首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 20 毫秒
1.
Synchrotrons are capable of producing intense low‐energy X‐rays that enable the photoactivation of high‐Z elements. Photoactivation therapy (PAT) consists of loading tumors with photoactivatable drugs and thereafter irradiating them at an energy, generally close to the K‐edge of the element, that enhances the photoelectric effect. To date, three major photoactivatable elements are used in PAT: platinum (cisplatin and carboplatin), iodine (iodinated contrast agents and iododeoxyuridine) and gadolinium (motexafin gadolinium). However, the molecular and cellular events specific to PAT and the radiobiological properties of these photoactivatable drugs are still misknown. Here, it is examined how standard and synchrotron X‐rays combined with photoactivatable drugs impact on the cellular response of human endothelial cells. These findings suggest that the radiolysis products of the photoactivatable drugs may participate in the synergetic effects of PAT by increasing the severity of radiation‐induced DNA double‐strand breaks. Interestingly, subpopulation of highly damaged cells was found to be a cellular pattern specific to PAT. The data show that the efficiency of emerging anti‐cancer modalities involving synchrotron photoactivation strongly depends on the choice of photoactivatable drugs, and important series of experiments are required to secure their clinical transfer before applying to humans.  相似文献   

2.
Microbeam radiation therapy (MRT) is a novel irradiation technique for brain tumours treatment currently under development at the European Synchrotron Radiation Facility in Grenoble, France. The technique is based on the spatial fractionation of a highly brilliant synchrotron X‐ray beam into an array of microbeams using a multi‐slit collimator (MSC). After promising pre‐clinical results, veterinary trials have recently commenced requiring the need for dedicated quality assurance (QA) procedures. The quality of MRT treatment demands reproducible and precise spatial fractionation of the incoming synchrotron beam. The intensity profile of the microbeams must also be quickly and quantitatively characterized prior to each treatment for comparison with that used for input to the dose‐planning calculations. The Centre for Medical Radiation Physics (University of Wollongong, Australia) has developed an X‐ray treatment monitoring system (X‐Tream) which incorporates a high‐spatial‐resolution silicon strip detector (SSD) specifically designed for MRT. In‐air measurements of the horizontal profile of the intrinsic microbeam X‐ray field in order to determine the relative intensity of each microbeam are presented, and the alignment of the MSC is also assessed. The results show that the SSD is able to resolve individual microbeams which therefore provides invaluable QA of the horizontal field size and microbeam number and shape. They also demonstrate that the SSD used in the X‐Tream system is very sensitive to any small misalignment of the MSC. In order to allow as rapid QA as possible, a fast alignment procedure of the SSD based on X‐ray imaging with a low‐intensity low‐energy beam has been developed and is presented in this publication.  相似文献   

3.
This work reports an unconventional defect engineering approach using synchrotron‐radiation‐based X‐rays on ceria nanocrystal catalysts of particle sizes 4.4–10.6 nm. The generation of a large number of oxygen‐vacancy defects (OVDs), and therefore an effective reduction of cations, has been found in CeO2 catalytic materials bombarded by high‐intensity synchrotron X‐ray beams of beam size 1.5 mm × 0.5 mm, photon energies of 5.5–7.8 keV and photon fluxes up to 1.53 × 1012 photons s?1. The experimentally observed cation reduction was theoretically explained by a first‐principles formation‐energy calculation for oxygen vacancy defects. The results clearly indicate that OVD formation is mainly a result of X‐ray‐excited core holes that give rise to valence holes through electron down conversion in the material. Thermal annealing and subvalent Y‐doping were also employed to modulate the efficiency of oxygen escape, providing extra control on the X‐ray‐induced OVD generating process. Both the core‐hole‐dominated bond breaking and oxygen escape mechanisms play pivotal roles for efficient OVD formation. This X‐ray irradiation approach, as an alternative defect engineering method, can be applied to a wide variety of nanostructured materials for physical‐property modification.  相似文献   

