首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
With almost 20 years having passed since John B. Phillips described the first comprehensive two-dimensional gas chromatography (GC × GC) separation, much has occurred in this ever-expanding field of separation science. GC × GC is currently one of the most effective techniques for the separation and analysis of complex mixtures, offering significantly greater peak capacities than conventional chromatographic methods. The technique is generally based upon separations performed on two chromatographic columns characterized by considerably different selectivities, joined together through a modulating interface. The modulator periodically traps or samples the primary column effluent, usually refocuses it into a narrow chromatographic band and injects the focused fraction into the secondary column. The modulator is often referred to as the ‘heart’ of the instrument, since a GC × GC separation is impossible without its use. This article reviews major innovations in GC × GC modulator development since its first use by Phillips in 1991. Emphasis has been placed on modulator design and function.  相似文献   

2.
In this study, a new system for analysis using a dual comprehensive two-dimensional gas chromatography/targeted multidimensional gas chromatography (switchable GC × GC/targeted MDGC) analysis was developed. The configuration of this system not only permits the independent operation of GC, GC × GC and targeted MDGC analyses in separate analyses, but also allows the mode to be switched from GC × GC to targeted MDGC any number of times through a single analysis. By incorporating a Deans switch microfluidics transfer module prior to a cryotrapping device, the flow stream from the first dimension column can be directed to either one of two second dimension columns in a classical heart-cutting operation. Both second columns pass through the cryotrap to allow solute bands to be focused and then rapidly remobilized to the respective second columns. A short second column enables GC × GC operation, whilst a longer column is used for targeted MDGC. Validation of the system was performed using a standard mixture of compounds relevant to essential oil analysis, and then using compounds present at different abundances in lavender essential oil. Reproducibility of retention times and peak area responses demonstrated that there was negligible variation in the system over the course of multiple heart-cuts, and proved the reliable operation of the system. An application of the system to lavender oil, as a more complex sample, was carried out to affirm system feasibility, and demonstrate the ability of the system to target multiple components in the oil. The system was proposed to be useful for study of aroma-impact compounds where GC × GC can be incorporated with MDGC to permit precise identification of aroma-active compounds, where heart-cut multidimensional GC-olfactometry detection (MDGC-O) is a more appropriate technology for odour assessment.  相似文献   

3.
4.
Three commercially available chiral capillary columns, Chirasil-Dex, BGB-176SE, and BGB-172, have been evaluated for the separation into enantiomers of the 19 chiral polychlorinated biphenyls (PCB) congeners stable at room temperature. The enantiomers of 15 chiral PCBs were, at least to some extent, separated using these beta-cyclodextrin based columns. Multidimensional techniques, such as heart-cut multi-dimensional gas chromatography (heart-cut MDGC) and comprehensive two-dimensional gas chromatography (GC x GC), were investigated for their ability to solve coelution problems with other PCBs present in commercial mixtures and real-life samples. Heart-cut MDGC improved the separation as compared to one-dimensional GC, and enantiomeric fractions of the investigated chiral PCBs could be determined free from interferences. However, limitations on the number of target compounds that can be transferred to the second column in a single run and, therefore, the time consumption, have led to the evaluation of GC x GC as an alternative for this type of analysis. With GC x GC, two column set-ups were tested, both having a chiral column as first-dimension column, and two different polar stationary phase columns in the second dimension. On using both column combinations, congeners 84, 91, 95, 132, 135, 136, 149, 174, and 176 could be determined free from coelutions with other PCBs. Results on the application of heart-cut MDGC to food samples such as milk and cheese are given, as well as the first results on the application of GC x GC to this type of samples.  相似文献   

