相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
An annular helium inductively coupled plasma (He ICP) was generated at atmospheric pressure. No external cooling was used to stabilize the plasma. Aqueous solution was injected into the plasma without any difficulty. Preliminary results revealed that the annular He ICP was capable of exciting elements such as Cl and Br which possess high excitation energies. Atomic emission detection limits for Cl and Br were improved by factors of 63 and 34, respectively, as compared to the results obtained from the argon inductively coupled plasma. The excitation temperature of the annular He ICP (4180 K) was less than that of an Ar ICP (5570 K).  相似文献   

3.
Calibration is a crucial step during the whole analytical process. A procedure is suggested to assess the quality of linear regression used for the calibration graph, based on the use of confidence limits for the concentration, as the regression coefficient is not appropriate for this purpose. This procedure has been applied to inductively coupled plasma atomic emission spectrometry. It indicates that the use of only three standards should be discouraged because of unacceptably high confidence limits for the concentration. Moreover, use of weighted regression is more adequate in performing the least squares method and provides more constant confidence limits over the concentration range used to construct the calibration graph. This procedure could be easily added to any commercially available ICP system software.  相似文献   

4.
In Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES), it has been observed that the emission intensity of some atomic lines is enhanced or depressed by the presence of carbon in the matrix. The goal of this work was to investigate the origin and magnitude of the carbon-related matrix effects in ICP-AES. To this end, the influence of the carbon concentration and source (i.e. glycerol, citric acid and potassium hydrogen phthalate), the experimental conditions and sample introduction system on the aerosol characteristics and transport, plasma excitation conditions and the emission intensity of several atomic and ionic lines of a total of 15 elements has been studied. Results indicate that carbon related matrix effects do not depend on the carbon source and they become more severe when the amount of carbon loaded into the plasma increases, i.e., when using: (i) carbon concentrations higher than 5 g L− 1; (ii) high sample uptake rates; and (iii) efficient sample introduction systems. Thus, when introducing carbon into the plasma, the emission intensity of atomic lines with excitation energies below 6 eV is depressed (up to 15%) whereas the emission intensity of atomic lines of higher excitation energies (i.e. As and Se) are enhanced (up to 30%). The emission intensity of the ionic lines is not affected by the presence of carbon. The origin of the carbon-related interferences on the emission intensity of atomic lines is related to changes in the line excitation mechanism since the carbon containing solutions show the same aerosol characteristics and transport efficiencies as the corresponding aqueous solutions. Based on the previous findings, a calibration approach for the accurate determination of Se in a Se-enriched yeast certified material (SELM-1) has been proposed.  相似文献   

5.
Investigations were carried out on the optimization of excitation and projection conditions of the axially-observed inductively coupled plasma (ICP) concerning simultaneous measurements. For minimized background equivalent concentration (BEC) it can be shown that the optimal excitation conditions of the atomic and ionic lines also vary in the case of axial plasma observation. A relationship was confirmed between the high frequency power and the excitation energy of the analytical lines. The main contribution of this work is the displacement of the axial viewing inductively coupled plasma by means of an x,y,z sliding carriage.The displacement showed that under the selected experimental conditions the point of observation is spatially identical for all analytical lines. Received: 30 May 1997 / Revised: 20 November 1997 / Accepted: 25 November 1997  相似文献   

6.
Investigations were carried out on the optimization of excitation and projection conditions of the axially-observed inductively coupled plasma (ICP) concerning simultaneous measurements. For minimized background equivalent concentration (BEC) it can be shown that the optimal excitation conditions of the atomic and ionic lines also vary in the case of axial plasma observation. A relationship was confirmed between the high frequency power and the excitation energy of the analytical lines. The main contribution of this work is the displacement of the axial viewing inductively coupled plasma by means of an x,y,z sliding carriage.The displacement showed that under the selected experimental conditions the point of observation is spatially identical for all analytical lines. Received: 30 May 1997 / Revised: 20 November 1997 / Accepted: 25 November 1997  相似文献   

7.
To optimize the atomization and ionization processes in an inductively coupled plasma used as a source in atomic emission spectrometry, the Mg II 280.270-nm/Mg I 285.213-nm line intensity ratio is used. A theoretical ratio is calculated assuming a local thermodynamic equilibrium. A review of previously published experimental values of the ratio is given as a function of the parameters influencing the energy transfer between the plasma and the injected species. In particular, the effects of the power, the carrier gas flow-rate, the i.d. of the torch injector, the use of a sheathing gas and the presence of hydrogen are described. Values of the ratio close to the theoretical values are obtained with the use of a high power (> 1.4 kW), a low carrie gas flow-rate (< 0.6 1 min?1 and a large i.d. of the injector (> 2 mm). This optimization can also be applied to the minimization of interference effects due to the presence of sodium.  相似文献   

8.
Correlation studies (calculation of the cross-correlation function and correlation coefficients) were carried out between fluctuations in the emission signals from various analyte and internal standard elements. Some statistics are presented which may help give a clearer picture of the utility of the internal standard principle. Improvements in precision brought about by the use of suitable standards are in the region of a factor of two. The use of argon emission lines as internal standards does not prove effective as an inverse correlation is observed between the emission of these lines and analyte lines.  相似文献   

