1.
We developed and validated a reversed-phase high-performance liquid chromatographic method with fluorescence detection for the simultaneous determination of YM-64227 [4-cyclohexyl-1-ethyl-7-methylpyrido(2,3-d)pyrimidin-2-(1H)-one], a novel and selective phosphodiesterase type 4 inhibitor, and its fi ve hydroxylated metabolites in dog plasma. The plasma samples were extracted with tert-butyl methyl ether under alkali conditions. The analytes were well separated on a phenyl ethyl column (5 microm, 250 x 4.6 mm i.d.), opreating at 40 degrees C and using an acetonitrile-acetic acid gradient at a fl ow rate of 1.0 mL/min. The fluorescence signal was monitored at an excitation and emission wavelength of 330 and 400 nm, respectively. No interfering peak was observed at the retention time of YM-64227, its metabolites or the internal standard. The validated quantitation range of the method was 0.4-200 ng/mL for all analytes using 0.5 mL of the plasma sample. The recovery of analytes in the extraction process was more than 65.5%. The intra- and inter-assay precision was less than 5.1 and 12.6%, respectively, and the intra- and inter-assay accuracy ranged from -8.1 to 11.8% and -8.0 to 9.9%, respectively. Using this assay, the plasma concentration of YM-64227 and metabolites can be determined after the oral administration of YM-64227 to beagle dogs.  相似文献   

2.
A sensitive and reliable high-performance liquid chromatographic (HPLC) method, using a solid-phase extraction (SPE), was developed and validated for determination of leucovorin (LV) in human plasma. Plasma sample was extracted by using a Sep-Pak cartridge which could be renewable. The sample was analyzed by HPLC with UV detection at 286 nm. The method was shown to perform selectively and sensitively for LV. The main metabolite of LV, 5-methyltetrahydrofolic acid, and endogenous substances in plasma did not show any interference in the analysis. The limit of detection was 10 ng/mL for LV in plasma and the linear range was 50-1500 ng/mL in plasma. The relative standard deviation (RSD) of intra-day and inter-day assays was 2.8-6.1% and 2.4-5.3%, respectively. The extraction recoveries of LV in plasma were over 90%. The method was proved to be applicable to the pharmacokinetic study of LV in healthy volunteers after a single oral administration (75 mg). The pharmacokinetic parameters and relative bioavailability were investigated for domestic LV tablet and capsule vs an imported tablet.  相似文献   

3.
A rapid and sensitive liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of roxatidine in human plasma. Roxatidine was extracted by single liquid-liquid extraction with tert-butyl methyl ether, and the chromatographic separation was performed on a C8 column. The total analytical run time was relatively short (5 min), and the limit of assay quantification was 2 ng/mL using 0.1 mL of human plasma. Roxatidine and the internal standard, propranolol, were monitored in selected ion monitoring (SIM) mode at m/z 307.3 and 260.3, respectively. The standard curve was linear over a concentration range from 2-500 ng/mL, and the correlation coefficients were >0.999. The mean intra- and inter-day assay accuracy ranged from 103.4-108.8% and 102.3-110.0%, respectively, and the mean intra- and inter-day precision was between 3.3-8.8% and 5.3-6.2%, respectively. The developed assay method was successfully applied to a pharmacokinetic study in human volunteers after oral administration of roxatidine acetate hydrochloride at a dose of 75 mg.  相似文献   

4.
A high-performance liquid chromatographic method with fluorescence detection was developed for the determination of (S)-2-[[(7-fluoro-4-indanyl)oxy]methyl]morpholine monohydrochloride (YM992) in plasma. Plasma samples were extracted with n-hexane under alkali condition. After the organic solvent was evaporated to dryness, the residue was treated with 4-fluoro-7-nitrobezofurazan (NBD-F) in borate buffer (pH 7.5) at room temperature for 20 min. The reaction was terminated with hydrochloric acid and the resultant solution was injected onto HPLC without further purification. No interfering peak was observed at the retention time of YM992 or the internal standard. The calibration curve was linear with the concentration of YM992 up to 200 ng/ml. The limit of quantitation was 1 ng/ml. The intra- and inter-day relative standard deviation was less than 5.6% and 4.1%, respectively, and the intra- and inter-day relative error ranged from -3.0% to 17.2% and 2.8% to 7.5%, respectively. Using the assay, the plasma concentration of YM992 could be determined up to 8 and 10 h after the oral administration of YM992 to rats and dogs, respectively.  相似文献   

