首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A new reversed-phase high performance liquid chromatography with resonance Rayleigh scattering detection (HPLC-RRS) was developed for simultaneous separation and determination of four tetracycline antibiotics (TCs). A good chromatographic separation among the compounds was achieved using a Synergi Fusion-RP column (150 mm × 4.6 mm; 4 μm) and a mobile phase consisting of methanol-acetonitrile-oxalic acid (5 mM) at the flow rate of 0.8 mL min−1. Column temperature was 30 °C. The RRS signal was detected at λex = λem = 370 nm. The recoveries of sample added standard ranged from 95.3% to 103.5%, and the relative standard deviation was below 2.79%. A detection limit of 2.12-5.12 μg mL−1 was reached and a linear range was found between peak height and concentration in the range of 10.36-518.0 μg mL−1 for oxytetracycline (OTC), 12.11-605.5 μg mL−1 for tetracycline (TC), 11.79-589.5 μg mL−1 for chlortetracycline (CTC) and 10.32-516.0 μg mL−1 for doxycycline (DC). The linear regression coefficients were all above 0.999. The method has been applied successfully to the determination of OTC, TC, CTC, DC in pharmaceutical formulations and in honey. The method was simple, rapid and showed a better linear relation and high repeatability.  相似文献   

2.
Four simple, rapid, accurate, precise, reliable and economical spectrophotometric methods have been proposed for simultaneous determination of salbutamol sulphate (SS), bromhexine hydrochloride (BH) and etofylline (ET) in pure and commercial formulations without any prior separation or purification. They were first derivative zero crossing spectrophotometry (method 1), simultaneous equation method (method 2), derivative ratio spectra zero crossing method (method 3) and double divisor ratio spectra derivative method (method 4). The ranges for SS, BH and ET were found to be 1-35 μg mL−1, 4-40 μg mL−1 and 5-80 μg mL−1. For methods 1 and 2, the values of limit of detection (LOD) were 0.2314 μg mL−1, 0.4865 μg mL−1 and 0.2766 μg mL−1 and the values of limit of quantitation (LOQ) were 0.7712 μg mL−1, 1.6217 μg mL−1 and 0.9221 μg mL−1 for SS, BH and ET, respectively. For method 3, LOD values were 0.3297 μg mL−1, 0.2784 μg mL−1 and 0.7906 μg mL−1 and LOQ values were 0.9325 μg mL−1, 0.9282 μg mL−1 and 2.6352 μg mL−1 for SS, BH and ET, respectively. For method 4, LOD values were 0.3161 μg mL−1, 0.2495 μg mL−1 and 0.2064 μg mL−1 and LOQ values were 0.9869 μg mL−1, 0.8317 μg mL−1 and 0.6879 μg mL−1 for SS, BH and ET. The precision values were less then 2% R.S.D. for all four methods. The common excipients and additives did not interfere in their determinations. The results obtained by the proposed methods have been statistically compared by means of Student t-test and by the variance ratio F-test.  相似文献   

3.
Based on CdTe/CdS quantum dots (CdTe/CdS QDs) fluorescence (FL) reversible control, a new and sensitive FL sensor for determination of anthraquinone (AQ) anticancer drugs (adriamycin and daunorubicin) and herring sperm DNA (hsDNA) was developed. Under the experimental conditions, FL of CdTe/CdS QDs can be effectively quenched by AQ anticancer drugs due to the binding of AQ anticancer drugs on the surface of CdTe/CdS QDs and photoinduced electron transfer (PET) process from CdTe/CdS QDs to AQ anticancer drugs. Addition of hsDNA afterwards brought the restoration of CdTe/CdS QDs FL intensity, as AQ anticancer drugs peeled off from the surface of CdTe/CdS QDs and embedded into hsDNA double helix structure. The liner ranges and the detection limits of FL quenching methods for two AQ anticancer drugs were 0.33-9 μg mL−1 and 0.09 μg mL−1 for ADM and 0.15-9 μg mL−1 and 0.04 μg mL−1 for DNR, respectively. The restored FL intensity was proportional to concentration of hsDNA in the range of 1.38-28 μg mL−1and the detection limit for hsDNA was 0.41 μg mL−1. It was applied to the determination of AQ anticancer drugs in human serum and urine samples with satisfactory results. The reaction mechanism of CdTe/CdS QDs FL reversible control was studied.  相似文献   

