共查询到20条相似文献,搜索用时 31 毫秒
1.
Lijuan Zhang Binyu Zhao Lian Xue Zhi Guo Yaming Dong Haiping Fang Renzhong Tai Jun Hu 《Journal of synchrotron radiation》2013,20(3):413-418
Synchrotron‐based scanning transmission soft X‐ray microscopy (STXM) with nanometer resolution was used to investigate the existence and behavior of interfacial gas nanobubbles confined between two silicon nitride windows. The observed nanobubbles of SF6 and Ne with diameters smaller than 2.5 µm were quite stable. However, larger bubbles became unstable and grew during the soft X‐ray imaging, indicating that stable nanobubbles may have a length scale, which is consistent with a previous report using atomic force microscopy [Zhang et al. (2010), Soft Matter, 6 , 4515–4519]. Here, it is shown that STXM is a promising technique for studying the aggregation of gases near the solid/water interfaces at the nanometer scale. 相似文献
2.
J. Thieme J. Sedlmair S.‐C. Gleber J. Prietzel J. Coates K. Eusterhues G. Abbt‐Braun M. Salome 《Journal of synchrotron radiation》2010,17(2):149-157
X‐ray microscopy is capable of imaging particles in the nanometer size range directly with sub‐micrometer spatial resolution and can be combined with high spectral resolution for spectromicroscopy studies. Two types of microscopes are common in X‐ray microscopy: the transmission X‐ray microscope and the scanning transmission X‐ray microscope; their set‐ups are explained in this paper. While the former takes high‐resolution images from an object with exposure times of seconds or faster, the latter is very well suited as an analytical instrument for spectromicroscopy. The morphology of clusters or particles from soil and sediment samples has been visualized using a transmission X‐ray microscope. Images are shown from a cryo‐tomography experiment based on X‐ray microscopy images to obtain information about the three‐dimensional structure of clusters of humic substances. The analysis of a stack of images taken with a scanning transmission X‐ray microscope to combine morphology and chemistry within a soil sample is shown. X‐ray fluorescence is a method ideally applicable to the study of elemental distributions and binding states of elements even on a trace level using X‐ray energies above 1 keV. 相似文献
3.
Simultaneous X‐ray fluorescence and scanning X‐ray diffraction microscopy at the Australian Synchrotron XFM beamline 下载免费PDF全文
Michael W. M. Jones Nicholas W. Phillips Grant A. van Riessen Brian Abbey David J. Vine Youssef S. G. Nashed Stephen T. Mudie Nader Afshar Robin Kirkham Bo Chen Eugeniu Balaur Martin D. de Jonge 《Journal of synchrotron radiation》2016,23(5):1151-1157
Owing to its extreme sensitivity, quantitative mapping of elemental distributions via X‐ray fluorescence microscopy (XFM) has become a key microanalytical technique. The recent realisation of scanning X‐ray diffraction microscopy (SXDM) meanwhile provides an avenue for quantitative super‐resolved ultra‐structural visualization. The similarity of their experimental geometries indicates excellent prospects for simultaneous acquisition. Here, in both step‐ and fly‐scanning modes, robust, simultaneous XFM‐SXDM is demonstrated. 相似文献
4.
Design and performance of an X‐ray scanning microscope at the Hard X‐ray Nanoprobe beamline of NSLS‐II 下载免费PDF全文
E. Nazaretski H. Yan K. Lauer N. Bouet X. Huang W. Xu J. Zhou D. Shu Y Hwu Y. S. Chu 《Journal of synchrotron radiation》2017,24(6):1113-1119
A hard X‐ray scanning microscope installed at the Hard X‐ray Nanoprobe beamline of the National Synchrotron Light Source II has been designed, constructed and commissioned. The microscope relies on a compact, high stiffness, low heat dissipation approach and utilizes two types of nanofocusing optics. It is capable of imaging with ~15 nm × 15 nm spatial resolution using multilayer Laue lenses and 25 nm × 26 nm resolution using zone plates. Fluorescence, diffraction, absorption, differential phase contrast, ptychography and tomography are available as experimental techniques. The microscope is also equipped with a temperature regulation system which allows the temperature of a sample to be varied in the range between 90 K and 1000 K. The constructed instrument is open for general users and offers its capabilities to the material science, battery research and bioscience communities. 相似文献
5.
