首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Several modifications of a previously described protocol are proposed to improve the performances of in-situ synthesized C8 hybrid silica monoliths. Our attention was focused on reducing the sources of radial heterogeneity that may be responsible for the poor efficiencies observed in the hydrodynamic elution mode. It was demonstrated that a decrease in the temperature of the capillary during the filling step equally to that of the polymerization mixture (0 °C), associated with a decrease of the gelation temperature to 20 °C along with a new pre-treatment of the capillary's internal walls [with a mixture of tetraethoxysilane (TEOS)/EtOH (1/3, v/v)] allows (i) increasing the radial homogeneity of the monolith, thus further enhancing the performances in the nano-liquid chromatography (nano-LC) mode, (ii) improving the capillary to capillary reproducibility in terms of permeability and efficiencies. In fact, the average minimum plate height Hmin was lowered from 24 to 14 μm and the capillary-to-capillary reproducibility of the synthesis was widely improved by factors two and three of reduction on the calculated standard deviation, respectively for both the efficiency in the nano-LC mode and the permeability. At last, the improved radial homogeneity and anchoring of the synthesized monoliths allowed increasing the inner diameter of the capillary (up to 150 μm) without any significant loss in efficiency. Finally, long term stability of the as-obtained monolithic stationary phases in terms of retention and efficiency was studied. In addition, the evaluation of their chromatographic behaviour was also achieved with the Tanaka test and the results were compared to those already published for commercial monoliths (Chromolith) as well as for particulate stationary phases.  相似文献   

2.
In the last decade, silica monolithic capillaries have focused more and more attention on miniaturized separation techniques like capillary electrochromatography (CEC), nano-liquid chromatography (nano-LC) and chip electrochromatography owing to their unique chromatographic properties and their simplified preparation compared with packed columns. They are synthesized according to a sol-gel multi-step process that includes, after a gelation step at 40 degrees C leading to the formation of the macropores network and the silica skeleton, a post-gelation step (hydrothermal treatment at 120 degrees C in basic medium) that allows to tailor the mesopores and finally a calcination or a washing step to remove remaining polymers. In order to reduce the synthesis time, the number of synthesis steps and above all the temperature synthesis, to adapt the synthesis of such silica monoliths in polymeric microsystem devices, we extensively studied the influence of the hydrothermal treatment and its duration on textural (pore size distribution) and chromatographic properties (retention, efficiency) of in situ-synthesized capillary monoliths in nano-LC and CEC. This study was performed on pure silica and octyl chains grafted silica monoliths. Untreated monoliths show small pores (<6 nm), whereas hydrothermally treated monoliths exhibit medium and large mesopores (8-17 nm). It was demonstrated that the hydrothermal treatment at 120 degrees C was not necessary for pure silica monolithic capillaries dedicated to normal phase liquid chromatography or hydrophilic interaction liquid chromatography (HILIC) and electrochromatography: the suppression of the hydrothermal treatment did not impair efficiencies in CEC and in nano-LC but contributed to increase in retention factors. Minimal plate heights of ca. 5 microm in CEC and 6 microm in nano-LC were obtained with or without hydrothermal treatment with bare silica. In the same way, the hydrothermal treatment was not necessary for grafted silica monoliths only dedicated to CEC. However, the results clearly indicate that the hydrothermal treatment becomes essential before grafting in order to preserve the efficiency of the monolithic silica capillaries dedicated to nano-LC: in this particular case, the suppression of the hydrothermal treatment leads approximately to a loss of a factor two in efficiency.  相似文献   

3.
During the last decade, silica monolithic capillaries have focused more and more attention on miniaturized separation techniques like CEC, nano-LC, and chip electrochromatography owing to their unique chromatographic properties and to their possible in situ synthesis. Nevertheless, the preparation of conventional silica-based individual monolithic columns is time consuming, owing to the individual steps involved, including the synthesis of the silica matrix and its subsequent on-column chemical grafting. The hybrid organic-inorganic monoliths, whose synthesis is based on the polycondensation of siloxane with organosiloxane precursors, seems to be an attractive alternative since their direct synthesis leads to silica monoliths with organic moieties covalently linked to the inorganic silica matrix through hydrolytically stable Si-C bonds. This study describes the synthesis of hybrid monoliths using propyltrimethoxysilane (C3-TriMOS) as a new kind of silica coprecursor to subsequently increase the hydrophobicity of the stationary phase. The influence of several experimental parameters (pH, gelation temperature, relative proportion of the precursors) on the textural (skeleton and macropore size) and chromatographic properties (efficiency, retention, and electroosmotic mobility) of the obtained monoliths are discussed. The results show that the optimal coprecursor incorporation is obtained after a postgelation step during which the condensation of the C3-TriMOS coprecursor is favored by an increase in the pH medium. Thermal hydrolysis of urea previously added to the polymerization mixture allows this in situ pH increase. These hybrid monoliths present hydrophobic properties and allow the separation of test mixtures in the RP mode without any further modification. Moreover, they present excellent efficiencies since reduced plate height as low as 5 and 15 microm are obtained in the electrodriven mode (CEC) and in the hydrodynamic one (nano-LC), respectively.  相似文献   

