首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 656 毫秒
1.
Trace determination (low ng/ml) of linear alkylbenzensulfonates (LASs) in water was achieved by solid-phase microextraction (SPME) of ion-pairs formed with tetrabutylammonium. This ion-pairing reagent served two purposes. First, it allowed the extraction of LAS with the polydimethylsiloxane fiber by counterion association and second, the derivatization of the formed LAS ion pairs in the GC injection port at 300 degrees C to form the corresponding sulfonated butyl esters. The methodology developed allows the isomer specific determination of LAS at low detection limits (0.16-0.8 ng/ml), depending on the alkyl chain lengths of LASs with RSDs of 10-12%. Furthermore, the developed methodology was applied to urban wastewater and sea water and compared with a solid-phase extraction (SPE) method (e.g. C18 and strong anion-exchange sorbent) to obtain concordant values for urban wastewater. Moreover, the developed SPME methodology overcame the procedural blank and matrix-dependent recoveries found in the SPE methodologies at low LAS concentrations.  相似文献   

2.
In the present work, a method was developed and optimized aiming at the determination of anatoxin-a in environmental water samples. The method is based on the direct derivatization of the analyte by adding hexylchloroformate in the alkalinized sample (pH = 9.0). The derivatized anatoxin-a was extracted by a solid-phase microextraction (SPME) procedure, submersing a PDMS fiber in an amber vial for 20 min under magnetic stirring. GC-MS was used to identify and quantify the analyte in the SIM mode. Norcocaine was used as internal standard. The following ions were chosen for SIM analyses (quantification ions in italics): anatoxin-a: 191, 164, 293 and norcocaine: 195, 136, 168. The calibration curve showed linearity in the range of 2.5-200 ng/mL and the LOD was 2 ng/mL. This method of SPME and GC-MS analysis can be readily utilized to monitor anatoxin-a for water quality control.  相似文献   

3.
Triacontyl bonded silica (C(30)) material was applied as solid-phase extraction (SPE) sorbent and an SPE-LC-MS method was established for the determination of eight estrogens and their metabolites in water samples. Compared to commercial C(18) SPE cartridge, the performance of C(30) was evaluated in various important SPE conditions, such as sorbent mass, elution solvent and its volume, loading flow rate, and sample loading volume. The results showed a superior performance of C(30)-C(18) by the shorter treatment time and fewer required elution solvent. In the optimum conditions, the results showed good recoveries (80.5-109.4%), excellent linear relationships (0.02-1 ng/mL, except 2-MeO-E(2)), high precisions (lower than 10.0% RSD for both low and high spiked concentration), and low LODs (1-16 ng/L). Method validation using C(30) packed cartridge was also testified with spiked real water samples, including tap water and river water. Satisfy results demonstrated the feasibility of C(30) SPE to the analysis for real environmental waters.  相似文献   

4.
A new technique for preparation of an unbreakable solid-phase microextraction (SPME) fiber, using sol-gel technology is developed. Primarily, an ultrathin two-dimensional intermediate film was prepared by hydrolysis of 3-(trimethoxysilyl)-1-propanthiol self-assembled monolayer grafted onto gold, then a stationary phase by electrodeposition of 3-(trimethoxysilyl)propylmethacrylate as a precursor, tetramethyl orthosilicate and polyethylene glycol as a coating polymer was produced. The scanning electron microscopy images revealed that the new fiber exhibits a rather porous and homogenous surface. The thermal stability of the fabricated fiber was investigated by thermogravimetric analysis. The applicability of the prepared fiber coating in conjunction with gas chromatography-mass spectrometry was examined by SPME of polycyclic aromatic hydrocarbons, as model analytes, from aquatic media. An extraction time of 20 min at 50 °C gave maximum peak areas when NaCl, 15% was added to the aqueous samples. Limits of detection were in the range of 0.01-0.02 ng/mL and relative standard deviation values were in the range of 4-16% at 1 ng/mL. The developed method was successfully applied for the analysis of real water samples while the relative recovery percentage was in the range of 102-118%.  相似文献   