4.
El-Bagary RI  Elkady EF  Ayoub BM 《Talanta》2011,85(1):673-680
Two reversed-phase liquid chromatographic (RP-LC) methods have been developed for the determination of sitagliptin phosphate monohydrate (STG). The first method comprised the determination of STG alone in bulk and plasma; and in its pharmaceutical preparation. This method was based on isocratic elution of STG using a mobile phase consisting of potassium dihydrogen phosphate buffer pH (7.8)-acetonitrile (70:30, v/v) at a flow rate of 1 mL min−1 with flourometric detection. The flourometric detector was operated at 267 nm for excitation and 575 nm for emission. In the second method, the simultaneous determination of STG and metformin (MET) in the presence of sitagliptin alkaline degradation product (SDP) has been developed. In this method, the ternary mixture of STG, MET and SDP was separated using a mobile phase consisting of potassium dihydrogen phosphate buffer pH (4.6)-acetonitrile-methanol (30:50:20, v/v/v) at a flow rate of 1 mL min−1 with UV detection at 220 nm. Chromatographic separation in the two methods was achieved on a Symmetry® Waters C18 column (150 mm × 4.6 mm, 5 μm). Linearity, accuracy and precision were found to be acceptable over the concentration ranges of 0.25-200 μg mL−1 for STG with the first method and 5-160 μg mL−1, 25-800 μg mL−1 for STG and MET, respectively with the second method. The optimized methods were validated and proved to be specific, robust and accurate for the quality control of the cited drugs in pharmaceutical preparations.  相似文献   

5.
K. Isaac-Olive  A. Chatt 《Talanta》2008,77(2):827-832
Iodine is an essential trace element for human beings. The main source of iodine is generally food items such as fish and milk. Either the lack or the excess of iodine can cause health problems. There exists an increasing interest in the determination of total iodine as well as various species of iodine in milk. We have developed an epithermal neutron activation analysis method with a Compton suppression (ENAA-CS) counting system for the determination of ng mL−1 levels of iodine. We have also employed chemical separation methods prior to ENAA-CS to measure the fraction-specific concentrations of iodine in bovine milk. We have measured the following iodine concentrations in homogenized milk (3.25%milk fat): 0.48 ± 0.02 μg mL−1 of total iodine, 0.020 ± 0.003 μg mL−1 of lipid-bound iodine, 0.039 ± 0.002, 0.019 ± 0.002 and 0.021 ± 0.004 μg mL−1 of protein-bound iodine depending on the protein separation method and 0.45 ± 0.02 μg mL−1 of inorganic species.  相似文献   

6.
A simple, precise, accurate and validated, acetonitrile-free, reverse phase high performance liquid chromatography (HPLC) method is developed for the determination of melamine in dry and liquid infant formula. The separation is performed on a Kromasil C18 column (150 mm × 3.2 mm I.D., 5 μm particle size) at room temperature. The mobile phase (0.1% TFA/methanol 90:10) is pumped at a flow rate of 0.3 mL min−1 with detection at 240 nm. Melamine elutes at 3.7 min. A linear response (r > 0.999) is observed for samples ranging from 1.0 to 80 μg mL−1. The method provides recoveries of 97.2-101.2% in the concentration range of 5-40 μg mL−1, intra- and inter-day variation in <1.0% R.S.D. The limit of detection (LOD) and limit of quantification (LOQ) values are 0.1 μg mL−1 and 0.2 μg mL−1, respectively.  相似文献   

7.
A novel method for determination of indole-3-acetic acid (IAA) and indole-3-butyric acid (IBA) in an extract from mung bean sprouts using high performance liquid chromatography (HPLC) with chemiluminescence (CL) detection is described. The method is based on the CL reaction of auxin (indole-3-acetic acid and indole-3-butyric acid) with acidic potassium permanganate (KMnO4) and tris(2,2′-bipyridyl)ruthenium(II), which was immobilized on the cationic ion-exchange resin. The chromatographic separation was performed on a Nucleosil RP-C18 column (i.d.: 250 mm × 4.6 mm, particle size: 5 μm, pore size: 100) with an isocratic mobile phase consisting of methanol-water-acetic acid (45:55:1, v/v/v). At a flow rate of 1.0 mL min−1, the total run time was 20 min. Under the optimal conditions, the linear ranges were 5.0 × 10−8 to 5.0 × 10−6 g mL−1 and 5.0 × 10−7 to 1.0 × 10−5 g mL−1 for IAA and IBA, respectively. The detection limits were 2.0 × 10−8 g mL−1 and 2.0 × 10−7 g mL−1 for IAA and IBA, respectively. The relative standard deviation (RSD) of intra-day were 3.1% and 2.3% (n = 11) for 2 × 10−6 g mL−1 IAA and 2 × 10−6 g mL−1 IBA; The relative standard deviations of inter-day precision were 6.9% and 4.9% for 2 × 10−6 g mL−1 IAA and 2 × 10−6 g mL−1 IBA. The proposed method had been successfully applied to the determination of auxin in mung bean sprouts.  相似文献   