5.
A sensitive and rapid method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) combined with rapid solid-phase extraction (SPE) has been developed and validated for the quantitative determination of enalapril and its active metabolite enalaprilat in human plasma. After addition of internal standard to human plasma, samples were extracted by 96-well SPE cartridge. The extracts were analyzed by HPLC with the detection of the analyte in the multiple reaction monitoring (MRM) mode. This method for the simultaneous determination of enalapril and enalaprilat was accurate and reproducible, with respective limits of quantitation of 0.2 and 1.0 ng/mL in plasma. The standard calibration curves for both enalapril and enalaprilat were linear (r(2) = 0.9978 and 0.9998) over the concentration ranges 0.2-200 and 1.0-100 ng/mL in human plasma, respectively. The intra- and inter-day precision over the concentration range for enalapril and enalaprilat were lower than 13.3 and 15.4% (relative standard deviation, %RSD), and accuracy was between 89.2-105.0 and 91.9-104.7%, respectively.  相似文献   

6.
A simple and reliable high-performance liquid chromatographic (HPLC) method has been developed for the determination of nodakenin in rat plasma. The concentration of nodakenin was determined in plasma samples after deproteinization with methanol using hesperidin as internal standard. HPLC analysis was performed on a Diamonsil C(18) analytical column using acetonitrile-water (25:75, v/v) as the mobile phase and a UV detection at 330 nm. This method was validated in terms of recovery, linearity, accuracy and precision (intra- and inter-day variation). The extraction recoveries were 91.3 ± 10, 87.8 ± 4.8 and 92.6 ± 5.1 at concentrations of 0.500, 5.00 and 40.0 μg/mL, respectively. The standard curve for nodakenin was linear (r(2) ≥ 0.99) over the concentration range 0.250-50.0 μg/mL with a lower limit of quantification of 0.250 μg/mL. The intra- and inter-day precision (relative standard deviation, RSD) values were not higher than 12% and the accuracy (relative error, RE) was within ± 5.8% at three quality control levels. The validated method was successfully applied for the evaluation of the pharmacokinetics of nodakenin in rats after oral administration of Rhizoma et Radix Notopterygii decoction and nodakenin solution.  相似文献   

7.
A simple HPLC method was developed for determination of quercitrin and isoquercitrin in rat plasma. Reversed-phase HPLC was employed for the quantitative analysis using kaempferol-3-O-beta-D-glucopyranoside-7-O-alpha-L-rhamnoside as an internal standard. Following extraction from the plasma samples with ethyl acetate-isopropanol (95:5, v/v), these two compounds were successfully separated on a Luna C(18) column (250 x 4.6 mm, 5 microm) with isocratic elution of acetonitrile-0.5% aqueous acetic acid (17:83, v/v) as the mobile phase. The flow-rate was set at 1 mL/min and the eluent was detected at 350 nm for both quercitrin and isoquercitrin. The method was linear over the studied ranges of 50-6000 and 50-5000 ng/mL for quercitrin and isoquercitrin, respectively. The intra- and inter-day precisions of the analysis were better than 13.1 and 13.2%, respectively. The lower limits of quantitation for quercitrin and isoquercitrin in plasma were both of 50 ng/mL. The mean extraction recoveries were 73 and 61% for quercitrin and isoquercitrin, respectively. The validated method was successfully applied to pharmacokinetic studies of the two analytes in rat plasma after the oral administration of Hypericum japonicum thunb. ethanol extract.  相似文献   

8.
A reliable and validated reversed-phase high-performance liquid chromatography (HPLC) method using fluorescence detection is reported for the simultaneous quantitation of mycophenolic acid (MPA) and valproic acid (VPA) in human plasma. The method is based on the pre-column derivatization of valproic acid with 4-bromomethyl-6, 7-dimethoxycoumarin (BrMMC) and online solvatochromism of MPA by pH adjustment. The linear calibration range was 0.50-30 microg/mL for MPA and 5.00-150 microg/mL for VPA. The relative standard deviations of the method of intra- and inter-day analyses (n = 6) were below 6.5 and 6.7% for MPA, and 5.8 and 6.3% for VPA, respectively. Dichloromethane was used for the simultaneous extraction of MPA and VPA from acidified plasma. This reliable method can be applied in the analysis of MPA and VPA in human plasma using only a small volume (100 microL).  相似文献   

