首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, the development and validation of an analytical method for the assay of 4,7-phenanthroline-5,6-dione I (dione I) using high-performance liquid chromatography (HPLC) and the determination of its synthetic impurities by employing the method in HPLC-mass spectrometry with atmospheric-pressure chemical ionization and photodiode-array UV detection is reported. The results show that dione I is eluted as a spectrally pure peak resolved from its impurities. 5-Bromo,4-7-phenanthroline is identified as the main impurity. This is supported by elemental analysis of the dione I, which demonstrated the presence of bromine. Validation parameters such as specificity and selectivity, linearity, accuracy, precision, limit of detection (LOD), limit of quantitation (LOQ), ruggedness, stability, and system suitability, which are evaluated for this method. The LOD and LOQ are 2.0 microg/mL and 50 microg/mL with a 0.50% relative standard deviation (%RSD), respectively. The calibration curves showed good linearity over the concentration range of 0.05-1.50 mg/mL. The correlation coefficient is > 0.9991 in each case. The %RSD values for intra- and interday precision studies are < 0.40%.  相似文献   

2.
A simple, sensitive and rapid HPLC method was developed and validated for the simultaneous determination of famotidine (FMT) and related impurities in pharmaceuticals. Chromatographic separation was accomplished within 10 min on a porous graphitic carbon (PGC) column using 50:50 v/v ACN-water containing 0.5% pentane sulphonic acid (PSA) as the mobile phase. Separation was achieved with a flow rate of 1 mL/min and a detection wavelength of 265 nm. The calibration curves were linear over a concentration range of 1.5-100 microg/mL. The intra- and interday RSDs (n = 5) for the retention times and peak area were all less than 2%. The method was sensitive with an LOD (S/N = 3) of 0.1 microg/mL for FMT, imp. C and 0.05 microg/mL for imp. 2, A and D. All recoveries were greater than 98%. The method was demonstrated to be precise, accurate and specific with no interference from the tablet ingredients and separation of the drug peak from the peaks of the degradation products (oxidative degradation and acid and base degradation). The results indicated that the proposed method could be used for the determination of FMT in commercial dosage forms and as a stability-indicating assay.  相似文献   

3.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay was developed and validated to quantify a novel marine-derived depsipeptide, Aplidin, in human plasma. The method was validated to demonstrate the specificity, recovery, limit of quantitation (LOQ), accuracy, and precision of measurements. The calibration range for Aplidin was established using Aplidin standards from 0.05-50 ng/mL in blank human plasma. The multiple reaction monitoring, based on the transition m/z 1110.7 --> 295.3, was specific for Aplidin, and that based on the transition m/z 1112.6 --> 297.3 was specific for didemnin B (the internal standard); no endogenous materials interfered with the analysis of Aplidin and didemnin B from blank human plasma. The assay was linear over the concentration range 0.05-50.0 ng/mL. The correlation coefficients for the calibration curves ranged from 0.9979 to 0.9999. The mean intra- and interday accuracies for all calibration standards (n = 12) ranged from 97 to 106% (相似文献   

4.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay was developed and validated to quantify a novel antineoplastic agent, PM02734, in dog plasma. The method was validated to demonstrate the specificity, limit of quantification (LOQ), accuracy, and precision of measurements. The calibration range for PM02734 was established using PM02734 standards from 0.05 to 100 ng/mL in blank plasma. The dominating ions were doubly charged molecular ions [M+2H]2+ at m/z 740.0 instead of singly charged ones at m/z 1478.4. The selected reaction monitoring (SRM), based on the m/z 740.0 --> 212.2 transition, was specific for PM02734, and that based on the m/z 743.8 --> 212.2 transition was specific for deuterated PM02734 (the internal standard, IS); no endogenous materials interfered with the analysis of PM02734 and IS from blank plasma. The assay was linear over the concentration range 0.05-100 ng/mL. In terms of sensitivity of assay 0.05 ng/mL is a very low LLOQ, especially considering PM02734 is a peptide. The correlation coefficients for the calibration curves ranged from 0.9990 to 0.9999. The mean intraday and interday accuracies for all calibration standards (n = 9) ranged from 93 to 111% (< or =11% bias) in dog plasma, and the mean interday precision for all calibration standards was less than 6.4%. The mean intra- and interday assay accuracy for all quality control replicates in dog plasma (n = 9), determined at each QC level throughout the validated runs, ranged from 85-111% (< or =15% bias) and from 99-109% (< or =9% bias), respectively. The mean intra- and interday assay precision was less than 12.1 and 13.3% for all QC levels, respectively. The assay has been used to support preclinical pharmacokinetic (PK) and toxicokinetic studies. The results showed that preclinical samples could be monitored for PM02734 up to 168 h after dosing, which allowed us to identify multiple elimination phases and accurately estimate PK information.  相似文献   

