首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
The Visual Immunoprecipitate Assay (VIP) method for the detection of enterohemorrhagic Escherichia coli O157:H7 (VIP for EHEC) and Assurance Enzyme Immunoassay (EIA) method for the detection of EHEC (EHEC EIA) are AOAC INTERNATIONAL Official Methods 996.09 and 996.10, respectively. A minor modification to the enrichment medium used in both methods has been developed. This modification, the BioControl modified EHEC medium (BioControl mEHEC) provides a more cost-effective procedure with performance equivalent to that of the cultural method for detection of E. coli O157:H7 in beef.  相似文献   

2.
The Visual Immunoprecipitate (VIP) for the Detection of E. coli O157:H7 in Foods, AOAC Official Method 996.09, has been modified to use a simplified plastic housing for the device. A methods comparison study was conducted to demonstrate the equivalence of this modification to the reference culture method. Three foods were analyzed. In total, valid results were obtained from 240 samples and controls. Results showed that the VIP for E. coli O157:H7 is equivalent to the reference culture methods for the detection of E. coli O157:H7.  相似文献   

3.
AOAC Official Method 996.10, Assurance Enzyme Immunoassay (EIA) for Escherichia coli O157:H7 (EHEC), was modified to incorporate a new enrichment protocol using BioControl EHEC8 medium for testing raw and cooked beef. Foods were tested by EIA and the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) enrichment conditions and the FDA Bacteriological Analytical Manual (BAM) isolation and confirmation techniques. A total of 14 collaborators participated. Raw and cooked ground beef were inoculated with E. coli O157:H7 at 2 different levels: a high level where predominantly positive results were expected, and a low level where fractional recovery was anticipated. Collaborators tested 378 test portions and controls by both the 8 h EIA and the USDA/FSIS enrichment methods, for a total of 756 test portions. Of the 378 paired test portions, 75 were positive and 212 were negative by both methods. Thirteen test portions were presumptively positive by EIA and could not be confirmed culturally; 30 were negative by EIA, but confirmed positive by culture; and 65 were negative by the culture method, but confirmed positive by the EIA method. There was no statistical difference between results obtained with the Assurance EIA for EHEC 8 h method and the culture method for raw ground beef. The Assurance EIA had a significantly higher recovery for cooked beef.  相似文献   

4.
Reveal E. coli 2.0 is a new lateral-flow immunodiagnostic test for detection of E. coli O157:H7 and O157:NM in raw beef trim and ground beef. Compared with the original Reveal E. coli O157:H7 assay, the new test utilizes a unique antibody combination resulting in improved test specificity. The device architecture and test procedure have also been modified, and a single enrichment protocol was developed which allows the test to be performed at any point during an enrichment period of 12 to 20 h. Results of inclusivity and exclusivity testing showed that the test is specific for E. coli serotypes O157:H7 and O157:NM, with the exception of two strains of O157:H38 and one strain of O157:H43 which produced positive reactions. In internal and independent laboratory trials comparing the Reveal 2.0 method to the U.S. Department of Agriculture-Food Safety and Inspection Service reference culture procedure for detection of E. coli O157:H7 in 65 and 375 g raw beef trim and ground beef samples, there were no statistically significant differences in method performance with the exception of a single internal trial with 375 g ground beef samples in which the Reveal method produced significantly more positive results. There were no unconfirmed positive results by the Reveal assay, for specificity of 100%. Results of ruggedness testing showed that the Reveal test produces accurate results even with substantial deviation in sample volume or device incubation time or temperature. However, addition of the promoter reagent to the test sample prior to introducing the test device is essential to proper test performance.  相似文献   

5.
Four different food types along with environmental swabs were analyzed by the Reveal for E. coli O157:H7 test (Reveal) and the Bacteriological Analytical Manual (BAM) culture method for the presence of Escherichia coli O157:H7. Twenty-seven laboratories representing academia and private industry in the United States and Canada participated. Sample types were inoculated with E. coli O157:H7 at 2 different levels. Of the 1,095 samples and controls analyzed and confirmed, 459 were positive and 557 were negative by both methods. No statistical differences (p <0.05) were observed between the Reveal and BAM methods.  相似文献   