4.
5.
Gold nanoparticles are excellent intracellular markers in X‐ray imaging. Having shown previously the suitability of gold nanoparticles to detect small groups of cells with the synchrotron‐based computed tomography (CT) technique both ex vivo and in vivo, it is now demonstrated that even single‐cell resolution can be obtained in the brain at least ex vivo. Working in a small animal model of malignant brain tumour, the image quality obtained with different imaging modalities was compared. To generate the brain tumour, 1 × 105 C6 glioma cells were loaded with gold nanoparticles and implanted in the right cerebral hemisphere of an adult rat. Raw data were acquired with absorption X‐ray CT followed by a local tomography technique based on synchrotron X‐ray absorption yielding single‐cell resolution. The reconstructed synchrotron X‐ray images were compared with images obtained by small animal magnetic resonance imaging. The presence of gold nanoparticles in the tumour tissue was verified in histological sections.  相似文献   

6.
A new concept for shortening hard X‐ray pulses emitted from a third‐generation synchrotron source down to few picoseconds is presented. The device, called the PicoSwitch, exploits the dynamics of coherent acoustic phonons in a photo‐excited thin film. A characterization of the structure demonstrates switching times of ≤ 5 ps and a peak reflectivity of ~10?3. The device is tested in a real synchrotron‐based pump–probe experiment and reveals features of coherent phonon propagation in a second thin film sample, thus demonstrating the potential to significantly improve the temporal resolution at existing synchrotron facilities.  相似文献   

7.
In this article the effects induced by exposure of sol–gel thin films to hard X‐rays have been studied. Thin films of silica and hybrid organic–inorganic silica have been prepared via dip‐coating and the materials were exposed immediately after preparation to an intense source of light of several keV generated by a synchrotron source. The samples were exposed to increasing doses and the effects of the radiation have been evaluated by Fourier transform infrared spectroscopy, spectroscopic ellipsometry and atomic force microscopy. The X‐ray beam induces a significant densification on the silica films without producing any degradation such as cracks, flaws or delamination at the interface. The densification is accompanied by a decrease in thickness and an increase in refractive index both in the pure silica and in the hybrid films. The effect on the hybrid material is to induce densification through reaction of silanol groups but also removal of the organic groups, which are covalently bonded to silicon via Si—C bonds. At the highest exposure dose the removal of the organic groups is complete and the film becomes pure silica. Hard X‐rays can be used as an efficient and direct writing tool to pattern coating layers of different types of compositions.  相似文献   

8.
Combined X‐ray photon correlation spectroscopy (XPCS) and diffracted X‐ray tracking (DXT) measurements of carbon‐black nanocrystals embedded in styrene–butadiene rubber were performed. From the intensity fluctuation of speckle patterns in a small‐angle scattering region (XPCS), dynamical information relating to the translational motion can be obtained, and the rotational motion is observed through the changes in the positions of DXT diffraction spots. Graphitized carbon‐black nanocrystals in unvulcanized styrene–butadiene rubber showed an apparent discrepancy between their translational and rotational motions; this result seems to support a stress‐relaxation model for the origin of super‐diffusive particle motion that is widely observed in nanocolloidal systems. Combined measurements using these two techniques will give new insights into nanoscopic dynamics, and will be useful as a microrheology technique.  相似文献   

9.
The combination of synchrotron X‐ray radiation and metal‐based radiosensitizer is a novel form of photon activation therapy which offers the advantage of treating malignant tumors with greater efficacy and higher precision than conventional radiation therapy. In this study the anticancer cytotoxic efficacy of a new chlorophyll derivative, iodinated chlorin p6 copper complex (ICp6‐Cu), combined with synchrotron X‐ray radiation (8–10 keV) in two human oral cancer cell lines is explored. Pre‐treatment of cells with 20 µM and 30 µM ICp6‐Cu for 3 h was found to enhance the X‐ray‐induced cytotoxicity with sensitization enhancement ratios of 1.8 and 2.8, respectively. ICp6‐Cu localized in cytoplasm, mainly in lysosomes and endoplasmic reticulum, and did not cause any cytotoxicity alone. The radiosensitization effect of ICp6‐Cu accompanied a significant increase in the level of reactive oxygen species, damage to lysosomes, inhibition of repair of radiation‐induced DNA double‐strand breaks, increase in cell death and no significant effect on cell cycle progression. These results demonstrate that ICp6‐Cu is a potential agent for synchrotron photon activation therapy of cancer.  相似文献   