5.
Qiang Gao  Yu‐Qi Feng 《Electrophoresis》2011,32(16):2099-2106
Using magnetite/silica/poly(methacrylic acid‐co‐ethylene glycol dimethacrylate) (Fe3O4/SiO2/poly(MAA‐co‐EDMA)) magnetic microspheres, a rapid and high‐throughput magnetic solid‐phase extraction coupled with capillary zone electrophoresis (MSPE‐CZE) method was developed for the determination of illegal drugs (ketamine, amphetamines, opiates, and metabolites). The MSPE of target analytes could be completed within 2 min, and the eight target analytes could be baseline separated within 15 min by CZE with 30 mM phosphate buffer solution (PBS, pH 2.0) containing 15% v/v ACN as background electrolyte. Furthermore, hydrodynamic injection with field‐amplified sample stacking (FASS) was employed to enhance the sensitivity of this MSPE‐CZE method. Under such optimal conditions, the limits of detection for the eight target analytes ranged from 0.015 to 0.105 μg/mL. The application feasibility of MSPE‐CZE in illegal drugs monitoring was demonstrated by analyzing urine samples, and the recoveries of target drugs for the spiked sample ranging from 85.4 to 110.1%. The method reproducibility was tested by evaluating the intra‐ and interday precisions, and relative standard deviations of <10.3 and 12.4%, respectively, were obtained. To increase throughput of the analysis, a home‐made MSPE array that has potential application to the treatment of 96 samples simultaneously was used.  相似文献   

6.
A simple chiral high‐performance liquid chromatography (HPLC) method with ultraviolet (UV) detection was developed and validated for measuring Cloquintocet‐mexyl (ClM) enantiomers and clodinafop‐propargyl (CP) using cellulose tris‐(3,5‐dimethylphenylcarbamate) (CDMPC) as chiral stationary phase (CSP). The effects of mobile phase composition and column temperature on the ClM enantiomer separation were investigated. Good separation was achieved by using a mixture of n‐hexane and n‐propanol as mobile phase. Based on the chiral HPLC method, enantioselective quantitative determination analysis methods for this herbicide combined with CP in diluted plasma were developed and validated. The assay method was linear over a range of concentrations (0.5–100 µg/mL) in diluted plasma and the mean recovery was greater than 80% for both enantiomers and CP. The limits of quantification and detection for both ClM enantiomers and CP were 0.5 and 0.2 µg/mL, respectively. Intra‐ and interday relative standard deviations did not exceed 10% for three tested concentrations. The result suggested that the degradation of ClM enantiomers was stereoselective in rabbit plasma, and both rac‐ClM and CP degraded quickly in plasma, showing that the main existing forms with biological effect in animals are their metabolites. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

7.
《Electrophoresis》2018,39(7):1006-1013
In this study, a capillary zone electrophoresis (CZE) method was first developed to identify three microconstituents of isomeric pentacyclic triterpene acids (PTAs including oleanolic acid (OA), ursolic acid (UA) and betulinic acid (BA)) in Forsythiae Fructus (FF). The baseline separation of PTAs by CZE were eventually achieved in a background electrolyte (BGE) containing 50.0 mmol/L borax and 0.5 mmol/L β‐cyclodextrin (β‐CD) at pH 9.5 within 13.0 min. Herein, it was not only the compositions of BGE were detail investigated for rapid and good separation, but also the binding ratio and the equilibrium constants (K) for OA, UA and BA with β‐CD was estimated by double reciprocal equation to well understand the separation mechanism. The proposed method allowed the LODs of PTAs were averaged at 1.50 μg/mL with UV detection (at 200 nm). The interday RSD of migration time and peak area were around 2.0 and 4.7% (n = 5), respectively. Thus, the content of PTAs in 19 FF real samples distinguished from maturation stages and geographical areas in China was quantified with the proposed method. Depending on the amount of each PTA in FF, it was demonstrated these microconstituents might benefit to identify their harvested time even qualities.  相似文献   