4.
In this study, metal organic framework (MOF)–organic polymer monoliths prepared via a 5-min microwave-assisted polymerization of ethylene dimethacrylate (EDMA), butyl methacrylate (BMA), and 2-acrylamido-2-methylpropane sulfonic acid (AMPS) with the addition of various weight percentages (30–60%) of porous MOF (MIL-101(Cr)) were developed as stationary phases for capillary electrochromatography (CEC) and nano-liquid chromatography (nano-LC). Powder X-ray diffraction (PXRD) patterns and nitrogen adsorption/desorption isotherms of these MOF–organic polymer monoliths showed the presence of the inherent characteristic peaks and the nano-sized pores of MIL-101(Cr), which confirmed an unaltered crystalline MIL-101(Cr) skeleton after synthesis; while energy dispersive spectrometer (EDS) and micro-FT-IR spectra suggested homogenous distribution of MIL-101(Cr) in the MIL-101(Cr)–poly(BMA–EDMA) monoliths. This hybrid MOF–polymer column demonstrated high permeability, with almost 800-fold increase compared to MOF packed column, and efficient separation of various analytes (xylene, chlorotoluene, cymene, aromatic acids, polycyclic aromatic hydrocarbons and trypsin digested BSA peptides) either in CEC or nano-LC. This work demonstrated high potentials for MOF–organic polymer monolith as stationary phase in miniaturized chromatography for the first time.  相似文献   

5.
6.
A silica-based monolithic stationary phase prepared by the sol-gel process in a 100 microm I.D. fused-silica (FS) capillary has been modified chemically with 3-mercaptopropyl trimethoxysilane followed by immobilization of a strong cation-exchange (SCX) type chiral selector, (S)-N-(4-allyloxy-3,5-dichlorobenzoyl)-2-amino-3,3-dimethylbutane phosphonic acid, by radical addition reaction onto the reactive sulfhydryl surface. After a fine-tuning of the mobile phase composition, the enantioselective capillary column was evaluated for the separation of various chiral basic drugs by enantioselective non-aqueous capillary electrochromatography (CEC), in comparison to capillary column analogs packed with 3.5 microm silica particles having attached the same selector. The performance of the monolithic silica column was further compared to corresponding polymethacrylate-based organic polymer monoliths. The study indicated that strong counter-ions such as 2-aminobutanol or N,N,N',N'-tetramethylethylenediamine are needed, although they reduce the electroosmotic flow velocity and separation factors in comparison to less efficient counter-ions, in order to allow the elution of the oppositely charged solutes in the ion-exchange retention mode within reasonable run time and as sharp zones. In contrast, weak counter-ions such as N,N-diisopropylethylamine (Huenig base) provided stronger electroosmotic flow and much better separation factors, but relatively poor peak efficiencies. Overall, with the chemically functionalized monolithic silica column the high quality separations of packed column analogs could be approximated, with regards to both separation factors and peak performances. On the other hand, the monolithic capillary column certainly outperformed the packed column in terms of system robustness under capillary electrochromatography conditions and showed excellent column longevity. The enantioselective strong cation-exchange-type monolithic silica column performed also well in comparison to the organic polymer monolith.  相似文献   

