首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Sewage sludge is a hazardous waste, which must be managed adequately. Mesophilic anaerobic digestion is a widely employed treatment for sewage sludge involving several disadvantages such as low methane yield, poor biodegradability, and nutrient imbalance. Tomato waste was proposed as an easily biodegradable co-substrate to increase the viability of the process in a centralized system. The mixture proportion of sewage sludge and tomato waste evaluated was 95:5 (wet weight), respectively. The stability was maintained within correct parameters in an organic loading rate from 0.4 to 2.2 kg total volatile solids (VS)/m3 day. Moreover, the methane yield coefficient was 159 l/kg VS (0 °C, 1 atm), and the studied mixture showed a high anaerobic biodegradability of 95 % (in VS). Although the ammonia concentration increased until 1,864?±?23 mg/l, no inhibition phenomenon was determined in the stability variables, methane yield, or kinetics parameters studied.  相似文献   

2.
The combustion of two kinds of biomass and sewage sludge was studied. The biomass fuels were wood biomass (pellets) and agriculture biomass (oat). The sewage sludge came from waste water treatment plant. The biomass and sludge percentage in blends with coal were 10 %. The studied materials were characterised in terms of their proximate and ultimate analysis and calorific value. The composition of the ash of the studied fuels was also carried out. The behaviour of studied fuels was investigated by thermogravimetric analysis (TG, DTG and DTA). The samples were heated from an ambient temperature up to 1,000 °C at a constant three rates: 10, 40 and 100 °C min?1 in 40 mL min?1 air flow. TG, DTG and DTA analysis showed differences between coal, biomass fuels and sewage sludge. 10 % addition of studied fuels to the mixture with coal changed its combustion profile in the case of sewage sludge addition. The combustion characteristics of fuel mixtures showed, respectively, qualitative summarise behaviour based on single fuels. Evolved gaseous products from the decomposition of studied samples were identified. This study showed that thermogravimetric analysis connected with mass spectrometry is useful techniques to investigate the combustion and co-combustion of biomass fuels, and sewage sludge, together with coal. Non-isothermal kinetic analysis was used to evaluate the Arrhenius activation energy and the pre-exponential factor. The kinetic parameters were calculated using Kissinger–Akahira–Sunose model.  相似文献   

3.
《Analytical letters》2012,45(17):2493-2507
In this work, an improved hydride-generation atomic fluorescence spectrometry (HG-AFS) method for the determination of total arsenic (As) in wastewater and sewage sludge samples was applied. The samples were digested completely with mixtures of HNO3 and HClO4. Analytical conditions were studied and optimized through uniform experimental design U*10(108) combined with a single factor test. A mathematical model was established, and a quadratic polynomial stepwise regression analysis by using the DPS software was employed to obtain the factors that impact the fluorescence intensity. This technique is then combined with a single factor test. The optimized experimental conditions were obtained as follows: PMT voltage was 305 V, lamp current was 70 mA, KBH4 concentration was 2.0% (m/v), carrier liquid (HCl) concentration was 5% (v/v), carrier gas (Ar) flow rate was 300 mL min?1, and reaction acidity was 10% (v/v) HCl. The pre-reduction of all forms of As to As(III) was performed by using a mixed solution of 1% thiourea and 1% ascorbic acid. The content of total As was determined under the optimized experimental conditions. The detection limits for total As in wastewater and sewage sludge were 0.09 µg L?1 and 0.01 mg kg?1, respectively. The linear ranges were 0.24–100 µg L?1, and the recovery was 91.0–102.0%. The relative standard deviation (RSD, n = 5) for eleven replicate measurements of the certified reference materials containing 60.6 ± 4.2 µg L?1 As (certified sample of water) and 10.7 ± 0.8 mg kg?1 As (certified sample of soil) were 3.1% and 1.6%, respectively. The proposed method was validated by the analysis of certified reference materials and was successfully applied to the determination of total As in real samples of wastewater and sewage sludge with satisfactory results.  相似文献   

