposed previously has been successfully applied to a monolithic silica column. By virtue of the physical adsorption, a chiral stationary phase of avidin was prepared onto the silica monolith. The phase ratio of resulting stationary phase was evaluated with frontal analysis. The method proved to be comparable in phase ratio to the chemical bonding methods used in high-performance liquid chromatography (HPLC). Enantiomer separations were carried out in capillary electrochromatography (CEC) and capillary liquid chromatography (CLC) modes. Due to its larger phase ratio, the resulting column showed more powerful separation capability as compared to open-tubular CEC (OTCEC). Twelve chiral compounds were baseline-resolved. The resulting column showed high separation efficiency, with average theoretical plate numbers of 66 000/m for CLC and 122 000/m for CEC. Good reproducibility was observed, with RSD value less than 1.3% for retention time, retention factor and separation factor, and less than 6.6% for plate counts and resolution (n = 40). Fast separations were achieved with a short column. The test enantiomers were baseline-resolved within 4 min under CLC and CEC modes. In addition, field-enhanced sample injection (FESI) was coupled to CLC as well as CEC to improve the detection sensitivity.  相似文献   

13.
A novel porous polymer monolith was prepared in situ in a fused-silica capillary using photoinitiated polymerization. Bisphenol A dimethacrylate (BPADMA) was selected as a crosslinker, copolymerized with benzyl methacrylate (BMA) in the presence of a binary porogenic solvent consisting of cyclohexanol and 1-decanol in ≤10 min. The resulting poly(BMA-co-BPADMA) monoliths exhibited good permeability and mechanical stability. Mixtures of alkylbenzenes, polycyclic aromatic hydrocarbons (PAHs) or phenolic compounds were successfully separated by CEC. A similar monolith was also prepared with ethylene dimethacrylate (EDMA) as the crosslinker instead of BPADMA to compare the separation ability of the resulting monoliths. The results indicated that poly(BMA-co-BPADMA) monoliths have better selectivity for aromatic analytes and greater chromatographic stability in higher aqueous mobile phase.  相似文献   

14.
翁中亚  薛芸  施文君  王彦  阎超 《色谱》2016,34(5):467-472
以丙烯酰胺(AM)为单体,八乙烯基倍半硅氧烷(POSS)为交联剂,偶氮二异丁腈(AIBN)为引发剂,四氢呋喃(THF)为致孔剂,通过原位聚合法制备了poly(POSS-co-AM)有机-无机杂化整体柱,并对各反应物的配比进行了优化。结果表明,当功能单体与致孔剂、POSS与AM的质量比均为1.0: 5.0, AIBN的质量分数为0.1%时,杂化整体柱的柱效最高。无机材料的引入使整体柱结构均匀并具有良好的渗透性,该整体柱既能用于亲水色谱模式,也能用于反相色谱模式。将制备的整体柱用于毛细管液相色谱和加压毛细管电色谱分离核苷类、胺类、硝基苯胺类等化合物,获得了良好的效果。  相似文献   

15.
Okanda FM  El Rassi Z 《Electrophoresis》2006,27(5-6):1020-1030
In this report, microcolumn separation schemes involving monolithic capillary columns with immobilized lectins, and relevant to nanoglycomics/nanoproteomics were introduced. Positive and neutral monoliths based on poly(glycidyl methacrylate-co-ethylene dimethacrylate) were designed for achieving lectin affinity chromatography (LAC) by nano-LC and CEC. The positive monoliths (i.e., monoliths with cationic sites) afforded relatively high permeability in nano-LC but lack predictable EOF magnitude and direction, while neutral monoliths provided a good compromise between reasonable permeability in nano-LC and predictable EOF in CEC. Lectin affinity nano-LC permitted the enrichment of classes of different glycoproteins having similar N-glycans recognized by the immobilized lectin, whereas lectin affinity CEC provided the simultaneous capturing and separation of different glycoproteins due to differences in charge-to-mass ratio. Also, this investigation demonstrated for the first time the coupling of lectin capillary columns in series (i.e., tandem columns) for enhanced separation of glycoproteins by LAC using the CEC modality. Furthermore, in the coupled columns format, glycoforms of a given glycoprotein were readily separated.  相似文献   

16.
Macroporous monolithic poly(butyl methacrylate-co-ethylene dimethacrylate) stationary phases were synthesized in the confines of 100 μm I.D. fused-silica capillaries via a free radical copolymerization of mono and divinyl monomeric precursors in the presence of porogenic diluents. These columns were used in order to determine their suitability for the reversed-phase separation of small molecules in isocratic nano-LC mode. Carefully designed experiments at varying realized phase ratio by a terminated polymerization reaction, as well as content of organic modifier in the mobile phase, address the most significant parameters affecting the isocratic performance of these monoliths in the separation of small molecules. We show that the performance of methacrylate-based porous polymer monoliths is strongly affected by the retention factor of the analytes separated. A study of the porous and hydrodynamic properties reveals that the actual nature of the partition and adsorption of the small analyte molecules between mobile and stationary (solvated) polymer phases are most crucial for their performance. This is due to a significant gel porosity of the polymeric stationary phase. The gel porosity reflects stagnant mass transfer zones restricting their applicability in the separation of small molecules under conditions of strong retention.  相似文献   

