首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 756 毫秒
1.
The concept of interfacing a large-size column for capillary electrophoresis (CE) to electrospray ionization mass spectrometry (ESI-MS) for robust and automatic CE-MS operation is reported. Both standard ionspray interface and microionspray interface have been modified to operate in a sheath flow pattern to overcome the common stability problem in CE-MS coupling. To make the interface sensitive, a step-down stainless steel tube with smaller inner diameter and tapered tip was incorporated onto a larger tube embracing the CE column via cold soldering. The devices were evaluated for quantitative analysis of nucleotides at femtomole level and stable analytical performance in peptide profiling.  相似文献   

2.
The performance of a prototype porous tip sprayer for sheathless capillary electrophoresis-mass spectrometry (CE-MS) of intact proteins was studied. Capillaries with a porous tip were inserted in a stainless steel needle filled with static conductive liquid and installed in a conventional electrospray ionization (ESI) source. Using a BGE of 100 mM acetic acid (pH 3.1) and a positively charged capillary coating, a highly reproducible and efficient separation of four model proteins (insulin, carbonic anhydrase II, ribonuclease A and lysozyme) was obtained. The protein mass spectra were of good quality allowing reliable mass determination of the proteins and some of their impurities. Sheath-liquid CE-MS using the same porous tip capillary and an isopropanol-water-acetic acid sheath liquid showed slightly lower to similar analyte responses. However, as noise levels increased with sheath-liquid CE-MS, detection limits were improved by a factor 6.5-20 with sheathless CE-MS. The analyte response in sheathless CE-MS could be enhanced using a nanoESI source and adding 5% isopropanol to the BGE, leading to improved detection limits by 50-fold to 140-fold as compared to sheath liquid interfacing using the same capillary - equivalent to sub-nM detection limits for three out of four proteins. Clearly, the sheathless porous tip sprayer provides high sensitivity CE-MS of intact proteins.  相似文献   

3.
A simple and cost-effective laboratory-made liquid junction interface was used for coupling of CE with MS. In this device the capillary column and the spray tip were positioned in the electrode vessel containing appropriate spray liquid. The electrospray potential was applied on the electrode inside the liquid junction. A stable electrospray was produced at nanoliter per minute flow rates generated in the emitter tip without using an external pump. This arrangement provided high durability of the spray tip and independent optimization of the CE separation (use of coated capillaries) and ESI conditions. CE-MS analysis of mixtures of drugs, peptides, tryptic digests of proteins and biological fluids was optimized with respect to the effects of the distance between the separation capillary and electrospray tip and pressure applied on the liquid junction. The sensitivity of the system, in terms of the LOD (base peak monitoring) was below 10 ng/mL for the beta-blocker drugs and below 200 ng/mL for peptide analysis.  相似文献   

4.
Concentration sensitivity is a key performance indicator for analytical techniques including for capillary electrophoresis-mass spectrometry (CE–MS) with electrospray ionization (ESI). In this study, a flow-through microvial interface was used to couple CE with MS and improve the ESI stability and detection sensitivity. By infusing a peptide mixture through the interface into an MS detector at a typical flow rate for CE-MS analysis, the spatial region near the interface was mapped for MS signal intensity. When the sprayer tip was within a 6 × 6.5 × 5 mm region in front of the MS inlet, the ESI was stable with no significant loss of signal intensity for ions with m/z 239. Finite element simulations showed that the average electric field strength at the emitter tip did not change significantly with minor changes in emitter tip location. Experiments were conducted with four different mass spectrometer platforms coupled to CE via the flow-through microvial interface. Key performance indicators, that is, limit of detection (LOD) and linearity of calibration curves were measured for nine amino acids and five peptides. Inter- and intraday reproducibility were also tested. The results were shown to be suitable for quantification when internal standards were used.  相似文献   

