首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
A method is presented for magnetic solid phase extraction (MSPE) of tetracyclines in milk samples. The method involves the extraction and clean-up by silica based magnetic support dispersion on non-pretreated milk samples, followed by the magnetic isolation and desorption of the analytes by acidified methanol. The tetracyclines eluted from the magnetic support were determined simultaneously by flow injection analysis with spectrophotometric detection. Under optimal conditions, the linear range of the calibration curve ranges from 0.03 to 0.60 mg L?1, with a limit of detection of 10 μg L?1. Recoveries were determined for milk spiked at levels from 0.15 to 0.60 mg L?1. Average recoveries ranged from 91.0 to 97.0%, with a precision of <5.0% in all cases. The method was validated by comparing the results with those obtained by MSPE-HPLC and SPE-HPLC. No significant differences were observed (p?<?0.05)  相似文献   

2.
A modified SBA-15 mesoporous silica was developed, as an adsorbent, for the removal of Cr(VI) ions from natural-water samples. The effects of experimental parameters, including pH of solution, sample and eluent flow rate, the eluent composition, the eluent volume, and the effect of coexisting ions on the separation and determination of Cr(VI), were investigated. It was shown that Cr(VI) was selectively adsorbed from aqueous solution at pH 3, but Cr(III) could be adsorbed from solution at alkaline pH range. The retained Cr(VI) was eluted with 0.5?mol?L?1 KCl solution in 0.1?mol?L?1 Na2CO3 subsequently. Under the optimum conditions, the modified mesoporous silica (py-SBA-15) with a high pore diameter exhibited an adsorption capacity of 136?mg?g?1 and a lower limit of detection than 2.3?µg?L?1 by using diphenylcarbazide as a chromophorous reagent for the determination of Cr(VI) ions. A preconcentration factor as high as 200 was calculated for Cr(VI). The loaded py-SBA-15 can be reactivated with recovery of more than 98.5% over at least eight cycles. The relative standard deviation (RSD) for Cr(VI) ion recovery was less than 1.8%. Validation of the outlined method was performed by analysing a certified reference material (BCR 544). The proposed method was applied to determine Cr(VI) value in natural and waste water samples successfully.  相似文献   

3.
A novel liquid–liquid–solid microextraction (LLSME) technique based on porous membrane-protected molecularly imprinted polymer (MIP)-coated silica fiber has been developed. In this technique, a MIP-coated silica fiber was protected with a length of porous polypropylene hollow fiber membrane which was filled with water-immiscible organic phase. Subsequently the whole device was immersed into aqueous sample for extraction. The LLSME technique was a three-phase microextraction approach. The target analytes were firstly extracted from the aqueous sample through a few microliters of organic phase residing in the pores and lumen of the membrane, and were then finally extracted onto the MIP fiber. A terbutylazine MIP-coated silica fiber was adopted as an example to demonstrate the feasibility of the novel LLSME method. The extraction parameters such as the organic solvent, extraction and desorption time were investigated. Comparison of the LLSME technique was made with molecularly imprinted polymer based solid-phase microextraction (MIP-SPME) and hollow fiber membrane-based liquid-phase microextraction (HF-LPME), respectively. The LLSME, integrating the advantages of high selectivity of MIP-SPME and enrichment and sample cleanup capability of the HF-LPME into a single device, is a promising sample preparation method for complex samples. Moreover, the new technique overcomes the problem of disturbance from water when the MIP-SPME fiber was exposed directly to aqueous samples. Applications to analysis of triazine herbicides in sludge water, watermelon, milk and urine samples were evaluated to access the real sample application of the LLSME method by coupling with high-performance liquid chromatography (HPLC). Low limits of detection (0.006–0.02 μg L−1), satisfactory recoveries and good repeatability for real sample (RSD 1.2–9.6%, n = 5) were obtained. The method was demonstrated to be a fast, selective and sensitive pretreatment method for trace analysis of triazines in complex aqueous samples.  相似文献   