9.
Summary The enhancement factors of various organic solvents in inductively coupled plasma atomic emission spectrometry (ICP-AES) were measured for diethyldithiocarbamate-cadmium(II) or mercury(II)-solvent systems by comparing the maximum emission intensity of an extract with that of the corresponding aqueous solution. The correlation between the enhancement factors obtained and physical parameters of the solvents were investigated. Among them, the best inverse linear relationship existed between log dielectric constant and log enhancement factor. The plot of log (boiling point x viscosity) vs. log enhancement factor also resulted in a line with a negative slope except water. Carbon tetrachloride, chlorofom and xylene, which gave much larger enhancement factors, were recommended for the use in ICP-AES.
Verstärkungseffekt durch organische Lösungsmittel in der ICP-AES
  相似文献   

10.
A PTFE Babingtonnebulizer equipped with a hood was investigated for inductively coupled plasma atomicemission spectrometry in conjunction with a PTFE cyclone chamber, in order to nebulize various sample solutions containing high salts, hydrofluoric acid and/or suspended solid. A hood of 3 mmphi (nozzle side) - 5 mmphi (outlet side) and 6 mm in length gave a comparable or higher sensitivity compared to a system with a commercially available concentric nebulizer and a glass cyclone chamber. Moreover, the present nebulizer was fully interchangeable with a concentric one at normal argon pressure, attaining sufficient stability, a short wash-out time and good nebulizing of high matrices solutions. The present system was successfully applied to the determination of trace impurities in highly pure silica powders.  相似文献   

11.
An inductively coupled plasma atomic emission spectrometry (ICP-AES) method was developed for the determination of phosphorus in fertilizers. Total phosphorus, direct extraction available phosphorus (EDTA), and water-soluble phosphorus, reported as phosphorus pentoxide (P205), in 15 Magruder check fertilizers were measured by ICP-AES, and the results were compared with those obtained by the AOAC official method. Five analytical wavelengths of phosphorus, 177.499, 178.287, 213.618, 214.914, and 253.565 nm, were tested for the determination of phosphorus in fertilizers, and their detection limits were obtained. Acid effects of perchloric acid and possible matrix effects of aluminum, calcium, magnesium, potassium, and sodium were negligible for phosphorus determination. Wavelength 213.618 nm was the best analytical wavelength for phosphorus determination by all 3 sample preparation methods for the selected Magruder fertilizers. The results demonstrated that the accuracy and precision of the ICP-AES method were comparable with those of the official methods.  相似文献   

12.
A background correction method based on wavelet transform was devised and applied to inductively coupled plasma atomic emission spectrometry (ICP-AES). The proposed approach separated background from analyte signal according to their different frequencies. Compared with the analyte signal, the background has a low frequency. By removal of the components attributed to the signal, the background over the spectral window of the analyte line can be fitted through wavelet reconstruction. The results showed that the wavelet transform technique could handle all kinds of background and low signal-to-background ratio spectra, and required no prior knowledge about the sample composition, no selection of suitable background correction points, and no mathematical assumption of the background distribution. This technique performed as well as the conventional three-point background correction method for linear backgrounds, and provided better results than the latter for curved backgrounds. The proposed procedure was illustrated, by processing real spectra, to be an effective and practical tool for background correction in ICP-AES.  相似文献   

13.
A modified concentric nebulizer was used as the interface to couple capillary electrophoresis (CE) to inductively coupled plasma atomic emission spectrometry (ICP-AES). The CE capillary replaces the central tube of the concentric nebulizer. The tip of the nebulizer tapers slowly to allow uncertainty in the position of the capillary. A platinum wire was inserted into the CE capillary to provide electrical connection to the CE power supply. pH changes inside the capillary due to electrolysis of the background buffer electrolyte was small and has minimal effects on the CE separation. The peak broadening effects due to the nebulizing gas flow, however, were significant. Resolution decreases quickly when the flow-rate of the carrier gas increases. Sample stacking technique was used to improve the resolution of species of opposite charge, e.g., Cr(VI) vs. Cr(III) ions. Detection limit of Cr based on peak area is approximately 10 ppb for the CE-ICP-AES system.  相似文献   

14.
In order to study matrix effects and efficiency of internal standardization with an axially-viewed ICP-AES system, a large number of elements with atomic lines in the 2.9–7.8-eV excitation energy range and ionic lines in the 7.7–16.5-eV energy sum range were selected and matrix effects were evaluated using a multichannel detector having a wavelength coverage in the range 167–785 nm. Na and Ca were selected as interferent elements at a concentration of up to 10 g l−1, along with nitric acid, up to a concentration of 20% (v/v). Several operating conditions were used, ranging from robust conditions (1500 W, 0.65 l min−1 for the carrier gas) to non-robust conditions (800 W, 1.2 l min−1). Under robust conditions, a rather flat, depressive effect was observed for ionic lines and atomic lines. This depressive effect was mainly assigned to the aerosol transport and filtering phenomena and was element or acid concentration-dependent. Within this depressive effect, some small departures from the flat effect were observed. However, these small effects exhibited the same patterns over the interferent element concentration range of 1–10 g l−1, i.e. these effects were shifted as a function of the interferent concentration rather than multiplied. A consequence is that internal standardization to compensate for matrix effects on ionic lines was found to be more efficient when based on additive (i.e. shift) effects rather than on multiplicative (i.e. proportional) effects. Under non-robust conditions, signal compensation was found to be inefficient.  相似文献   