5.
张含智  李凤  康经武 《色谱》2023,41(2):160-167
毛细管电泳-质谱联用技术具有分离效率高、检测灵敏度高、样品消耗量少,可同时提供样品的结构信息等优点,成为复杂样品分离分析的强有力工具。但是,毛细管电泳与质谱联用的接口技术依然未能很好的解决。为了拓展我们发展的金箔包裹的毛细管电泳分离柱尖端直接作为喷雾电极和无鞘流质谱接口的应用,本文报道了用无鞘流接口毛细管电泳-电喷雾质谱联用(CE-ESI-MS)分析5种酪氨酸激酶抑制剂(舒尼替尼、甲磺酸伊马替尼、吉非替尼、达沙替尼、埃罗替尼)的研究结果。这种接口集分离与电喷雾离子化于一根毛细管中,制作简单,成本低廉,且可批量制作。实验发现采用非水毛细管电泳分离模式不仅可以对5种酪氨酸激酶抑制剂实现基线分离,而且可以获得稳定的质谱信号。考察了电解质溶液组成对分离效果的影响,得到优化的背景电解质组成,即含2%(v/v)乙酸及5 mmol/L乙酸铵的乙腈-甲醇(80∶20, v/v)混合溶剂。在优化的条件下,5种激酶抑制剂可以得到基线分离,无鞘接口也可以长时间保持稳定的电喷雾,分析物的保留时间日内、日间重复性(RSD值)分别小于0.5%和0.8%,接口批次间的RSD值小于2.6%。与水相分离条件下的CE-MS对比,非水相条件下的5种酪氨酸激酶抑制剂的分离柱效更高,检测灵敏度更高,绝对检出限达到amol级。此外,采用无鞘流CE-MS分析了各类有机酸(千层纸素A、丹酚酸C和迷迭香酸)和脂溶性的大环内酯类抗生素(阿奇霉素、红霉素和环孢素A),均可以获得良好的分离效果和质谱检测结果。  相似文献   

6.
A sheath-flow capillary electrophoresis-mass spectrometry (CE-MS) system utilizing a fully integrated large-bore stainless-steel emitter electrode tapered at the end for micro-ionspray operation has been developed and evaluated. A separation capillary with an outer diameter of up to 360 microm was inserted into the electrode thus forming a void volume of less than 15 nL between the capillary end and the electrospray ionisation (ESI) tip. The sheath liquid, usually methanol-water (80:20) with 0.1% formic acid for positive ion mode or methanol for negative ion mode, was delivered at 0.5-1.0 microL/min. Unlike previously reported CE-MS interfaces, the CE-MS probe was incorporated directly onto an Applied Biosystems/MDS SCIEX orthogonal-spray Turbo "V" ion source for ease of use and automatic operation. This integration enables fast and facile coupling and replacement of the separation capillary without interrupting the ion source configuration, and the sheath liquid supply. The reusable electrospray electrode was precisely fabricated and aligned with the length of the nebulizing gas tube for improved reproducibility. Automation was achieved through software control of both CE and tandem MS (MS/MS) for unattended batch sample analysis. The system was evaluated for attomole- to low femtomole-level profiling of model peptides and protein mixtures, bisphosphates, as well as antiviral nucleosidic drugs in cellular extracts.  相似文献   

7.
The application of capillary electrophoresis-mass spectrometry (CE-MS) to the analysis of compounds of concern to the aquaculture industry is reported. Two different approaches to coupling the CE column to an IonSpray atmospheric pressure ionization (API) interface, viz., a liquid-junction and a coaxial arrangement, are describe and compared with regard to ruggedness, ease of use, sensitivity and electrophoretic performance. The different injection modes used in three commercial capillary electrophoresis systems were also evaluated for their applicability to CE-MS. The use of CE-MS for the analysis of a variety of classes of antibiotics used in the fish aquaculture industry, such as the sulfonamides and their potentiators (e.g., trimethoprim), is demonstrated and was used to confirm the presence of these components in shellfish extracts at the low ppm level. CE-MS was also applied to the analysis of marine toxins such as saxitoxin and its analogues which are associated with paralytic shellfish poisoning, and also the toxins responsible for amnesic and diarrheic shellfish poisoning. Tandem mass spectrometry (MS-MS) was used to provide structural information on these analytes, and the ability to distinguish isomeric compounds based on their different migration and fragmentation characteristics using CE-MS-MS is demonstrated.  相似文献   

8.
Tseng MC  Chen YR  Her GR 《Electrophoresis》2004,25(13):2084-2089
A simple and durable sheath liquid interface for capillary zone electrophoresis-electrospray ionization-mass spectrometry (CZE-ESI-MS) has been developed. This interface utilized a beveled tip emitter and was found to be more sensitive than the conventional sheath liquid interface. The use of a beveled tip reduces the optimal flow rate and therefore decreases sample dilution. The interface utilized a 380 microm inner diameter and 400 microm outer diameter beveled tapered tip. Because of the large inner diameter and outer diameter of the tip, the interface is robust and can be easily implemented. The performance of this interface for CZE-ESI-MS and micelle electrokinetic capillary electrophoresis-electrospray-mass spectrometry, as demonstrated by the analysis of synthetic drugs and triazine mixtures, was significantly better than results obtained using a conventional sheath liquid interface.  相似文献   