5.
Multidimensional gas chromatography (MDGC) is performed in a new manner, described in this paper. The method incorporates two directly coupled columns and employs a longitudinally modulated cryogenic trap located between the columns. No heartcutting process is used, but rather a method better termed selected zone compression pulsing is used. Compared with normal MDGC, where primary column effluent has to be temporarily diverted either to a monitor detector or to the second dimension column, the new procedure in its simplest mode passes all of the first column effluent to the second column. It is simply the times at which the modulation of the trap is performed that determines which target solutes will be selected for enhanced separation. This approach allows almost instantaneous separation of selected zones on the second column, and has the potential to significantly simplify the MDGC method. Since data are presented in a time-response format, and do not require transformation as previously described for comprehensive GC when using the longitudinal modulator, quantitation and report generation are essentially the same as in any GC method and data system. Advantages also include significant sensitivity improvement. By using cryofocussing, and benefiting from the zone compression effects along with fast GC conditions on the second dimension, new possibilities for MDGC can be realised. The method is demonstrated by using a mixture of semi-volatile aromatic hydrocarbons.  相似文献   

6.
Fatty acid methyl ester (FAME) profiling in complex fish oil and milk fat samples was studied using integrated comprehensive 2D GC (GC × GC) and multidimensional GC (MDGC). Using GC × GC, FAME compounds – cis‐ and trans‐isomers, and essential fatty acid isomers – ranging from C18 to C22 in fish oil and C18 in milk fat were clearly displayed in contour plot format according to structural properties and patterns, further identified based on authentic standards. Incompletely resolved regions were subjected to MDGC, with Cn (n = 18, 20) zones transferred to a 2D column. Elution behavior of C18 FAME on various 2D column phases (ionic liquids IL111, IL100, IL76, and modified PEG) was evaluated. Individual isolated Cn zones demonstrated about four‐fold increased peak capacities. The IL100 provided superior separation, good peak shape, and utilization of elution space. For milk fat‐derived FAME, the 2D chromatogram revealed at least three peaks corresponding to C18:1, more than six peaks for cis/trans‐C18:2 isomers, and two peaks for C18:3. More than 17 peaks were obtained for the C20 region of fish oil‐derived FAMEs using MDGC, compared with ten peaks using GC × GC. The MDGC strategy is useful for improved FAME isomer separation and confirmation.  相似文献   

7.
In comprehensive two-dimensional gas chromatography (GC×GC), two capillary columns are connected in series through an interface known as a “thermal modulator”. This device transforms effluent from the first capillary column into a series of sharp injection-like chemical pulses suitable for high-speed chromatography on the second column. Dramatic increases in the resolving power, sensitivity, and speed of the gas chromatograph result. This paper describes the development of a robust and reliable thermal modulator for GC×GC.  相似文献   

8.
Two approaches are described and compared for the analysis of suspected allergens (SAs) in fragrance products, which are defined by the Scientific Committee of Cosmetics and Non-Food Products (SCCNFP). The first consists of a comprehensive two-dimensional gas chromatography (GCxGC) experiment using both a "conventional" non-polar/polar column combination and an "inverse" polar/non-polar column set. The second approach uses a targeted multidimensional gas chromatography (MDGC) system employing a Deans type pneumatic switch and a longitudinally modulated cryogenic system (LMCS). It was found that the conventional and inverse column sets complement each other well, providing identification of SAs present. Compounds well retained on the second dimension of one column set were the first to be eluted from the other. In some instances SAs co-eluting with matrix components on the second dimension for a given column set were clearly resolved on the other, although this has the disadvantage of requiring two analytical runs. Targeted MDGC with a non-polar/polar column set, successfully separated all SAs identified within a fragrance product. The instrument is set up in a similar fashion to a GCxGC system though with longer second dimension ((2)D) column, a cryogenic trap at the beginning of the second column, and a pneumatic switch coupling both columns. The data are easier to process than for a GCxGC experiment. The targeted MDGC method has the capacity to deliver far greater efficiency to targeted regions of a primary separation than a GCxGC experiment, whilst still maintaining overall run times similar to those of a conventional one-dimensional (1D) GC experiment. Cryogenic focussing at the beginning of the (2)D column delivers enhanced sensitivity, accurate (2)D retention times and narrow peak widths; these are responsible for an increased resolution obtained from the fast, relatively short ( approximately 5m) (2)D column. The two column set GCxGC analysis provided a quick and effective means to qualitatively determine the presence of six SAs in a commercially available air freshener, however all were not adequately resolved from matrix components. In contrast, quantitation was straightforward using the targeted MDGC method.  相似文献   