4.
In order to evaluate the slurry nebulisation method as an alternative method for analysis of sewage sludge, the metal content of sludge samples of different origins was determined. The concentrations of six elements: Cd, Cr, Cu, Ni, Pb, and Zn were determined by introducing the sludge as a slurry into an inductively coupled plasma optical emission spectrometer (ICP-OES). Calibration was performed by using aqueous standard solutions. For comparison, the sewage sludge was also digested by microwave digestion and introduced into the plasma as an aqueous solution. The accuracy of the method was checked by analysing a sewage sludge certified reference material (CRM 007-040 Sewage Sludge). The Student's t-test showed that values obtained using slurry nebulisation were close to the certified values at a 95% confidence level. The values of elements Cd 11.1?±?0.8; Cr 37.7?±?3.3; Cu 563.3?±?38.4; Pb 119.2?±?10.1; Zn 729?±?68.2?mg?kg?1 obtained using this method were comparable with those obtained using the conventional method. The slurry method can, therefore, be successfully applied to the determination of content of each element in sewage sludge with RSD less than 3%, without the need to predissolve them. This could avoid the use of hazardous chemicals, incomplete dissolution and loss of volatile analytes.  相似文献   

5.
In this study, we aimed at optimizing a sensitive and reliable method for a simultaneous determination of 31 pharmaceuticals belonging to predominant therapeutic classes identified in different types of sewage sludge proceeding from conventional and advanced wastewater treatment. Freeze-dried sewage sludge was extracted by pressurized liquid extraction technique using accelerated solvent extractor Dionex 300. In order to minimize interferences with matrix components and to preconcentrate target analytes, solid phase extraction was introduced in the method as a clean-up step. The entire method was validated for linearity, precision, accuracy, and method detection limits (MDLs). The method turned out to be specific, sensitive, and reliable for the analysis of sludge of different composition, type, and retention time in the process. The developed sample preparation protocol and previously published method for LC-MS/MS analysis (Gros et al., Talanta 70:678–690, 2006) were successfully applied to monitor the target pharmaceuticals in different types of sewage sludge, i.e., primary sludge, secondary sludge, treated sludge, and sludge proceeding from pilot-scale membrane bioreactors (MBRs) operating in parallel to the conventional activated sludge treatment. Among the investigated pharmaceuticals, 20 were detected in the sludge proceeding from full-scale installations, whereas the MBR sludge concentrations were below MDLs for several compounds. The highest concentrations were recorded for treated and primary sludge. For example, the mean concentration of ibuprofen in the digested sludge was 299.3?±?70.9 ng g?1 dw, whereas in the primary sludge, it was enriched up to 741.1 ng g?1 dw. Other pharmaceuticals detected at relatively high concentrations were diclofenac, erythromycin, glibenclamide, ketoprofen, ofloxacin, azithromycin (up to 380.7, 164.2, 190.7, 336.3, 454.7, 299.6 ng g?1 dw in the primary sludge, respectively), gemfibrozil, loratidine, and fluoxetine (up to 189.1, 189.7 and 174.1 ng g?1 dw in the treated sludge, respectively).  相似文献   

6.
《Analytical letters》2012,45(4):570-581
Two simple, sensitive, and specific high-performance liquid chromatography and thin-layer chromatography methods were developed for the simultaneous estimation of Amlodipine besilate (AM) and Valsartan (VL). Separation by HPLC was achieved using a xTerra C18 column and methanol /acetonitrile /water/ 0.05% triethylamine in a ratio 40:20:30:10 by volume as mobile phase, pH was adjusted to 3 ± 0.1 with o-phosphoric acid. The flow rate was 1.2 mL min?1. The linearity range was 0.2 to 2 µg mL?1 for amlodipine besilate and 0.4 to 4 µg mL?1 for Valsartan with a mean percentage recovery of 99.59 ± 0.523% and 100.61 ± 0.400% for amlodipine besilate and valsartan, respectively. The TLC method used silica gel 60 F254 plates; the optimized mobile phase was ethyl acetate/ methanol / ammonium hydroxide (55:45:5 by volume). Quantitatively, the spots were scanned densitometrically at 237 nm. The range was 0.5–4.0 µg spot?1 for amlodipine besilate and 2.0–12.0 µg spot?1 for valsartan. The mean percentages recovery was 99.80 ± 0.451% and 100.61 ± 0.363% for amlodipine besilate and valsartan, respectively. The HPLC method was found to be simple, selective, precise, and reproducible for the estimation of both drugs from spiked human plasma.  相似文献   