5.
This paper deals with comparison of efficiency of extraction techniques (solid-phase extraction, SPE and solid-phase microextraction, SPME) used for extraction of nitrate esters (ethyleneglycoldinitrate, EGDN and nitroglycerin, NG), representing the first step of the method of quantitative determination of trace concentrations of nitrate esters in water samples. EGDN and NG are subsequently determined by means of high-performance liquid chromatography with ultraviolet detection (HPLC-UV). Optimization of SPE and SPME conditions was carried out using model water samples. Seven SPE cartridges were tested and the conditions were optimized (type of sorbent, type and volume of solvent to be used as eluent). For both nitrate esters the limit of detection (LOD) and the limit of quantification (LOQ) obtained using SPE/HPLC-UV were 0.23 microg mL(-1) and 0.70 microg mL(-1), respectively. Optimization of SPME conditions: type of SPME fibre (four fibres were tested), type and time of sorption/desorption, temperature of sorption. PDMS/DVB (polydimethylsiloxane/divinylbenzene) fibre coating proved to be suitable for extraction of EGDN and NG. For this fibre the LOD and the LOQ for both nitrate esters were 0.16 microg mL(-1) and 0.50 microg mL(-1), respectively. Optimized methods SPE/HPLC-UV and SPME/HPLC-UV were then used for quantitative determination of nitrate esters content in real water samples from the production of EGDN and NG.  相似文献   

6.
Zhang LH  Zhang CJ  Chen X  Feng YQ  Wu XZ 《Electrophoresis》2006,27(16):3224-3232
A novel CE method combined with SPE in a single capillary was developed for analysis of chlorophenols in water. A frit of 0.5 mm was first made by a sol-gel method, followed by packing a SPE sorbent in the inlet end of the capillary. Two phenol derivatives, 2,4-dichlorophenol and 2,4,5-trichlorophenol, were used as the model compounds. By loading sample solutions into the capillary, the two chlorophenols were extracted into the sorbent. They were desorbed by injecting only about 4 nL of methanol. Finally, the analytes were separated by conventional CE. The technique provided a concentration enhancement factor of over 4000-fold for both chlorophenols. The detection limits (S/N = 3) of 2,4-dichlorophenol and 2,4,5-trichlorophenol were determined to be 0.1 ng/mL and 0.07 ng/mL, respectively. For replicate analyses of 5 ng/mL of 2,4-dichlorophenol, within-day and between-day RSDs of migration time, peak height and peak area were in the range of 1.8-2.0%, 4.0-4.4% and 4.1-4.6%, respectively. The method shows wide linear range, acceptable reproducibility and excellent sensitivity, and it was applied to the analyses of spiked river water samples. The capillary packed with the SPE sorbents can be used for more than 400 runs without performance deterioration.  相似文献   

7.
In this study, an extraction and preconcentration technique using solid-phase extraction (SPE) along with hollow fiber (HF) has been developed as an ultra-preconcentration technique for some triazole pesticides in aqueous samples. Triazole pesticides were employed as model compounds to assess the method and were monitored by gas chromatography-flame ionization detection (GC-FID). Initially, an aqueous solution of target analytes was passed through an RP-8 SPE cartridge and then the adsorbed analytes were eluted with μL amounts of toluene. The collected elute was slowly introduced into an HF that had one end blocked. This allowed precipitation inside the lumen and pores of the HF. Finally, the obtained HF was mounted on a home-made solid-phase microextraction syringe and entered into the GC injection port for thermal desorption-GC analysis. The effect of various experimental parameters including injection port temperature, desorption time, state of HF, washing solvent, elution solvent and its volume, sample volume, etc. were investigated for finding the optimum conditions. The calibration graphs were linear in the ranges of 2-1000 ng/mL (penconazole and hexaconazole), 5-1000 ng/mL (tebuconazole), 15-1000 ng/mL (triticonazole) and the detection limits (LODs) ranged from 0.6 to 4.5 ng/mL. The enhancement factors were in the range of 870-950. The relative standard deviations (RSD%) for five repeated experiments (C=250 ng/mL of each pesticide) varied from 4.5 to 8.7%. The relative recoveries obtained for analytes in grape juice samples, spiked with different levels of each pesticide, were in the range of 87-119%.  相似文献   

