1.
The applicability of the carbon paste electrode to the determination of trace quantities of mercury has been investigated in a base electrolyte of 0.1 N KSCN + 0.025 N HCl containing 25 ng/ml copper. The detection limit of the mercury determination has a value near 2.5 ng/ml (1.25×10?8 M), if pre-electrolysis is carried out 10 min at ?1.0 V and the current voltage curve is registered with a scan rate of 16.7 mV/sec between ?0.5 and +0.5 V. The peak height is directly proportional to the concentration in the range from 1.25×10?8 to 1.25×10?6 M. With appropriate preconditioning the carbon paste electrode can be used for several measurements without renewing the surface.  相似文献   

2.
Kim SI  Cha KW 《Talanta》2002,57(4):675-679
The determination of palladium(II) complexed with alpha-(2-benzimidazolyl)-alpha',alpha'-(N-5-nitro-2-pyridylhydrazone)-Toluene (BINPHT) was investigated by adsorptive cathodic stripping voltammetry using hanging mercury drop electrode. Palladium(II) in the sample solution can be determined in BINPHT and ethylenediaminetetraacetic acid (EDTA). Accumulation is achieved by adsorption of Pd(II)-BINPHT complex on a hanging mercury drop electrode. Optimal conditions were found to be: supporting electrolyte; 0.01 M sodium acetate buffer at pH 5.0, accumulation potential; -590 mV versus Ag/AgCl, accumulation time; 180 s, scan rate; 50 mV s(-1), concentration of BINPHT; 2x10(-5) M. The linear range of Pd(II) was observed over the concentration range 20-100 ng ml(-1) The detection limit (S/N=3) is 2 ng ml(-1). A good reproductivity shows RSD of 2.0% (n=7). This procedure offers high selectivity with the presence of EDTA masking some metallic ions. River water sample spiking with palladium was determined.  相似文献   

3.
A chemically modified carbon paste electrode was prepared by incorporating appropriate amounts of sodium humate(NaA). Palladium(II) was selectively accumulated in a solution of Britton-Robinson(B-R) buffer (pH 2.8) onto the electrode surface in open circuit mode. The subsequent electrochemical measurement was carried out by cyclic voltammetry (CV) and linear sweep anodic stripping voltammetry (LSASV) in a supporting electrolyte of 1.0 M HCl. The obtained oxidation currents (Ipa1 and Lpa2) were proportional to the Pd(II) concentration in the range of 4.7 × 10–6 - 9.4 × 10–8 M. The developed method was applied to the quantitative determination of palladium in real samples.  相似文献   

4.
A chemically modified carbon paste electrode was prepared by incorporating appropriate amounts of sodium humate(NaA). Palladium(II) was selectively accumulated in a solution of Britton-Robinson(B-R) buffer (pH 2.8) onto the electrode surface in open circuit mode. The subsequent electrochemical measurement was carried out by cyclic voltammetry (CV) and linear sweep anodic stripping voltammetry (LSASV) in a supporting electrolyte of 1.0 M HCl. The obtained oxidation currents (Ipa1 and Lpa2) were proportional to the Pd(II) concentration in the range of 4.7 × 10–6 - 9.4 × 10–8 M. The developed method was applied to the quantitative determination of palladium in real samples. Received: 6 March 1998 / Revised: 3 June 1998 / Accepted: 3 July 1998  相似文献   

5.
A flow-injection method is described for the measurement of acid and fluoride concentrations. The conditions were optimized to ensure small sample and reagent consumption, low detection limit and the highest rate of analysis allowed by the potentiometric sensor. With a microcapillary pH-sensitive glass electrode, 20-μl sample volumes and 1.0–1.5 ml min?1 carrier flow rates, strong acids were determined at concentrations as low as 10?5 M (0.2 nmol of acid in 20 μ1). The relative standard deviation was about 1% at 10?4 M strong acid concentration at an injection rate of 500–550 h?1. With a flow- through fluoride-selective electrode, 250-μl sample volumes and a 1 ml min?1 carrier flow rates, fluoride concentrations as low as 10?7 M were measured (ca. 0.5 ng of fluoride in 250 μ1). The injection rate was 40 h?1 at concentrations below 10?6 M, but 60 h?1 above 10?5 M. The methods were used successfully for determining the acid and fluoride concentrations in rain-waters.  相似文献   

