首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
He Q  Zhu Z  Hu S  Jin L 《Journal of chromatography. A》2011,1218(28):4462-4467
A novel solution cathode glow discharge (SCGD) induced vapor generation was developed as interface to on-line couple high-performance liquid chromatography (HPLC) with atomic fluorescence spectrometry (AFS) for the speciation of inorganic mercury (Hg(2+)), methyl-mercury (MeHg) and ethyl-mercury (EtHg). The decomposition of organic mercury species and the reduction of Hg(2+) could be completed in one step with this proposed SCGD induced vapor generation system. The vapor generation is extremely rapid and therefore is easy to couple with flow injection (FI) and HPLC. Compared with the conventional HPLC-CV-AFS hyphenated systems, the proposed HPLC-SCGD-AFS system is very simple in operation and eliminates auxiliary redox reagents. Parameters influencing mercury determination were optimized, such as concentration of formic acid, discharge current and argon flow rate. The method detection limits for HPLC-SCGD-AFS system were 0.67 μg L(-1) for Hg(2+), 0.55 μg L(-1) for MeHg and 1.19 μg L(-1) for EtHg, respectively. The developed method was validated by determination of certified reference material (GBW 10029, tuna fish) and was further applied for the determination of mercury in biological samples.  相似文献   

2.
汞与碘化亚铜的络合显色反应已被广泛应用于汞的可视化检测。然而,样品中高盐、强酸或强碱性的复杂基质对碘化亚铜及络合物的稳定性影响较大,可视化测定受到了严重干扰。光化学蒸气发生是一种绿色、高效的样品引入技术,可实现待测离子与样品基质的有效分离,并且在蒸气发生过程中不需要添加有毒、强还原性试剂。因此,本实验建立了一种光化学蒸气发生和自制碘化亚铜试纸结合用于可视化检测水样中汞的方法,对反应时间、低分子量有机酸浓度等条件进行了考察。在最优的条件下实现了1 ng·mL^-1~1μg·mL^-1浓度范围内水样中汞的可视化半定量分析,并通过原子荧光光谱法对分析结果进行了验证。  相似文献   

3.
In this work a procedure for mercury determination by Flow Injection-Cold Vapor Generation-Inductively Coupled Plasma Optical Emission Spectrometry (FI-CVG-ICP OES) has been developed. The system uses a small homemade glass separator constructed to drive the Hg vapor to the plasma. An evolutionary operation factorial design was used to evaluate the optimal experimental conditions for mercury vapor generation, aiming at the low consumption of reagents, the improvement of the analytical signal and consequently greater sensitivity. The procedure allowed the determination of mercury and showed excellent linearity for the concentration range from 0.50 μg L(-1) to 100.0 μg L(-1), with Limits of Detection (LOD) and Quantification (LOQ) of 0.11 μg L(-1) and 0.36 μg L(-1), respectively, and a sampling rate of 36 analyses per hour. The optimized procedure showed good accuracy and precision, and the method was validated by the analysis of two certified reference materials: Buffalo River Sediment (NIST 2704) and human hair (IAEA 085). A good agreement with the certified values was achieved, with recovery values of 99% and 98% and relative standard deviation close to 2%.  相似文献   

4.
A new method was proposed for the accurate determination of mercury in cosmetic samples based on isotopic dilution (ID)-photochemical vapor generation (PVG)-inductively coupled plasma mass spectrometry (ICP MS) measurement. Cosmetic samples were directly dissolved in formic acid solution and subsequently subjected to PVG for the reduction of mercury into vapor species following by ICP MS detection. Therefore, the risks of analyte contamination and loss were avoided. Highly enriched 201Hg isotopic spike is added to cosmetics and the isotope ratios of 201Hg/202Hg were measured for the quantitation of mercury. With ID calibration, the influences originating from sample matrixes for the determination of mercury in cosmetic samples have been efficiently eliminated. The effects of several experimental parameters, such as the concentration of the formic acid, and the flow rates of carrier gas and sample were investigated. The method provided good reproducibility and the detection limits were found to be 0.6 pg mL−1. Finally, the developed method was successfully applied for the determination of mercury in six cosmetic samples and a spike test was performed to verify the accuracy of the method.  相似文献   