Hyun-Joon Shin Namdong Kim Hee-Seob Kim Wol-Woo Lee Chae-Soon Lee Bongsoo Kim 《Journal of synchrotron radiation》2018,25(3):878-884
A scanning transmission X‐ray microscope is operational at the 10A beamline at the Pohang Light Source. The 10A beamline provides soft X‐rays in the photon energy range 100–2000 eV using an elliptically polarized undulator. The practically usable photon energy range of the scanning transmission X‐ray microscopy (STXM) setup is from ~150 to ~1600 eV. With a zone plate of 25 nm outermost zone width, the diffraction‐limited space resolution, ~30 nm, is achieved in the photon energy range up to ~850 eV. In transmission mode for thin samples, STXM provides the element, chemical state and magnetic moment specific distributions, based on absorption spectroscopy. A soft X‐ray fluorescence measurement setup has been implemented in order to provide the elemental distribution of thicker samples as well as chemical state information with a space resolution of ~50 nm. A ptychography setup has been implemented in order to improve the space resolution down to 10 nm. Hardware setups and application activities of the STXM are presented. 相似文献
6.
Yu‐Sheng Chen Huang‐Han Chen Tsong‐Tse Li Edwin Ong Jun Lim Giorgio Margaritondo En‐Te Hwu Yeukuang Hwu 《Journal of synchrotron radiation》2014,21(2):376-379
A compact transmission X‐ray microscope has been designed and implemented based on a cylindrical symmetry around the optical axis that sharply limits the instabilities due to thermal mechanical drift. Identical compact multi‐axis closed‐loop actuation modules drive different optical components. The design is modular and simplifies the change of individual parts, e.g. the use of different magnification and focusing devices. This compact instrument can be easily transported between laboratory and synchrotron facilities and quickly put into operation. An automated alignment mechanism simplifies the assembly of different modules after transportation. After describing the design details, the results of the first tests are presented. 相似文献
7.
Transmission X‐ray mirrors have been fabricated from 300–400 nm‐thick low‐stress silicon nitride windows of size 0.6 mm × 85 mm. The windows act as a high‐pass energy filter at grazing incidence in an X‐ray beam for the beam transmitted through the window. The energy cut‐off can be selected by adjusting the incidence angle of the transmission mirror, because the energy cut‐off is a function of the angle of the window with respect to the beam. With the transmission mirror at the target angle of 0.22°, a 0.3 mm × 0.3 mm X‐ray beam was allowed to pass through the mirror with a cut‐off energy of 10 keV at the Cornell High Energy Synchrotron Source. The energy cut‐off can be adjusted from 8 to 12 keV at an angle of 0.26° to 0.18°, respectively. The observed mirror transmittance was above 80% for a 300 nm‐thick film. 相似文献
8.
Florian Meirer Jordi Cabana Yijin Liu Apurva Mehta Joy C. Andrews Piero Pianetta 《Journal of synchrotron radiation》2011,18(5):773-781
The ability to probe morphology and phase distribution in complex systems at multiple length scales unravels the interplay of nano‐ and micrometer‐scale factors at the origin of macroscopic behavior. While different electron‐ and X‐ray‐based imaging techniques can be combined with spectroscopy at high resolutions, owing to experimental time limitations the resulting fields of view are too small to be representative of a composite sample. Here a new X‐ray imaging set‐up is proposed, combining full‐field transmission X‐ray microscopy (TXM) with X‐ray absorption near‐edge structure (XANES) spectroscopy to follow two‐dimensional and three‐dimensional morphological and chemical changes in large volumes at high resolution (tens of nanometers). TXM XANES imaging offers chemical speciation at the nanoscale in thick samples (>20 µm) with minimal preparation requirements. Further, its high throughput allows the analysis of large areas (up to millimeters) in minutes to a few hours. Proof of concept is provided using battery electrodes, although its versatility will lead to impact in a number of diverse research fields. 相似文献
9.
Akihisa Takeuchi Yasuko Terada Yoshio Suzuki Kentaro Uesugi Sadao Aoki 《Journal of synchrotron radiation》2009,16(5):616-621
A confocal full‐field X‐ray microscope has been developed for use as a novel three‐dimensional X‐ray imaging method. The system consists of an X‐ray illuminating `sheet‐beam' whose beam shape is micrified only in one dimension, and an X‐ray full‐field microscope whose optical axis is normal to the illuminating sheet beam. An arbitral cross‐sectional region of the object is irradiated by the sheet‐beam, and secondary X‐ray emission such as fluorescent X‐rays from this region is imaged simultaneously using the full‐field microscope. This system enables a virtual sliced image of a specimen to be obtained as a two‐dimensional magnified image, and three‐dimensional observation is available only by a linear translation of the object along the optical axis of the full‐field microscope. A feasibility test has been carried out at beamline 37XU of SPring‐8. Observation of the three‐dimensional distribution of metallic inclusions in an artificial diamond was performed. 相似文献
10.
