首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到13条相似文献,搜索用时 15 毫秒
1.
Fluorescent X‐ray computed tomography (FXCT) using synchrotron radiation reveals the cross‐sectional distribution of specific elements in biomedical objects. The aim of this study was to investigate the feasibility of FXCT imaging to assess the myocardial metabolic state quantitatively. Hearts labelled with non‐radioactive iodine myocardial fatty acid agent 15‐p‐(iodophenyl)‐3‐methylpentadecanoic acid (BMIPP) from cardiomyopathic and normal hamsters were imaged. FXCT images were compared with optical microscope images. Myocardial fatty acid metabolism enhanced with BMIPP was clearly depicted by FXCT, which showed an almost homogeneous image for normal and a heterogeneous image for cardiomyopathic hearts. Morphological structures of the heart such as the left ventricle and myocardial wall were also visualized by FXCT. Optical microscopy showed no fibrosis in normal and slight interstitial fibrosis in cardiomyopathic hearts. In the case of cardiomyopathy, the area of significantly reduced BMIPP uptake was 39% in the short axis of the mid‐left ventricle in the FXCT image, whereas a slight interstitial fibrosis of around 12% was recognized by optical microscopy for the same slice. This result indicated that reduced BMIPP uptake was caused by the myocardial fatty acid metabolic abnormality, not by the fibrosis in cardiomyopathy. Thus, FXCT images might be used to assess the quantitative metabolic analysis in small animal models of heart diseases.  相似文献   

2.
The ordered‐subsets expectation maximization algorithm (OSEM) is introduced to X‐ray fluorescence computed tomography (XFCT) and studied; here, simulations and experimental results are presented. The simulation results indicate that OSEM is more accurate than the filtered back‐projection algorithm, and it can efficiently suppress the deterioration of image quality within a large range of angular sampling intervals. Experimental results of both an artificial phantom and cirrhotic liver show that with a satisfying image quality the angular sampling interval could be improved to save on the data‐acquisition time when OSEM is employed. In addition, with an optimum number of subsets, the image reconstruction time of OSEM could be reduced to about half of the time required for one subset. Accordingly, it can be concluded that OSEM is a potential method for fast and accurate XFCT imaging.  相似文献   

3.
Phase‐contrast X‐ray imaging using a crystal X‐ray interferometer can depict the fine structures of biological objects without the use of a contrast agent. To obtain higher image contrast, fixation techniques have been examined with 100% ethanol and the commonly used 10% formalin, since ethanol causes increased density differences against background due to its physical properties and greater dehydration of soft tissue. Histological comparison was also performed. A phase‐contrast X‐ray system was used, fitted with a two‐crystal X‐ray interferometer at 35 keV X‐ray energy. Fine structures, including cortex, tubules in the medulla, and the vessels of ethanol‐fixed kidney could be visualized more clearly than that of formalin‐fixed tissues. In the optical microscopic images, shrinkage of soft tissue and decreased luminal space were observed in ethanol‐fixed kidney; and this change was significantly shown in the cortex and outer stripe of the outer medulla. The ethanol fixation technique enhances image contrast by approximately 2.7–3.2 times in the cortex and the outer stripe of the outer medulla; the effect of shrinkage and the physical effect of ethanol cause an increment of approximately 78% and 22%, respectively. Thus, the ethanol‐fixation technique enables the image contrast to be enhanced in phase‐contrast X‐ray imaging.  相似文献   

4.
Using X‐ray fluorescent computed tomography (XFCT), the in vivo and ex vivo cerebral distribution of a stable‐iodine‐labeled cerebral perfusion agent, iodoamphetamine analog (127I‐IMP), has been recorded in the brains of mice. In vivo cerebral perfusion in the cortex, hippocampus and thalamus was depicted at 0.5 mm in‐plane spatial resolution. Ex vivo XFCT images at 0.25 mm in‐plane spatial resolution allowed the visualisation of the detailed structures of these regions. The quality of the XFCT image of the hippocampus was comparable with the 125I‐IMP autoradiogram. These results highlight the sensitivity of XFCT and its considerable potential to evaluate cerebral perfusion in small animals without using radioactive agents.  相似文献   