6.
He X  Zhou L  He D  Wang K  Cao J 《The Analyst》2011,136(20):4183-4191
A novel, fast and sensitive determination strategy for E. coli O157:H7 has been developed by combination of ligandmagnetic nanoparticles (LMNPs) enrichment with a fluorescent silica nanoparticles (FSiNPs) based two-color flow cytometry assay (LMNPs@FSiNPs-FCM). E. coli O157:H7 was first captured and enriched through the lectin concanavalin A (Con A) favored strong adhesion of E. coli O157:H7 to the mannose-conjugated magnetic nanoparticles. The enriched E. coli O157:H7 was further specially labeled with goat anti-E. coli O157:H7 antibody modified RuBpy-doped FSiNPs, and then stained with a nucleic acid dye SYBR Green I (SYBR-I). After dual-labeling with FSiNPs and SYBR-I, the enriched E. coli O157:H7 was determined using multiparameter FCM analysis. With this method, the detection sensitivity was greatly improved due to the LMNPs enrichment and the signal amplification of the FSiNPs labelling method. Furthermore, the false positives caused by aggregates of FSiNPs conjugates and nonspecific binding of FSiNPs to background debris could be significantly decreased. This assay allowed the detection of E. coli O157:H7 in PB buffer at levels as low as 7 cells mL(-1). The total assay time including E. coli O157:H7 sample enrichment and detection was less than 4 h. An artificially contaminated bottled mineral water sample with a concentration of 6 cells mL(-1) can be detected by this method. It is believed that the proposed method will find wide applications in biomedical fields demanding higher sensitive bacterial identification.  相似文献   

7.
The performance of the Soleris E. coli method was compared with that of the ISO 7251 most probable number (MPN) and detection reference methods for Escherichia coli. The Soleris E. coli method is a growth-based, rapid, automated system composed of temperature-controlled incubation chambers and photodiode-based optical detection devices for measurement of color changes in a prepared medium vial. A dilution of the test sample homogenate is inoculated directly into the vial. Products of E. coli metabolism alter the color of the medium over time, and this change is monitored by the Soleris instrument. The test is used in a dilute-to-specification or specification monitoring manner in which the result is positive or negative around a desired cutoff (in CFU/g) determined by the dilution and volume of sample homogenate added to the vial. Alternatively, the test is used for zero tolerance determinations (e.g., absence in 25 g) by performing an off-line pre-enrichment step followed by transfer of a portion of the pre-enrichment culture to the Soleris vial. Six E. coli strains originating from food sources were inoculated individually into six food commodities: frozen green beans, Echinacea powder, cocoa powder, sweetened condensed milk, pasteurized liquid egg, and shredded mozzarella cheese. Uninoculated samples were included in each trial. The results obtained by the ISO 7251 detection method and the Soleris E. coli method were shown to be in agreement by Chi-square analysis when the presence of E. coli was determined in 25 g of sample. Results from the Soleris E. coli dilute-to-specification method and the ISO 7251 MPN method were found to be in agreement by probability of detection statistical analysis. In inclusivity testing, 52 of 53 E. coli strains were detected within 24 h. Only a non-thermoduric strain of serotype O157:H43 was not detected. In exclusivity testing, all 31 strains tested produced negative results. Results of ruggedness experiments show that accurate results can be obtained even when the operating temperature of the Soleris instrument is set beyond normal tolerances. The internal and independent laboratory studies demonstrated that the Soleris E. coli method could be successfully utilized as an alternative to the reference methods, with a significant time savings of 2 to 3 days.  相似文献   

8.
The relative effectiveness of the SimPlate Coliform and E. coli Color Indicator (CEc-CI) method was compared to the AOAC 3-tube Most Probable Number (MPN) methods for enumerating and confirming coliforms and Escherichia coli in foods (966.23 and 966.24). In this study, test portions were prepared and analyzed according to the conditions stated in both the AOAC methods and SimPlate directions for use. Six food types were artificially contaminated with coliform bacteria and E. coli: frozen burritos, frozen broccoli, fluid pasteurized milk, whole almond nut meats, cheese, and powdered cake mix. Method comparisons were conducted. Overall, the SimPlate method demonstrated <0.3 log difference for total coliform and E. coli counts compared to the AOAC reference methods for the majority of food types and levels analyzed. In all cases, the repeatability and reproducibility of the SimPlate CEc-CI method were not different from those of the reference methods and in certain cases, were statistically better than those of the AOAC 3-tube MPN methods. These results indicate that the SimPlate CEc-CI method and the reference culture methods are comparable for enumeration of both total coliforms and E. coli in foods.  相似文献   