9.
In gas chromatography (GC) reproducible retention times are in many cases highly favorable or in some cases even required. In one-dimensional GC, retention time shifts can be eliminated or minimized using a procedure called retention time locking (RTL). This procedure is based on adjusting the (constant) column head pressure. Unfortunately, this RTL procedure cannot be used in comprehensive two-dimensional gas chromatography (GC × GC) given the fact that peaks will shift in both dimensions. Adjusting the column head pressure in GC × GC will only minimize or eliminate the primary retention time shifts. In this paper, a fast and easy to perform, two-step retention time locking procedure for two-dimensional gas chromatography (2D-RTL) is proposed and its feasibility is demonstrated. This 2D-RTL procedure involves adjustment of the column head pressure or constant column flow, followed by the adjustment of the so-called effective secondary column length. The secondary column length is increased or decreased, simply by moving it stepwise through the modulator. It is demonstrated that retention time shifts in both the primary- and secondary-dimension, which may occur after e.g. replacing the column set, can be minimized to less than half peak base width. The proposed 2D-RTL procedure is used successfully for approximately 1 year in our laboratory.  相似文献   

10.
The writer of this review published in 1978 a three-part article on two-dimensional gas chromatography in the first three issues of this journal [1]. The review was written at a time when capillary column GC was still in its infancy. Commercial columns were (essentially) unavailable and sample introduction into capillary columns was done exclusively in the split mode. Two-dimensional separations were explored in only a few laboratories. The limitations of capillary column technology made this exercise rather difficult. The introduction of fused silica capillary columns in the early eighties drastically changed the landscape in which gas chromatography was practiced. It took the chromatographic community just a few years to convert from packed columns to capillary columns. Instrumentation and accessories specifically designed for capillary column use came onto the market. This writer had great hopes that the revolution in capillary column GC would be mirrored in the development of instrumentation for Two-Dimensional Gas Chromatography. This never materialized. On the contrary, tentative steps taken by a few manufacturers and suppliers of chromatographic equipment fizzled out. It was perhaps the introduction of relatively inexpensive and user friendly GC/MS instrumentation, in combination with nearly indestructible fused silica capillary columns that took away the incentive to develop commercially viable Two-Dimensional Gas Chromatography. Much of the thinking went like this: why insist on good chromatography if mass spectrometry can do the job without the need for complete separation. Some progress in the further development of conventional Two-Dimensional Gas Chromatography has certainly been made over the last 20 years but there has not been a great deal of excitement. Applications have also been relatively sparse and they are limited to just a few areas. Science does not remain static and chromatography is no exception. Progress in gas chromatography is driven by new technology and ideas. Substantial improvements in two-dimensional GC were not forthcoming until Phillips and his research group introduced and implemented an entirely new form of Two-Dimensional Gas Chromatography, called comprehensive two-dimensional GC, or GC×GC. This breakthrough occurred only in 1991 [2]. It does take some time before scientists change attitudes and habits. There is always a time lag between the introduction of new technology and its general acceptance. The public's attitude toward comprehensive Two-Dimensional Gas Chromatography is probably no exception. The number of scientists who are actively pursuing this new branch of gas chromatography is still very small. It is often a single individual who carries the torch. J.B. Phillips' name is synonymous with comprehensive Two-Dimensional Gas Chromatography. He is not only its inventor and proponent but his fertile mind has initiated research in other related areas. Sadly, he passed away shortly before this review was written. This contribution is dedicated to his memory.  相似文献   

11.
The present contribution is focused on the main advances made in the field of heart-cutting multidimensional gas chromatography (MDGC), over approximately the last decade. Brief details on the history of classical MDGC are also given. A series of applications, carried out with modern-day commercially available instrumentation are shown, demonstrating the usefulness of the bidimensional methodology in specific analytical situations. Finally, the future prospects of MDGC are considered, within the shadow projected by a very powerful GC technique, namely comprehensive two-dimensional gas chromatography.  相似文献   