9.
Methods for the determination of drug residues in water have been developed based on the combination of liquid chromatography (LC) or capillary electrophoresis (CE) with mass spectrometry (MS). For HPLC-MS two types of interfaces (pneumatically assisted electrospray ionization interface or an atmospheric pressure chemical ionization interface, respectively) were employed and compared in terms of detection limits. 2 mM Ammonium acetate at pH 5.5 and a methanol gradient was used for the HPLC-MS allowing the separation of a number of drugs such as paracetamol, clofibric acid, penicillin V, naproxen, bezafibrate, carbamazepine, diclofenac, ibuprofen and mefenamic acid. A 20 mM ammonium acetate solution, pH 5.1 was employed for the separation of clofibric acid, naproxen, bezafibrate, diclofenac, ibuprofen and mefenamic acid by CE-MS. Sample pretreatment was performed by solid-phase extraction (SPE) for HPLC-MS or by a combination of liquid-liquid extraction and SPE for CE-MS. The applicability of both the HPLC-MS and CE-MS method was demonstrated for several river water samples.  相似文献   

10.
Capillary electrophoresis (CE) was coupled to negative mode electrospray ionisation-mass spectrometry (MS) for separation and detection of phosphorylated and acidic metabolites in extracts of prokaryotes. Unlike previous CE-MS systems for metabolite analysis, a sheathless interface was used to improve sensitivity. To accomplish this, the separation capillary was modified by creating a porous junction near the outlet where the electrospray voltage and cathodic voltage for CE were applied. The outlet of the capillary was pulled to a 5 microm inner diameter to form an electrospray emitter and had a frit fabricated near the exit to prevent clogging. During analysis pressure was applied at the inlet of the separation column to create sufficient flow towards the detector. Limits of detection for 19 metabolites in full scan mode ranged from 20 nM for ADP ribose to 2.5 microM for alpha-ketoglutarate for 40 nL injections. Extracts of Escherichia coli, strain DH5-alpha, were analyzed using this system. In full scan mode, 118 different metabolites were detected. Tandem mass spectrometry was also employed to attempt identification. Reproducible fragmentation of 19 parent peaks was found and 10 of these produced spectra that were consistent with identification obtained from matching to compounds in the MetaCyc database. These results demonstrate the utility of a sensitive CE-MS system for large scale metabolite detection in biological samples.  相似文献   

11.
Zhao SS  Zhong X  Chen DD 《Electrophoresis》2012,33(8):1322-1330
An atmospheric ion lens incorporated into an electrospray ion source for capillary electrophoresis-mass spectrometry (CE-MS) is found to extend the stable operational regions for both flow rates and electrospray ionization (ESI) voltages. The stable operating conditions for the ESI source with and without the ion lens were characterized. The results showed that the stable operation region was widest when the voltage difference between the sprayer and the ion lens ranges from 2.6 to 2.8 kV, and under these condition, the CE-MS interface can be adapted to a broader range of electroosmotic and modifier flow rates. Modeling of the electric field in the electrospray ion source with the ion lens suggests that the extension of the stable region is attributed to the flatter equipotential surfaces around the sprayer tip and higher electric field strengths in the rest of the interface region.  相似文献   

12.
Monolithic columns having long hydrocarbon chains were prepared by in-situ polymerization in capillary fused silica tubing. The capillary columns were coupled with a newly developed carbon fiber electrospray ionization (ESI) emitter for proteomic analysis using sheathless capillary HPLC-ESI mass spectrometry (MS). The sample loading capacity and chromatographic performance of the styrene-based monolithic column, which was prepared by photo-polymerization of octylstyrene (OS) and divinylbenzene (DVB) were compared with that of the methacrylate-based monolithic column composed of lauryl methacrylate (LMA) and ethylene dimethacrylate (EDMA). The sample loading ability of tryptic digested protein in poly-OS (POS)-DVB column was higher than that of poly-LMA (PLMA)-EDMA column, possibly due to the irregular and rugluous surface offering a greater surface area of POS-DVB stationary phase. The POS-DVB column also provided better separation efficiency in the separation of high concentration (10 microg) of tryptic digested albumin bovine serum (BSA). Due to the successful interface of a highly efficient monolithic column and a stable, durable carbon fiber emitter, low femtomole levels of peptides were successfully separated and identified in the presence of large amounts of tryptic digested protein.  相似文献   