9.
An independent laboratory study of the BAX for Screening/E. coli O157:H7 kit was conducted at the National Food Laboratory, Inc., Dublin, CA, to complete AOAC Performance Tested Method certification. The BAX system kit was compared with the BAM culture method and a modified BAM culture method for detection of E. coli O157:H7 in ground beef. The BAX system kit detected the target organism at levels approximately 10-fold lower than those that gave positive BAM results. This study validated product claims, and Performance Tested Method status was granted.  相似文献   

10.
Five different food types were analyzed by the Reveal for E. coli O157:H7 8-Hour Test System (Reveal 8) and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual (BAM) culture method or the U.S. Department of Agriculture Food Safety Inspection Service (FSIS) culture method for the presence of E. coli O157:H7. A total of 27 laboratories representing academia and private industry in the United States and Canada participated. Food types were inoculated with E. coli O157:H7 at 2 different levels: a high level where predominantly positive results were expected, and a low level where fractional recovery was anticipated. During this study, 1,110 samples and controls were analyzed by both the Reveal 8 and by BAM or FSIS by each of the collaborators (2,220 samples in total). For each set of samples, 740 were artificially inoculated with E. coli O157:H7, and 370 were uninoculated controls. The Reveal 8 detected 528 presumptive positives of which 487 were confirmed positive by the BAM culture method. In comparison, BAM and FSIS detected 489 of the 740 artificially contaminated samples as positive. In an additional in-house study performed only on chilled and frozen raw ground beef, 240 artificially inoculated samples were analyzed by both the Reveal 8 and by FSIS. The Reveal 8 detected and confirmed 104 samples as positive compared to 79 confirmed positive by FSIS.  相似文献   

11.
A silicon microcantilever sensor was developed for the detection of Escherichia coli O157:H7. The microcantilever was modified by anti-E. coli O157:H7 antibodies on the silicon surface of the cantilever. When the aquaria E. coli O157:H7 positive sample is injected into the fluid cell where the microcantilever is held, the microcantilever bends upon the recognition of the E. coli O157:H7 antigen by the antibodies on the surface of the microcantilever. A negative control sample that does not contain E. coli O157:H7 antigen did not cause any bending of the microcantilever. The detection limit of the sensor was 1 x 10(6) cfu/mL when the assay time was < 2 h.  相似文献   

12.
Six foods representative of a wide variety of processed, dried powder processed, and raw food types were analyzed by the Assurance Gold Salmonella Enzyme Immunoassay (EIA) and AOAC INTERNATIONAL culture method. Paired samples of each food type were simultaneously analyzed; one sample by the Assurance method and one by the AOAC culture method. The results for Assurance method were read visually and instrumentally with a microplate reader. A total of 24 laboratories representing federal government agencies and private industry, in the United States and Canada, participated in this collaborative study. Food types were inoculated with species of Salmonella with the exception of raw ground chicken, which was naturally contaminated. No statistical differences (p < 0.05) were observed between Assurance Gold Salmonella EIA with either visual or instrumental interpretation and the AOAC culture method for any inoculation level of any food type or naturally contaminated food. The Assurance visual and instrumental options of reading sample reactions produced the same results for 1277 of the 1296 sample and controls analyzed.  相似文献   

13.
AOAC Official Method 996.09, Visual Immunoprecipitate Assay (VIP) for Escherichia coli O157:H7, was modified to incorporate a new enrichment protocol using BioControl EHEC8 medium for testing raw and cooked beef. Foods were tested by VIP assay and the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) enrichment procedure and the FDA Bacteriological Analytical Manual (BAM) isolation and confirmation techniques. A total of 15 collaborators participated. Raw and cooked ground beef were inoculated with E. coli O157:H7 at 2 different levels: a high level, where predominantly positive results were expected, and a low level where fractional recovery was anticipated. Collaborators tested 396 test portions and controls by both methods, for a total of 792 test portions. Of the 396 paired test portions, 75 were positive and 230 were negative by both the VIP and culture methods. Eleven test portions were presumptively positive by VIP and could not be confirmed culturally; 32 were negative by VIP, but confirmed positive by culture; and 65 were negative by the culture method, but confirmed positive by the VIP method. There was no statistical difference between results obtained with the VIP for EHEC 8 h method and the culture method except for cooked beef, where the VIP had significantly higher recovery for one inoculation level.  相似文献   