4.
A rapid and automated method was developed for the determination of bacterial contamination and using Escherichia coli as a model microorganism. The method involves the use of a sensor connected to a flow injection (FI) system. The sample is introduced through a flow injection system into a piezoelectric quartz crystal (PQC) flow-cell. The resulting change of the resonance frequency is related to the bacterial contamination in the sample. The parameters associated with the flow system and the conditions for introducing the sample culture were optimized. Calibration curves are linear in the range from 3.2?×?107 to 3.2?×?109 cfu per mL-1, with a correlation coefficient of 0.997. The reproducibility was between 3.1 and 7.6%, and the detection limit is 1.1?×?107 cfu per mL-1. The method allowed the determination of bacterial contamination in residual water and in samples of milk and chicken stock within 5 h, while the conventional plate count method requires 24 to 48 h. The results obtained by these two methods are in good agreement.
Figure
A rapid and automated method for the determination of bacterial growth contamination is proposed and Escherichia coli was used as a model microorganism. The methodology involves the use of a piezoelectric quartz crystal (PQC) sensor connected to a flow injection (FI) system. The sample was introduced through the FI system and the resonant frequency change of PQC is related to the bacterial contamination in the sample. The method allows the successful determination of bacteria in residual water and several food samples  相似文献   

5.
A fast multi-residue method based on dispersive solid-phase extraction (DSPE) followed by liquid chromatography–tandem mass spectrometry was developed for the simultaneous determination of 44 pesticides in raw bovine milk. Raw bovine milk samples did not percolate through SPE cartridges usually applied for pesticide extraction from homogenized pasteurized milk samples. Therefore, a DSPE technique was implemented and validated for the first time in this work. Graphitized non-porous carbon and C18 modified silica materials were tested both in combination with magnesium sulfate and bonded silica with ethylenediamine-N-propyl phase. The efficiency of the DSPE process was studied at several concentration levels obtaining the higher recoveries with C18 material. The method performance was also assessed and the limits of quantification reached the ng g−1 level, complying with the most recent maximum residue levels. The DSPE method was also shown to be suited to both the fatty and skimmed fractions issued from raw milk. Finally, the extraction method was successfully applied to the analysis of raw milk samples collected in 23 farms of dairy cattle from NW Spain (Galicia).  相似文献   

6.
A novel and simple method is proposed for the determination of tetracycline by adsorptive voltammetry in a droplet using a carbon nanotube paste rotating disk electrode (CNTP-RDE). An enhanced electrochemical oxidation response of tetracycline was observed in pH 8.2 supporting electrolyte by the addition of a long-chain cationic surfactant, such as benzyldimethyltetradecylammonium chloride (zephiramine). Under the optimized experimental conditions, the calibration curve was linear across a tetracycline concentration range from 1.0?×?10?7 to 2.0?×?10?6 M. The limit of detection and sensitivity were 4.0?×?10?8 M and 0.9358?A M?1, respectively. This method was successfully employed for the determination of tetracycline in milk samples.  相似文献   

7.
A magnetic solid phase extraction method coupled to capillary electrophoresis is proposed for the determination of tetracycline, oxytetracycline, chlortetracycline and doxycycline in milk samples. Five different magnetic phenyl silica adsorbents covered with magnetite were synthesized by varying the molar ratio of phenyltrimethylsilane and tetramethylorthosilicate; these adsorbents were evaluated in terms of their pH and degree of hydrophobicity for tetracycline retention. The optimal, selected combination of conditions was a pH of 10.0 and a magnetic sorbent ratio of 4:1; under these conditions, the retention capacity ranged from 99.7% to 101.2% for the four tetracyclines analyzed. The elution conditions and initial sample volume of the proposed extraction method were also optimized, and the best results were obtained with 1×10(-3) M acetic acid in methanol as eluent and a 200 ml of sample volume. Under optimal conditions, average recoveries ranged from 94.2% to 99.8% and the limits of detection ranged from 2 to 9 μg l(-1) for the four tetracyclines. After the proposed method was optimized and validated, 25 milk samples of different brands were analyzed, oxytetracycline residues were detected in five samples, in concentrations ranging from 98 to 213 μg l(-1). Subsequent analysis of positive samples by SPE-CE and magnetic solid phase extraction-HPLC revealed than no significant differences were found from results obtained by the proposed methodology. Thus, the developed magnetic extraction is a robust pre-concentration technique that can be coupled to other analytical methods for the quantitative determination of tetracyclines.  相似文献   

8.
A simple method for the determination of90Sr by using thin layer chromatography on silica gel or cellulose pretreated with calcium oxalate is proposed. In these conditions a complete separation between strontium and its daughter yttrium is obtained. Radioactivity of separated elements was measured by a linear multiscanner analyzer and the results were computer processed to obtain the activity of90Sr. The method has been applied to samples of water and milk subjected to a very simple extraction procedure. Under the experimental conditions used, the detection limit is about 25 mBq of deposited radioactivity, which corresponds to about 6 Bq/l.  相似文献   

