首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple variant of a Si internally cooled inclined X‐ray monochromator of reasonable size is proposed. It has two inclined surfaces oriented into a V shape. This design substantially decreases the surface deformations introduced by radiation heat, and the size of the crystal is still feasible for a 50 mm broad impinging bending magnet or wiggler beam. The possibility of sagittal focusing of the diffracted beam is also discussed.  相似文献   

2.
The effect of angular vibrations of the crystals in cryogenically cooled monochromators on the beam performance has been studied theoretically and experimentally. A simple relation between amplitude of the vibrations and size of the focused beam is developed. It is shown that the double‐crystal monochromator vibrations affect not only the image size but also the image position along the optical axis. Several methods to measure vibrations with the X‐ray beam are explained and analyzed. The methods have been applied to systematically study angular crystal vibrations at monochromators installed at the PETRA III light source. Characteristic values of the amplitudes of angular vibrations for different monochromators are presented.  相似文献   

3.
Fabrication and results of high‐resolution X‐ray topography characterization of diamond single‐crystal plates with large surface area (10 mm × 10 mm) and (111) crystal surface orientation for applications in high‐heat‐load X‐ray crystal optics are reported. The plates were fabricated by laser‐cutting of the (111) facets of diamond crystals grown using high‐pressure high‐temperature methods. The intrinsic crystal quality of a selected 3 mm × 7 mm crystal region of one of the studied samples was found to be suitable for applications in wavefront‐preserving high‐heat‐load crystal optics. Wavefront characterization was performed using sequential X‐ray diffraction topography in the pseudo plane wave configuration and data analysis using rocking‐curve topography. The variations of the rocking‐curve width and peak position measured with a spatial resolution of 13 µm × 13 µm over the selected region were found to be less than 1 µrad.  相似文献   

4.
Simulations of the periods, split regularities and mirror symmetries of the glitch pattern of a Si(111) crystal along with the azimuthal angles are presented. The glitch patterns of Si(111) double‐crystal monochromators (DCMs) are found to be the superposition of the two sets of glitch patterns from the two crystals. The optimal azimuthal orientation ?1,2 = [(2n+1)π]/6 (n = 0, ±1, ±2…) for Si(111) DCMs to achieve the least amount of glitches in the hard X‐ray region has been suggested.  相似文献   

5.
Refractive lenses focus X‐rays chromatically owing to a significant variation of the refractive index of the lens material with photon energy. Then, in combination with an exit slit in the focal plane, such lenses can be used as monochromators. The spectral resolution obtainable with refractive lenses based on prism arrays was recently systematically investigated experimentally. This contribution will show that a wide‐bandpass performance can be predicted with a rather simple analytical approach. Based on the good agreement with the experimental data, one can then more rapidly and systematically optimize the lens structure for a given application. This contribution will then discuss more flexible solutions for the monochromator operation. It will be shown that a new monochromator scheme could easily provide tuning in a fixed‐exit slit.  相似文献   

6.
The simultaneous and active feedback stabilization of X‐ray beam position and monochromatic beam flux during EXAFS scans at the titanium K‐edge as produced by a double‐crystal monochromator beamline is reported. The feedback is generated using two independent feedback loops using separate beam flux and position measurements. The flux is stabilized using a fast extremum‐searching algorithm that is insensitive to changes in the synchrotron ring current and energy‐dependent monochromator output. Corrections of beam height are made using an innovative transmissive beam position monitor instrument. The efficacy of the feedback stabilization method is demonstrated by comparing the measurements of EXAFS spectra on inhomogeneous diluted Ti‐containing samples with and without feedback applied.  相似文献   

7.
A focusing system based on a polycapillary half‐lens optic has been successfully tested for transmission and fluorescence µ‐X‐ray absorption spectroscopy at a third‐generation bending‐magnet beamline equipped with a non‐fixed‐exit Si(111) monochromator. The vertical positional variations of the X‐ray beam owing to the use of a non‐fixed‐exit monochromator were shown to pose only a limited problem by using the polycapillary optic. The expected height variation for an EXAFS scan around the Fe K‐edge is approximately 200 µm on the lens input side and this was reduced to ~1 µm for the focused beam. Beam sizes (FWHM) of 12–16 µm, transmission efficiencies of 25–45% and intensity gain factors, compared with the non‐focused beam, of about 2000 were obtained in the 7–14 keV energy range for an incoming beam of 0.5 × 2 mm (vertical × horizontal). As a practical application, an As K‐edge µ‐XANES study of cucumber root and hypocotyl was performed to determine the As oxidation state in the different plant parts and to identify a possible metabolic conversion by the plant.  相似文献   