8.
A simple and reliable HPLC method was developed for the simultaneous quantitative analysis of diethylene glycol (DEG) and propylene glycol (PG) in pharmaceutical products by precolumn derivatization. The derivatization reagent p-toluenesulfonyl isocyanate (TSIC, 10 microL, 20% in ACN v/v) was added to 100 microL of the sample, and then 10 muL of water was added. The resulting derivatives were separated using a C(18)analytical column and a mobile phase composed of 0.01 M KH(2)PO(4)buffer (adjusted to pH 2.5 with phosphoric acid) and ACN (47:53 v/v) at 1 mL/min and 25 degrees C. For detection, UV light at 227 nm was used. The derivatization conditions including reaction time, temperature, and concentration of TSIC were optimized. The calibration curves were linear from 0.062 to 18.6 microg/mL (r(2)= 0.9999) and from 0.071 to 21.3 microg/mL (r(2) = 0.9999) for DEG and PG, respectively. The RSD values of intra- and interday assays were all below 4% for DEG and PG. The proposed method was then successfully applied to analyze two Armillarisin A injection samples and two spiked syrup samples.  相似文献   

9.
A sensitive assay for the determination of chloroquine (Clq) and its pharmacologically active metabolite deethyl chloroquine in plasma by capillary electrophoresis (CE) is developed. Plasma levels of drug and metabolite are measured using HeCd laser-induced fluorescence (LIF) detection over a range of three orders of magnitude from 2 to 1000 ng/mL after liquid-liquid extraction. A limit of detection of 0.5 ng/mL is achieved. Validation of the method yields intra- and interday precision data within the limits of 10% (20% at limit of quantitation) and intra- and interday accuracy data greater than 6% throughout the whole working range. The method is applied for the drug monitoring of patients treated with Clq. Based upon this assay, two enantioselective CE-LIF methods for Clq and its main metabolite are developed. Mixtures of substituted gamma-cyclodextrins are used as chiral selectors. A baseline separation of the enantiomers of both analytes in one run is achieved in less than 11 min (method A) and less than 9 min (method B), respectively. Hydroxychloroquine is used as the internal standard for both methods.  相似文献   

10.
An assay for the simultaneous determination of the enantiomers of hydroxymebendazole (OH-MBZ) and hydroxyaminomebendazole (OH-AMBZ) together with aminomebendazole (AMBZ) in human plasma is described for the first time. It is based upon liquid-liquid extraction at alkaline pH from 0.5 mL plasma followed by analysis of the reconstituted extract by CE with reversed polarity in the presence of a 50 mM, pH 4.2 acetate buffer containing 15 mg/mL sulfated beta-CD as chiral selector. For all compounds, detection limits are between 0.01 and 0.04 microg/mL, and intraday and interday precisions evaluated from peak area ratios are <6.9 and <8.5%, respectively. Analysis of 39 samples of echinoccocosis patients undergoing pharmacotherapy with mebendazole (MBZ) revealed that the ketoreduction of MBZ and AMBZ is highly stereoselective. One enantiomer of each metabolite (firstly detected peak in both cases) could only be detected. The CE data revealed that OH-MBZ (mean: 0.715 microg/mL) is the major metabolite followed by AMBZ (mean: 0.165 microg/mL) and OH-AMBZ (mean: 0.055 microg/mL) whereas the MBZ plasma levels (mean: 0.096 microg/mL, levels determined by HPLC) were between those of AMBZ and OH-AMBZ.  相似文献   

11.
A rapid, high resolution, and low sample consumption CZE method is developed for peptide nucleic acid (PNA) analysis for the first time. 30% v/v acetonitrile in PNA sample and 20% v/v acetonitrile in 50 mM borax‐boric acid (pH 8.7) as BGE were employed after optimization. The calibration curves were linear for PNA concentration ranging from 1 to 50 μmol/L. LOD and LOQ of PNA were 0.2 and 1.0 μmol/L, respectively. Since the commercially available reagent gives rise to huge PNA peak and an apparent impurity peak, the purity of PNA was evaluated to be about 81.4% by CZE method, obviously lower than the supplier's purity value of 99.9% evaluated by RP–HPLC, and also lower than 94.8% determined with RP–HPLC by our research group. The CZE method takes only 5 min, needs only 90 nL PNA, much less than 20 min and 20 μL PNA in RP–HPLC method. Moreover, the CZE method is applicable for the analysis of glutamic acid modified and lysine modified PNAs, they show different migration time with their corresponding complementary PNAs. Our results show CZE provides a new choice for PNA and modified PNA analysis, also their purity or quality evaluation.  相似文献   