17.
Qu Q  Lu X  Huang X  Hu X  Zhang Y  Yan C 《Electrophoresis》2006,27(20):3981-3987
Nonporous silica spheres (1 microm) were synthesized and bonded with octadecylsilane functionality. These stationary phase particles were packed electrokinetically into fused-silica capillaries with 100 microm id for a length of 20 cm, which was evaluated by using pressurized CEC (pCEC). The efficiency of the C18 RP column was characterized through the theoretical plates of thiourea, benzyl alcohol, toluene, styrene, and naphthalene. The effects of experimental parameters such as the applied voltage, sample size, pump flow rate, pH value and the concentration of the buffer solution, and the content of methanol in the mobile phase, on-column efficiency were evaluated. Column efficiency as high as 200 000 theoretical plates per meter for naphthalene was obtained with the optimal condition of 70% v/v methanol and 30% v/v of 10 mmol/L phosphate buffer (pH 7.8) at an applied voltage of 10 kV and a supplementary pressure of 500 psi.  相似文献   

18.
We prepared different photopolymerized sol-gel (PSG) columns by varying the amount of monomer (methacryloxypropyltrimethoxysilane), porogen (toluene) and catalyst (hydrochloric acid) in the reaction solution containing a photoinitiator (Irgacure 1800). The effects of these variations on the chromatographic behavior of the PSG columns were studied. All of the columns studied exhibited reversed-phase character. The concentration of hydrochloric acid was important for the rigidity of the columns, although it did not affect the separation property. The ratio of monomer solution to porogen was a critical factor in controlling the through-pore size and the surface area of PSG, which were found to significantly affect the separation properties, such as permeability, theoretical plate number, retention time, and separation efficiency, of a mixture of test analytes-thiourea, benzene, and naphthalene. There was no change in the retention order for the test analytes. Short separation times were achieved on PSG columns made from a 10% monomer stock solution and 90% porogen with 1 M hydrochloric acid. Mixtures of polycyclic aromatic hydrocarbons and alkylbenzenes were separated with theoretical plate numbers greater than 100 000 plates/m.  相似文献   

19.
Polymeric methacrylate-based monoliths are evaluated in capillary electrochromatography (CEC) and pressurized capillary electrochromatography (p-CEC) for their potential in pharmaceutical analysis. Using a given polymerization mixture as a basis for the monolith synthesis, different mobile phase pH at constant organic modifier concentrations are tested in both CEC and p-CEC. The test set consists of basic, acidic, amphoteric, and neutral compounds, which are mainly pharmaceuticals. Because of the mainly hydrophobic character of the stationary phase, the interactions are largest when the compounds appear in an uncharged state, but some ion-exchange phenomena with negatively charged compounds can also be observed. In CEC, acidic substances are most retained at low pH. For amphoteric and neutral compounds, no preference regarding analyzing pH can be derived from these experiments. For basics, a high pH is chosen, but a reduced solvent strength is needed to enhance the retention of these compounds. The retention mechanism in p-CEC can also be assigned to both hydrophobic and ionic interactions. For acidic, amphoteric, and neutral compounds, acceptable retention is seen. For the basic compounds, the retention with a mobile phase containing 50% organic modifier is low, as in CEC. However, when the organic modifier content in the mobile phase is decreased, retention increases and the selectivity of the stationary phase is more pronounced. This mode of operation presents a possibility for separating some test mixtures, thus some potential for pharmaceutical analysis is seen. More efforts are needed to obtain higher efficiencies and better peak shapes, which might be solved by a further optimization of both the stationary phase synthesis and the mobile phase composition.  相似文献   

20.
Shi ZG  Feng YQ  Xu L  Zhang M  Da SL 《Talanta》2004,63(3):593-598
Silica monoliths were fabricated inside fused-silica capillaries. Then the monolithic columns were coated with membrane-like zirconia. The zirconia-coated silica monoliths exhibited different EOF behavior comparing with that of bare silica monoliths. The magnitude and direction could be manipulated by changing the running buffers. Due to the amphoteric characteristic of zirconia, the silica monoliths with zirconia surface facilitate the separation of basic compounds. Aromatic amines and alkaloids were separated without obvious peak tailing. The zirconia surface was easily modified with octadecylphosphonic acid for the separation of neutral compounds. Column efficiency as high as 90,000 and 80,000 m−1 was obtained for beberine and naphthalene, respectively. Furthermore, the zirconia coating increased the stability of the monolithic columns. Even after being exposed to severe condition, there was no apparently efficiency decrease for the test samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号