13.
CE hyphenated to ESI-MS (CE-ESI-MS) is a well-established technique to analyze charged analytes in complex samples. Although various interfaces for CE-MS coupling are commercially available, the development of alternatives which combine sensitivity, simplicity, and robustness remains a topic of research. In this work, a nanoflow sheath liquid CE-MS interface with two movable capillaries inside a glass emitter is described. The setup enables a separation mode and a conditioning mode to guide the separation capillary effluent either into the electrospray or to the waste, respectively. This enables to exclude parts of the analysis from MS detection and unwanted matrix components reaching the mass spectrometer, comparable to divert valves in LC-MS coupling. Also, this function improves the overall robustness of the system by reduction of particles blocking the emitter. Preconditioning with electrospray interfering substances and even the application of coating materials for every analysis is enabled, even while the separation capillary is built into the interface with running electrospray. The functionality is demonstrated by analyses of heavy matrix bioreactor samples. Overall, this innovation offers a more convenient installation of the interface, improved handling with an extended lifetime of the emitter tips and additional functions compared to previous approaches, while keeping the higher sensitivity of nanoflow CE-MS-coupling.  相似文献   

14.
Electrospray ionization (ESI) is the most widely used ionization method in on-line coupling of capillary electrophoresis-mass spectrometry (CE-MS). The conventional coaxial sheath flow electrospray interface is currently being replaced by the more sensitive nanoelectrospray technique. The usual limitation of nanoelectrospray CE-MS interface has been its short lifetime caused by deterioration of the metal coating on the CE capillary terminus. This article describes an easy way to construct a more durable and sensitive nanospray interface for nonaqueous CE-MS. In this approach a very thin glass spray capillary (ca. 30 microm outer diameter) is partly inserted inside the CE capillary, the junction being surrounded by the electrolyte medium, which is in contact with the platinum electrode. The interface was tested with five pharmaceuticals: methadone, pentazocine, levorphanol, dihydrocodeine, and morphine. Detection limits ranged from 12 to 540 fmol. Separation efficiency and reproducibility were also studied. The CE current was found to be stable and the migration times were highly reproducible. All the CE separations were carried out in a nonaqueous background electrolyte solution.  相似文献   

15.
A sample enrichment technique to increase sensitivity in capillary electrophoresis–mass spectrometry (CE-MS) is described. Peptides or glycopeptides are retained and concentrated on a short (3–5-mm) reversed-phase (C18) packed-bed situated in the fused-silica separation capillary and are subsequently released for electrophoretic separation by injection of an organic elutant. The concentration limits of detection are in the high picomolar range with a sheath-flow CE-MS interface.  相似文献   

16.
On-line capillary electrophoresis (CE) separations are shown for a synthetic peptide mixture and a tryptic digest of human hemoglobin in an uncoated fused-silica capillary with detection using atmospheric pressure ionization mass spectrometry (API-MS). The CE system utilized a 1-m capillary column of either 75- or 100-microns I.D. These somewhat larger inside diameters allow higher sample capacities for MS detection and the 1-m length facilitates connecting the CE column to the liquid junction-ion spray interface and MS system. Low volatile buffer concentrations (15-20 mM) of ammonium acetate or ammonium formate, and high organic modifier content (5-50%) of methanol or acetonitrile facilitates ionization under electrospray conditions. This study shows that peptides separated by CE may be transferred to the API-MS system through a liquid junction coupling to the pneumatically assisted electrospray (ion spray) interface at low buffer pH when the electroosmotic flow is low (0-0.04 microliter/min). CE-MS as described herein is facilitated by features in modern CE instrumentation including robotic cleaning and pressurization of the capillary inlet. The latter is particularly useful for repetitive rinsing and conditioning of the capillary column between analyses in addition to continuous 'infusion' of sample to the mass spectrometer for tuning purposes. In addition to facile molecular weight determination, amino acid sequence information for peptides may be obtained by utilizing on-line tandem MS. After the tryptic digest sample components enter the API-MS system, the molecular ion species of individual peptides may be focussed and transmitted into the collision cell of the tandem triple quadrupole mass spectrometer. Collision-induced dissociation of protonated peptide molecules yielded structural information for their characterization following injection of 10 pmol of a tryptic digest from human hemoglobin.  相似文献   