12.
A high-temperature ionic liquid, trihexyl(tetradecyl)phosphonium bis(trifluoromethane)sulfonamide, was used as the primary column stationary phase for comprehensive two-dimensional gas chromatography (GC × GC). The ionic liquid (IL) column was coupled to a 5% diphenyl/95% dimethyl polysiloxane (HP-5) secondary column. The retention characteristics of the IL column were compared to polyethylene glycol (DB-Wax) and 50% phenyl/50% methyl polysiloxane (HP-50+). A series of homologous compounds that included hydrocarbons, oxygenated organics, and halogenated alkanes were analyzed with each column combination. This comparison showed that the ionic liquid is less polar than DB-Wax but more polar than HP-50+. The most unique feature of the IL × HP-5 column combination is that alkanes, cyclic alkanes, and alkenes eluted in a narrow band in the GC × GC chromatogram; whereas, these compounds occupied a much larger portion of the DB-Wax × HP-5 and the HP-50+ × HP-5 chromatograms. Each column combination was used to analyze diesel fuel. The IL × HP-5 chromatogram displayed narrow bands for three major compound classes in diesel fuel: saturates, monoaromatics, and diaromatics. The IL column was used at temperatures as high as 290 °C for several months without any noticeable changes in column performance.  相似文献   

13.
One of the major objectives in metabolomics is the identification of subtle changes in metabolite profiles as affected by genetic or environmental factors. Comprehensive two-dimensional gas chromatography (GC × GC) hyphenated to a fast-acquisition mass spectrometer is a well-established analytical technique to study the composition of complex samples due to its enhanced separation capacity, sensitivity, peak resolution, and reproducibility. This review reports applications of GC × GC to metabolomics studies of sample of different types (biofluid, cells, tissue, bacteria, yeast, plants), and discusses its advantages and limitations.  相似文献   

14.
Comprehensive two-dimensional gas chromatography (GC×GC) has been applied to the quantitative analysis of benzene, toluene, ethylbenzene, xylenes (BTEX), and all heavier aromatic compounds in gasoline. The two-dimensional chromatographic separation used volatility selection on the first-dimension column and polarity selection on the second-dimension column. In the resulting GC×GC chromatogram, aromatic species were resolved from other compound classes. Moreover, structurally related aromatics were grouped in a manner that facilitated identification and integration. The response of a flame ionization detector to each major aromatic group in gasoline was calibrated using internal standards. Quantitation produced results directly comparable with ASTM standard methods. The present GC×GC method can be expanded to analyze other gasoline components.  相似文献   

15.
字敏  张玉海  艾萍  袁黎明 《化学通报》2006,69(10):793-796
以纤维素三苯甲酸酯、纤维素三苯基氨基甲酸酯以及二者的混合物为固定相,制备了新型毛细管气相色谱柱,最高柱效达到2580板/米。其能对一些难分离物质对、位置异构体以及手性化合物进行拆分,如对丙氨酸的分离因子可达到1·13。此外,还研究了毛细管柱的极性、选择性以及保留机理。结果表明,该类聚合物是一类很有前景的新型气相色谱固定相。  相似文献   

16.
Comprehensive two-dimensional gas chromatography (GC x GC) is shown to provide information on dynamic molecular behaviour (interconversion), with the interconversion process occurring on both columns in the coupled-column experiment. The experiment requires suitable adjustment of both experimental conditions and relative dimensions of each of the columns. In this case, a longer column than normally employed in GC x GC allows sufficient retention duration on the second column, which permits the typical plateau-shape recognised for the interconversion process to be observed. The extent of interconversion depends on prevailing temperature, retention time, and the phase type. Polyethylene glycol-based phases were found to result in high interconversion kinetics, although terephthalic acid-terminated polyethylene glycol had a lesser extent of interconversion. Much less interconversion was seen for phenyl-methylpolysiloxane and cyclodextrin phases. This suggests that for the oximes, interconversion largely occurs in the stationary phase. Examples of different extents of interconversion in both dimensions are shown, including peak coalescence on the first column with little interconversion on the second column.  相似文献   

