首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A ??E-E telescope exploiting a single silicon chip for both ??E measurement and scintillation light collection has been tested. It is a Si - CsI (Tl) telescope tailored for mass identification of light charged particles and intermediate mass fragments. A procedure based on two different shaping filters allows for extraction of the ??E-E information from the single silicon signal. The quality of the obtained fragment identification is expressed in terms of a figure of merit and compared to that of a standard ??E-E telescope. The presented configuration could be a good candidate for the basic cell of a large solid angle array of ??E-E telescopes, given the reduction in complexity and cost of the front-end electronics.  相似文献   

2.
A novel system to study the effect of an axial periodic electric field on the stability of a system of cylinders of conducting fluids in the presence of heat and mass transfer is investigated. The stability of a cylindrical interface between the vapor and liquid phases of a fluid is studied when the vapor is hotter than the liquid and the two phases are enclosed between two cylindrical surfaces coaxial with the interface. The linear dispersion relation is found to be of damped Mathieu-type equation with real coefficients. The method of multiple time scales is used to obtain approximate solution and analyze the stability criteria for both the nonresonant and resonant cases. The stability of the system is also discussed analytically and numerically for such cases. It is found that both the heat and mass transfer coefficient and the dimensions of the system have destabilizing influences on the considered system, while azimuthal wavenumber is found to have a stabilizing effect. The dual role of the electric field frequency is also observed on the stability of the system depending on the electrical conductivities values. Finally the behaviour of the resonance points corresponding to the effects of each of the above physical parameters are determined, and a comparison between the obtained results with the corresponding results in the case of a constant applied electric field is achieved.  相似文献   

3.
喷淋蒸发翅管式冷凝器传热传质研究   总被引:1,自引:0,他引:1  
王铁军 《低温与超导》2006,34(4):299-302
采用蒸发式冷凝器可以降低制冷装置不可逆传热损失,提高机组效率。该文提出在制冷装置中采用喷淋蒸发翅管式冷凝器,分析了喷淋蒸发翅管式冷凝器的传热过程,建立其传热传质数学模型和设计计算方法,简要分析了环境温湿度、管翅结构、风速、淋水量等一些主要因素对传热传质性能的影响,为该种冷凝器的设计和应用提供理论参考。  相似文献   

4.
The primary stationary and oscillatory Bénard-Marangoni instability is investigated in a fluid layer of infinite horizontal extent, bounded below by a rigid plane and above by a deformable upper surface, subjected to a vertical temperature gradient. Since the viscosity is temperature-dependent the consequences of relaxing Oberbeck-Boussinesq approximation and free surface deformability are theoretically examined by means of small disturbance analysis. The problem has been solved numerically by the Taylor series expansion method. The results obtained confirm that when the free surface is undeformable, stationary convection develops in the form of polygonal cells, and oscillatory motion cannot be detected. When the surface deformability is considered, stationary convection sets in, either as a short-wavelength hexagonal instability or as a long-wavelengh mode or as both, and oscillatory convection is also possible. The stability threshold for the short-wavelength mode depends mainly on the viscosity variation while the long-wavelength mode is determined by the surface deformation. Numerically, it is found that the neutral oscillatory Marangoni numbers are only negative. When a variable-viscosity model is used the theoretical and experimental results are in better agreement. Received 15 May 1997  相似文献   

5.
根据传热传质分离的吸收形式,设计加工了一台溴化锂绝热降膜吸收的实验装置,对溴化锂水溶液在倾斜平板上对水蒸气的吸收特性进行了实验研究,分析了预冷却温差、溶液流量及平板倾角对吸收过程的影响。实验结果表明:预冷却温差、溶液流量及平板倾角越大,溴化锂溶液对水蒸气的吸收效果越好,并认为吸收过程可以分成三个步骤,另外就热质分离吸收器的设计过程中的溴化锂溶液的最小速度提出建议。  相似文献   

6.
Nanofluids, because of their enhanced heat transfer capability as compared to normal water/glycol/oil based fluids, offer the engineer opportunities for development in areas where high heat transfer, low temperature tolerance and small component size are required. In this present paper, the hydrodynamic and thermal fields of a water–γAl2O3 nanofluid in a radial laminar flow cooling system are considered. Results indicate that considerable heat transfer enhancement is possible, even achieving a twofold increase in the case of a 10% nanoparticle volume fraction nanofluid. On the other hand, an increase in wall shear stress is also noticed with an increase in particle volume concentration.  相似文献   