5.
In this paper, a novel automatic approach for the speciation of inorganic mercury (Hg(2+)), methylmercury (MeHg(+)) and ethylmercury (EtHg(+)) using multisyringe chromatography (MSC) coupled to cold-vapor atomic fluorescence spectrometry (CV/AFS) was developed. For the first time, the separation of mercury species was accomplished on a RP C18 monolithic column using a multi-isocratic elution program. The elution protocol involved the use of 0.005% 2-mercapthoethanol in 240 mM ammonium acetate (pH 6)-acetonitrile (99:1, v/v), followed by 0.005% 2-mercapthoethanol in 240 mM ammonium acetate (pH 6)-acetonitrile (90:10, v/v). The eluted mercury species were then oxidized under post-column UV radiation and reduced using tin(II) chloride in an acidic medium. Subsequently, the generated mercury metal were separated from the reaction mixture and further atomized in the flame atomizer and detected by AFS. Under the optimized experimental conditions, the limits of detection (3σ) were found to be 0.03, 0.11 and 0.09 μg L(-1) for MeHg(+), Hg(2+) and EtHg(+), respectively. The relative standard deviation (RSD, n=6) of the peak height for 3, 6 and 3 μg L(-1) of MeHg(+), Hg(2+) and EtHg(+) (as Hg) ranged from 2.4 to 4.0%. Compared with the conventional HPLC-CV/AFS hyphenated systems, the proposed MSC-CV/AFS system permitted a higher sampling frequency and low instrumental and operational costs. The developed method was validated by the determination of a certified reference material DORM-2 (dogfish muscle), and was further applied for the determination of mercury species environmental and biological samples.  相似文献   

6.
该文合成了2,3-二氢-9,10-二羟基-1,4-蒽醌(R),并借助核磁共振谱、红外光谱、质谱及紫外光谱等方法确定其结构.基于R在醋酸纤维素膜固体基质上能产生强而稳定的固体基质室温燐光(SS-RTP),α,α'-联吡啶可活化Hg2+催化H2O2氧化R转化成无燐光化合物,导致固体基质室温燐光急剧猝灭,建立了催化H2O2氧...  相似文献   

7.
Li X  Wang Z 《Analytica chimica acta》2007,588(2):179-183
A novel method for determination of mercury was developed using an intermittent flow electrochemical cold vapor generation coupled to atomic fluorescence spectrometry (IF-ECVG-AFS). The mercury vapor was generated on the surface of glassy carbon cathode in the flow cell. The operating conditions for the electrochemical generation of mercury vapor were investigated in detail, and the interferences from various ions were evaluated. Under the optimized conditions, no evident memory effects of mercury were observed. The calibration curve was linear up to 5 μg L−1 Hg at 0.54 A cm−2. A detection limit of 1.2 ng L−1 Hg and a relative standard deviation of 1.8% for 1 μg L−1 Hg were obtained. The accuracy of method was verified by the determination of mercury in the certified reference human hair. The ECVG avoided the use of reductants, thereby greatly reducing the contamination sources. In addition, the manifold of IF-ECVG-AFS was simple and amenable to automation.  相似文献   

8.
A sodium montmorillonite (SWy-2)-modified carbon-paste electrode has been examined for determination of trace levels of mercury. Because of its strong cation-exchange and adsorptive characteristics, SWy-2 greatly improves the sensitivity of determination of Hg(2+). Hg(2+) is preconcentrated and reduced on the modified electrode surface at -0.40 V and then stripped from the electrode surface during the positive potential sweep. The conditions used for determination, e.g. supporting electrolyte, pH, amount of SWy-2, accumulation potential, and accumulation time, were optimized. The peak current was linearly dependent on the concentration of mercury from 1 x 10(-9) to 5 x 10(-7) mol L(-1). The detection limit (signal-to-noise ratio=3) was 1 x 10(-10) mol L(-1) after accumulation for 6 min. When the SWy-2-modified carbon-paste electrode was used to detect mercury in water samples the average recovery was 101.11%.  相似文献   

9.
A procedure using an automated microwave flow digestion technique was developed and validated for the digestion of samples of certifiable color additives before mercury determination by cold vapor atomic absorption spectrometry. Recovery studies were performed by spiking most of the color additives subject to batch certification by the U.S. Food and Drug Administration with inorganic mercury (HgNO3) and with organic mercury (CH3HgCl). Successful recoveries of 72-113% Hg added at the 1 microg/g level were obtained. A method detection limit of 0.2 microg Hg/g was estimated from a Hg-spiked FD&C Yellow No. 6 sample. At the specification level of 1 ppm Hg (1 microg Hg/g), the 95% confidence interval was +/- 0.2 ppm (0.2 microg Hg/g).  相似文献   