15.
Rapid sequential atomic emission spectrometry with the ‘Zig Zag’ acquisition system (ISA Jobin Yvon, France) in the case of the inductively coupled plasma is described. The ‘Zig Zag’ system is shown to enable the application of spectral stripping, as both the reproducibility of the intensities measured, for several lines of Fe, and the reproducibilty of the wavelength positioning (errors below 3 pm in the 2nd order and 5 pm in the 1st order) were found to be high. Using an integration time of only 2.5 ms/point, the precision of the intensities expressed as the relative standard deviation is below 5%. These features are shown to allow spectrum stripping from the contribution of a Zr matrix, which has a rather line-rich atomic emission spectrum. Spectrum stripping was applied in the wavelength range from 237.9 to 241.1 nm, where 10 of the most sensitive emission lines of Fe were found. For sample solutions with 500 mg/l Zr only, 10 mg/l Fe only, 500 mg/l Zr as well as 10 mg/l Fe, and for a blank solution, respectively, five spectral scans were averaged and the averaged spectral scan for a blank solution was subtracted. The spectral scan obtained for a solution containing 500 mg/l Zr only was subtracted from the one obtained for the solution containing both 500 mg/l Zr and 10 mg/l Fe. The result of spectral stripping is comparable to the experimentally obtained spectral scan for the solution containing 10 mg/l Fe only after blank subtraction. The recovery for Fe was found to be 93±2% and is therefore comparable to the one obtained by chemical separation methods using solvent extraction. When using an integration time of 50 ms per measurement point instead of 0.5 ms/point, as it is possible in the case of the ‘Zig Zag’ approach, the detection limit for Fe in the measurement solutions can be improved from 20 down to 3 μg/l, or from 40 to 6 μg/g Zr, respectively.  相似文献   

16.
Zusammenfassung Nadelproben werden in einem Druckaufschlu\gefÄ\ mit SalpetersÄure aufgeschlossen und die erhaltenen Lösungen mittels ICP-AES auf Schwefel analysiert. Die Messung erfolgt bei 182,04 nm in einem mit Stickstoff gespülten Spektrometer. Die Ergebnisse korrelieren gut mit unabhÄngigen Bestimmungen durch Wickbold-Aufschlu\ und Ionen-Chromatographie. Das Verfahren hat den Vorteil, da\ keine Verluste des Analysenelements auftreten und da\ die Aufschlu\lösung auch für die simultane Bestimmung von Spurenmetallen mit der ICP-AES geeignet ist.  相似文献   

17.
18.
A procedure employing inductively coupled plasma atomic emission spectroscopy has been developed for the precise determination of the composition of Zn1 + xGe1 + xP2 + x alloys after their autoclave digestion. An optimal composition of the acid mixture has been chosen and the conditions preventing element losses in the digestion process have been found. To minimize the error of the developed procedure, the optimal concentration of Zn, Ge, and P in the analytes was found by calculating the results of analysis as atomic ratios Zn : Ge and P : Ge. The accuracy of the developed procedure was confirmed by the standard addition method and the comparison of the results with the results of an independent method. The relative standard deviation of the determination of atomic ratios was 0. 7–2.0%.  相似文献   

19.
A method is proposed for plotting calibration graphs by reference analyte solutions (tandem calibration) for the analysis of steels and alloys by inductively coupled plasma atomic emission spectrometry (ICP-AES) with spark ablation. The use of spectral lines of analytes and an internal standard with similar values of sums of ionization and excitation energy ensures an excellent repeatability and accuracy of the results of analysis using tandem calibration. A nebulizer chamber for the simultaneous introduction of solutions and solid sample aerosols into inductively coupled plasma (ICP) is designed. The optimal parameters of the introduction of sample aerosols and a method of plasma observation are chosen; the requirements for the choice of the analytical lines of analytes are proposed.  相似文献   

20.
建立电感耦合等离子体原子发射光谱法(ICP-AES)测定钛合金中锆元素的含量。采用盐酸-氢氟酸-硝酸溶解钛合金样品,选择357.247 nm为锆的分析谱线,通过基体匹配法消除基体钛的干扰,以电感耦合等离子体原子发射光谱法测定钛合金中锆的含量。锆的质量分数在0%~0.4%范围内与光谱强度呈良好的线性关系,相关系数大于0.999,定量下限为0.21%。测定结果的相对标准偏差小于2%(n=11),样品加标回收率为99.0%~102.7%。该方法快速、准确,能够满足实际生产中钛合金样品的测定要求。  相似文献   