8.
Graphene is a novel and interesting carbon material that could be used for the separation and purification of some chemical compounds. In this investigation, graphene was used as a novel fiber‐coating material for the solid‐phase microextraction (SPME) of four triazine herbicides (atrazine, prometon, ametryn and prometryn) in water samples. The main parameters that affect the extraction and desorption efficiencies, such as the extraction time, stirring rate, salt addition, desorption solvent and desorption time, were investigated and optimized. The optimized SPME by graphene‐coated fiber coupled with high‐performance liquid chromatography‐diode array detection (HPLC‐DAD) was successfully applied for the determination of the four triazine herbicides in water samples. The linearity of the method was in the range from 0.5 to 200 ng/mL, with the correlation coefficients (r) ranging from 0.9989 to 0.9998. The limits of detection of the method were 0.05‐0.2 ng/mL. The relative standard deviations varied from 3.5 to 4.9% (n=5). The recoveries of the triazine herbicides from water samples at spiking levels of 20.0 and 50.0 ng/mL were in the range between 86.0 and 94.6%. Compared with two commercial fibers (CW/TPR, 50 μm; PDMS/DVB, 60 μm), the graphene‐coated fiber showed higher extraction efficiency.  相似文献   

9.
结合固相萃取(SPE)盘与含支撑物的SPE柱技术,制备了一种新型的无筛板型固相萃取柱.以C18填料为例,以话梅样品为介质对其中的苯甲酸进行分析,并用传统固相萃取小柱平行比较;将SPE与HPLC-UV结合,考察了填料对简单介质中苯甲酸的最大吸附量及洗脱曲线,研究了新型SPE柱在实际应用中的分离纯化效果.结果表明,新型SPE柱对样品的吸附效果更好,规格为200 mg/3 mL的SPE柱对苯甲酸的吸附量达到0.951 mg,超过了传统柱的吸附量0.908 mg;其洗脱曲线与传统柱几乎重合;苯甲酸在1~100 mg/L浓度范围内线性关系良好, r=0.9999,用此SPE柱纯化后的样品加标回收率和相对误差分别在88.4%~102.3%和1.4%~2.9%之间.  相似文献   

10.
Bamboo carbon, an inexpensive, readily available material, has attracted great attention in recent years because of adsorptive properties. In this paper, the potential of bamboo carbon as a SPE adsorbent for the determination of phenols, was investigated. Phenols are important environmental contaminants that may adversely affect human health. Parameters influencing extraction efficiency, including type of eluent, eluent volume, amount of adsorbent, as well as sample pH, volume, and flow rate were investigated and optimized. The optimized results exhibited excellent linear relationships between peak area and phenol concentrations over the range of 2.0–100 ng/mL, with precision between 2.2–7.2%. The LODs were 0.06–0.4 ng/mL for the eight phenols tested. The proposed method has been successfully applied to the analysis of several real‐world environmental water samples. These results indicate that bamboo carbon may be used as a novel SPE adsorbent for the concentration and determination of phenols in real environmental water samples.  相似文献   

11.
A highly porous fiber-coated SBA-15/polyaniline material was prepared for solid-phase microextraction (SPME). The SBA-15/polyaniline nanocomposite was synthesized via chemical polymerization. The prepared SBA-15/polyaniline particles were analyzed by scanning electron microscopy analysis. The prepared nanomaterial was immobilized onto a stainless steel wire for fabrication of the SPME fiber. The fiber was evaluated for the extraction of some polycyclic aromatic hydrocarbons (PAHs) from aqueous sample solutions in combination with gas chromatography-mass spectrometry (GC-MS). In optimum conditions (extraction temperature 60°C, extraction time 40 min, ionic strength 20%, stirring rate: 500 rpm, desorption temperature 260°C, desorption time 2 min), the repeatability for one fiber (n=3), expressed as relative standard deviation (RSD%), was between 5.3 and 8.6% for the test compounds. For deionized water, spiked with selected PAHs, the detection limits for the studied compounds were between 2 and 20 pg/mL.  相似文献   