14.
利用伴刀豆球蛋白A(Con A)的多价结合能力, 结合水凝胶技术与核酸染色技术发展了一种基于甘露糖功能化的水凝胶检测大肠杆菌(E.coli)O157: H7的方法. 以过硫酸铵(APS)为催化剂, 四甲基乙二胺(TEMED)为加速剂, 用丙烯酰胺(AAm)、N,N-二甲基双丙烯酰胺和N-丙烯酰氧琥珀酰亚胺(NAS)合成水凝胶, 通过氨基化甘露糖与NAS发生交联反应, 制备了甘露糖功能化的水凝胶. 当甘露糖功能化的水凝胶加入与Con A共孵育后的菌悬液中时, 由于Con A既能与甘露糖特异性结合, 又能与E.coli O157: H7表面的O-抗原发生免疫反应而紧密连接, 使目标菌被捕获到水凝胶表面, 采用核酸染料SYBR Green Ⅰ对捕获细菌进行染色, 实现了对E.coli O157: H7的核酸标记, 最后通过活体荧光成像系统对水凝胶进行荧光成像, 从而实现对待测样品的检测. 研究结果表明, 该方法可应用于缓冲液体系和混合细菌样品中E.coli O157: H7的特异性检测, 且整个检测步骤包括样品预处理可在2 h内完成. 该方法成本低、易操作, 且具有较好的灵敏度, 可检出3.7×101 Cells/mL的目标细菌样品.  相似文献   

15.
化学发光磁酶免疫已经被应用于检测病原体,但是由于针对相应病原体的抗体筛选和修饰等的步骤耗时费力,不适于对多种病原体进行筛查.制备了兔抗大肠杆菌(E.coli)O157:H7的免疫磁性纳米颗粒,富集病原菌后与鼠抗E.coli O157:H7的单克隆抗体形成双抗夹心,采用碱性磷酸酶标记的马抗鼠IgG与单抗结合,加入碱性磷酸酶的化学发光底物试剂3-(2'-螺旋金刚烷)-4-甲氧基-4-(3'-羟基)苯-1,2-二氧杂环丁烷磷酸检测化学发光.实验研究了底物缓冲液、碱性磷酸酶浓度对化学发光强度的影响,比较了NaBH4和甘氨酸对免疫磁珠剩余活性醛基的封闭效果以及本方法检测E.coli O157:H7的特异性和敏感性.结果表明,碱性磷酸酶与底物在c缓冲液中反应的化学发光强度最高,碱性磷酸酶浓度决定了化学发光的强度和持续时间,NaBH4对活性醛基的封闭效果优于甘氨酸,以D群宋内氏志贺氏菌、B群福氏志贺氏菌、鼠伤寒沙门氏菌、金黄色葡萄球菌和霍乱弧菌及E.coli Top10f'为对照的比较实验显示,该检测方法具有良好的特异性,以1mL的菌液为检测体积时对E.coli O157:H7的检测灵敏度为103cell/mL,整个方法的检测时间约为3h.该方法适用于对多样本进行筛查.  相似文献   

16.
Lettuce was inoculated with a six-strain cocktail of acid-adapted Escherichia coli 0157:H7 at a level of 1×107 CFU/g. Following chlorination at 200 μg/ml, the lettuce was irradiated at 0.15, 0.38, or 0.55 kGy using a 60Co source. Survival of E. coli 0157:H7, aerobic mesophiles and yeast and molds were measured over a period of 10 days. For quality analysis, chlorinated lettuce was subjected to irradiation at 0.33 and 0.53 kGy and stored at 1.0°C, 4.0°C or 7.0°C. Changes in texture and color were determined by instrumental means and changes in flavor, odor, and visual quality were determined by sensory testing.