17.
Shamsi SA 《Electrophoresis》2002,23(22-23):4036-4051
A review is presented to highlight several approaches for coupling capillary electrophoresis (CE) and electrospray ionization-mass spectrometry (ESI-MS) for analysis of chiral compounds. A short discussion of commercially available CE-MS instruments and interface design is followed by a detail review on various modes of chiral CE-MS. In general, for each CE-MS mode, the capabilities, applications and limitations for chiral analysis have been pointed out. The first mode, chiral capillary zone electrophoresis-mass spectrometry (CZE-MS) in which neutral derivatized cyclodextrins (CDs) are used is possible using either column coupling with voltage switching or a partial-filling technique (PFT). However, some applications of direct coupling of CZE-MS mode are also reported. The second mode is a chiral electrokinetic chromatography-mass spectrometry (EKC-MS) in which a charged chiral selector such as a sulfated beta-CD or a vancomycin could be conveniently employed. This is because these chiral selectors have a significantly higher countercurrent electrophoretic mobility which prevents the entrance of these selectors into the mass spectrometer. The combination of counter-migration and PFT demonstrates that this synergism could be successfully applied to chiral analysis of a broader range of compounds. It is well-known that the on-line coupling of micellar electrokinetic chromatography to mass spectrometry (MEKC-MS) is problematic because the high surface activity and nonvolatile nature of conventional surfactant molecules lower the electrospray ionization efficiency. However, a recent report demonstrates that this hyphenation is now possible with the use of molecular micelles. Various MEKC-ESI-MS parameters that can be used to optimize both chiral resolution and ESI response are discussed. Finally, two recent examples that demonstrate the feasibility of using either open-tubular or packed chiral CEC with MS are reviewed. This survey will attempt to cover the state-of-the-art on various modes of CE-MS from 1998 up to 2002.  相似文献   

18.
We have developed a novel sheath-flow interface for low-flow electrospray ionization mass spectrometry (ESI-MS) and capillary electrophoresis/electrospray mass spectrometry (CE/ESI-MS). The interface is composed of two capillaries. One is a tapered fused-silica ESI emitter suitable for microliter and nanoliter flow rate electrospray and the other is a tail-end gold-coated CE separation column that is inserted into the emitter. A sheath liquid is supplied between the column and the emitter capillaries. The gold coating and the sheath liquid are used as the conducting media for ESI and the CE circuit. This novel design was initially evaluated by an infusion ESI-MS analysis of the most common antiretroviral dideoxynucleosides, followed by CE/MS coupling analysis of several antidepressant drugs. With infusion studies, the effects of the sheath liquid and the sample flow rates on detection sensitivity and signal stability were investigated. For an emitter with an internal diameter of 30 microm, the optimum flow rates for the sheath and the sample were 200 and 300 nL/min, respectively. The main improvement of this approach in comparison with conventional sheath liquid approaches using an ionspray interface is the gain in sensitivity. Sensitivities were three times better for dideoxynucleosides analyzed by infusion and 12 times higher for antidepressant drugs analyzed by CE/MS with this interface compared with ionspray. The emitter is durable, disposable, and simple to fabricate.  相似文献   

19.
The dimensions of the capillaries used to construct a typical coaxial capillary electrophoresis-mass spectrometry (CE-MS) interface, i.e. the inner diameter, the outer diameter and the wall thickness, have been shown to affect the performance of the CE-MS system. The influence of these parameters has been investigated in both MS and MS-MS modes. The initial results indicate that by reducing all the sheath capillaries' dimensions and the CE capillary outer diameter, better operation and increased sensitivity can be achieved. The capillary arrangement which gives optimum sensitivity and stable operation has been suggested.  相似文献   

20.
Online coupling of capillary electrophoresis (CE) to electrospray ionization mass spectrometry (MS) has shown considerable potential, however, technical challenges have limited its use. In this study, we have developed a simple and sensitive sheathless CE-MS interface based on the novel concept of forming a sub-micrometer fracture directly in the capillary. The simple interface design allowed the generation of a stable ESI spray capable of ionization at low nanoliter flow-rates (45–90 nL/min) for high sensitivity MS analysis of challenging samples like those containing proteins and peptides. By analysis of a model peptide (leucine enkephalin), a limit of detection (LOD) of 0.045 pmol/μL (corresponding to 67 attomol in a sample volume of ∼15 nL) was obtained. The merit of the CE-MS approach was demonstrated by analysis of bovine serum albumin (BSA) tryptic peptides. A well-resolved separation profile was achieved and comparable sequence coverage was obtained by the CE-MS method (73%) compared to a representative UPLC-MS method (77%). The CE-MS interface was subsequently used to analyse a more complex sample of pharmaceutically relevant human proteins including insulin, tissue factor and α-synuclein. Efficient separation and protein ESI mass spectra of adequate quality could be achieved using only a small amount of sample (30 fmol). In addition, analysis of ubiquitin samples under both native and denatured conditions, indicate that the CE-MS setup can facilitate native MS applications to probe the conformational properties of proteins. Thus, the described CE-MS setup should be useful for a wide range of high-sensitivity applications in protein research.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号