5.
Visualization of the microvascular network and thrombi in the microvasculature is a key step to evaluating the development of tumor growth and metastasis, and influences treatment selection. X‐ray phase‐contrast computed tomography (PCCT) is a new imaging technique that can detect minute changes of density and reveal soft tissues discrimination at micrometer‐scale resolution. In this study, six human resected hepatocellular carcinoma (HCC) tissues were investigated with PCCT. A histological stain was added to estimate the accuracy of PCCT. The results showed that the fine structures of the microvasculature (measuring 30–100 µm) and thrombi in tiny blood vessels were displayed clearly on imaging the HCC tissues by PCCT. Moreover, density distributions of the thrombi were obtained, which could be reliably used to distinguish malignant from benign thrombi in HCC. In conclusion, PCCT can clearly show the three‐dimensional subtle structures of HCC that cannot be detected by conventional absorption‐based computed tomography and provides a new method for the imageology of HCC.  相似文献   

6.
In‐line X‐ray phase‐contrast computed tomography (IL‐PCCT) can reveal fine inner structures for low‐Z materials (e.g. biological soft tissues), and shows high potential to become clinically applicable. Typically, IL‐PCCT utilizes filtered back‐projection (FBP) as the standard reconstruction algorithm. However, the FBP algorithm requires a large amount of projection data, and subsequently a large radiation dose is needed to reconstruct a high‐quality image, which hampers its clinical application in IL‐PCCT. In this study, an iterative reconstruction algorithm for IL‐PCCT was proposed by combining the simultaneous algebraic reconstruction technique (SART) with eight‐neighbour forward and backward (FAB8) diffusion filtering, and the reconstruction was performed using the Shepp–Logan phantom simulation and a real synchrotron IL‐PCCT experiment. The results showed that the proposed algorithm was able to produce high‐quality computed tomography images from few‐view projections while improving the convergence rate of the computed tomography reconstruction, indicating that the proposed algorithm is an effective method of dose reduction for IL‐PCCT.  相似文献   

7.
One of the most fascinating objects in the Rijksmuseum (Amsterdam, The Netherlands) is an early 16th century prayer nut. This spherical wooden object measures 4 cm in diameter and consists of two hemispheres connected with a small hinge so that it can be opened. The interior of the nut holds wood carvings with scenes from the life of Christ. These miniature reliefs show an incredible degree of finish with carving details well beyond the millimetre scale. In the present paper it is shown how synchrotron‐based computer X‐ray tomography revealed the structure and fabrication method of the bead. The central part of the relief was cut from a single piece of wood, rather than assembled from multiple components, underlining the extraordinary manual dexterity of its maker. In addition, a piece of fibrous material contained in the inner structure of the bead is revealed. This may have served as a carrier for an odorous compound, which would be in line with the religious function of the prayer nut.  相似文献   

8.
A method for radionuclide‐induced (109Cd) energy‐dispersive X‐ray fluorescent (EDXRF) was used to determine Br, Fe, Rb, Sr, and Zn contents in intact and morphologic normal prostate tissues. Prostates were removed at necropsy from 64 men (mean age 36.5 years, range 13–60) who had died suddenly. All materials were divided into two parts. One part was morphologically examined, whereas chemical element contents of the other were estimated. Mean values (M ± SΕΜ) for mass fraction of Br, Fe, Rb, Sr, and Zn (mg kg?1 on dry‐weight basis) in the intact and morphologic normal prostate tissue were 35.5 ± 4.0, 107 ± 5.4, 17.1 ± 0.8, 1.9 ± 0.3, and 850 ± 79, respectively. Mean values (M ± SΕΜ) for Zn/Fe, Zn/Rb, and Zn/Sr ratios of mass fraction were 8.72 ± 0.80, 57.4 ± 7.2, and 567 ± 82, respectively. A strongly pronounced tendency of age‐related exponential increase in Zn mass fraction as well an increase in Zn/Fe, Zn/Rb, and Zn/Sr ratios in prostate was observed. A significant positive correlation was seen between the prostatic zinc and iron contents (p ≤ 0.05, r = 0.22) and between the prostatic zinc and bromine contents (p ≤ 0.01, r = 0.43). Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
High‐resolution analyser‐based X‐ray imaging computed tomography (HR ABI‐CT) findings on in vitro human breast cancer are compared with histopathology, mammography, computed tomography (CT) and magnetic resonance imaging. The HR ABI‐CT images provided significantly better low‐contrast visibility compared with the standard radiological images. Fine cancer structures indistinguishable and superimposed in mammograms were seen, and could be matched with the histopathological results. The mean glandular dose was less than 1 mGy in mammography and 12–13 mGy in CT and ABI‐CT. The excellent visibility of in vitro breast cancer suggests that HR ABI‐CT may have a valuable role in the future as an adjunct or even alternative to current breast diagnostics, when radiation dose is further decreased, and compact synchrotron radiation sources become available.  相似文献   