8.
Rapid analytical method for the simultaneous separation and determination of amines and organic acids is a vital interest for quality control of citrus and their products. In the present study, a simultaneous high performance liquid chromatography (HPLC) method for the rapid separation of three amines and two organic acids was developed. Chromatographic separation of compounds was achieved using Xbridge C18 column at ambient temperature, with an isocratic mobile phase of 3 mM phosphoric acid at a flow rate of 1.0 mL min−1. A photodiode array (PDA) detector was used to monitor the eluent at 223 nm and 254 nm with a total analysis time of 10 min. Extraction of amines and organic acids from citrus juice was optimized. The method was validated by tests of linearity, recovery, precision and ruggedness. The limit of detection (LOD) and limit of quantification (LOQ) for amines and ascorbic acid were determined to be 5 ng and 9.8 ng, respectively. All calibration curves showed good linearity (R2 ≥ 0.9999) within the test ranges. The recoveries of the amines and organic acids ranged between 84% and 117%. The identity of each peak was confirmed by mass spectral (MS) analysis. The developed method was successfully applied to analyze the content of amines and organic acids in six different species and two varieties of citrus. Results indicate that mandarin and Marrs sweet orange contain high level of amines, while pummelo and Rio Red grapefruit had high content of ascorbic acid (137-251 μg mL−1) and citric acid (5-22 mg mL−1). Synephrine was the major amine present in Clementine (114 μg mL−1) and Marrs sweet orange (85 μg mL−1). To the best of our knowledge, this is the first report on simultaneous separation and quantification of amines and organic acids in Marrs sweet orange, Meyer lemon, Nova tangerine, Clementine, Ugli tangelo and Wekiwa tangelo.  相似文献   

9.
A novel method was developed for the determination of amiodarone and desethylamiodarone by high-performance liquid chromatography (HPLC) coupled with chemiluminescent (CL) detection. The procedure is based on the post-column photolysis of the analytes into photoproducts which are active in the tris(2,2′-bipyridyl)ruthenium(III) [Ru(bpy)33+] CL system. Ru(bpy)33+ was on-line generated by photo-oxidation of the Ru(II) complex in the presence of peroxydisulfate. The separation was carried out on a Mediterranea C18 column with isocratic elution using a mixture of methanol and 0.017 mol L−1 ammonium sulfate buffer of pH 6.8. Under the optimum conditions, analytical curves, based on standard solutions, were linear over the range 0.1-50 μg mL−1 for amiodarone and 0.5-25 μg mL−1 for desethylamiodarone. The detection limits of amiodarone and desethylamiodarone were 0.02 and 0.11 μg mL−1, respectively. Intra- and inter-day precision values of 0.9% relative standard deviation (R.S.D.) (n = 10) and 1.6% R.S.D. (n = 15), respectively, were obtained. The method was applied successfully to the determination of these compounds in serum and pharmaceutical formulations.  相似文献   

10.
A new straightforward method based on cloud-point extraction (CPE) was developed to determine osthole in rat plasma by reversed phase high-performance liquid chromatography with ultraviolet detection using a photodiode array detector. The non-ionic surfactant Triton X-114 was chosen as the extract solvent. Variable parameters affecting the CPE efficiency were evaluated and optimized. A Zorbax SB-C18 column was used for elution separation at 25 °C with detection wavelength at 322 nm. Under the optimum conditions, the method was shown to be reproducible and reliable with intra-day precision below 7.62%, inter-day precision below 6.37%, and accuracy within ±5.02% and mean extraction recovery more than 90.4%, which were all calculated using a range of spiked samples at three concentrations of 0.5, 5.0 and 15.0 μg mL−1 for osthole in plasma. The calibration curve for the analyte was linear in the range from 0.1 to 20 μg mL−1 with the correlation coefficients greater than 0.9981. Limit of detection (S/N = 3) was less than 0.03 μg mL−1and limit of quantification (S/N = 10) was less than 0.1 μg mL−1. After strict validation, the method was successfully applied to the pharmacokinetic study of osthole in rats after oral and intravenous administration, respectively.  相似文献   