17.
A 2D liquid chromatography (LC) system using hydrophilic interaction chromatography (HILIC) and reversed phase columns has been employed for comprehensive (LC × LC) separation of rat muscle tissue micro-dialysate. Incorporation of an on-line reverse-phase solid phase extraction (SPE) enrichment column in front of the first dimension enabled aqueous samples with high salt concentrations to be injected directly without compromising the chromatographic performance of the HILIC column. Since the SPE enrichment column allowed injection of large sample volumes (e.g. 450 μL), a capillary HILIC column (inner diameter 0.3 mm) could be employed instead of a larger column which is often used in the first dimension to load sufficient amounts of sample. The two chromatographic dimensions were connected using a column selector system with 18, 1.0 mm I.D. C18 “transition” SPE columns. A PLRP C18 column was used in the second dimension. The 2D LC system’s performance was evaluated with a tryptic digest mixture of three model proteins. Good trapping accuracy (HILIC→transition SPE→RP recovery >95%) and repeatability (within-and between day retention time RSDs of first and second dimension chromatography >1%) was achieved. A dialysis sample of rat muscle tissue was separated with the 2D system, revealing complexity and large differences in concentrations of the various compounds present, factors which could potentially interfere with the quantification and monitoring of two target analytes, arg-bradykinin and bradykinin. Subsequently, “Heart-cut” 2D LC-electrospray–mass spectrometry (ESI–MS) with post-column on-line standard injection was employed to monitor arg-bradykinin and bradykinin levels as a function of various muscle conditions. The method’s quantification precision was RSD = 3.4% for bradykinin.  相似文献   

18.
气相色谱近年的发展   总被引:1,自引:0,他引:1  
傅若农 《色谱》2009,27(5):584-591
简要阐述了近几年气相色谱(GC)的发展和特点。GC是一个成熟的技术,广泛地应用于各个领域,近几年GC的发展除了继续研究新的固定相和高性能的毛细管色谱柱之外,主要在全二维气相色谱(GC×GC)、快速GC、便携式GC仪和微型GC仪几个方面。近几年新研究的GC固定相主要集中在常温离子液体和各种环糊精的衍生物。现在GC研究者趋向于使用商品化的GC毛细管柱,而商品化的GC毛细管柱应用最多的是以含5%苯基的聚甲基硅氧烷为固定相的色谱柱。GC×GC发展迅猛,特别是关于调制器的研究,已开发出十多种调制模式,并广泛地应用于各个领域。为了适应大量样品的分析和现场分析,研究和开发了多种快速GC方法和仪器以及便携式GC仪。为了仪器的小型化和专属性检测,μGC仪的研究也稳步地发展起来。  相似文献   

19.
A previously constructed semi-rotating cryogenic modulator was modified for comprehensive two-dimensional gas chromatography (GC×GC). The retention time repeatability was improved by replacing the modulator control program unit with a new system. Peak widths obtained with the modified modulator were comparable with those obtained with the previous modulator and other modulator types. The modulator was easy to construct and it can be installed in any commercial GC system. The constructed GC×GC–FID system and data obtained by gas chromatography–mass spectrometry (GC–MS) were used for identification of unknowns in forest aerosol samples. Figure A semi-rotating cryogenic modulator in which modulation is based on two-step cryogenic trapping with continuously flowing carbon dioxide has been developed for comprehensive two-dimensional gas chromatography  相似文献   

20.
A multiplexed dual-secondary column comprehensive two-dimensional gas chromatography approach (GC × 2GC) designed for complex sample analysis is introduced. The approach splits the first-dimension column effluent into two second-dimension columns with different stationary phases, and recombines the two streams into one detector post-separation. The approach produces two single two-dimensional chromatograms for each injection. Careful manipulation of thermal modulator timing parameters combined with a novel contra-directional modulation regime facilitates this approach. A selection of 34 laboratory reference compounds containing n-alkanes, alcohols, aromatic hydrocarbons, ketones, esters and halogenated hydrocarbons were analysed to demonstrate the approach. The dual two-dimensional chromatogram from this single detector system provides complementary information due to the unique selectivity of the three separation columns. The results of this proof-of-principle investigation provide significant impetus for further development of GC × 2GC–MS methodology.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号