9.
Combining short-acting and long-acting insulin analogs was a real challenge that was overcome by NovoNordisk through the co-formulation of insulin aspart and insulin degludec in single-dosage form. The proposed study provides a simple, short, and reliable HPLC method with diode array detection that is developed and validated for the simultaneous determination of insulin aspart and insulin degludec in human plasma. The proposed method achieved good separation between the two analytes utilizing a C8 column at 35°C in a very short run time (6 min), with a simple, low-cost, and reliable extraction method through precipitation of plasma protein. Gradient elution was applied using a mobile phase consisting of 0.1 M sodium sulfate (pH 3.4) and acetonitrile. The method was validated according to EMA Guideline on Bioanalytical Validation. The proposed method had a linear range from 3.0 to 300 μg/mL for insulin aspart and from 3.5 to 300 μg/mL for insulin degludec. The intra- and inter-day precision of insulin aspart were 0.36–3.33% and 1.59–8.84%, respectively, and accuracy was between 10.06 and 3.09% The intra- and inter-day precision of insulin degludec were 0.29–1.93% and 0.89–5.14%, respectively, and accuracy was between −5.29 and 3.91%.  相似文献   

10.
A rapid and sensitive LC/MS/MS assay was developed and validated for the determination of clopidogrel in human plasma. Clopidogrel was extracted by single liquid-liquid extraction with pentane, and chromatographic separations were achieved on a C(18) column. The method was validated to demonstrate the specificity, linearity, recovery, lower limit of quantification (LLOQ), stability, accuracy and precision. The multiple reaction monitoring was based on m/z transition of 322.2 --> 211.9 for clopidogrel and 264.1 --> 125.1 for ticlopidine (internal standard). The total analytical run time was relatively short (3 min), and the LLOQ was 10 pg/mL using 0.5 mL of human plasma. The assay was linear over a concentration range from 10 to 10,000 pg/mL (r > 0.999). The intra- and inter-day accuracies were 101.3-108.8 and 98.4-103.5%, respectively, and the intra- and inter-day assay precisions were 1.9-5.5 and 4.4-8.1%, respectively. The developed assay method was applied to a pharmacokinetic study in human volunteers after oral administration of clopidogrel at a dose of 150 mg.  相似文献   

11.
A sensitive and simple HPLC method has been developed and validated for the determination of oxyresveratrol (trans-2,4,3',5'-tetrahydroxystilbene, OXY) and resveratrol (trans-3,5,4'-trihydroxystilbene, RES) in rat plasma. The plasma samples were extracted with ethyl acetate and analyzed using HPLC on an Aglient Zorbax SB-C(18) column (250 x 4.6 mm, 5 microm) at a wavelength 320 nm, with a linear gradient of (A) acetonitrile and (B) 0.5% aqueous acetic acid (v/v), at a flow rate of 1.0 mL/min. The method was linear over the range of 0.1265-25.3 microg/mL for OXY and 0.117-23.4 microg/mL for RES. The extraction recovery for OXY, RES and internal standard ranged from 71.1 to 88.3%. The intra- and inter-day precisions were better than 10%, and the accuracy ranged from 89 to 108%. The validated method was used to study the pharmacokinetic profiles of OXY and RES in rat plasma after oral administration of Smilax china root extract.  相似文献   

12.
An HPLC method was established and validated for the determination of compound FLZ, a synthetic novel anti-Parkinson's disease candidate drug, in rat plasma. FLZ and the internal standard bicyclol were extracted from plasma by solid-phase extraction method and analyzed on a Restek C18 column (4.6 x 250 mm, 5 microm) with a mobile phase consisting of methanol and water (60:40, v/v) at a flow rate of 1.0 mL/min. The detection wavelength was set at 320 nm. The calibration curve was linear within the concentration range from 25 to 500 ng/mL (r2 > 0.999), the limit of quantitation was 25 ng/mL and the average recovery was 92.0% with the RSD less than 5.9%. The relative standard deviation for intra- and inter-day precision was less than 3.8 and 6.9%, respectively. The established HPLC method was validated to be a simple, rapid and reliable procedure and applied to study the preclinical pharmacokinetics of FLZ in rat plasma, and it was the first time that the pharmacokinetics of FLZ had been investigated.  相似文献   