11.
An on-line method, based on coupling dynamic ultrasonic extraction (DUE), continuously sampling the suspension of sample and solvent, high performance liquid chromatographic separation with diode array detection, has been developed for the determination of the flavonoids, including baicalin, baicalein and wogonin, from the root of Scutellaria baicalensis Georgi. Variables influencing the DUE were evaluated by orthogonal test. The extraction yields of baicalin, baicalein and wogonin in the roots of S. baicalensis Georgi obtained from five different cultivated areas are 73.8–131.5 μg mg−1 (RSD ≤ 6.24%), 6.8–15.9 μg mg−1 (RSD ≤ 5.36%) and 4.4–14.3 μg mg−1 (RSD ≤ 5.30%), respectively. The limits of detection for baicalin, baicalein and wogonin are 0.30, 0.37 and 0.41 μg mL−1, respectively. Linearity is from 0.55 to 109 μg mL−1 for baicalin, from 0.51 to 105 μg mL−1 for baicalein and from 0.53 to 102 μg mL−1 for wogonin. Compared with off-line continuous flow-DUE, the proposed method would be more convenient for the determination of the analytes and the rapid optimization of the extraction process. The extraction yields of flavonoids obtained by the proposed method are comparable with those obtained by dynamic microwave assisted extraction, static ultrasonic extraction and reflux extraction. The result indicated that the proposed method is suitable to determine the active components in Chinese herbal medicine.  相似文献   

12.
A new, simple and highly sensitive method for spectrofluorimetric determination of amiloride (AMI) and furosemide (FUR) in pharmaceuticals is presented. The proposed method is based on the separation of AMI from FUR by solid-phase extraction using a nylon membrane, followed by spectrofluorimetric determination of both drugs, on the solid surface and the filtered aqueous solution, respectively. AMI shows low native fluorescence, but its separation-preconcentration by immobilization (solid-phase extraction) on nylon membrane surface provides a considerable enhancement in fluorescence intensity. The fluorescence determination is carried out at λex = 237, λem = 415 nm for FUR; and λex = 365, λem = 406 nm for AMI. The calibration graphs are linear in the range 3.20 × 10−4 to 0.8 μg mL−1and 1.33 × 10−3 to 4.0 μg mL−1, for AMI and FUR, respectively, with a detection limit of 9.62 × 10−5 and 4.01 × 10−4 μg mL−1 (S/N = 3). The commonly found excipients in commercial pharmaceutical formulations do not interfere. The developed method is successfully applied to the determination of both drugs in pharmaceutical formulations.  相似文献   

13.
B. Zargar  H. Parham  A. Hatamie 《Talanta》2009,77(4):1328-1331
This study presents a novel separation, preconcentration and determination of basic fuchsin (BF) in an aqueous solution by sodium dodecyl sulfate (SDS)-bounded iron oxide nanoparticles (S-IONPs). It is shown that the novel magnetic nano-adsorbent is quite efficient for the adsorption and desorption of BF at 25 °C. Different parameters such as pH, temperature, ionic strength and composition of desorbent solvent were optimized. The effect of some co-existing ions on the determination was investigated. The nanoparticles were analyzed by transmission electron microscopy (TEM) and the sizes of S-IONPs were in the range of 20-100 nm. The method showed good linearity for the determination of BF in the range of 10-300 ng mL−1 with a regression coefficient of 0.9989. The limit of detection (LOD) (signal-to-noise ratio of 3:1) was 0.0073 μg L−1 and the relative standard deviation (RSD) for 0.03 μg mL−1 and 0.2 μg mL−1 of BF were 4.53% and 4.73%, respectively. The BF was determined successfully in spiked samples of Karoon River water.  相似文献   