12.
Gemcitabine (2'2'-difluorodeoxycytidine) is a pyrimidine analog used in the treatment of a variety of solid tumors. After intravenous (i.v.) administration, it is rapidly inactivated to 2'-deoxy-2',2'-difluorouridine (dFdU). A sensitive analytical method for the quantitation of gemcitabine is required for the assessment of alternative dosage and treatment schemes. A rapid and robust RP-HPLC assay for analysis of gemcitabine in human and animal plasma and serum was developed and validated using 2'-deoxyuridine (dU) and 5-fluoro-2'-deoxyuridine (5FdU) as internal standards. It is based on protein precipitation, the use of an Atlantis dC18 column of 100 mm length (inner diameter, 4.6 mm; particle size, 3 microm) and isocratic elution using a 10 mM phosphate buffer, pH 3.0, followed by isocratic elution with the same buffer containing 3% of ACN. For gemcitabine, RSD values for intraday and interday precision were < 4.4 and 5.3%, respectively, the LOQ was 20 ng/mL, and the assay was linear in the range of 0.020-20 microg/mL with an accuracy of > or =89%. The recovery for gemcitabine, dU and 5FdU was 86-98%. The assay was applied to determine gemcitabine levels in plasma samples of patients collected during and shortly after conventional infusion of 25-30 mg/kg body mass (levels: 2.0-18.9 microg/mL) and rats that received lower doses (1.5 mg/kg) via i.v., subcutaneous and oral drug administration (levels: 0.20-2.60 microg/mL). It could also be applied to estimate dFdU levels in human plasma.  相似文献   

13.
HPLC法测定中成药制剂中10-羟基-2-癸烯酸的含量   总被引:6,自引:0,他引:6  
杨江丰  陈理 《色谱》1998,16(2):178-179
采用SpherisorbC18柱,以甲醇∶水∶磷酸(45∶65∶0.5)为流动相,以UV210nm为检测波长,测定中成药制剂中10-羟基-2-癸烯酸(10-HDA)的含量,10-HDA浓度在0.006~0.030g/L范围内线性关系良好(r=0.9999,n=5),检测限为0.2mg/L(S/N=3∶1)。方法具有定量准确、快速及主峰和杂质分离度高等特点。  相似文献   

14.
S M Wu  Y H Ho  H L Wu  S H Chen  H S Ko 《Electrophoresis》2001,22(13):2758-2762
A simple capillary zone electrophoresis (CZE) method is described for the simultaneous determination of cimetidine (CIM), famotidine (FAM), nizatidine (NIZ), and ranitidine (RAN). The analysis of these drugs was performed in a 100 mM phosphate buffer, pH 3.5. Several parameters were studied, including wavelength for detection, concentration and pH of phosphate buffer, and separation voltage. The quantitative ranges were 100-1,000 microM for each analyte. The intra- and interday relative standard deviations (n = 5) were all less than 4%. The detection limits were found to be about 10 microM for CIM, 20 microM for RAN, 20 microM for NIZ, and 10 microM for FAM (S/N = 3, injection 1 s) at 214 nm. All recoveries were greater than 92%. Applications of the method to the assay of these drugs in tablets proved to be feasible.  相似文献   

15.
This work reported that ionic liquid (IL) ([Bmim] [PF6]) and sulfobutylether‐β‐CD (SBE‐β‐CD) were used as electrolyte additives for the separation and determination of camptothecin (CPT) alkaloids by CZE. Separation parameters such as the buffer type, pH, and concentration of the running buffer, the concentration of SBE‐β‐CD and IL, temperature, and separation voltage were all investigated in order to achieve the maximum possible resolution. The four analytes were baseline separated within 10 min in capillary at the separation voltage of 15 kV with a running buffer consisting of 20 mM borate buffer, 20 mM IL, and 100 mM SBE‐β‐CD at pH 9.0. Under such conditions, good linearity about two orders of magnitudes of peak areas was achieved for the investigated CPT alkaloids with the correlation coefficients ranging from 0.9946 to 0.9985. For all analytes, detection limits (S/N = 3) and quantitation limits (S/N = 10) range from 0.05 to 0.92 μg/mL and 0.17 to 3.06 μg/mL, respectively. The proposed method has not only been successfully applied to the separation and determination of CPT alkaloids but also showed that IL seemed to be a promising additive in CZE separation.  相似文献   

16.
A simple, fast, inexpensive and reliable capillary zone electrophoresis (CZE) method for the determination of econazole nitrate in cream formulations has been developed and validated. Optimum conditions comprised a pH 2.5 phosphate buffer at 20 mmol L(-1) concentration, +30 kV applied voltage in a 31.5 cm x 50 microm I.D. capillary. Direct UV detection at 200 nm led to an adequate sensitivity without interference from sample excipients. A single extraction step of the cream sample in hydrochloric acid was performed prior to injection. Imidazole (100 microg mL(-1)) was used as internal standard. Econazole nitrate migrates in approximately 1.2 min. The analytical curve presented a coefficient of correlation of 0.9995. Detection and quantitation limits were 1.85 and 5.62 microg mL(-1), respectively. Excellent accuracy and precision were obtained. Recoveries varied from 98.1 to 102.5% and intra- and inter-day precisions, calculated as relative standard deviation (RSD), were better than 2.0%. The proposed CZE method presented advantageous performance characteristics and it can be considered suitable for the quality control of econazole nitrate cream formulations.  相似文献   