6.
Cyclic voltammetry was used to investigate the electrochemical behaviour of ascorbic acid at a carbon—epoxy composite electrode modified with the electron mediator cobalt phthalocyanine. The modified electrode reduced the overpotential necessary for the oxidation of the vitamin by approximately 150 mV to 0.21 V vs. The saturated calomel electrode; the process was dependent on the pH of the supporting electrolyte, but independent of ionic strength over the range studied. The relative standard deviation (r.s.d.) of the peak heights of the cyclic voltammograms was 0.81% for a 1 × 10?4 M ascorbic acid solution (n = 7). The optimum supporting electrolyte was found to be 0.05 M phosphate buffer (pH 5).Amperometry in stirred solutions was then done at an applied potential of +0.25 V. The limit of detection was 0.65 ng ml?1 and the calibration graph was linear in the range 175 ng ml?1?50 μg ml?1. The method was used to determine ascorbic acid concentrations in single- and multivitamin preparations; the recovery was 97.86% for the vitamin added to one preparation. The r.s.d. for the analyses in these samples was about 5%. For comparison, the vitamin was also determined in these tablets using LC with UV detection at 254 nm; the correlation coefficient for the levels determined was 0.9989 (p = 0.0007).  相似文献   

7.
《Analytical letters》2012,45(9):1737-1748
Abstract

Isonitroso-4-methyl-2-pentanone (HIMP) is proposed as a new reagent for extraction and photometric determination of Pd(II). The reagent forms a yellow complex with palladium in the pH range 4.0-5.0. The complex extracted into chloroform was measured at 330 nm. The molar absorptivity was found to be 5.37 × 103 1 mol?1 cm?1 and Sandell's sensitivity 20 ng cm?2 Beer's law was obeyed over the concentration range 0.1-10.0 μg/ml of palladium. The method is applicable for palladium estimation in Ores and catalysts.  相似文献   

8.
Book reviews     
Inorganic mercury ions (Hg2+) in laboratory prepared solutions were determined with a screen-printed carbon electrode (SPCE) coated with a polyaniline-methylene blue (PANI-MB) polymer layer. The structure and properties of the PANI-MB polymer layer were compared to that of normal polyaniline (PANI) in order to elucidate the structure of the PANI-MB layer. The electrically-conducting polymers were prepared by electrochemical polymerisation of monomer solutions of aniline, and mixed solutions of aniline with methylene blue onto respective screen-printed carbon electrodes (SPCEs). Scanning Electron Microscopy (SEM) analyses of the SPCE polymer coated electrodes have shown that nanostructured materials have formed with the diameters of the PANI nanoclusters and PANI-MB nanorods at approximately 200 nm. Anodic stripping voltammetry (ASV) was used to evaluate a solution composed of 1 × 10?6 M Hg2+, in the presence of the SPCE/PANI-MB polymer sensor electrode. The Hg2+ ions were determined as follows: (i) pre-concentration and reduction on the modified electrode surface and (ii) subsequent stripping from the electrode surface during the positive potential sweep. The experimental conditions optimised for Hg2+ determination included the supporting electrolyte concentration and the accumulation time. The results obtained have shown that the SPCE/PANI-MB polymer sensor electrode operates optimally at a pH 2, with the supporting electrolyte concentration at 0.5 M HCl. A linear calibration curve was found to be in the range of 1 × 10?8 M to 1 × 10?5 M Hg2+ after 120 s of pre-concentration. The detection limit was calculated and found to be 54.27 ± 3.28 µg L?1 of Hg2+. The results have also shown that a conducting polymer modified SPCE sensor electrode can be used as an alternative transducer for the voltammetric stripping and analysis of inorganic Hg2+ ions.  相似文献   

9.
A differential pulse voltammetric (DPV) method is proposed for the determination of palladium in deoxo catalysts, which are used in recombination units of the cover gas system of nuclear reactors. The electrode system consists of hanging mercury drop electrode (HMDE)/ platinum auxillary/ Ag-AgCl reference electrode. The supporting electrolyte consists of 0.02 M diammonium tartrate + 0.08 M ammonia-ammonium chloride buffer at pH 9.0. Fe, Cu, Pb, Ni, Co and Zn did not interfere. The interference by Cd could be eliminated using 0.005 M EDTA. The relative standard deviation of the proposed method was about 4.0% at ∼ 0.5% palladium content in the catalyst. The method is simple, rapid and free from any possible interferences. Received: 8 December 1998 / Revised: 11 January 1999 / Accepted: 18 January 1999  相似文献   

10.
A differential pulse voltammetric (DPV) method is proposed for the determination of palladium in deoxo catalysts, which are used in recombination units of the cover gas system of nuclear reactors. The electrode system consists of hanging mercury drop electrode (HMDE)/ platinum auxillary/ Ag-AgCl reference electrode. The supporting electrolyte consists of 0.02 M diammonium tartrate + 0.08 M ammonia-ammonium chloride buffer at pH 9.0. Fe, Cu, Pb, Ni, Co and Zn did not interfere. The interference by Cd could be eliminated using 0.005 M EDTA. The relative standard deviation of the proposed method was about 4.0% at ~ 0.5% palladium content in the catalyst. The method is simple, rapid and free from any possible interferences.  相似文献   