8.
The performance of a cryogenically cooled double‐crystal silicon monochromator was studied under high‐heat‐load conditions with total absorbed powers and power densities ranging from 8 to 780 W and from 8 to 240 W mm?2, respectively. When the temperature of the first crystal is maintained close to the temperature of zero thermal expansion of silicon, the monochromator shows nearly ideal performance with a thermal slope error of 0.6 µrad. By tuning the size of the first slit, the regime of the ideal performance can be maintained over a wide range of heat loads, i.e. from power densities of 110 W mm?2 (at total absorbed power of 510 W) to 240 W mm?2 (at total absorbed power of 240 W).  相似文献   

9.
A tantalum pentoxide‐based (Ta2O5‐based) micro‐ring all‐optical modulator was fabricated. The refractive index inside the micro‐ring cavity was modified using the Kerr effect by injecting a pumped pulse. The transmittance of the ring resonator was controlled to achieve all‐optical modulation at the wavelength of the injected probe. When 12 GHz pulses with a peak power of 1.2 W were coupled in the ring cavity, the transmission spectrum of the Ta2O5 resonator was red‐shifted by 0.04 nm because of the Kerr effect. The relationship between the modulation depth and gap of the Ta2O5 directional coupler is discussed. An optimized gap of 1100 nm was obtained, and a maximum buildup factor of 11.7 with 84% modulation depth was achieved. The nonlinear refractive index of Ta2O5 at 1.55 μm was estimated as 3.4 × 10?14 cm2/W based on the Kerr effect, which is almost an order of magnitude higher than that of Si3N4. All results indicate that Ta2O5 has potential for use in nonlinear waveguide applications with modulation speeds as high as tens of GHz.

  相似文献   


10.
Ru/C multilayer monochromators with different periodic thicknesses were investigated using X‐ray grazing‐incidence reflectivity, diffuse scattering, Bragg imaging, morphology testing, etc. before and after cryogenic cooling. Quantitative analyses enabled the determination of the key multilayer structural parameters for samples with different periodic thicknesses, especially the influence from the ruthenium crystallization. The results also reveal that the basic structures and reflection performance keep stable after cryogenic cooling. The low‐temperature treatment smoothed the surfaces and interfaces and changed the growth characteristic to a low‐frequency surface figure. This study helps with the understanding of the structure evolution of multilayer monochromators during cryogenic cooling and presents sufficient experimental proof for using cryogenically cooled multilayer monochromators in a high‐thermal‐load undulator beamline.  相似文献   

11.
A practical method for operating existing undulator synchrotron beamlines at photon energies considerably higher than their standard operating range is described and applied at beamline 19‐ID of the Structural Biology Center at the Advanced Photon Source enabling operation at 30 keV. Adjustments to the undulator spectrum were critical to enhance the 30 keV flux while reducing the lower‐ and higher‐energy harmonic contamination. A Pd‐coated mirror and Al attenuators acted as effective low‐ and high‐bandpass filters. The resulting flux at 30 keV, although significantly lower than with X‐ray optics designed and optimized for this energy, allowed for accurate data collection on crystals of the small protein crambin to 0.38 Å resolution.  相似文献   

12.
The research program at the biomedical imaging facility requires a high‐flux hard‐X‐ray monochromator that can also provide a wide beam. A wide energy range is needed for standard radiography, phase‐contrast imaging, K‐edge subtraction imaging and monochromatic beam therapy modalities. The double‐crystal Laue monochromator, developed for the BioMedical Imaging and Therapy facility, is optimized for the imaging of medium‐ and large‐scale samples at high energies with the resolution reaching 4 µm. A pair of 2 mm‐thick Si(111) bent Laue‐type crystals were used in fixed‐exit beam mode with a 16 mm vertical beam offset and the first crystal water‐cooled. The monochromator operates at energies from 25 to 150 keV, and the measured size of the beam is 189 mm (H) × 8.6 mm (V) at 55 m from the source. This paper presents our approach in developing a complete focusing model of the monochromator. The model uses mechanical properties of crystals and benders to obtain a finite‐element analysis of the complete assembly. The modeling results are compared and calibrated with experimental measurements. Using the developed analysis, a rough estimate of the bending radius and virtual focus (image) position of the first crystal can be made, which is also the real source for the second crystal. On the other hand, by measuring the beam height in several points in the SOE‐1 hutch, the virtual focus of the second crystal can be estimated. The focusing model was then calibrated with measured mechanical properties, the values for the force and torque applied to the crystals were corrected, and the actual operating parameters of the monochromator for fine‐tuning were provided.  相似文献   

13.
Deformation of the first crystal of an X‐ray monochromator under the heat load of a high‐power beam, commonly referred to as `heat bump', is a challenge frequently faced at synchrotron beamlines. Here, quantitative measurements of the deformations of an externally water‐cooled silicon (111) double‐crystal monochromator tuned to a photon energy of 17.6 keV are reported. These measurements were made using two‐dimensional hard X‐ray grating interferometry, a technique that enables in situ at‐wavelength wavefront investigations with high angular sensitivity. The observed crystal deformations were of the order of 100 nm in the meridional and 5 nm in the sagittal direction, which lead to wavefront slope errors of up to 4 µrad in the meridional and a few hundred nanoradians in the sagittal direction.  相似文献   