17.
A method based on solid-phase extraction (SPE) coupled to high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) detection was developed for the determination of stavudine in human serum, using didanosine as internal standard. The acquisition was performed in multiple reaction monitoring (MRM) mode. The method was linear over the studied range (10-2000 ng/mL), with r(2) > 0.99, and the run time was 4 min. The intra- and inter-assay precisions (%) were in the ranges 0.1-13.6 and 2.6-9.9, respectively, and the intra- and inter-assay accuracies were >92%. The absolute recoveries were approximately 100% (10 ng/mL), 98% (30 ng/mL), 105% (750 ng/mL) and 105% (1500 ng/mL). The limits of detection and quantitation were 4 and 10 ng/mL, respectively. The analytical method was applied to a bioequivalence study, in which 24 healthy adult volunteers (12 men) received single oral doses (40 mg) of reference and two test stavudine formulations, in an open, three-period, randomized, crossover protocol. The 90% confidence interval of the individual ratios (test formulation/reference formulation) for C(max) (peak serum concentration), AUC(0-10) and AUC(0-inf) (areas under the serum concentration vs. time curve from time zero to 10 h and to infinity, respectively), were in the range 80-125%, which supports the conclusion that the two test formulations are bioequivalent to the reference formulation with respect to the rate and extent of stavudine absorption.  相似文献   

18.
A sensitive, precise, and specific high-performance liquid chromatography (HPLC) method was developed for the assay of lomefloxacin (LFLX) in raw material and tablet preparations. The method validation parameters yielded good results and included the range, linearity, precision, accuracy, specificity, and recovery. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The HPLC separation was performed on a reversed-phase Phenomenex C18 column (150 x 4.6 mm id, 5 microm particle size) with a mobile phase composed of 1% acetic acid-acetonitrile-methanol (70 + 15 + 15, v/v/v), pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 280 nm. The calibration graph for LFLX was linear from 2.0 to 7.0 mg/mL. The interday and intraday precisions (relative standard deviation) were less than 1.0%. The method was applied for the quality control of commercial LFLX tablets to quantitate the drug.  相似文献   

19.
A highly sensitive and specific LC-MS/MS method has been developed and validated for the estimation of zafirlukast (ZFK) with 500 microL human plasma using valdecoxib as an internal standard (IS). The API-4,000 LC-MS/MS was operated under multiple reaction-monitoring mode using the electrospray ionization technique. The assay procedure involved extraction of ZFK and IS from human plasma with ethyl acetate. The resolution of peaks was achieved with 10 mm ammonium acetate (pH 6.4):acetonitrile (20:80, v/v) on a Hypersil BDS C(18) column. The total chromatographic run time was 2.0 min and the elution of ZFK and IS occurred at approximately 1.11 and 1.58 min, respectively. The MS/MS ion transitions monitored were 574.2 --> 462.1 for ZFK and 313.3 --> 118.1 for IS. The method was proved to be accurate and precise at a linearity range of 0.15-600 ng/mL with a correlation coefficient (r) of >or=0.999. The method was rugged with 0.15 ng/mL as lower limit of quantitation. The intra- and inter-day precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of 20 mg ZFK tablet.  相似文献   

20.
A novel assay for the determination of l-asparaginase activity in human plasma is described that is based on the HPLC quantitation of l-aspartic acid produced during enzyme incubation. Methods for monitoring l-asparagine depletion are also described. Chromatography of l-aspartic acid, l-asparagine and l-homoserine (the internal standard) involved derivatization with o-pthaldialdehyde, then separation from other amino acids on a Phenomenex Luna C(18) column using a 1 mL/min flow rate and a mobile phase consisting of di-potassium hydrogen orthophosphate propionate buffer, pH 6, with 10% methanol and 10% acetonitrile. Fluoresence detection was at excitation/emission wavelengths of 357/455 nm. Under these conditions l-aspartic acid, l-asparagine and l-homoserine had retention times of 3.5, 9.8 and 17.7 min, respectively. The l-asparaginase assay was linear from 0.1 to 10 U/mL activity and interday precision and accuracy were less than 13%. The limit of quantitation was approximately 0.03 U/mL. The assay utility was established in 12 children who received E. coli l-asparaginase as treatment for acute lymphoblastic leukaemia.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号