11.
The reduction reaction of imidacloprid [1-(6-chloro-3-pyridylmethyl)-N-nitroimidazolidin-2-ylideneamine] at a mercury electrode shows two well-defined waves in the range of pH 2.0–11.0. The characteristics of the electrode processes were examined. The analyte captures four electrons in the first step and two in the second to give the hydroxylamine and amine derivatives, respectively. A differential-pulse polarographic method for the determination of imidacloprid based on the first reduction peak of this compound is presented. Britton-Robinson buffer was used as a supporting electrolyte and optimum pH value was found to be pH 8.O. The applicable concentration range was from 10 to 200 ng/ml, with a relative standard deviation of 1.5% (for a level of 80 ng/ml) and a detection limit of 3 ng/ml. The method has been satisfactorily applied to the determination of imidacloprid in commercial formulations.  相似文献   

12.
By using dc and ac polarography, the kinetics of electroreduction of the palladium (II) complexes with β-alanine at a dropping mercury electrode was studied in solutions with the palladium (II) concentration from 2 × 10?5 to 2 × 10?4 M and variable β-alanine and sodium perchlorate concentrations (pH 6–12). One polarographic wave was observed in solutions with pH 9 and 10 at the β-alanine overall concentration of c βala = 1 × 10?3 to 5 × 10?2 M; two waves, at lower pH or higher c βala. It was concluded on the formation of different forms of palladium (II) complexes in the studied solutions; the complexes contained two to four β-alanine coordinated anions. Using the limiting diffusion currents for the two waves at pH 9–11 and c βala = 0.1 and 0.5 M, the stepwise stability constant for the Pd(βala) 4 2? complex was calculated. Using two ac peaks observed at pH 7–8 and c βala = 1 × 10?2 to 0.1 M, the stepwise stability constant for the Pd(βala) 3 ? . was calculated. The perchlorate ions adsorbed at the dropping mercury electrode, as well as βala? anions at their higher concentrations, hamper the electroreduction of the palladium (II) complexes with β-alanine.  相似文献   

13.
A differential pulse polarographic (DPP) method has been developed for the determination of acipimox in its pharmaceutical formulations. Using Sörensen buffer pH 6.0 as supporting electrolyte a single, irreversible peak occurred at –0.79 V vs an Ag/AgCl reference electrode. The peak height vs concentration plot was found to be linear over the range of 10–6 to 6 × 10–4 mol/l. The detection limit is 60ng/ml. The analysis of a series of 10 Olbetam® 250 mg capsules showed an overall standard deviation of ± 4.18 mg and a Srel of ± 1.66%, respectively.  相似文献   

14.
The preconcentration and voltammetric behavior of BiIII on a sodium humate modified carbon paste electrode was studied by means of cyclic voltammetry (CV) and differential pulse stripping voltammetry (DPSV). The proposed measurement involves an initial nonelectrolytic preconcentration step in which BiIII is complexed by the surface modifier in a solution of 0.05 M KNO3-0.0106 M HNO3 (pH 2.0) and a subsequent electrochemical scan step in which the preconcentrated BiIII was reduced and then oxidized promptly in supporting electrolyte of 0.5 M HNO3. The resulting DPSV anodic current was proportional to the concentration of BiIII ion over the range of 4.78 × 10−8–1.44 × 10−5 M. The detection limit was 4.78 × 10−8 M. The proposed method was used to determine bismuth in various samples. Various factors affecting the electrode behavior were also investigated at the same time.  相似文献   

15.
The influence of important conditions for the determination of Ferbam by the anodic stripping technique has been studied: composition of base electrolyte, dependence on concentration, size of mercury drop, pre-electrolysis time and potential, speed of potential shift, temperature, and effect of stirring. The results are compared with those of determinations by classical polarography, and the electrode process is discussed. The smallest concentration of Ferbam for determination is 2.5 ng per ml (about 6×10–9 M) and for qualitative detection 0.5 ng per ml (about 1×10–9 M). The relative standard deviation of the method is about ±15%.In der Arbeit wird der Einfluß der bei der voltammetrischen Bestimmung von Ferbam [Eisen(III)-dimethyl-dithiocarbamat] bedeutsamen Versuchsparameter untersucht: Leitelektrolytzusammensetzung, Konzentrationsabhängigkeit, Größe des Quecksilbertropfens, Wartezeit und -potential, Potentialänderungsgeschwindigkeit, Temperatur und Rührwirkung. Die dabei erhaltenen Resultate werden mit den bei der klassisch-polaro-graphischen Bestimmung gemachten Beobachtungen verglichen und der Elektrodenvorgang diskutiert. Bei der Ferbambestimmung beträgt die Grenzkonzentration 2,5 ng/ml (etwa 6·10–9M) und für die qualitative Erkennung 0,5 ng/ml (etwa 1·10–9M). Der relative mittlere Fehler beträgt etwa ± 15%.  相似文献   