Chung‐Jong Yu Hae Cheol Lee Chan Kim Wonsuk Cha Jerome Carnis Yoonhee Kim Do Young Noh Hyunjung Kim 《Journal of synchrotron radiation》2014,21(1):264-267
The coherent X‐ray scattering beamline at the 9C port of the upgraded Pohang Light Source (PLS‐II) at Pohang Accelerator Laboratory in Korea is introduced. This beamline provides X‐rays of 5–20 keV, and targets coherent X‐ray experiments such as coherent diffraction imaging and X‐ray photon correlation spectroscopy. The main parameters of the beamline are summarized, and some preliminary experimental results are described. 相似文献
11.
The MISTRAL beamline is one of the seven phase‐I beamlines at the ALBA synchrotron light source (Barcelona, Spain) that will be opened to users at the end of 2010. MISTRAL will be devoted to cryotomography in the water window and multi‐keV spectral regions for biological applications. The optics design consists of a plane‐grating monochromator that has been implemented using variable‐line‐spacing gratings to fulfil the requirements of X‐ray microscopy using a reflective condenser. For instance, a fixed‐focus condition independent of the included angle, constant magnification as well as coma and spherical aberration corrections are achieved with this system. The reported design is of wider use. 相似文献
12.
M. K. Tiwari P. Gupta A. K. Sinha S. R. Kane A. K. Singh S. R. Garg C. K. Garg G. S. Lodha S. K. Deb 《Journal of synchrotron radiation》2013,20(2):386-389
A microfocus X‐ray fluorescence spectroscopy beamline (BL‐16) at the Indian synchrotron radiation facility Indus‐2 has been constructed with an experimental emphasis on environmental, archaeological, biomedical and material science applications involving heavy metal speciation and their localization. The beamline offers a combination of different analytical probes, e.g. X‐ray fluorescence mapping, X‐ray microspectroscopy and total‐external‐reflection fluorescence characterization. The beamline is installed on a bending‐magnet source with a working X‐ray energy range of 4–20 keV, enabling it to excite K‐edges of all elements from S to Nb and L‐edges from Ag to U. The optics of the beamline comprises of a double‐crystal monochromator with Si(111) symmetric and asymmetric crystals and a pair of Kirkpatrick–Baez focusing mirrors. This paper describes the performance of the beamline and its capabilities with examples of measured results. 相似文献
13.
Minas Balyan 《Journal of synchrotron radiation》2013,20(5):749-755
An X‐ray dynamical diffraction Fraunhofer holographic scheme is proposed. Theoretically it is shown that the reconstruction of the object image by visible light is possible. The spatial and temporal coherence requirements of the incident X‐ray beam are considered. As an example, the hologram recording as well as the reconstruction by visible light of an absolutely absorbing wire are discussed. 相似文献
14.
Nouamane Laanait Zhan Zhang Christian M. Schlepütz Joan Vila‐Comamala Matthew J. Highland Paul Fenter 《Journal of synchrotron radiation》2014,21(6):1252-1261
Novel X‐ray imaging of structural domains in a ferroelectric epitaxial thin film using diffraction contrast is presented. The full‐field hard X‐ray microscope uses the surface scattering signal, in a reflectivity or diffraction experiment, to spatially resolve the local structure with 70 nm lateral spatial resolution and sub‐nanometer height sensitivity. Sub‐second X‐ray exposures can be used to acquire a 14 µm × 14 µm image with an effective pixel size of 20 nm on the sample. The optical configuration and various engineering considerations that are necessary to achieve optimal imaging resolution and contrast in this type of microscopy are discussed. 相似文献
15.
Yuya Shinohara Akira Watanabe Hiroyuki Kishimoto Yoshiyuki Amemiya 《Journal of synchrotron radiation》2013,20(5):801-804
Combined X‐ray photon correlation spectroscopy (XPCS) and diffracted X‐ray tracking (DXT) measurements of carbon‐black nanocrystals embedded in styrene–butadiene rubber were performed. From the intensity fluctuation of speckle patterns in a small‐angle scattering region (XPCS), dynamical information relating to the translational motion can be obtained, and the rotational motion is observed through the changes in the positions of DXT diffraction spots. Graphitized carbon‐black nanocrystals in unvulcanized styrene–butadiene rubber showed an apparent discrepancy between their translational and rotational motions; this result seems to support a stress‐relaxation model for the origin of super‐diffusive particle motion that is widely observed in nanocolloidal systems. Combined measurements using these two techniques will give new insights into nanoscopic dynamics, and will be useful as a microrheology technique. 相似文献
16.