14.
Sequential injection chromatography system equipped with miniaturized 10 mm monolithic column was used for fast simultaneous determination of two pesticides—fenoxycarb (FC) and permethrin (PM). The system was composed of a commercial sequential injection analysis (SIA) system (FIAlab® 3000, 6-port selection valve and 5.0 mL syringe pump), commercially available column Chromolith™ RP-18e (10 mm × 4.6 mm i.d.) (Merck®, Germany) and CCD UV-vis detector (USB 2000, Ocean-optics) with 1.0 cm Z-flow cell, absorbance was monitored at 225 nm. The mobile phase used for analysis was acetonitrile/water (60:40, v/v), flow rates were 0.6 mL min−1 for elution of fenoxycarb and 1.2 mL min−1 for elution of permethrin. For each analysis 4.8 mL of mobile phase was used. The chromatographic resolution between both compounds was >8 and analysis time was <6.5 min under the optimal conditions. Limits of detection were determined at 2.0 μg mL−1 for fenoxycarb and 1.0 μg mL−1 for permethrin. Samples were prepared by diluting with mobile phase and injected volume was 10 μL for each analysis. Developed method was applied to analysis of both pesticides in veterinary pharmaceutical foams and sprays ARPALIT® Neo (Aveflor, Czech Republic). SIC method was compared with validated method (HPLC, reverse phase 100 mm monolithic column, gradient elution).  相似文献   

15.
In the present work, a new ligandless-dispersive liquid-liquid microextraction (LL-DLLME) method has been developed for preconcentration trace amounts of copper as a prior step to its determination by flame atomic absorption spectrometry. In the proposed approach 1,2-dicholorobenzene and ethanol were used as extraction and dispersive solvents, respectively. Some factors influencing on the extraction efficiency of copper and its subsequent determination were studied and optimized, such as the extraction and dispersive solvent type and volume, pH of sample solution, extraction time and salting out effect. Under the optimal conditions, the calibration curve was linear in the range of 1.0 ng mL−1-0.6 μg mL−1 of copper with R2 = 0.9985. Detection limit was 0.5 ng mL−1 in original solution (3Sb/m) and the relative standard deviation for seven replicate determination of 0.2 μg mL−1 copper was ±1.4%. The proposed method has been applied for determination of copper in standard and water samples with satisfactory results.  相似文献   

16.
A novel chemiluminescence (CL) reaction system with bis(hydrogenperiodato) argentate(III) complex anion (Ag(III) complex, [Ag(HIO6)2]5−), for the first time, is developed for the determination of lomefloxacin (LMFX), enrofloxacin (ENLX) and pefloxacin (PFLX). The possible CL emission mechanism was discussed by comparing the fluorescence emission with CL spectra. The CL conditions of [Ag(HIO6)2]5−-H2SO4-LMFX/ENLX/PFLX systems were investigated and optimized. Under the optimized experimental conditions, the CL intensity is proportional to the concentration of the drugs in the range 0.2994-36.80 × 10−7 g mL−1 for LMFX, 4.00-30.0 × 10−7 g mL−1 for ENLX and 1.54-27.64 × 10−7 g mL−1 for PFLX. The limit of detection (s/n = 3) was 9.1 × 10−9 g mL−1 for LMFX, 3.1 × 10−9 g mL−1 for ENLX and 4.4 × 10−9 g mL−1 for PFLX. The recovery of LMFX, ENLX and PELX from the spiked pharmaceutical preparations was in the range of 92.3-105% with the RSDs of 0.5-2.7%. For urine, serum and milk samples the recoveries of the three drugs were in the range of 85.1-107% for LMFX with the RSDs of 2.3-3.4%. 80.2-112% for ENLX with the RSDs of 1.4-2.8%, and 87.8-114% for PFLX with the RSDs of 1.6-2.7%. The proposed method was applied successfully to the determination of these compounds in real samples.  相似文献   