9.
A sensitive and selective microwave-assisted solid phase extraction procedure coupled to inductively coupled plasma-mass spectrometry (ICP-MS) is proposed for palladium (Pd) and platinum (Pt) quantification in environmental and biological samples. Pd and Pt were quantitatively retained on commercial thioureido propyl functionalised silica gel packed inside a home-made glass microcolumn, and later eluted with 0.5% thiourea solution under microwave irradiation, followed by ICP-MS determination. The main variables affecting the procedural stages (i.e., sorption and desorption) and ICP-MS determination were optimised. The best conditions found were: (a) sorption: sample acidity, 1?M HCl; sample flow rate, 3?mL?min?1; (b) desorption: microwave radiation, power 800?W; eluent concentration, 0.5% thiourea; eluent flow rate, 0.5?mL?min?1; (c) ICP-MS determination: nebuliser feeding, free aspiration (0.3?mL?min?1); internal standard, Rh (5?µg?L?1). Analyte recoveries were higher than 90% and concentration factors up to 90 and 92 were achieved for Pd and Pt, respectively. Depending on the conditions, the methodological limits of detection were down to 0.2?ng?L?1 for both analytes and repeatability, expressed as RSD%, varied between 1.3 and 11.0%. A method selectivity evaluation showed that most of the ICP-MS interferents were either quantitatively separated or more than 86% eliminated, except for Cu (elimination efficiency around 30%). Finally, the method was successfully used to determine Pd in certified reference materials (i.e. human urine and serum) and Pd and Pt in PM10 airborne particulate matter fractions.  相似文献   

10.
Natalia Campillo 《Talanta》2010,80(5):1856-1861
A method based on solid-phase microextraction (SPME) followed by gas chromatography with microwave-induced plasma atomic emission detection for determining dimethylselenide (DMSe) and dimethyldiselenide (DMDSe) in milk and milk by-products is proposed. Parameters affecting the SPME, such as sample volume or mass, ionic strength, adsorption and desorption times and temperatures were optimized in the headspace mode. The matrix effect was evaluated for the different samples studied, concluding that standard additions calibration was required for quantification purposes. The detection limits ranged from 70 to 110 pg mL−1 for DMSe and from 80 to 400 pg mL−1 for DMDSe, depending on the sample under analysis. None of the twenty-three samples analyzed contained the studied compounds at concentrations above the corresponding detection limits.  相似文献   

11.
Organophosphate esters, widely used as flame retardants and plasticizers, are regarded as a class of emerging pollutants. In this work, a novel approach was developed for the fabrication of a solid‐phase microextraction fiber by using hybrid silica‐based materials with immobilized ionic liquids with sol–gel technology, and the prepared solid‐phase microextraction fiber was then coupled with gas chromatography and flame photometric detection for the analysis of six organophosphate esters. The high loading of 1‐hexadecyl‐3‐methylimidazolium bis(trifluoromethylsulfonyl)imide was confined within the hybrid network. The developed solid‐phase microextraction fiber possesses a coating thickness of ~35 μm with good thermal stability and long lifetime. The parameters affecting the extraction efficiency such as extraction time, temperature, pH, and ionic strength of the sample solution were optimized. Under the optimized conditions, the limits of detection were in the range of 0.04?0.95 μg L?1, and the precision of the method assessed with repeatability and reproducibility of (RSD%) ?13 and ?29%, respectively. The proposed method was successfully applied to determine the six organophosphate esters in three real water samples, with recoveries in the range of 64.8?125.4% at two different spiking concentration levels. As a result, the proposed method demonstrated its potential for application in trace determination of organophosphate esters in actual water samples.  相似文献   

12.
A new molecularly imprinted polymer modified with restricted access material (a hydrophilic external layer), (MIP-RAM) was synthesized via polymerization in situ in an open fused silica capillary. This stationary phase was used as sorbent for in-tube solid phase microextraction (in-tube SPME) to determine parabens in breast milk samples by ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Scanning electron micrographs (SEM) illustrate MIP surface modification after glycerol dimethacrylate (hydrophilic monomer) incorporation. The interaction between parabens and MIP-RAM was investigated by Fourier-transform infrared (FTIR) spectroscopy. The Scatchard plot for MIP-RAM presented two linear parts with different slopes, illustrating binding sites with high- and low-affinity. Endogenous compounds exclusion from the MIP-RAM capillary was demonstrated by in-tube SPME/LC-UV assays carried out with blank milk samples. The in-tube SPME/UHPLC-MS/MS method presented linear range from 10 ng mL−1 (LLOQ) to 400 ng mL−1 with coefficients of determination higher than 0.99, inter-assay precision with coefficient of variation (CV) values ranging from 2 to 15%, and inter-assay accuracy with relative standard deviation (RSD) values ranging from −1% to 19%. Analytical validation parameters attested that in-tube SPME/UHPLC-MS/MS is an appropriate method to determine parabens in human milk samples to assess human exposure to these compounds. Analysis of breast milk samples from lactating women demonstrated that the proposed method is effective.  相似文献   