Chlorination plus irradiation at 0.55 kGy produced a 5.4−log reduction in E. coli 0157:H7 levels. Chlorination alone reduced the E. coli 0157:H7 counts by 1–2 logs. Irradiation at 0.55 kGy was also effective in reducing standard plate counts and yeast and mold counts. Irradiation at this level did not cause softening of lettuce and sensory attributes were not adversely affected. In general, appearance and flavor were affected more by the length of storage than by temperature conditions. The 5+log reduction in E. coli counts and lack of adverse effects on sensory attributes indicate that low-dose irradiation can improve the safety and shelf-life of fresh-cut iceberg lettuce for retail sale or food service.  相似文献   


17.
将免疫荧光纳米标记技术与激光共聚焦显微成像方法相结合,发展了一种基于二氧化硅荧光纳米颗粒和核酸染料SYBR Green Ⅰ的双色显微成像技术用于大肠杆菌O157:H7的检测.采用联吡啶钌(RuBpy)二氧化硅荧光纳米颗粒对羊抗大肠杆菌O157:H7抗体进行修饰,基于抗体-抗原相互作用实现了其对目标大肠杆菌O157:H7...  相似文献   

18.
《Analytical letters》2012,45(5):874-884
An immunoassay for Escherichia coli O157:H7 using quantum-dot (QD) labeling and subsequent release of the QD labels from immunocomplexes has been developed. The assay principle is that anti-E. coli O157:H7 conjugated immunomagnetic beads are used to capture E. coli O157:H7; this is followed by the binding of QD labeled antibodies to form sandwich immunocomplexes (Bead-Cell-QD); a dissociation buffer then elutes QDs from immunocomplexes by denaturing antibody or lysing cell; the fluorescence signal of the eluted QDs is measured to quantify E. coli O157:H7. This proposed approach avoids the interference of bead autofluorescence in signal transduction and, thus, enhances the detection resolution, while keeping the fast magnetic separation and sandwich binding of two selective antibodies for high specificity.  相似文献   

19.
A composite self-excited millimeter-sized lead zirconate titanate (PZT) glass cantilever (2 mm x 1.8 mm; sensing area of 6 mm2) was fabricated for the detection of Escherichia coli (E. coli) O157:H7. The fundamental and second mode resonance in air was 10.95 +/- 0.05 kHz and 43.45 +/- 0.05 kHz, respectively. Affinity purified monoclonal antibody (anti-E. coli O157:H7) specific to the pathogen E. coli O157:H7 was immobilized at the cantilever glass tip, and then immersed in liquid containing the pathogen (70 to 7 x 10(7) cells/mL). The resonant frequency showed a reduction and reached a steady state shift of 0 +/- 5, 46 +/- 5, 260 +/- 5, and 1010 +/- 5 Hz corresponding to 0, 700, 7000, and 7 x 10(7) cells/mL. From the experiments conducted, the detection limit of the sensor was 700 cells/mL.  相似文献   

20.
The current AOAC Method 966.24 for enumeration of Escherichia coli in foods uses a most probable number (MPN) procedure with extensive confirmation steps. Two new methods based on membrane filtration (MF) were compared to the MPN reference method for detection of high levels of E. coli in 5 food types, some of which represent categories for which the U.S. Food and Drug Administration (FDA) mandates additional testing if an action level of 10(4)/g E. coli is exceeded. Ground beef, which is not FDA regulated, was also tested. The 5 food types were all inoculated at 3 levels: 10(2)/g, > or = 10(4)/g, and > or = 10(5)/g E. coli. An MF protocol using either m-ColiBlue24 (CB) or lauryl sulfate tryptose plus BCIG (LST/BCIG) was an effective potential alternative to the reference method. Sensitivity and specificity for both CB and LST/BCIG were 98 and 100%, respectively. Agreement between MPN and both CB and LST/BCIG was 98%. The 2 proposed methods allow completion of both presumptive and confirmatory steps in 1-3 days, whereas the reference method requires as many as 11 days. Exclusivity testing with 50 non-E. coli strains indicated 100% were correctly ruled out by the proposed protocols. Inclusivity testing was used to determine whether typical results were obtained after incubation of E. coli cultures on CB or LST/BCIG for 24 h. Of 50 E. coli strains tested, 100% yielded typical results after incubation on CB, and 98% yielded typical results after incubation on LST/BCIG.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号