12.
A headspace solid-phase microextraction method (HS-SPME) followed by gas chromatography with mass spectrometric detection (GC/MS) has been developed for the determination of low concentrations of nicotine in hair. Parameters affecting the SPME procedure including type of fiber coating, extraction mode, extraction temperature and time, desorption time, stirring, and salt addition have been evaluated and optimised. The method provided good linearity (r(2)≥0.9980) over the concentration range tested (0.2-20 ng/mg) and low detection limit (0.02 ng/mg). Precision expressed as relative standard deviation was <10%. The average accuracy was 95%. The proposed method was used to determine hair nicotine levels in 100 children in order to assess exposure to environmental tobacco smoke (ETS). The described HS-SPME procedure is fast, simple, sensitive, and solvent-free and is therefore suitable for studies involving ETS exposure assessment.  相似文献   

13.
A highly sensitive simultaneous quantitative method for a cassette cold-microdosing study on celiprolol and atenolol was developed with liquid chromatography-tandem mass spectrometry. The method utilizes a combination of solid-phase extraction (SPE) with strong cation exchange (SCX) cartridge columns and reversed-phase chromatography with an ODS analytical column. SCX-SPE cartridge columns (100 mg sorbent) were used for a selective extraction of celiprolol, atenolol and metoprolol (internal standard) from 500 μL of human plasma samples. Turbo-ion spray at positive mode was employed for the ionization of the drug compounds. Quantitation was performed on a triple quadrupole mass spectrometer by selected reaction monitoring with the transitions of m/z 380 to m/z 251 for celiprolol and m/z 267 to m/z 145 for atenolol. Separation of analytes was achieved on an ODS column (100 mm length × 2.1 mm id, 3 μm) by a gradient elution with 10 mM formic acid and methanol by varying their proportion at a flow rate of 0.2 mL/min. The method was validated in the range of 1-250 pg/mL for celiprolol and 2.5-250 pg/mL for atenolol and was successfully applied to the elucidation of pharmacokinetic profiling in a cold cassette microdosing study of the β-blockers.  相似文献   

14.
A novel method is firstly presented for field and rapid analysis of short-chain aliphatic amines in water as their pentafluorobenzaldehyde (PFBAY) derivative using solid-phase microextraction (SPME) and portable GC. In the proposed method, short-chain aliphatic amines in water rapidly reacted with PFBAY, and then were headspace extracted and concentrated by SPME. The formed amines derivatives were analyzed by portable GC. The SPME parameters of fiber selection, extraction temperature, extraction time, and stirring rate were studied. The method validations including LOD, recovery, precision, and linearity were studied. It was found that the proposed method required the whole analysis time 22 min, and provided low LOD of 1.2-4.6 ng/mL, good recovery of 91-106%, good precision of RSD value 3.5-9.3%, and linear range 20.0-500 ng/mL (r(2) >0.99). The obtained results demonstrated that the SPME-portable GC is a simple, rapid, and efficient method for the field analysis of short-chain aliphatic amines. Finally, the proposed method was further applied to the quantification of ethylamine, propylamine, and butylamine in environmental water.  相似文献   

15.
In this study a direct solid-phase microextraction (SPME) procedure has been developed for the determination of carbofuran in water. Experimental parameters such as selection of SPME coating, effect of temperature, effect of salt addition and solvent desorption were studied and optimized. Analytical parameters such as linearity, precision, detection and quantitation limits, and matrix effects for solid-phase extraction (SPE) and SPME methods were evaluated for comparison purposes with the aim of selecting the most appropriate depending on the detection capabilities required. SPE and SPME were followed by high-performance liquid chromatography with diode-array detection, using a 50 x 4.6 mm I.D. guard column and a 150 x 4.6 mm I.D. analytical column, both packed with C18 silica. Both methods can be applied to real samples and give the same results, but SPE allows the detection of lower carbofuran concentrations (0.06 microg/L) as compared to  相似文献   