7.
The effect of microwave pre-treatment (MwP) on anaerobic digestion of sewage sludge was studied by means of thermal analysis and evolved gas analysis. The effect of the pre-treatment at low energy input (<1000 kJ L?1) on sludge solubilisation was studied with the aid of response surface methodology. The pre-treatment process was subsequently studied at energies of 488–2700 kJ L?1 to evaluate the improvement in biogas production under mesophilic conditions. Organic matter modifications were studied using a Setaram TGA92 analyser at atmospheric pressure coupled to an MSC200 quadrupole mass spectrometer from Balzers. Particle size analysis was carried out using a Laser Diffraction Particle Size Analyser LS 13 320 Beckmann Coulter for evaluating the effect of MwP on sludge particles. Results showed an increase in organic matter solubilisation with the increase in the energy applied. Modifications in the specific surface area of the organic matter due to the MwP resulted in increments in methane yields. However, an accumulation of complex compounds was observed in thermal profiles at the maximum energy input (2700 kJ L?1). Semi-continuous digestion experiments were evaluated using as substrate pre-treated sludge at the optimum energy value (975 kJ L?1). Results showed a significant increase in methane yield (43 %) when evaluating the process at hydraulic retention times (HRTs) of 25–10 days.  相似文献   

8.
In this paper we describe an environmentally friendly and sensitive method for the determination of ten primary amines in sewage sludge. The method is based on pressurised hot water extraction (PHWE) followed by simultaneous derivatization with pentafluorobenzaldehyde (PFBAY) and headspace solid-phase microextraction (HS-SPME) and subsequent gas-chromatography ion-trap tandem mass spectrometry (GC-IT-MS-MS) analysis. The influence of the main factors on the PHWE of sludge was optimized by a central composite design. For all species the optimal conditions were water at pH 4 as the extracting solvent, an extraction temperature of 100 °C and an extraction time of 15 min. The separation and detection of the ten amines by GC-IT-MS-MS took just 10 min and the entire process took approximately 1 h. Repeatability and reproducibility between days, expressed as RSD (%) (n = 5), were less than 19 and 24%, respectively. The average limit of detection (LOD) was of 65 μg kg−1 s (range found 9-135) and the average limit of quantification (LOQ) was of 230 μg kg−1 (range found 50-450) of dry weight (d.w.). Under optimized conditions we used this method to determine the compounds in industrial and municipal sewage sludge samples and in sludge from a potable water treatment plant. Methylamine and isobutylamine showed the highest levels in one of the industrial sewage sludge samples (404 and 543 mg kg−1 (d.w.), respectively). To our knowledge, this paper presents for the first time the determination of ten primary amines in sewage sludge samples using PHWE.  相似文献   

9.
Activated sewage sludge samples obtained from two different waste water treatment plants were investigated by thermogravimetric analysis. Due to a very high content of water in the sludge samples, these had to be dried at 160°C in an electrical oven in order to remove all adsorbed water. To ensure pyrolysis conditions, nitrogen atmosphere was applied. The pyrolysis decomposition process was carried out in the temperature range from ambient temperature to 900°C at three different heating rates: 2 K min−1, 5 K min−1, 10 K min−1. TGA and DTG curves of the decomposition processes were obtained. Temperature of onset decomposition, final temperature of decomposition, maximum decomposition rate, and decomposition temperature were determined by thermogravimetric analysis for both sludge samples used. The main decomposition process takes place at temperatures in the range from 230°C to 500°C. Above this temperature, there are only small changes in the mass loss which are often attributed to the decomposition of carbonates present in the sewage sludge samples. To determine the apparent kinetic parameters such as the activation energy and the preexponential factor, the so called Friedman isoconversional method was used. Because of the requirements of this method, initial and final parts of the decomposition process, where crossings of the decomposition lines occurred, were cut off. Obtained dependencies of the apparent activation energies and preexponential factors as a function of conversion were used backwards to calculate the modeled decomposition process of sewage sludge and the experimental data were in good accordance with the data obtained by simulation.  相似文献   