16.
The construction, performance characteristics and applications of a polymeric membrance electrode for lead(II) ion are reported. The electrode was prepared by incorporating cryptand(222) as the neutral carrier into a plasticized poly(vinyl chloride) membrane. The influence of membrane composition, pH and concentration of internal reference solution were investigated. The electrode exhibits a potentiometric response for Pb2+ ion over the concentration range 10–1–10–5 M with a detection limit of 5 × 10–6 M Pb2+. It shows a relatively fast response time of about 30 s and can be used for about two months without any considerable divergence in potential. The proposed sensor revealed good selectivities for Pb2+ in the presence of several metal ions and could be used in the pH range of 2.5 to 7.5. It was used as an indicator electrode in the potentiometric titration of Pb2+ with EDTA. Received: 20 November 1998 / Revised: 26 March 1999 / Accepted: 31 March 1999  相似文献   

17.
《Analytical letters》2012,45(3):599-607
ABSTRACT

The electrochemical polymerization of glutamic acid at the glassy carbon electrode was investigated in phosphate buffer solution by cyclic voltammetry. The applied voltage range, pH of electrolyte, cyclic number were explored for optimal polymerization conditions. The resulting film exhibits an electrocatalytic ability to hydrazine, reducing the overpotential by 500mV. The electrocatalytic response of hydrazine is evaluated with regard to pH, scan rate, applied voltage, hydrazine concentration and other variables. The rate constant of the catalytic reaction was 1.2 × 104 M?1.s?1. When used as amperometric detector, the modified electrode yields a detection limit of 1 × 10?8 M hydrazine. The electrode is rather stable even after use for a month and a reproducible response was obtained.  相似文献   

18.
2-Mercapto-N-2-naphthylacetamide (thionalide) on silica gel is used for rapid preconcentration of μg l?1 levels of palladium(II) from aqueous solution, followed by atomic absorption spectrometric measurement. In batch experiments, palladium was quantitatively retained on the gel from solutions 5 M in acid to pH 8; equilibrium was achieved within 10 s. The chelating capacity of the gel was 7.5 μmol Pd g?1 at pH < 4. The effect of flow rate on retention was studied. Palladium retained on the column was completely eluted with 20 ml of 0.2 M thiourea in 0.1 M hydrochloric acid. The palladium concentration in sea water is shown to be < 0.3 μg l?1.  相似文献   

19.
The electrochemical behavior of palladium(II) was studied by differential pulse, linear sweep, and alternating-current square-wave voltammetry in HC1, HNO3, H2SO4, and HC1O4 solutions in the presence of dimethylglyoxime. A peak with a height linearly depending on the concentration of palladium(II) was observed in voltammograms. Typical relationships between the height and potential of a peak and pH, dimethylglyoxime concentration, the potential and time of adsorption accumulation suggested that the observed peak was due to the hydrogen liberation catalyzed by palladium(II) dimethylglyoximate adsorbed on the electrode surface. The detection limits for palladium(II) accumulated for 120 s at -0.2 V were 2 x 10-8, 5 x 10-9, and 8 x 10-10 M for differential pulse, linear sweep, and alternating-current square-wave voltammetry, respectively.  相似文献   

20.
The construction, performance characteristics and applications of a polymeric membrance electrode for lead(II) ion are reported. The electrode was prepared by incorporating cryptand(222) as the neutral carrier into a plasticized poly(vinyl chloride) membrane. The influence of membrane composition, pH and concentration of internal reference solution were investigated. The electrode exhibits a potentiometric response for Pb2+ ion over the concentration range 10–1–10–5 M with a detection limit of 5 × 10–6 M Pb2+. It shows a relatively fast response time of about 30 s and can be used for about two months without any considerable divergence in potential. The proposed sensor revealed good selectivities for Pb2+ in the presence of several metal ions and could be used in the pH range of 2.5 to 7.5. It was used as an indicator electrode in the potentiometric titration of Pb2+ with EDTA. Received: 20 November 1998 / Revised: 26 March 1999 / Accepted: 31 March 1999  相似文献   