16.
A highly porous fiber coated with polythiophene/hexagonally ordered silica nanocomposite was prepared for solid‐phase microextraction (SPME). The prepared nanomaterial was immobilized onto a stainless‐steel wire for the fabrication of the SPME fiber. Polythiophene/hexagonally ordered silica nanocomposite fibers were used for the extraction of some polycyclic aromatic hydrocarbons from water samples. The extracted analytes were transferred to the injection port of a gas chromatograph using a laboratory‐designed SPME device. The results obtained prove the ability of the polythiophene/hexagonally ordered silica material as a new fiber for the sampling of organic compounds from water samples. This behavior is due most probably to the increased surface area of the polythiophene/hexagonally ordered silica nanocomposite. A one‐at‐a‐time optimization strategy was applied for optimizing the important extraction parameters such as extraction temperature, extraction time, ionic strength, stirring rate, and desorption temperature and time. Under the optimum conditions, the LOD of the proposed method is 0.1–3 pg/mL for analysis of polycyclic aromatic hydrocarbons from aqueous samples, and the calibration graphs were linear in a concentration range of 0.001–20 ng/mL (R2 > 0.990) for most of the polycyclic aromatic hydrocarbons. The single fiber repeatability and fiber‐to‐fiber reproducibility were less than 8.6 and 19.1% (n = 5), respectively.  相似文献   

17.
以分散聚合法制备了二氧化硅/聚苯乙烯单分散复合微球,以红外光谱、透射电镜(TEM)、扫描电镜(SEM)等手段对其进行了表征。以合成的二氧化硅/聚苯乙烯作为固相萃取填料制作固相萃取小柱。通过固相萃取与液相色谱联用,测定了水中邻硝基酚、间硝基酚、对硝基酚和辛基酚、壬基酚,考察了固相萃取条件对固相萃取柱性能的影响,选择了最佳的色谱分离条件。结果表明,自制固相萃取小柱对水中硝基酚、烷基酚的萃取率高,与HPLC联用测定结果重现性好,邻硝基酚、间硝基酚、对硝基酚、辛基酚、壬基酚的最低检出限分别为0.90、0.72、0.62、0.38和0.41μg/L。  相似文献   

18.
An extraction agent featuring a natural product, baicalin, anchored on the surface of nanomagnetic particles (BMNPs) is herein reported. A facile solid-phase extraction (SPE) procedure with high selectivity toward flavonoids using BMNPs has been established. BMNPs were proven very effective for enriching flavonoids from extracts of medicinal plants such as Rosa chinensis. The SPE protocol involving a convenient solid-liquid separation by using an external magnet field was easy to carry out. Further, the SPE sorbent (BMNPs) could be reused for many times reducing the operation cost. Importantly, flavonoids retained on the BMNPs were effectively recovered by eluting with methanol. Coupling the proposed SPE with ESI-MS/MS allowed a quick quantification of flavonoids in herbal extracts. Simultaneous determination of eight flavonoids extracted from R. chinensis was demonstrated in this work.  相似文献   

19.
用溶胶-凝胶法制备PEG-20M固相微萃取探头   总被引:9,自引:0,他引:9  
采用溶胶-凝胶方法制备了PEG-20M涂层的固相微萃取(SPME)探头并研究了它的特性。该探头具有耐温高,抗溶剂冲洗,使用寿命长的特点。由于PEG-20M的极性比较强,因此它对极性化合物如酚等有很好的萃取能力。用该探头测定了酚类物质,检出限达0.78-4.2ng/mL,线性范围为0.1-10μg/mL,相对标准偏差RSD<6%。  相似文献   

20.
A sensitive and rapid derivatization method for the simultaneous determination of 1,3-dichloro-2-propanol (1,3-DCP) and 3-chloropropane-1,2-diol (3-MCPD) in water samples has been developed. The aim was to research the optimal conditions of the derivatization process for two selected reagents. A central composite design was used to determine the influence of derivatization time, derivatization temperature and reagent volume. A global desirability function was applied for multi-response optimization. The analysis was performed by gas chromatography-mass spectrometry. During the optimization of the extraction procedure, four different types of solid-phase extraction (SPE) columns were tested. It was demonstrated that the Oasis HLB cartridge produced the best recoveries of the target analytes. The pH value and the salinity were investigated using a Doehlert design. The best results for the SPE of both analytes were obtained with 1.5 g of NaCl and pH 6. The proposed method provides high sensitivity, good linearity (R(2)≥0.999) and repeatability (relative standard deviations % between 2.9 and 3.4%). Limits of detection and quantification were in the range of 1.4-11.2 ng/mL and 4.8-34.5 ng/mL, respectively. Recoveries obtained for water samples were ca. 100% for 1,3-DCP and 3-MCPD. The method has been successfully applied to the analysis of different samples including commercially bottled water, an influent and effluent sewage.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号