Current status of the TwinMic beamline at Elettra: a soft X‐ray transmission and emission microscopy station 下载免费PDF全文
Alessandra Gianoncelli George Kourousias Lucia Merolle Matteo Altissimo Anna Bianco 《Journal of synchrotron radiation》2016,23(6):1526-1537
The current status of the TwinMic beamline at Elettra synchrotron light source, that hosts the European twin X‐ray microscopy station, is reported. The X‐ray source, provided by a short hybrid undulator with source size and divergence intermediate between bending magnets and conventional undulators, is energy‐tailored using a collimated plane‐grating monochromator. The TwinMic spectromicroscopy experimental station combines scanning and full‐field imaging in a single instrument, with contrast modes such as absorption, differential phase, interference and darkfield. The implementation of coherent diffractive imaging modalities and ptychography is ongoing. Typically, scanning transmission X‐ray microscopy images are simultaneously collected in transmission and differential phase contrast and can be complemented by chemical and elemental analysis using across‐absorption‐edge imaging, X‐ray absorption near‐edge structure or low‐energy X‐ray fluorescence. The lateral resolutions depend on the particular imaging and contrast mode chosen. The TwinMic range of applications covers diverse research fields such as biology, biochemistry, medicine, pharmacology, environment, geochemistry, food, agriculture and materials science. They will be illustrated in the paper with representative results. 相似文献
17.
Cinthia Piamonteze Uwe Flechsig Stefano Rusponi Jan Dreiser Jakoba Heidler Marcus Schmidt Reto Wetter Marco Calvi Thomas Schmidt Helena Pruchova Juraj Krempasky Christoph Quitmann Harald Brune Frithjof Nolting 《Journal of synchrotron radiation》2012,19(5):661-674
X‐Treme is a soft X‐ray beamline recently built in the Swiss Light Source at the Paul Scherrer Institut in collaboration with École Polytechnique Fédérale de Lausanne. The beamline is dedicated to polarization‐dependent X‐ray absorption spectroscopy at high magnetic fields and low temperature. The source is an elliptically polarizing undulator. The end‐station has a superconducting 7 T–2 T vector magnet, with sample temperature down to 2 K and is equipped with an in situ sample preparation system for surface science. The beamline commissioning measurements, which show a resolving power of 8000 and a maximum flux at the sample of 4.7 × 1012 photons s?1, are presented. Scientific examples showing X‐ray magnetic circular and X‐ray magnetic linear dichroism measurements are also presented. 相似文献
18.
19.
Shengxiang Wang Dajiang Wang Qiao Wu Kun Gao Zhili Wang Ziyu Wu 《Journal of synchrotron radiation》2015,22(4):1091-1095
For the first time, the three‐dimensional (3D) ultrastructure of an intact rice pollen cell has been obtained using a full‐field transmission hard X‐ray microscope operated in Zernike phase contrast mode. After reconstruction and segmentation from a series of projection images, complete 3D structural information of a 35 µm rice pollen grain is presented at a resolution of ~100 nm. The reconstruction allows a clear differentiation of various subcellular structures within the rice pollen grain, including aperture, lipid body, mitochondrion, nucleus and vacuole. Furthermore, quantitative information was obtained about the distribution of cytoplasmic organelles and the volume percentage of each kind of organelle. These results demonstrate that transmission X‐ray microscopy can be quite powerful for non‐destructive investigation of 3D structures of whole eukaryotic cells. 相似文献
20.
Inna Bukreeva Andrea Sorrentino Alessia Cedola Ennio Giovine Ana Diaz Fernando Scarinci Werner Jark Leonid Ognev Stefano Lagomarsino 《Journal of synchrotron radiation》2013,20(5):691-697
The properties of X‐ray vacuum‐gap waveguides (WGs) with additional periodic structure on one of the reflecting walls are studied. Theoretical considerations, numerical simulations and experimental results confirm that the periodic structure imposes additional conditions on efficient propagation of the electromagnetic field along the WGs. The transmission is maximum for guided modes that possess sufficient phase synchronism with the periodic structure (here called `super‐resonances'). The field inside the WGs is essentially given at low incidence angle by the fundamental mode strongly coupled with the corresponding phased‐matched mode. Both the simulated and the experimental diffraction patterns show in the far field that propagation takes place essentially only for low incidence angles, confirming the mode filtering properties of the structured X‐ray waveguides. 相似文献