10.
X‐ray detected magnetic resonance (XDMR) is a new element‐selective spectroscopy in which X‐ray magnetic circular dichroism is used to probe the resonant precession of spin and orbital magnetization components when a strong microwave pump field is applied perpendicularly to the static bias field. Experimental configurations suitable for detecting the very weak XDMR signal are compared. XDMR signatures were measured in yttrium iron garnet and related thin films on exciting not only the iron K‐edge but also the yttrium at diamagnetic sites. These measurements are shown to yield unique information regarding the wide‐angle precession of induced magnetization components involving either orbital p‐projected densities of states at the iron sites, or spin polarized d‐projected densities of states at the yttrium sites. Extending XDMR measurements into the millimeter wave range would make it possible to study paramagnetic systems routinely and investigate optical modes as well as acoustic modes in ferrimagnetic/antiferromagnetic systems.  相似文献   

11.
The first imaging results obtained from a small‐size synchrotron are reported. The newly developed Compact Light Source produces inverse Compton X‐rays at the intersection point of the counter propagating laser and electron beam. The small size of the intersection point gives a highly coherent cone beam with a few milliradian angular divergence and a few percent energy spread. These specifications make the Compact Light Source ideal for a recently developed grating‐based differential phase‐contrast imaging method.  相似文献   

12.
The tabletop synchrotron light sources MIRRORCLE‐6X and MIRRORCLE‐20SX, operating at electron energies Eel = 6 MeV and Eel = 20 MeV, respectively, can emit powerful transition radiation (TR) in the extreme ultraviolet (EUV) and the soft X‐ray regions. To clarify the applicability of these soft X‐ray and EUV sources, the total TR power has been determined. A TR experiment was performed using a 385 nm‐thick Al foil target in MIRRORCLE‐6X. The angular distribution of the emitted power was measured using a detector assembly based on an NE102 scintillator, an optical bundle and a photomultiplier. The maximal measured total TR power for MIRRORCLE‐6X is Pmax? 2.95 mW at full power operation. Introduction of an analytical expression for the lifetime of the electron beam allows calculation of the emitted TR power by a tabletop synchrotron light source. Using the above measurement result, and the theoretically determined ratio between the TR power for MIRRORCLE‐6X and MIRRORCLE‐20SX, the total TR power for MIRRORCLE‐20SX can be obtained. The one‐foil TR target thickness is optimized for the 20 MeV electron energy. Pmax? 810 mW for MIRRORCLE‐20SX is obtained with a single foil of 240 nm‐thick Be target. The emitted bremsstrahlung is negligible with respect to the emitted TR for optimized TR targets. From a theoretically known TR spectrum it is concluded that MIRRORCLE‐20SX can emit 150 mW of photons with E > 500 eV, which makes it applicable as a source for performing X‐ray lithography. The average wavelength, = 13.6 nm, of the TR emission of MIRRORCLE‐20SX, with a 200 nm Al target, could provide of the order of 1 W EUV.  相似文献   

13.
Recent research progress using X‐ray cryo‐crystallography with the photon beams from third‐generation synchrotron sources has resulted in recognition that this intense radiation commonly damages protein samples even when they are held at 100 K. Other structural biologists examining thin protein crystals or single particle specimens encounter similar radiation damage problems during electron diffraction and imaging, but have developed some effective countermeasures. The aim of this concise review is to examine whether analogous approaches can be utilized to alleviate the X‐ray radiation damage problem in synchrotron macromolecular crystallography. The critical discussion of this question is preceded by presentation of background material on modern technical procedures with electron beam instruments using 300–400 kV accelerating voltage, low‐dose exposures for data recording, and protection of protein specimens by cryogenic cooling; these practical approaches to dealing with electron radiation damage currently permit best resolution levels of 6 Å (0.6 nm) for single particle specimens, and of 1.9 Å for two‐dimensional membrane protein crystals. Final determination of the potential effectiveness and practical value of using such new or unconventional ideas will necessitate showing, by experimental testing, that these produce significantly improved protection of three‐dimensional protein crystals during synchrotron X‐ray diffraction.  相似文献   