7.
The objective of this study has been to experimentally analyze the correlation structure of the strong temporal intermittency which characterizes pipe flow close to the transition to turbulence. In doing so transitional pipe flow has been analyzed by Laser Doppler velocimetry and the Reynolds number dependence of the covariance function has been studied. The range which has been analyzed covers the transition to turbulence and moderately developed turbulence (Reynolds number from 1 500 to 5 000). The correlation structure which has been evidenced is generally in agreement with the deterministic, dynamical, interpretation of temporal intermittency which explains the intermittent behavior as a result of a saddle node bifurcation. However, the analysis has evidenced fluctuations even before the onset of turbulence. The structure of these fluctuations is perfectly autoregressive which leads us to conclude that the transition to turbulence can be viewed as a transition from linear randomness to (non-linear) homogeneity. Received 29 March 1999 and Received in final form 6 September 1999  相似文献   

8.
We scrutinize the approximate analytical solutions by the optimal homotopy analysis method (OHAM) for the flow and mass transfer within the Marangoni boundary layer of power-law fluids over a disk with suction and injection in the present paper. Concentration distribution on the surface of a disk varies in a power-law form. The non-Newtonian fluid flow is due to the surface concentration gradient without considering gravity and buoyancy. According to the conservation of mass, momentum and concentration, the governing partial differential equations are established, and the appropriate generalized Kármán transformation is found to reduce them to the nonlinear ordinary differential equations. OHAM is used to access the approximate analytical solution. The influences of Marangoni the number, suction/injection parameters and power-law exponent on the flow and mass transfer are examined.  相似文献   

9.
In this paper the effects of electrohydrodynamics (EHD) on heat transfer enhancement and flow pattern of R134a two-phase mixture, flowing in a horizontal tube, were numerically investigated. A uniform DC electric field was applied through a circular stainless steel rod along the centerline of tube, while the tube was considered as a grounded electrode. The simulations, in order to investigate the EHD mechanism, were performed for a constant heat flux 2000 W/m2, voltages between 0 and 5 kV, inlet volume fractions 65% and 85%, mass fluxes from 30 kg/m2s to 50 kg/m2s and electrode diameters between 1.57 mm and 2.4 mm. These flow conditions correspond to stratified flow. The flow regime redistributions under the applied electric field was obtained. The results show that the steady state condition was occurred at the time about 900 ms. According to the results, enhancement ratio is directly proportional to voltage, and it is reversely proportional to electrode diameter, mass flux and inlet volume fraction.  相似文献   

10.
This study aimed at investigating the performances of air drying of blackberries assisted by airborne ultrasound and contact ultrasound. The drying experiments were conducted in a self-designed dryer coupled with a 20-kHz ultrasound probe. A numerical model for unsteady heat and mass transfer considering temperature dependent diffusivity, shrinkage pattern and input ultrasonic energies were applied to explore the drying mechanism, while the energy consumption and quality were analyzed experimentally. Generally, both airborne ultrasound and contact ultrasound accelerated the drying process, reduced the energy consumption and enhanced the retentions of blackberry anthocyanins and organic acids in comparison to air drying alone. At the same input ultrasound intensity level, blackberries received more ultrasound energies under contact sonication (0.299 W) than airborne sonication (0.245 W), thus avoiding the attenuation of ultrasonic energies by air. The modeling results revealed that contact ultrasound was more capable than airborne ultrasound to intensify the inner moisture diffusion and heat conduction, as well as surface exchange of heat and moisture with air. During air drying, contact ultrasound treatment eliminated the gradients of temperature and moisture inside blackberry easier than airborne ultrasound, leading to more homogenous distributions. Moreover, the total energy consumption under air drying with contact ultrasound assistance was 27.0% lower than that with airborne ultrasound assistance. Besides, blackberries dehydrated by contact ultrasound contained more anthocyanins and organic acids than those dried by airborne ultrasound, implying a higher quality. Overall, direct contact sonication can well benefit blackberry drying in both energy and quality aspects.  相似文献   