10.
Liquid water produced in a polymer electrolyte membrane fuel cell experiences a freeze/thaw cycle when the cell is switched off and on while operating at ambient temperatures below freezing. This freeze/thaw cycle permanently deforms the polymer electrolyte membrane fuel cell capillary structures and reduces both the cell life and its ability to generate electric power. The X‐ray tomography facility at the Pohang Accelerator Laboratory was used to observe the freeze/thaw effects on the gas diffusion layer (GDL), which is the thickest capillary layer in the cell. Morphological changes in the GDL under a water freeze/thaw cycle were observed. A scenario in which freeze/thaw cycles affect fuel cell performance is suggested based on images from X‐ray tomography.  相似文献   

11.
X‐ray magnetic circular dichroism (XMCD) has become in recent years an outstanding tool for studying magnetism. Its element specificity, inherent to core‐level spectroscopy, combined with the application of magneto‐optical sum rules allows quantitative magnetic measurements at the atomic level. These capabilities are now incorporated as a standard tool for studying the localized magnetism in many systems. However, the application of XMCD to the study of the conduction‐band magnetism is not so straightforward. Here, it is shown that the atomic selectivity is not lost when XMCD probes the delocalized states. On the contrary, it provides a direct way of disentangling the magnetic contributions to the conduction band coming from the different elements in the material. This is demonstrated by monitoring the temperature dependence of the XMCD spectra recorded at the rare‐earth L2‐edge in the case of RT2 (R = rare‐earth, T = 3d transition metal) materials. These results open the possibility of performing element‐specific magnetometry by using a single X‐ray absorption edge.  相似文献   

12.
The experimental procedure for obtaining the point spread function (PSF) of a focusing beam generated using an X‐ray multilayer zone plate (MZP) with a narrow annular aperture has been developed. It was possible to reconstruct the PSF by applying the tomographic process to the measured dataset consisting of line spread functions (LSFs) in every radial direction on the focal plane. The LSFs were measured by a knife‐edge scanning method of detecting scattered intensity. In the experimental work, quasi‐monochromatic undulator radiation with a first harmonic energy of 20 keV was directly focused without a monochromator by the MZP, and the PSF was measured using this procedure. As a result, a near diffraction‐limited focused beam size of 46 nm full width at half‐maximum was obtained.  相似文献   

13.
Carbon contamination of optics is a serious issue in all soft X‐ray beamlines because it decreases the quality of experimental data, such as near‐edge X‐ray absorption fine structure, resonant photoemission and resonant soft X‐ray emission spectra in the carbon K‐edge region. Here an in situ method involving the use of oxygen activated by zeroth‐order synchrotron radiation was used to clean the optics in a vacuum ultraviolet and soft X‐ray undulator beamline, BL‐13A at the Photon Factory in Tsukuba, Japan. The carbon contamination of the optics was removed by exposing them to oxygen at a pressure of 10?1–10?4 Pa for 17–20 h and simultaneously irradiating them with zeroth‐order synchrotron radiation. After the cleaning, the decrease in the photon intensity in the carbon K‐edge region reduced to 2–5%. The base pressure of the beamline recovered to 10?7–10?8 Pa in one day without baking. The beamline can be used without additional commissioning.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号