7.
A novel organic‐silica hybrid monolith was prepared through the binding of histidine onto the surface of monolithic matrix for mixed‐mode per aqueous and ion‐exchange capillary electrochromatography. The imidazolium and amino groups on the surface of the monolithic stationary phase were used to generate an anodic electro‐osmotic flow as well as to provide electrostatic interaction sites for the charged compounds at low pH. Typical per aqueous chromatographic behavior was observed in water‐rich mobile phases. Various polar and hydrophilic analytes were selected to evaluate the characteristics and chromatographic performance of the obtained monolith. Under per aqueous conditions, the mixed‐mode mechanism of hydrophobic and ion‐exchange interactions was observed and the resultant monolithic column proved to be very versatile for the efficient separations of these polar and hydrophilic compounds (including amides, nucleosides and nucleotide bases, benzoic acid derivatives, and amino acids) in highly aqueous mobile phases. The successful applications suggested that the histidine‐modified organic‐silica hybrid monolithic column could offer a wide range of retention behaviors and flexible selectivities toward polar and hydrophilic compounds.  相似文献   

8.
Amylose tris(5-chloro-2-methylphenylcarbamate) was coated onto native and aminopropylsilanized silica in order to prepare chiral stationary phases (CSP) for enantioseparations using nano-liquid chromatography (nano-LC) and capillary electrochromatography (CEC). The effect of the nature of silica, the particle size and pore diameter, the chiral selector loading onto silica, the mobile phase composition and pH, as well as separation variables such as a linear flow rate of the mobile phase, applied voltage in CEC, etc. on the separation of enantiomers was studied. It was found that CSPs based on amylose tris(5-chloro-2-methylphenylcarbamate) can be used for preparation of stable capillary columns for enantioseparations by nano-LC and CEC in combination with polar organic and aqueous–organic mobile phases. Higher peak efficiency was observed in CEC than in nano-LC.  相似文献   

9.
A new feature of hydrophobic fumed silica nanoparticles (HFSNPs) when they apply to the preparation of monolithic nano-columns using narrow monolithic fused silica capillary columns (e.g., 50-µm inner diameter) was presented. The monolithic nano-columns were synthesized by an in-situ polymerization using butyl methacrylate (BMA) and ethylene dimethacrylate (EDMA) at various concentrations of AEROSIL®R972, called HFSNPs. Dimethyl formamide (DMF) and water were used as the porogenic solvents. These columns (referred to as HFSNP monoliths) were successfully characterized by using scanning electron microscopy (SEM) and reversed-phase nano-LC using alkylbenzenes and polyaromatic hydrocarbons as solute probes. The reproducibility values based on run-to-run, column-to-column and batch-to-batch were found as 2.3%, 2.48% and 2.99% (n = 3), respectively. The optimized column also indicated promising hydrophobic interactions under reversed-phase conditions, while the feasibility of the column allowed high efficiency and high throughput nano-LC separations. The potential of the final HFSNP monolith in relation to intact protein separation was successfully demonstrated using six intact proteins, including ribonuclease A, cytochrome C, carbonic anhydrase isozyme II, lysozyme, myoglobin, and α-chymotrypsinogen A in nano-LC. The results showed that HFSNP-based monolithic nanocolumns are promising materials and are powerful tools for sensitive separations.  相似文献   

10.
Ou J  Zhang Z  Lin H  Dong J  Wu M  Zou H 《Electrophoresis》2012,33(11):1660-1668
Hydrophobic organic-inorganic hybrid monolithic columns were synthesized via thermally initiated free radical polymerization with the confines of 75 μm id capillary using a polyhedral oligomeric silsesquioxane (POSS) reagent containing eight or more methacrylate groups as the crosslinker. Three organic functional monomers, butyl methacrylate (BuMA), lauryl methacrylate (LMA) and methacrylic acid (MAA), were selected and copolymerized with the POSS in the presence of 1-propanol and 1,4-butanediol to prepare the poly(POSS-co-BuMA), poly(POSS-co-LMA), and poly(POSS-co-MAA) monoliths, respectively. The 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) was copolymerized as ionizable monomer into the poly(POSS-co-BuMA) and poly(POSS-co-LMA) for the generation of EOF in capillary electrochromatography (CEC). A hybrid poly(POSS-co-LMA-co-MAA) monolith was also similarly prepared by copolymerizing ternary monomers of POSS, LMA, and MAA, and compared with poly(POSS-co-BuMA), poly(POSS-co-LMA), and poly(POSS-co-MAA) monoliths. The resulting four kinds of POSS-contained hybrid monoliths exhibited good permeability and mechanical stability. Their column efficiencies were evaluated by the separation of alkylbenzene homologues and polar compounds in CEC. The results indicated that the highest efficiencies of 194,100 and 102,100 theoretical plates per meter for thiourea and benzene were obtained on the poly(POSS-co-LMA-co-MAA) monolith. Additionally, the poly(POSS-co-LMA-co-MAA) monolith exhibited better selectivity for separation of polar compounds than those of other hybrid monoliths.  相似文献   