13.
A simple, rapid and reliable high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of curcumin in rat plasma. Plasma was precipitated with acetonitrile after addition of the internal standard (IS), 4-hydroxybenzophenone. Separation was achieved on a Waters muBondapak C(18) column (3.9 x 300 mm, 5 microm) using acetonitrile (55%) and citric buffer, pH 3.0 (45%) as the mobile phase (flow rate = 1.0 mL/min). The UV detection wavelength was 300 and 428 nm for IS and curcumin, respectively. The extraction efficiencies were 97.08, 95.69 and 94.90% for 50, 200 and 1000 ng/mL of curcumin in rat plasma, respectively. The calibration curve was linear over the range 0.02-1 microg/mL with a correlation coefficient of r(2) > 0.999. The intra- and inter-day coefficients of variation were less than 13%, and mean intra- and inter-day errors were less than +/-6% at 50, 200 and 1000 ng/mL of curcumin. This assay was successfully applied to the pharmacokinetic studies of both solubilized curcumin and its polymeric micellar formulation in rats. It was found that polymeric micelles increased the half-life of curcumin 162-fold that of solubilized curcumin and increased the volume of distribution (Vd(ss)) by 70-fold.  相似文献   

14.
Apicidin, a fungal metabolite isolated from Fusarium pallidoroseum, is a cyclic tetrapeptide that exhibits potent anti-protozoal and anti-angiogenic activities. Although extensive studies have been recently conducted to examine the biological and pharmacological action, no information is available on the quantitative analysis of apicidin. To our knowledge, this study is the first to describe a rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) assay method for the quantification of apicidin in rat serum. The method was validated to demonstrate the specificity, linearity, recovery, lower limit of quantification (LLOQ), accuracy, and precision. The multiple reaction monitoring was based on the transitions m/z 624.7 --> 84.3 and 372.1 --> 176.1 for apicidin and trazodone, respectively. The assay utilized a single liquid-liquid extraction and isocratic elution, and the LLOQ was 0.5 ng/mL using 0.1 mL of rat serum. The assay was linear over a range from 0.5-1000 ng/mL, with correlation coefficients >0.9994. The mean intra- and inter-day assay accuracy ranged from 99.9-101.5% and 94.8-102.1%, respectively, and the mean intra- and inter-day precision was between 2.7-5.9% and 1.6-11.5%, respectively. The developed assay method was applied to a pharmacokinetic study after intravenous injection of apicidin in rats at a dose of 1 mg/kg.  相似文献   

15.
A simple and specific high-performance liquid chromatography (HPLC) method was developed for the pharmacokinetic study of vitexin-4″-O-glucoside (VOG) in rats after oral administration. The plasma samples were deproteinised with methanol after the addition of an internal standard, hesperidin. HPLC analysis was performed on a Diamonsil C(18) analytical column, using methanol -0.5% aqueous phosphoric acid (45:55, v/v) as the mobile phase with ultraviolet detection at 330?nm. The calibration curve was linear over the range of 5-450?μg?mL(-1) in rat plasma. The average extraction recovery of VOG was 98.74%?±?0.44%, and the relative standard deviations of the intra- and inter-day precisions were not greater than 4.1% and 2.0%, respectively. The validated method was successfully applied during a pharmacokinetic study in rats after oral administration of VOG at different doses, and all the results indicated that the pharmacokinetics of VOG in rats obeyed nonlinear processes.  相似文献   

16.
A simple and sensitive reversed-phase liquid chromatography method was developed and validated for the determination of nicardipine hydrochloride (NC) in rabbit plasma. Nicardipine hydrochloride and nimodipine, used as internal standard, were initially extracted from plasma by a rapid solid-phase extraction using C(18) cartridges. After extraction, nicardipine hydrochloride was separated by HPLC on a C(18) column and quantified by ultraviolet detection at 254 nm. A mixture of acetonitrile-0.02 M sodium phosphate buffer-methanol (45:40:15) with 0.2% of triethylamine of pH of 6.1 was used as mobile phase. The mean (+/-SD) extraction efficiency of NC was 77.56 +/- 5.4, 84.23 +/- 4.32 and 83.94 +/- 3.87% for drug concentrations of 5, 25 and 100 ng/mL, respectively. The method proved to be linear in the range of 5-100 ng/mL with a regression coefficient of 0.9993. The relative standard deviations of intra- and inter-day analysis for NC in plasma were 3.26-6.52% (n = 5) and 4.71-9.38% (n = 5), respectively. The differences of the mean value measured from the concentration prepared, expressed in percentages (bias percentage), were only - 5.2, 0.4 and 0.8% at NC 5, 25 and 50 ng/mL, which confirmed the accuracy of the method. The analytical technique was used to determine NC plasma concentration after drug oral administration to rabbits. The results inferred that NC is rapidly absorbed in rabbits and has a short half-life (t(1/2) = 1.34 h).  相似文献   