11.
The steady flow and heat transfer of an electrically conducting fluid with variable viscosity and electrical conductivity between two parallel plates in the presence of a transverse magnetic field is investigated. It is assumed that the flow is driven by combined action of axial pressure gradient and uniform motion of the upper plate. The governing nonlinear equations of momentum and energy transport are solved numerically using a shooting iteration technique together with a sixth-order Runge-Kutta integration algorithm. Solutions are presented in graphical form and given in terms of fluid velocity, fluid temperature, skin friction and heat transfer rate for various parametric values. Our results reveal that the combined effect of magnetic field, viscosity, exponents of variable properties, various fluid and heat transfer dimensionless quantities and the electrical conductivity variation, have significant impact on the hydromagnetic and electrical properties of the fluid.  相似文献   

12.
The present study treats the effects of mass transport, heat transfer and chemical reactions heat on the bubble dynamics by spanning a range of ambient bubble radii. The thermodynamic behavior of the acoustic bubble was shown for three wave frequencies, 355, 515 and 1000 kHz. The used acoustic amplitude ranges from 1 to 3 atm. It has been demonstrated that the ambient bubble radius, R0, of the maximal response (i.e., maximal bubble temperature and pressure, Tmax and Pmax) is shifted toward lower values if the acoustic amplitude (at fixed frequency) or the ultrasonic frequency (at fixed amplitude) are increased. The range of the ambient bubble radius narrows as the ultrasonic frequency increases. Heat exchange at the bubble interface was found to be the most important mechanism within the bubble internal energy balance for acoustic amplitudes lower than 2.5 and 3 atm for ultrasonic frequencies of 355 and 515 kHz, respectively. For acoustic amplitudes greater or equal to 2.5 and 3 atm, corresponding to 355 and 515 kHz, respectively, mass transport mechanism (i.e., evaporation and condensation of water vapor) becomes dominant compared to the other mechanisms. At 1000 kHz, the mechanism of heat transfer persists to be dominant for all the used acoustic amplitudes (from 1 to 3 atm). Practically, all the above observations were maintained for bubbles at and around the optimum bubble radius, whereas no significant impact of the three energetic mechanisms was observed for bubbles of too lower and too higher values of R0 (limits of the investigated ranges of R0).  相似文献   

13.
An analysis based on the available experimental data and second-order closures is made for a turbulent shear flow over a rotating cylinder in a quiescent fluid. The near-wall behaviour of the non-linear model for the pressure-strain correlation proposed by Speziale, Sarkar and Gatski [J. Fluid Mech. 245, 227 (1991)] is enlarged; and the methodology proposed by Lai and So [J. Fluid Mech. 221, 641 (1990)] is adopted to take into account the wall-effects. The radial profile of the curvature parameter, Rs, is examined in connection with the logarithmic law. It is shown that the log-layer is associated to the region where the mean velocity profile, V, is related to the power of the radial distance as Computations reveal that this region corresponds to the state with the most destabilizing curvature effects; which can be chararacterized by the minimum value of the parameter B c =2R s (1+2R s ), and not that one of the parameter B=2R s (1+2R s )/(1+R s )2 firstly introduced by Bradshaw [J. Fluid Mech. 36, 171 (1969)] and extensively used to characterize the turbulence structure in curved flows. Received 9 December 1997  相似文献   

14.
This Letter presents a numerical study of the flow and heat transfer of an incompressible FENE-P fluid over a non-isothermal surface. The governing partial differential equations are converted into ordinary differential equations by a similarity transformation. The effects of the thermal radiation are considered in the energy equation, and the variations of dimensionless surface temperature and dimensionless surface temperature gradient, as well as the heat transfer characteristics with various physical parameters are graphed and tabulated. Two cases are studied, namely, (i) the sheet with prescribed surface temperature (PST case) and (ii) the sheet with prescribed heat flux (PHF case). Moreover, the mechanical characteristics of the corresponding flow are also presented.  相似文献   