14.
The development of medium‐energy inelastic X‐ray scattering optics with meV and sub‐meV resolution has attracted considerable efforts in recent years. Meanwhile, there are also concerns or debates about the fundamental and feasibility of the involved schemes. Here the central optical component, the back‐reflection angular‐dispersion monochromator or analyzer, is analyzed. The results show that the multiple‐beam diffraction effect together with transmission‐induced absorption can noticeably reduce the diffraction efficiency, although it may not be a fatal threat. In order to improve the efficiency, a simple four‐bounce analyzer is proposed that completely avoids these two adverse effects. The new scheme is illustrated to be a feasible alternative approach for developing meV‐ to sub‐meV‐resolution inelastic X‐ray scattering spectroscopy.  相似文献   

15.
A heat‐load shutter capable of frequencies from one to several tens of kHz and window times from 10 µs up to 1 ms is described. In the current configuration the water‐cooled shutter absorbs ~99% of the heat generated by the white beam. It has been successfully used for extended periods synchronized with a Jülich pulse‐selector operating at 946 Hz. The temperature of the pulse‐selector remained constant during a three‐day continuous operation. Flexibility is provided by the interchangeability of the chopper disc.  相似文献   

16.
The design and performance of a novel ultra‐high‐vacuum‐compatible artificial channel‐cut monochromator that has been commissioned at undulator beamline 8‐ID‐I at the Advanced Photon Source are presented. Details of the mechanical and optical design, control system implementation and performance of the new device are given. The monochromator was designed to meet the challenging stability and optical requirements of the X‐ray photon correlation spectroscopy program hosted at this beamline. In particular, the device incorporates a novel in‐vacuum sine‐bar drive mechanism for the combined pitch motion of the two crystals and a flexure‐based high‐stiffness weak‐link mechanism for fine‐tuning the pitch and roll of the second crystal relative to the first crystal. The monochromator delivers an exceptionally uniform and stable beam and thereby improved brilliance preservation.  相似文献   

17.
A study of the coherence and wavefront properties of a pseudo‐channel‐cut monochromator in comparison with a double‐crystal monochromator is presented. Using a double‐grating interferometer designed for the hard X‐ray regime, the complex coherence factor was measured and the wavefront distortions at the sample position were analyzed. A transverse coherence length was found in the vertical direction that was a factor of two larger for the channel‐cut monochromator owing to its higher mechanical stability. The wavefront distortions after different optical elements in the beam, such as monochromators and mirrors, were also quantified. This work is particularly relevant for coherent diffraction imaging experiments with synchrotron sources.  相似文献   

18.
Engineering nanostructures from the bottom up enables the creation of carefully sculpted complex structures that are not accessible via top down fabrication techniques, in particular, complex periodic structures for applications in photonics and sensing. In this work a proof of principle that bottom up approach can be adopted and utilized for sculpting devices from diamond is proposed and demonstrated. A realization of periodic structures is achieved by growing nanoscale single crystal diamond through a defined pattern. Optical wave‐guiding of a narrow band emission attributed to the SiV defects in diamond is demonstrated by overgrowth on a thin diamond membrane. In addition, an array of hexagonal microdisks with diameter sizes ranging from 1 to 4 μm is demonstrated. The bottom up approach for diamond opens up new avenues for devices fabrication and sculpting three dimensional structures.  相似文献   

19.
介绍了射流水冷技术并将其应用到高能激光器反射镜的冷却中,设计了射流式水冷镜。采用计算流体力学的方法,利用通用有限元软件ANSYS的流体分析模块FLOTRAN对单孔内射流进行了数值模拟,详细讨论了各孔参数对换热性能的影响,实现了孔参数的优化。结果表明:在水冷镜中采用射流技术可以获得很好的对流换热效果,换热系数可达100 kW/(m2·K)以上,且具有结构简单、可控性强等特点。  相似文献   

20.
The development of a sagittally focusing double‐multilayer monochromator is reported, which produces a spatially extended wide‐bandpass X‐ray beam from an intense synchrotron bending‐magnet source at the Advanced Photon Source, for ultrafast X‐ray radiography and tomography applications. This monochromator consists of two W/B4C multilayers with a 25 Å period coated on Si single‐crystal substrates. The second multilayer is mounted on a sagittally focusing bender, which can dynamically change the bending radius of the multilayer in order to condense and focus the beam to various points along the beamline. With this new apparatus, it becomes possible to adjust the X‐ray beam size to best match the area detector size and the object size to facilitate more efficient data collection using ultrafast X‐ray radiography and tomography.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号