11.
Liu Y  Heyden YV  Mangelings D 《Electrophoresis》2012,33(11):1613-1623
Chiral monolithic silica capillary columns were prepared by immobilization of amylose-3,5-dimethylphenylcarbamate (ADMPC) bearing a small fraction of 3-(triethoxysilyl)propyl residues through intermolecular polycondensation of the triethoxysilyl groups. The obtained columns were used for chiral separations in capillary electrochromatography (CEC). The effects of the silica monolith nature and the used chiral selector concentration on the resulting enantiomeric separations were investigated. Fifteen chiral compounds, including acidic, neutral, and basic substances were evaluated and twelve showed partial or baseline separation at some of the different conditions tested. These results demonstrated the promising applicability of ADMPC-immobilized monolithic silica columns in CEC enantioseparations, but also revealed the need for further improvements on the level of baseline separations and efficiencies.  相似文献   

12.
We report a premier side-by-side comparison of two leading types of monolithic nano-LC column (silica-C(18), polystyrene) in shotgun proteomics experiments. Besides comparing the columns in terms of the number of peptides from a real-life sample (Arabidopsis thaliana chloroplast) that they identified, we compared the monoliths in terms of peak capacity and retention behavior for standard peptides. For proteomics applications where the mobile phase composition is constrained by electrospray ionization considerations (i.e., there is a restricted choice of ion-pairing modifiers), the polystyrene nano-LC column exhibited reduced identification power. The silica monolith column was superior in all measured values and compared very favorably with traditional packed columns. Finally, we investigated the performances of the monoliths at high flow rates in an attempt to demonstrate their advantages for high-throughput identification.  相似文献   

13.
A simple approach to fabricate hybrid monolithic column within the confines of fused-silica capillaries (75 μm i.d.) was introduced. A polyhedral oligomeric silsesquioxanes (POSS) reagent containing a methacrylate group was selected as functional monomer, and copolymerized with bisphenol A dimethacrylate (BPADMA) or ethylene dimethacrylate (EDMA) in the presence of porogenic solvents via thermally initiated free radical polymerization. After optimization of the preparation conditions, two POSS-containing hybrid monoliths were successfully prepared and exhibited good permeability and stability. By comparison of the separation efficiencies of the resulting poly(POSS-co-BPADMA) and poly(POSS-co-EDMA) monoliths in capillary electrochromatography (CEC) and capillary liquid chromatography (cLC), it was indicated the former has better column efficiencies for alkylbenzenes, phenols, anilines and PAHs in CEC and cLC than the latter. Particularly, the hybrid poly(POSS-co-BPADMA) monolith is more suitable for separation of PAHs due to π–π interaction between the analytes and aromatic rings in the surface of monolithic stationary phase.  相似文献   

14.
Huang G  Lian Q  Zeng W  Xie Z 《Electrophoresis》2008,29(18):3896-3904
A silica-based monolith as polar stationary phase was described for hydrophilic interaction pressurized capillary electrochromatography (HI-pCEC). The polar monolithic column was prepared by on-column reaction of lysine with epoxy groups on a gamma-glycidoxypropyltrimethosysilane-modified silica monolith. The stationary phase yielded strong hydrophilic interaction due to the slightly polar hydroxyl groups, and the strong polar lysine ligand with amino groups and carboxylic groups contained on the surface of the monolith. In order to evaluate the hydrophilic character of lysine ligand, the chromatographic behaviors of epoxy monolith (before lysine bonded) and diol monolith (hydroxyl groups contained) were also investigated. Two groups of comparative experiment were developed in terms of the separation of typical neutral non-polar and polar compounds performed in a mobile phase of aqueous-acetonitrile solution. Results showed that the lysine monolith was much more hydrophilic than the diol monolith, which presented less hydrophobic than the epoxy monolith. For further study on its hydrophilic character, the lysine monolith was demonstrated in the HI-pCEC mode for the separations of various polar compounds such as phenols, nucleic acid bases and nucleosides.  相似文献   