13.
We have developed a technique for the solid-phase extraction of gold using various kinds of pyridine-functionalized nanoporous silica prior to its determination in various samples using FAAS. The effects of solution pH, sample and eluent flow rate, sample volume and of potentially interfering ions are compared. The limits of detections vary from 28 to 53?pg?mL?1. The accuracy and precision are between 99.8% and 98.3?% and 0.7 to 1.6?% (RSD), respectively. The method was successfully applied to several standard reference materials.
Figure
A technique has been developed for the solid-phase extraction of gold using various kinds of pyridine-functionalized nanoporous silica prior to its determination in various samples using FAAS.  相似文献   

14.
A new ionic liquid modified silica gel sorbent was prepared from the reaction of active silica gel with N-3-(-3-triethoxysilylepropyl)-3-methylimidazolium chloride ([(TESP)MIm]Cl). This sorbent was exploited as solid phase extractant for separation and preconcentration of metal ions prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). It was found that it can selectively adsorb Fe(Ш). Identification of the surface modification was performed on the basis of FT-IR. Experimental conditions for effective adsorption of trace Fe(Ш) were optimised using both batch and column procedures. At pH 3, Fe(Ш) could be quantitatively adsorbed and completely eluted by using 2?mL of 0.1?mol?L?1 of HCl. 150?mL of sample solution was adopted as the maximum sample volume and a high enrichment factor of 75 was obtained. Most common coexisting ions did not interfere with the separation and preconcentration of Fe(Ш) at optimal conditions. The maximum static adsorption capacity of the sorbent was 37.0?mg?g?1. The detection limit of the present method was 0.48?µg?L?1, and the relative standard deviation (R. S. D.) was lower than 1.7%. The method was successfully applied to the preconcentration of trace Fe(Ш) in biological and natural water samples with satisfactory results.  相似文献   

15.
A highly sensitive procedure has been developed for total arsenic and antimony determination in milk samples by hydride generation atomic fluorescence spectrometry after microwave-assisted sample digestion. The discrete introduction of 2 ml of digested sample in the automated continuous flow hydride generation system allows us to reduce drastically the sample and HCl consume and to determine several elements from a same sample digestion. The method provides detection limits of 0.006 and 0.003 ng ml−1, a sensitivity of 2390 and 2840 fluorescence units per ng ml−1 for As and Sb respectively, and average relative standard deviation of 2.3% for As and 4.8% for Sb. The analysis of cow milk samples, obtained from the Spanish market evidenced the presence of As at concentration levels from 3.4 to 11.6 ng g−1 and Sb levels from 3.5 to 11.9 ng g−1, thus in a proportion near to 1:1, which is in contrast with the 10:1 natural ratio between As and Sb and could evidence the effect of the introduction of new alloys and polymer materials in the industrial process of milk. The method was validated by the comparison of data found for commercial samples by using the proposed procedure and reference methods based on dry-ashing and AFS, and microwave-assisted digestion and inductively coupled plasma mass spectrometry determination.  相似文献   

16.
A liquid chromatographic method for the determination of closantel residues in milk and tissues is developed and validated. An acetonitrile-acetone solution (80:20, v/v) is used for the extraction of closantel residues from milk and animal tissues, and the extract is purified by solid-phase extraction with Oasis MAX cartridges and a mixture of formic acid-acetonitrile (5:95, v/v) as the elution solution. A C(18) bonded silica column is used for chromatographic separation. The mobile phase consists of acetonitrile-water (85:15, v/v) containing 0.05% triethylamine at pH 2.5, adjusted with phosphoric acid with the flow-rate set at 1.0 mL/min. Using the fluorescence emission of closantel at lambda(ex) = 335 nm and lambda(ex) = 510 nm, the calibration curve is linear, with a correlation coefficient of 0.9999 over the concentration range of 10-5000 microg/kg for the tissue sample and 10-5000 microg/L for the milk sample. The detection limit (s/n = 3) is 3 microg/kg for tissue sample and 3 microg/L for milk sample. The intra- and inter-day repeatabilities are between 3.35-7.66% and 4.04-8.67%, respectively. The proposed method enables the quantitative determination of closantel residues at levels as low as 10 microg/kg in animal tissue samples and 10 microg/L in milk samples.  相似文献   