10.
This study proposes a microwave-assisted method for the simultaneous extraction of highly prescribed antidepressants (citalopram, venlafaxine, fluoxetine, sertraline and amitriptyline) and caffeine from sediments and sewage sludge for subsequent HPLC-PDA analysis. Because the sludge and sediment matrices have high contents of organic material, they strongly interact with the analytes and hinder extraction. Thus, a carefully optimised analytical methodology is required for quantitative extraction. A simplex-centroid design was applied to optimise the solvent composition, and a three-factor central composite rotational design was used to optimise the extraction protocol with regards to pH, amount of solvent and processing time. Samples (in triplicates) were fortified with a standard mixed solution of all the analytes and extracted according to the experimental design in each study. The extraction steps included: 30 s vortexing, 20 s microwave heating at 10 W, cooling to room temperature (25°C) in an ultrasonic bath for 60 s, 2 min centrifugation at 2000 rpm, and filtration. Analysis of variance and lack-of-fit tests were used to assess the significance of data fitting at 95% confidence. The desirability function was the optimisation tool used to obtain the ideal extraction conditions. As a result, a binary mixture of methanol and acetonitrile in 45:55 and 53:47 (v/v) ratios was indicated as the optimum solvent composition for the simultaneous extraction of all the target drugs from the sludge and sediment, respectively. The optimised extraction conditions were: 3 extraction cycles with 4 mL of solvent at pH 3 for sewage sludge extraction and 4 extraction cycles with 3 mL of solvent at pH 11 for sediment extraction. Further, low recoveries were obtained for extractions from sediment as compared to sludge indicating strong interaction of antidepressants and caffeine with the acidic organic components of sediments. It was found that the optimisation of pH of the extraction phase was crucial for the efficient extraction of the analytes from these environmental matrices.  相似文献   

11.
《Analytical letters》2012,45(8):1348-1365
Abstract

A rapid and specific liquid chromatography/tandem mass spectrometry method was described for the simultaneous determination of hydrochlorothiazide and valsartan in human plasma. After extracted from plasma using methanol, hydrochlorothiazide, valsartan and hydroflumethiazide, irbesartan, used as the internal standard, respectively, were chromatographically analyzed on a Phenomenex Kromasil C8 column with water and methanol (27:73, v/v) as the mobile phase. Selected reaction monitoring was specific for mass detection employing negative electrospray ionization. The calibration standards were linear over the concentration range (3.13–800 ng/ml for hydrochlorothiazide and 11.72–3000 ng/ml for valsartan). The method was found to be suitable for application to a pharmacokinetic study after oral administration of dispersible tablet containing 12.5 mg hydrochlorothiazide and 80 mg valsartan to 20 healthy volunteers.  相似文献   

12.
A simple, isocratic, stability-indicating liquid chromatographic method for quantitative determination of curcumin was successfully developed. The chromatographic separations were achieved using a Hi-Q-Sil C18; 4.6 mm × 250 mm and 10 μm particle size column employing acetonitrile and acetate buffer (pH 3.0; 60: 40, v/v) as the mobile phase. The analyte was subjected to acidic, basic, oxidative, thermal and photo degradation. The method was validated with respect to linearity, precision, accuracy, limit of detection and limit of quantification. Curcumin was detected by UV-Vis detector at 425 nm whereas the degradation products were detected at 280 nm. The method was linear over the concentration range of 1–10 μg mL?1. The limit of detection was found to be 0.06 μg mL?1 and the quantification limit was 0.21 μg mL?1. Considerable degradation of the analyte was observed when it was subjected to alkaline conditions. Accuracy, evaluated as recovery, was in the range of 97–103%. Intra-day precision and intermediate precision showed relative standard deviations <1% and <2% respectively.  相似文献   