10.
Li Z  Yang X  Guo Y  Li H  Feng Y 《Talanta》2008,74(4):915-921
Chemical vapor generation (CVG) coupled with non-dispersive atomic fluorescence spectrometry (NDAFS) has been widely used for determination of vapor-forming elements, but most of such works have been focused on single element analysis, and reports dealing with more than three elements simultaneous determination by CVG-NDAFS are rare. In this work, a sensitive and robust analytical procedure for the simultaneous determination of arsenic, antimony, bismuth and mercury in geological materials using vapor generation-four-channel non-dispersive atomic fluorescence spectrometry has been developed. The conditions of instrumentation and vapor generation of arsenic, antimony, bismuth and mercury were optimized. The optimized concentrations of KBH(4) and HCl required for analytes generation were 1.3% (m/v) and 20% (v/v), respectively. The interferences of coexisting ions and mutual hydride interferences were investigated carefully. One thousand milligrams per litre of Fe(3+); 500mgl(-1) of Pb(2+), Zn(2+), Mn(2+); 50mgl(-1) Cu(2+), Ni(2+), Cr(6+), Co(2+); 10mgl(-1) Ag(+) and 5mgl(-1) Au(3+) does not interfere with the determination of As, Sb, Bi and Hg. Associating a dilution of 1:250 (m/v) in the procedure of sample pretreatment, the tolerant concentrations of As, Sb, Bi and Hg in real geological materials are 2500, 1000, 250 and 5000ppm, respectively. Under optimal conditions, the detection limits for As, Sb, Bi and Hg were determined to be 0.068, 0.047, 0.037 and 0.008ngml(-1), respectively. The precisions for seven replicate determinations at the 5ngml(-1) of As, Sb, Bi and 1ngml(-1) of Hg were 0.47, 0.60, 0.97 and 0.93% (R.S.D.), respectively. Sample digestion was carried out on 500mg sample with 3ml HNO(3) and 10ml HCl, followed by addition of thiourea solution for the quantitative reduction of As(V), Sb(V) to As(III), Sb(III). The proposed method was successfully applied to the simultaneous determination of As, Sb, Bi and Hg in a series of certified geological reference materials using simple aqueous standard calibration technique. The results obtained are in good agreement with the certified values.  相似文献   

11.
Low recovery rate and inconsistent measurements were found in the determination of mercury by method of cold vapor atomic absorption spectrophotometry using the hydride formation system (Hitachi HFS-2, Hitachi Ltd., Tokyo). To overcome this problem of insufficient reaction time we developed a simple T-joint device attaching to the commercial HFS-2 system for the determination of mercury in various biological tissues and sediment samples. The T-joint device was designed to combine sample and reductant injection which increased the reaction time of the sample allowing a complete formation of mercury vapor and speeding up the analysis process in comparison to the traditional cold vapor atomic absorption spectrometric method. Recoveries of mercury were in the range 95% - 100%. The corrected procedure gave precise and accurate readings with several certified reference materials: NIES No. 2 from the Japan Environment Agency; IAEA-356 from the International Atomic Energy Association, and DOLT-2, DORM-2, TORT-2, PACS-1 and MESS-2 from the National Research Council of Canada. Simple acid digestion methods were developed based on the sample Hg level and the nature of the sample. The sample detection limits were 0.0125 μg g−1 fresh weight and 0.0625 μg g−1 dry weight for biological samples, and as low as 0.0125 μg g−1 dry weight for sediment samples. These analytical protocols we established met the general requirements in environmental research and monitoring of mercury pollution.  相似文献   

12.
A sequential injection (SI) method for the determination of mercury via cold vapor atomic absorption spectrophotometry is presented. The method differs from flow injection (FI) cold vapor methods for the determination of mercury because of the simplicity of the system required for the method: one pump, one valve, a gas-liquid separator, and an atomic absorption spectrophotometer equipped with a quartz cell. Under optimal conditions, the method has the following figures of merit: a linear ¶calibration range of 1.0 to 20 μg L–1; a detection limit of 0.46 μg L–1; and a precision of 0.90% RSD (8 μg L–1). The procedure allows for a sampling rate of one injection per 80 s (excluding sample pretreatment). Results from the determination of mercury in water and fish specimens are also presented. The figures of merit of the method are compared to two other SI methods for the determination of mercury.  相似文献   

13.
The fluorimetric determination of mercury ions with o-vanillin-8-aminoquinoline (OVAQ) in aqueous solutions was investigated. Hg(II) could react with the fluorescent reagent OVAQ (λex/em = 278/314 nm) to form a nonfluorescent complex in an ethanol-water medium of pH 6.00. The linear range of the proposed method was from 2.5 to 80 μg/L, and the detection limit was 0.80 μg/L. The interferences of 24 foreign ions were also studied. The method was successfully applied to the determination of Hg(II) in sludge. The text was submitted by the authors in English.  相似文献   

14.
建立合并通道–原子荧光光谱法测定地表水中超痕量汞的分析方法。采用微孔滤膜过滤、盐酸酸化处理地表水,以合并通道技术提高原子化效率,研究了合并通道对灵敏度以及检出限的影响。在优化的实验条件下,汞含量在0~2μg/L范围内与原子荧光响应值呈良好的线性关系,相关系数为0.999 1,检出限为0.000 3μg/L,测定结果的相对标准偏差小于5%(n=7),加标回收率在82.0%~110.0%之间。该法准确可靠,检出限低,可用于地表水中超痕量汞的检测。  相似文献   