17.
A simple and sensitive reversed-phase liquid chromatography coupled with electrospray-mass spectrometry was developed and validated for the simultaneous determination of rivastigmine, a cholinesterase inhibitor, and its major metabolite NAP 226-90 in rat plasma and brain homogenates. Rivastigmine and NAP 226-90 were extracted from plasma and brain by ethyl acetate and, after drying under nitrogen, re-dissolved in acetonitrile and separated isocratic by HPLC on a C(18) column and quantified by single ion monitoring mass spectrometer. The mean (+/-SD) extraction efficiency for rivastigmine in plasma and brain was 93 +/- 2 and 95 +/- 2% (n = 5) of NAP 226-90 in a drug range of 10-100 pmol/mL or pmol/g. The method proved to be linear within the tested range (regression coefficient, r = 0.9999, n = 5). Intra- and inter-day precision coefficients of variation and accuracy bias were acceptable (within 15%, n = 5) over the entire range for both compounds using plasma or brain samples. The limits of quantification were 0.5 pmol/mL plasma and 2.5 pmol/g brain for rivastigmine and 1 pmol/mL plasma and 5 pmol/g brain for NAP 226-90, respectively. The analytical technique was used to determine the concentrations of rivastigmine and its metabolite NAP 226-90 in rat plasma and brain after oral drug administration. The concentrations of the parent drug and its major metabolite were compared to a pharmacodynamic parameter, the ex vivo inhibition of acetylcholinesterase.  相似文献   

18.
A simple and reliable reversed-phase high-performance liquid chromatography method was developed and validated for the determination of DHP-014, a niguldipine analogue with potent P-glycoprotein inhibitory and negligible calcium channel blocking properties, in rat plasma. DHP-014 and niguldipine hydrochloride (the internal standard) were extracted from rat plasma by liquid extraction using hexane. DHP-014 was then separated by HPLC on a C18 column and quantified by ultraviolet detection at 238 nm. The mobile phase consisted of acetonitrile-aqueous 5 mM phosphate buffer (65:35, v/v) containing 0.4% (v/v) triethylamine adjusted to pH 7.0. The mean extraction efficiency of DHP-014 was 109.0 +/- 12.9, 97.7 +/- 8.0 and 102.9 +/- 7.5% for DHP-014 concentrations of 10, 50 and 100 nM, respectively (n = 5). The method was linear over the concentration range 2.5-200 nM with a regression coefficient of 0.998. The limit of detection of DHP-014 in rat plasma was 1.0 nM. The intra- and inter-day coefficients of variation for DHP-014 in rat plasma were 4.7-7.9 and 6.9-9.9%, respectively. The intra- and inter-day accuracy was 98.2-99.5 and 97.9-103%, respectively. The bioanalytical technique was used to determine DHP-014 in plasma samples in a pharmacokinetic study of DHP-014 administered to female Sprague-Dawley rats.  相似文献   

19.
The present study was to investigate the pharmacokinetics of luteolin-7-O-β-D-glucoside (LGL) and apigenin-7-O-β-D-glucoside (AGL) in rat plasma after intravenous administration of the Humulus scandens extract (HSE). A simple and accurate high-performance liquid chromatographic (HPLC) method was successfully developed for simultaneous determination of LGL and AGL in rat plasma after the plasma protein was precipitated with methanol. HPLC analysis was performed on a C?? column with UV detection at 350?nm and a mobile phase of methanol-0.2% phosphoric acid (1?:?1, v/v). Calibration curves of LGL and AGL were linear over the concentration range of 0.16-20.0 and 0.06-7.20?μg?mL?1, respectively. The accuracy and precision of the two analytes at low, medium and high concentrations were within the range of -3.4% to 8.1%. The relative standard deviations (RSDs) of the intra- and inter-day precisions were less than 11.7% and 10.0%, respectively. The extraction recoveries (n?=?5) varied from 91.9% to 104.1% for LGL and from 92.6% to 109.3% for AGL. The method was fully validated and successfully applied to a pharmacokinetic study of LGL and AGL in rat plasma after the intravenous administration of HSE.  相似文献   

20.
A high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of both remacemide (a novel anticonvulsant and cerebroprotectant) and an active, major metabolite in human plasma. After the addition of an internal standard, the analytes were extracted from the plasma by ion-exchange solid-phase extraction and measured by an isocratic HPLC system with ultraviolet detection at 210 nm. The recovery of the analytes was > 90%. The standard curves were linear over the range of quantitation of approximately 10-500 ng/ml for remacemide itself and 15-250 ng/ml for the metabolite. Both intra-day and inter-day accuracy and precision data were excellent. Remacemide and its metabolite were shown to be stable in human plasma for at least a year when stored at -20 degrees C.  相似文献   