15.
A new reactive capillary monolith as an alternative to the commonly employed glycidyl methacrylate-based stationary phases in capillary electrochromatography (CEC) applications was synthesized and post-functionalized with charge-bearing groups. For this purpose, a hydrophilic capillary monolith with reactive 3-chloro-2-hydroxypropyl moiety was first obtained by the copolymerization of a new methacrylate-based monomer, 3-chloro-2-hydroxypropyl methacrylate (HPMA-Cl), with a methacrylic crosslinking agent, ethylene glycol dimethacrylate (EDMA). The presence of 3-chloro-2-hydroxypropyl functionality in poly(HPMA-Cl-co-EDMA) monolith allowed the synthesis of monoliths carrying strongly ionizable anionic, cationic or neutral groups such as sulfonic acid, quaternary ammonium or octadecyl, respectively, via simple and single-stage reactions. In the present study, a reactive poly(HPMA-Cl-co-EDMA) capillary monolith was functionalized with sodium bisulfite (NaHSO3) to have a strongly ionizable sulfonic acid group on the monolith. The resulting monolith providing cathodic electroosmotic flow in CEC was successfully used for the separation of phenol derivatives. The theoretical plate numbers up to 63,000 plates/column were achieved. The results showed that a new promising, reactive support that could be functionalized with different chromatographic ligands for different chromatographic applications was obtained in the study.  相似文献   

16.
Zhu T  Row KH 《Journal of separation science》2012,35(10-11):1294-1302
This review presents an overview of the properties of hybrid organic-inorganic monolithic materials and summarizes the recent developments in the preparation and applications of these hybrid monolithic materials. Hybrid monolithic materials with porosities, surface functionalities, and fast dynamic transport have developed rapidly, and have been used in a wide range of applications owing to the low cost, good stability, and excellent performance. Basically, these materials can be divided into two major types according to the chemical composition: hybrid silica-based monolith (HSM) and hybrid polymer-based monolith (HPM). Compared to the HPM, HSM monolith has been attracting most wide attentions, and it is commonly synthesized by the sol-gel process. The conventional preparation procedures of two type's hybrid organic-inorganic monoliths are addressed. Applications of hybrid organic-inorganic monoliths in optical devices, capillary microextraction (CME), capillary electrochromatography (CEC), high performance liquid chromatography (HPLC), and chiral separation are also reviewed.  相似文献   

17.
Monolithic capillary columns were prepared via ring-opening metathesis polymerization (ROMP) using norborn-2-ene (NBE) and 1, 4, 4a, 5, 8, 8a-hexahydro-1, 4, 5, 8-exo,endo-dimethanonaphthalene (DMN-H6) as monomers. The monolithic polymer was copolymerized with Grubbs-type initiator RuCl(2)(PCy(3))(2)(CHPh) and a suitable porogenic system within the confines of fused silica capillaries of different inner diameter (I.D.). The first part of the study focused on batch-to-batch reproducibility of ROMP-derived capillary monoliths. Capillary monoliths of 200 microm I.D. showed good reproducibility in terms of retention times, with relative standard deviations (RSD) of 1.9% for proteins and 2.2% for peptides. However, the separately synthesized capillary monoliths revealed pronounced variation in back pressure with RSD values of up to 31%. These variations were considerably reduced by cooling of the capillaries during polymerization. Using this optimized preparation procedure capillary monoliths of 100 and 50 microm I.D. were synthesized and the effects of scaling down the column I.D. on the morphology and on the reproducibility of the polymerization process were investigated. In the second part, the applicability of ROMP-derived capillary monoliths to a separation problem common in medical research was assessed. A 200 microm I.D. monolithic column demonstrated excellent separation behavior for insulin and various insulin analogs, showing equivalent separation performance to Vydac C4 and Zorbax C3-based stationary phases. Moreover, the high permeability of monoliths enabled chromatographic separations at higher flow rates, which shortened analysis time to about one third. For the analysis of insulin in human biofluid samples, enhanced sensitivity was achieved by using a 50 microm I.D. ROMP-derived monolith.  相似文献   