15.
采用具有高气体渗透性和紫外光透过性的无定形聚四氟乙烯管(Teflon AF-2400)作为蒸气发生原子荧光系统的气液分离器和检测池,建立了微型化汞蒸气发生原子荧光检测系统。考察了Teflon AF-2400管长度、还原剂种类和浓度、酸介质种类和浓度、进样流速以及氩气流速对测量体系的影响。在优化实验条件下,该方法的线性范围为0.07~10μg/L(r=0.998 0),检出限为0.02μg/L,相对标准偏差(n=11)为3.3%。该系统体积小、样品消耗少、灵敏度高。方法已成功应用于卷烟样品中汞含量的检测,回收率为97%~102%。  相似文献   

16.
将金精矿粉样品直接置于石英舟中,在高纯氧气氛中燃烧,释放出汞,与齐化管中的金形成金汞齐,于900℃热释放出汞蒸汽,用直接测汞仪法测定汞的含量。测定结果的相对标准偏差为0.28%~1.57%(n=6),方法检出限为1.0pg/kg,加标回收率为95.7%~117.4%。用该法对4种土壤标准样品进行了测定,测定结果与标准值相符。该方法适合于金精矿粉中微量汞的测定。  相似文献   

17.
A sequential injection (SI) method for the determination of mercury via cold vapor atomic absorption spectrophotometry is presented. The method differs from flow injection (FI) cold vapor methods for the determination of mercury because of the simplicity of the system required for the method: one pump, one valve, a gas-liquid separator, and an atomic absorption spectrophotometer equipped with a quartz cell. Under optimal conditions, the method has the following figures of merit: a linear calibration range of 1.0 to 20 microg L(-1); a detection limit of 0.46 microg L(-1); and a precision of 0.90% RSD (8 microg L(-1)). The procedure allows for a sampling rate of one injection per 80 s (excluding sample pretreatment). Results from the determination of mercury in water and fish specimens are also presented. The figures of merit of the method are compared to two other SI methods for the determination of mercury.  相似文献   

18.
The determination of trace concentrations of Hg in water samples by the use of electrolytic cold vapor generation (ECVG) system and AFS was studied. Several buffer solutions were used and the detection limits with these systems were found to be by a factor of 1–2 lower than in the conventional electrolytic cold vapor generation system. Comparing with the traditional inorganic acid, phosphate buffer solution (PBS) increased the signal intensity of Hg vapor from electrolytic generation on Pt cathode and reduced the impact of cathode erosion on the stability of signal intensity. Moreover, buffer solution has better interference tolerance. The effects of the electrolytic conditions and interference ions on the ECVG have been studied. Under optimized conditions and with PBS as catholyte the detection limit for Hg was found to be 0.27 ng L−1. The relative standard deviation was 2.8% for 11 consecutive measurements of 1 μg L−1 Hg. This method has been applied in the determination of inorganic Hg in Yangtze River water.  相似文献   

19.
A simple and ultrasensitive method, which was based on cold vapor generation (CVG) coupled to atomic fluorescence spectrometry (AFS), was proposed for speciation analysis of inorganic mercury (Hg2+) and methylmercury (MeHg) in water samples. In the presence of UV irradiation, all the mercury (MeHg+Hg2+) in a sample solution can be reduced to Hg0 by SnCl2; without UV irradiation, only Hg2+ species can be determined. So the concentration of MeHg can be obtained from the difference of the total mercury and Hg2+ concentration; thus, speciation analysis of Hg2+ and MeHg was simply achieved without chromatographic separation. Under the optimized experimental conditions, the limits of detection were 0.01 ng mL-1 for both Hg2+ and MeHg. The sensitivity and limit of detection were not dependent on the mercury species, and a simple Hg2+ aqueous standard series can be used for the determination of both Hg2+ and MeHg.  相似文献   

20.
A photometric method for the determination of nanogram amounts of mercury based on formation of the red complex with thio-Michler's ketone in 30% aqueous propanol is described. The pH is adjusted to 5.8 with acetate buffer. When measured at 56Onm, the molar absorption coefficient is 1.51 × 105 1·mole?1·cm?1, corresponding to a Sandell index for Hg of 0.0013 μg/cm2. The Lambert-Beer law is obeyed for Hg from 0.007 to 1.5 μg/ml. With 5-cm cells, the limit of detection is 4.2 ng/ml, and the limit of determination 7.1 ng/ml. A statistical analysis of the performance is presented, along with the results of a study of interferences.  相似文献   