17.
In the present study, a convenient and sensitive method for determination of six penicillin antibiotics (amoxicillin, ampicillin, penicillin G, oxacillin, cloxacillin, and dicloxacillin) in milk and honey samples was developed. Milk and honey samples were diluted with water, then directly treated by stir bar sorptive extraction based on poly (vinylimidazole‐divinylbenzene) monolithic material as coating. The analytes were analyzed by LC/ESI‐ MS/MS. Several extraction parameters including extraction and desorption time, pH value, and ionic strength in sample matrix were investigated in detail. Under the optimized extraction conditions, the calculated detection limits for the target compounds were as low as 0.23–2.66 ng/kg in milk and 0.18–1.42 ng/kg in honey, respectively. Good linearity was obtained for analytes with the correlation coefficients (R2) above 0.997. Excellent method reproducibility was achieved in terms of intraday and interday precisions, indicated by the RSDs of <5.0 and <10.0%, respectively. Finally, the proposed method was successfully applied to the determination of penicillin antibiotics residues in different milk and honey samples.  相似文献   

18.
Using triacontyl bonded silica (C30) as on-line solid-phase extraction (SPE) material and a specially designed on-line analytical system which allowed large sample volume injection, a high speed and robust on-line SPE-HPLC–MS method was established for the analysis of five estrogens and bisphenol A (BPA) in milk samples. The milk sample is pretreated with acetonitrile for protein precipitation and then treated with primary secondary amine for the removal of polar impurities in the matrix. Then the pretreated sample can be automatically loaded by a LC pump. For effective extraction, an offshoot with NH4Ac solution of high-flow rate was employed to dilute the loaded sample by a mixing tee before sample was loaded onto the C30 extraction column. In this way, large volume injection (1 mL in this experiment) could be achieved. Some important parameters such as sample loading flow rate, sample dilution ratio and injection volume were optimized. Under the optimized conditions, the recoveries for all analytes range from 71.4 to 97.1% and reproducibility represented as RSDs are less than 15.0% (n = 5) with milk samples spiked at 0.6 and 15 ng/mL of each analyte. To the authors’ knowledge, it constitutes the first work describing a C30 on-line SPE-LC–MS analytical method for the screen and monitoring of these estrogens and BPA in milk.  相似文献   

19.
A new sorbent – salen impregnated silica gel – was prepared and characterised for application as a minicolumn packing for flow-injection on-line preconcentration of cadmium(II). The system was coupled with flame atomic absorption spectrometer (FI-FAAS). The optimal pH for Cd(II) sorption was in the range of 7.4–8.8 and nitric acid (1%, v/v) was efficient as eluent. Sorption was most effective within the sample flow rate up to 7?mL?min?1. Sorption capacity of the sorbent found in a batch procedure was 26.3?µmol?g?1 (2.95?mg?g?1). Enrichment factor (EF) and limit of detection (LOD) obtained for 120-second loading time were 113 and 0.26?µg?L?1, respectively. The sorbent stability in the working conditions was proved for at least 100 preconcentration cycles. The evaluated method was applied to Cd(II) determination in various water samples.  相似文献   

20.
In the work the procedure of chromium(VI) determination by catalytic adsorptive stripping voltammetry (CAdSV) with application of fumed silica, is presented. Two variants of the method are proposed: in the first fumed silica is put directly to the electrolytic cell containing tested solution, in the second the silica is shaken with the sample and next centrifuged. The effectiveness of many surface‐active substances removal from synthetic solutions as well as natural water samples, is studied. In the experiments the fumed silica (Sigma‐Aldrich) of the specific surface area in the range 200–390 m2 g?1 was used. Two types of the working electrodes were applied, i.e., hanging mercury drop electrode (HMDE) and cyclic renewable mercury film electrode (Hg(Ag)FE). In the silica presence i) the relative standard deviation (RSD) for 0.1 μg L?1 Cr(VI) is <2% (HMDE) and <5% (Hg(Ag)FE), n=7, ii) the detection limits estimated deposition time 20 s were respectively 14 ng L?1 (HMDE) and 22 ng L?1 (Hg(Ag)FE). The accuracy of the method was tested by studying the recovery of Cr(VI) from spiked natural water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号