13.
By empirically examining the persistent theme, we hope to produce a more complete understanding of methods for determination of volatile methylsiloxanes in biogas stream. Therefore, we made an attempt to investigate a rapid and sensitive method for simultaneous analysis of linear and cyclic volatile methylsiloxanes in sewage biogas in the context of the perspective for application in online systems. The gas chromatographic (GC) parameters were optimised, and sampling of volatile methylsiloxanes from biogas was performed using novel direct sampling procedure with applying of three kinds of liquid-media. Through application of well-established gas chromatography technique coupled with two types of detector – flamed ionisation detector and mass spectrometer detector – we developed the characterisation of the presented methods. Moreover, during the samples preparation the extraction procedure was consistently excluded, as well as the time of analysis was significantly reduced. The analyses were carried out by applying special constructed sampling train where the absorbed VMSs were trapped and analysed directly by GC technique, afterwards. The instrumental analytical protocol was found to yield a linear calibration in the range 0.1–55.13 (µg g?1) with R2 values 0.996 and in the range from 0.1 to 65.17 µg g?1) with R2 values > 0.99 for GC-FID and GC-MS method respectively. In all analysed samples linear and cyclic VMSs were found in sewage gas with quantities exceeding 4.6 mg Nm?3 and 19.9 mg Nm?3, respectively Furthermore, estimation of VMSs solvent absorption efficiency was tested and the highest absorption efficiency was obtained when acetone was used as a primary solvent. High range of linearity (0.1–65.17 µg/g), and low values of limit of detection (0.01 µg/g), limit of quantification (0.04 µg/g) clearly indicate that the analysis can be successfully repeated in other independent laboratory. The proposed method creates the real perspective for analyis of VMSs in on-line system.  相似文献   

14.
A simple, sensitive and reliable method for the rapid determination of hyponitrite and hyponitrate (Angeli’s salt) in alkaline media, is presented where both species are relatively stable. The method is based on the separation of the two anions by an anion exchange column and thereafter UV spectrophotometric detection at 248 nm. The calibration curves were linear over the concentration range of 0.4–100 mg L?1, whereas the detection limit was found to be 50 μg L?1 for hyponitrite and 100 μg L?1 for hyponitrate. Under these conditions, the determination of nitrate and nitrite is also possible.  相似文献   

15.
In this paper, novel low-cost oxygen carriers containing Fe2O3 are evaluated for use in chemical looping combustion. Sewage sludge ashes and reference samples were prepared and used in cyclic reduction and oxidation experiments in a thermogravimetric analyzer (TG). A gaseous (3 % H2) fuel and a solid fuel (hard coal) were tested. Three-cycle CLC tests were carried out in the 600–800 °C temperature range and long-term testing was performed at 950 °C. A reactivity study showed that the natural sewage sludge ash sample was stable during the cycling TG tests when hydrogen was used as a fuel at all of the temperatures investigated. Strong temperature effects on the oxygen transport capacity were observed. An one-cycle test at 900 °C showed also that the sewage sludge ash successfully reacted with coal. The oxygen released was fully used for coal combustion, with appreciable reaction rate at temperature of ~750–800 °C, that is significantly lower than that obtained for pure Fe2O3-based oxygen carrier. The oxidation reaction was much faster than the reduction reaction. Moreover, the sewage sludge ash showed a low tendency toward agglomeration in the cyclic test, which was superior to the behavior of synthetic materials. The sewage sludge ash exhibited also high mechanical strength, an attrition index of 1 % and a high-temperature resistance of 1,170 °C in a reducing atmosphere. We conclude that sewage sludge ash can be effectively used as a low-cost, valuable oxygen carrier in practical application in chemical looping combustion technology for power generation.  相似文献   

16.
A sensitive, precise and simple LC method for the simultaneous quantification of aliskiren, valsartan and sitagliptin in rat plasma has been developed and validated. The chromatographic separation was achieved on a C18 column (250 mm × 4.6 mm, 5 μm) maintained at room temperature, using isocratic elution with acetonitrile/20 mM ammonium acetate buffer (35:65, v/v), pH adjusted to 4.85 with glacial acetic acid, and detected using a fluorescence detector. Liquid–liquid extraction of the aliskiren, valsartan and sitagliptin from the rat plasma with t-butyl methyl ether resulted in their high recoveries. LC calibration curves based on the extracts from the rat plasma were linear in the range of 25–2,000 ng mL?1 for aliskiren and sitagliptin and 50–4,000 ng mL?1 for valsartan. The limits of quantification were 25 ng mL?1 for aliskiren and sitagliptin and 50 ng mL?1 for valsartan. The precision and accuracy of the method were well within the generally accepted criteria for biomedical analysis. The described method was successfully applied to study the pharmacokinetics of aliskiren, valsartan and sitagliptin following oral administration, individually as well as in combination in Sprague–Dawley rats. The results of the study implied the occurrence of pharmacokinetic interaction upon the co-administration of these three drugs.  相似文献   