18.
High-efficiency peptide analysis using multimode pressure-assisted capillary electrochromatography/capillary electrophoresis (pCEC/pCE) monolithic polymeric columns and the separation of model peptide mixtures and protein digests by isocratic and gradient elution under an applied electric field with UV and electrospray ionization-mass spectrometry (ESI-MS) detection is demonstrated. Capillary multipurpose columns were prepared in silanized fused-silica capillaries of 50, 75, and 100 microm inner diameters by thermally induced in situ copolymerization of methacrylic monomers in the presence of n-propanol and formamide as porogens and azobisisobutyronitrile as initiator. N-Ethylbutylamine was used to modify the chromatographic surface of the monolith from neutral to cationic. Monolithic columns were termed as multipurpose or multimode columns because they showed mixed modes of separation mechanisms under different conditions. Anion-exchange separation ability in the liquid chromatography (LC) mode can be determined by the cationic chromatographic surface of the monolith. At acidic pH and high voltage across the column, the monolithic stationary phase provided conditions for predominantly capillary electrophoretic migration of peptides. At basic pH and electric field across the column, enhanced chromatographic retention of peptides on monolithic capillary column made CEC mechanisms of migration responsible for separation. The role of pressure, ionic strength, pH, and organic content of the mobile phase on chromatographic performance was investigated. High efficiencies (exceeding 300 000 plates/m) of the monolithic columns for peptide separations are shown using volatile and nonvolatile, acidic and basic buffers. Good reproducibility and robustness of isocratic and gradient elution pressure-assisted CEC/CE separations were achieved for both UV and ESI-MS detection. Manipulation of the electric field and gradient conditions allowed high-throughput analysis of complex peptide mixtures. A simple design of sheathless electrospray emitter provided effective and robust low dead volume interfacing of monolithic multimode columns with ESI-MS. Gradient elution pressure-assisted mixed-mode separation CE/CEC-ESI-MS mass fingerprinting and data-dependent pCE/pCEC-ESI-MS/MS analysis of a bovine serum albumin (BSA) tryptic digest in less than 5 min yielding high sequence coverage (73%) demonstrated the potential of the method.  相似文献   

19.
A pyridinium‐based immobilized ionic liquid type multifunctional hybrid silica monolith was prepared by the in situ polymerization of 3‐chloropropyl‐silica matrix and 4,4′‐dipyridyl for hydrophilic interaction CEC. The obtained hybrid monolith possessed of high stable skeletal microstructures with obviously hydrophilic retention mechanism under ACN content >50% in the mobile phase. Strong and stable anodic EOF could be observed under a broad pH range from pH 3.0 to 9.0. Due to the immobilized dipyridyl groups bonded to the silica matrix surface, the resulting hydrophilic hybrid monolith possessed multiple separation interactions including hydrogen bond, π–π, and anion exchange. Excellent separations of various polar analytes including electroneutral phenols, charged acid nucleotides, and basic analytes were successfully achieved. The highest column efficiencies up to 120 000, 164 000, and 106 000 plates/m were obtained for nucleotides, nucleic acid bases, and nucleosides and nicotines, respectively. These results demonstrated that the dipyridyl‐immobilized ionic liquid functionalized hybrid monolith possessed highly mechanical stability and good chromatographic performance for hydrophilic interaction electrochromatography.  相似文献   

20.
Silica monoliths coated with functionalised latex particles have been prepared for use in monolithic ion-exchange capillary electrochromatography (IE-CEC) for the separation of inorganic anions. The ion-exchange monoliths were prepared using 70 nm quaternary ammonium, anion-exchange latex particles, which were bound electrostatically to a monolithic silica skeleton synthesised in a fused silica capillary. The resulting stationary phases were characterised in terms of their chromatographic performance and capacity. The capacity of a 50 microm diameter 25 cm latex-coated silica monolith was found to be 0.342 nanoequivalents and 80,000 theoretical plates per column were typically achieved for weakly retained anions, with lower efficiency being observed for analytes exhibiting strong ion-exchange interaction with the stationary phase. The electroosmotic flow (EOF) was reversed after the latex-coating was applied (-25.96 m2 V(-1) s(-1), relative standard deviation (RSD) 2.8%) and resulted in anions being separated in the co-EOF mode. Ion-exchange interactions between the analytes and the stationary phase were manipulated by varying the ion-exchange selectivity coefficient and the concentration of a competing ion (phosphate or perchlorate) present in the electrolyte. Large concentrations of competing ion (greater than 1M phosphate or 200 mM perchlorate) were required to completely suppress ion-exchange interactions, which highlighted the significant retention effects that could be achieved using monolithic columns compared to open tubular columns, without the problems associated with particle-packed columns. The latex-coated silica monoliths were easily produced in bulk quantities and performed reproducibly in acidic electrolytes. The high permeability and beneficial phase ratio makes these columns ideal for micro-LC and preconcentration applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号