14.
When small triangular prisms are arranged in arrays which have an overall appearance like an hourglass (in Italian: clessidra) they can focus X‐rays owing to a combined action of diffraction and refraction. From the optical point of view these objects can be regarded as a Fresnel variant of concave transmission lenses. Consequently they can provide larger apertures than purely refractive lenses. However, one has to recognize that clessidra lenses will strongly diffract as the lens structure is periodic in the direction perpendicular to the incident beam. In experiments the diffraction is reduced because it is difficult to illuminate the large apertures with a full spatially coherent wavefront. So the illumination is at best partially coherent. In order to interpret available experimental data for this condition, diffraction theory has been applied appropriately to the clessidra structure, taking into account the limited spatial coherence. The agreement between the theoretical simulations and experimental data is very good, keeping the lens properties at their projected values and allowing for only two free model parameters. The first is the lateral spatial coherence; the second is a lens defect, a rounding of all edges and tips in the structure. Both values obtained from the simulations have been found to be in agreement with expectations.  相似文献   

15.
Single‐crystal diamond is a material with great potential for the fabrication of X‐ray photon beam‐position monitors with submicrometre spatial resolution. Low X‐ray absorption combined with radiation hardness and excellent thermal‐mechanical properties make possible beam‐transmissive diamond devices for monitoring synchrotron and free‐electron laser X‐ray beams. Tests were made using a white bending‐magnet synchrotron X‐ray beam at DESY to investigate the performance of a position‐sensitive diamond device using radiofrequency readout electronics. The device uniformity and position response were measured in a 25 µm collimated X‐ray beam with an I‐Tech Libera `Brilliance' system. This readout system was designed for position measurement and feedback control of the electron beam in the synchrotron storage ring, but, as shown here, it can also be used for accurate position readout of a quadrant‐electrode single‐crystal diamond sensor. The centre‐of‐gravity position of the F4 X‐ray beam at the DORIS III synchrotron was measured with the diamond signal output digitally sampled at a rate of 130 Msample s?1 by the Brilliance system. Narrow‐band filtering and digital averaging of the position signals resulted in a measured position noise below 50 nm (r.m.s.) for a 10 Hz bandwidth.  相似文献   

16.
A Monte Carlo algorithm has been developed to calculate the instrumental profile function of a powder diffraction synchrotron beamline. Realistic models of all optical elements are implemented in a ray‐tracing software. The proposed approach and the emerging paradigm have been investigated and verified for several existing X‐ray powder diffraction beamlines. The results, which can be extended to further facilities, show a new and general way of assessing the contribution of instrumental broadening to synchrotron radiation data, based on ab initio simulations.  相似文献   

17.
Experiments using a simple X‐ray interferometer to measure the degree of spatial coherence of hard X‐rays are reported. A monolithic Fresnel bimirror is used at small incidence angles to investigate synchrotron radiation in the energy interval 5–50 keV with monochromatic and white beam. The experimental set‐up was equivalent to a Young's double‐slit experiment for hard X‐rays with slit dimensions in the micrometre range. From the high‐contrast interference pattern the degree of coherence was determined.  相似文献   

18.
The ability to achieve uniform stress in uniaxial compression tests of polycrystalline alumina is of significance for the calibration of piezospectroscopic coefficients as well as strength studies in ceramics. In this study high‐energy X‐rays were used to capture powder diffraction profiles over a half‐section of a polycrystalline alumina parallelepiped sample under an increasing uniaxial compressive load. The data were converted to strain and results were used for stress mapping of the sample. Stress maps from the study quantify the higher stresses at the sample–platen contact interface and reveal the evolution of the stress distribution in these specimens with load. For the geometry of the samples used, at the center section of the specimen the overall magnitudes of the compressive stresses were found to be 20% higher compared with the average expected theoretical stress based on the applied load and cross‐sectional area. The observed compressive stresses at the corners of the parallelepiped specimen were 62% higher and shear stresses were observed at the specimen interface to the load mechanism. The effects, seen at the interface, can lead to premature failure at these locations and can affect the accuracy of calibration of spectral peaks with stress as well as compression strength measurements. The results provide important information that can be used to establish guidelines on material and geometry considerations in developing compression tests on high‐strength ceramics.  相似文献   

19.
20.
For the first time the third‐order nonlinear time‐dependent Takagi's equations of X‐rays in crystals are obtained and investigated. The third‐order nonlinear and linear time‐dependent dynamical diffraction of X‐rays spatially restricted in the diffraction plane pulses in crystals is investigated theoretically. A method of solving the linear and the third‐order nonlinear time‐dependent Takagi's equations is proposed. Based on this method, results of analytical and numerical calculations for both linear and nonlinear diffraction cases are presented and compared.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号