17.
Resource utilization is a critical pathway for sustainable solid waste treatment. Biochar was prepared from the co-pyrolysis of sewage sludge and tea waste. Brunauer–Emmett–Teller measurement, scanning electron microscopy and Fourier transform infrared analysis were employed to characterize the biochar. Then, the interface behavior between biochar and Cd from aqueous solution was investigated. The effect of adsorbent dose and pH on Cd adsorption was evaluated. Adsorption kinetics and the adsorption isotherm were studied, and the adsorption mechanism was explored. The results showed that the suitable adsorbent dose was 4 g L?1 and the optimal pH of the Cd solution remained at 6.0. Cadmium sorption on the biochar could be well described by the pseudo-second order kinetic model (R 2 > 0.98). The adsorption process was described using the Langmuir (R 2 > 0.86), Freundlich (R 2 > 0.86), Temkin (R 2 > 0.84) and Dubinin–Radushkevich (R 2 > 0.86) isotherm models. The proportion of organic constituents in biochar was 69.2–72.4%. Minerals that originated in biochar played an important role during the Cd adsorption process, and the contribution of minerals accounted for 27.6–30.8% of the total adsorption. The main mechanism of the Cd adsorption process by biochar involved ion exchange, surface complexation, electrostatic interaction, surface co-precipitation, and other mechanisms. Therefore, biochar created by the co-pyrolysis of sewage sludge and tea waste could be used as an adsorbent for the removal of metal ions from contaminated water.  相似文献   

18.
A new, sensitive and stability indicating liquid chromatographic method has been developed for the determination of imatinib mesylate (IM). Efficient chromatographic separation was achieved using a C18 column with simple mobile phase combination delivered in an isocratic mode and quantitation was carried out using ultraviolet detection. For the first time, a novel microwave assisted degradation procedure was employed for stress testing studies. In addition, orthogonal separation technique was applied to demonstrate selectivity of the proposed method. The method has demonstrated excellent linearity over the range of 25–1,600 ng mL?1. Moreover, the method was found to be sensitive with a low limit of detection (3.35 ng mL?1) and limit of quantitation (10.16 ng mL?1). The method has shown good and consistent recoveries (99.35–100.69%) with low intra- and inter-day relative standard deviation (RSD) (<2.5%). Experimental design confirmed that peak area was unaffected by small changes in critical factors, in robustness study. The validated method was successfully applied for determination of IM in pharmaceutical formulations.  相似文献   

19.
The imposition of more stringent legislation by CETESB in the State of São Paulo (Brazil) governing the disposal and utilization of sewage sludge, coupled with the growth in its generation has prompted a drive for alternative uses of sewage sludge. One option that is especially promising, due to its potential to valorize sludge, is its conversion into carbonaceous adsorbents or coke for industrial effluents treatment. Thus, a methodology is presented to estimate the coke produced from the sludge of a sewage treatment station using thermal analysis. The used sewage sludge, which comes from aerobic treatment, was collected in the wastewater treatment station of Barueri, one of the largest of the São Paulo metropolitan area. The sludge samples were collected, dried, ground, and milled until they passed an ABNT 200 sieve. The inert ambient used during its thermal treatment produces inorganic matter and coke as residual materials. Coke formation occurs in the 200–500 °C range and, between 500 and 900 °C, its thermal decomposition occurs. The highest formation of coke occurs at 500 °C.  相似文献   

20.
One-stage autothermal thermophilic aerobic digestion (ATAD) is effective for the reduction of volatile solids (VSs) and pathogen in sewage sludges. A novel process of combining mesophilic (<35 °C) anaerobic digestion with a thermophilic (55 °C) aerobic digestion process (AN/TAD) occurred in a one-stage digester, which was designed for aeration energy savings. The efficiency of sludge degradation and variation of sludge properties by batch experiments were evaluated for the AN/TAD digester with an effective volume of 23 L for 30 days compared with conventional thermophilic aerobic digestion (TAD). The AN/TAD system can efficiently achieve sludge stabilization on the 16th day with a VS removal rate of 38.1 %. The AN/TAD system was operated at lower ORP values in a digestion period with higher contents of total organic compounds, volatile fatty acids, protein, and polysaccharide in the soluble phase than those of the TAD system, which can rapidly decreased and had low values in the late period of digestion for the AN/TAD system. In the AN/TAD system, intracellular substances had lysis because of initial hydrolytic acidification.  相似文献   