15.
The efficacy of power ultrasound of 20 kHz in enhancing the volumetric mass transfer coefficient was investigated in this study. Breakage and dissolution of sparingly soluble benzoic acid dispersed in either water or 24% aqueous glycerol was monitored as a function of time and ultrasound power input. Particle size measurements were carried out at intermediate times during the experiment to estimate the mean particle size and surface area. Linear combination of lognormal distributions was found to fit the experimental particle size distribution data. The De Brouckere mean diameters (d43) obtained from the particle size distributions decreased with increase in the ultrasonic power level. Empirical correlations were developed for the evolution of surface area as a function of ultrasonic energy input per unit mass. The effect of ultrasound on the intrinsic mass transfer coefficient (kc) could be decoupled from the volumetric mass transfer coefficient (kca) as the surface area was also estimated. Different approaches involving either constant or variable intrinsic mass transfer coefficients were employed when carrying out the delineation. Mass transfer rates were enhanced due to both higher ultrasound induced intrinsic convective mass transfer coefficient and additional surface area created from particle breakage. To delineate the effects of particle breakage from solid dissolution, experiments were also carried out under non-mass transfer conditions by pre-saturating the solvents with benzoic acid. Both the solid-liquid systems examined in the present study attained saturation concentration when the ultrasonic energy input per unit mass was approximately 60 kJ/kg, irrespective of the ultrasonic power level setting.  相似文献   

16.
采用SST k-w低雷诺数湍流模型对加热条件下超临界压力CO2在内径di=22.14 mm,加热长度Lh=2440 mm水平圆管内三维稳态流动与传热特性进行了数值计算.通过超临界CO2在水平圆管内的流动传热实验数据验证了数值模型的可靠性和准确性.首先,研究了超临界压力CO2在水平圆管内的流动传热特点,基于超临界CO2在类临界温度Tpc处发生类液-类气“相变”的假设,揭示了水平圆管顶母线和底母线区域不同的流动传热行为.然后,分析了热流密度qw和质量流速G对水平圆管内超临界压力CO2流动换热的影响,通过获取流体域内的物性分布、速度分布和湍流分布等详细信息,重点解释了不同热流密度qw和质量流速G下顶母线内壁温度Tw,i分布产生差异的传热机理,分析结果确定了类气膜厚度d、类气膜性质、轴向速度u和湍动能k是影响顶母线壁温分布差异的主要因素.研究结果可以为超临界压力CO2换热装置的优化设计和安全运行提供理论指导.  相似文献   

17.
氨水降膜吸收传热传质强化的研究进展   总被引:1,自引:0,他引:1  
综述了近年来应用于氨水降膜吸收性能强化的研究成果,总结了氨水降膜吸收的强化方法,分析了氨水降膜吸收过程中的影响因素,指出研究中的一些不足,并对该领域未来的研究方向进行了讨论,指出采用物理处理、化学处理和纳米技术三种强化手段相结合的方法是未来强化吸收可能的发展趋势。  相似文献   

18.
采用由SRK方程计算得出的混合工质物性参数,将具有相变两相流体物性分三部分处理,得出混合工质分段物性数据拟合曲线,并输入FLUENT软件的材料物性数据文件中,作为数值模拟物性参数数据。在上述物性数据处理的基础上,对混合工质天然气液化装置中换热器采用分段方式进行稳态数值模拟研究,得到沿长度方向一定温度下传热系数、压力梯度的变化曲线。通过与MUSE软件数据比较,计算结果有一定合理性,所得结论为有相变换热的混合工质低温板翅式换热器的设计和优化提供一定参考。  相似文献   

19.
In this analysis,the magnetohydrodynamic boundary layer flow of Casson fluid over a permeable stretching/shrinking sheet in the presence of wall mass transfer is studied.Using similarity transformations,the governing equations are converted to an ordinary differential equation and then solved analytically.The introduction of a magnetic field changes the behavior of the entire flow dynamics in the shrinking sheet case and also has a major impact in the stretching sheet case.The similarity solution is always unique in the stretching case,and in the shrinking case the solution shows dual nature for certain values of the parameters.For stronger magnetic field,the similarity solution for the shrinking sheet case becomes unique.  相似文献   

20.
Eivind Johannessen  Dick Bedeaux   《Physica A》2006,370(2):258-274
We derived integral relations for the heat and mass transfer resistivities of the liquid–vapor interface in a one-component system. These relations were obtained assuming the validity of the standard expression for the local entropy production rate as the product of the measurable heat flux times the gradient of the inverse temperature through the surface. The integral relations will be useful to interpret results from nonequilibrium molecular dynamics simulations. We verified in this paper that earlier results obtained using the nonequilibrium van der Waals square gradient model are reproduced. For this case, we calculated the Kapitza length along the coexistence curve.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号