17.
A simple, sensitive, and specific method with gas chromatography-mass spectrometry was developed for simultaneous extraction and derivatization of amphetamines (APs) and 3,4-methylenedioxyamphetamines (MDAs) in human urine by using a monolithic silica spin column. All the procedures, such as sample loading, washing, and elution were performed by centrifugation. APs and MDAs in urine were adsorbed on the monolithic silica and derivatized with propyl chloroformate in the column. Methamphetamine-d5 was used as an internal standard. The linear ranges were 0.01-5.0 μg mL−1 for methamphetamine (MA) and 3,4-methylenedioxymethamphetamine (MDMA) and 0.02-5.0 μg mL−1 for amphetamine (AP) and 3,4-methylenedioxyamphetamine (MDA) (coefficient of correlation ≧0.995). The recovery of APs and MDAs in urine was 84-94%, and the relative standard deviation of the intra- and interday reproducibility for urine samples containing 0.1, 1.0, and 4.0 μg mL−1 of APs and MDAs ranged from 1.4% to 13.6%. The lowest detection limit (signal-to-noise ratio ≧ 3) in urine was 5 ng mL−1 for MA and MDMA and 10 ng mL−1 for AP and MDA. The proposed method can be used to perform simultaneous extraction and derivatization on spin columns that have been loaded with a small quantity of solvent by using centrifugation.  相似文献   

18.
A quantitative method of capillary electrophoresis with sample stacking induced by moving reaction boundary (MRB) was developed for sensitive determination of oxymatrine (OMT) and matrine (MT) in rat plasma. The experimental conditions were optimized firstly. Below are the optimized experimental conditions: 20 mM sodium formate solution (HCOONa, adjusted to pH 10.70 by ammonia) as sample solution, 3 min 14 mbar sample injection, 40 mM formic buffer (HCOOH-HCOONa, pH 2.60) as stacking buffer, 7 min 14 mbar injection of stacking buffer, 100 mM HCOOH-HCOONa (pH 4.80) as separation buffer, 73 cm capillary (effective length 64 cm), 21 kV voltage, 210 nm wavelength. Under the optimized conditions, higher than 60-fold sensitivity improvement of the stacking was simply achieved as compared with capillary zone electrophoresis, and the detectable limits obtained for OMT and MT were 0.26 and 0.19 μg mL−1, respectively. Then, numerous demonstrations were carefully performed for the methodological validations of OMT and MT in rate plasma, including high specificity of method, good linearity (r = 0.9993 for OMT, r = 0.9991 for MT), fair wide linear concentration range (1.30-65.00 μg mL−1 for OMT, 0.84-42.00 μg mL−1 for MT), low limit of detection (1.03 μg mL−1 for OMT, 0.38 μg mL−1 for MT), less than 5% intra- and inter-day variance value, and higher than 96% recovery of OMT and MT in plasma. The developed method could be used for the trace analyses of OMT and MT in plasma and was finally used for the investigation on pharmacokinetic study of OMT in rat plasma.  相似文献   

19.
In this work, a stable electrogenerated chemiluminescence (ECL) detector was developed. The detector was prepared by packing cation-exchanged resin particles in a glass tube, followed by inserting Pt wires (working electrode) in this tube and sealing. The leakage of Ru(bpy)32+ can be compensated by adding a small amount of Ru(bpy)32+ into solution phase. Coupled with high-performance liquid chromatography separation, the detector has been used for determination of itopride hydrochloride in human serum. Under the optimal conditions, the ECL intensity has a linear relationship with the concentration of itopride hydrochloride in the range of 1.0 × 10−8 g mL−1 to 1.0 × 10−6 g mL−1 and the detection limit was 3 × 10−9 g mL−1 (S/N = 3). The as-prepared ECL detector displayed good sensitivity and stability.  相似文献   

20.
A flow injection analysis (FIA) method using on-line separation and preconcentration with a novel metal scavenger beads, QuadraSil™ TA, has been developed for the ICP-OES determination of traces of palladium. QuadraSil TA contains diethylenetriamine as a functional group on spherical silica beads and shows the highest selectivity for Pd(II) at pH 1 (0.1 mol l−1 hydrochloric acid) solution. An aliquot of the sample solution prepared as 0.1 mol l−1 in hydrochloric acid was passed through the QuadraSil TA column. After washing the column with the carrier solution, the Pd(II) retained on the column was eluted with 0.05 mol l−1 thiourea solution and the eluate was directly introduced into an ICP-OES. The proposed method was successfully applied to the determination of traces of palladium in JSd-2 stream sediment certified reference material [0.019 ± 0.001 μg g−1 (n = 3); provisional value: 0.0212 μg g−1] and SRM 2556 used auto catalyst certified reference material [315 ± 4 μg g−1 (n = 4); certified value: 326 μg g−1]. The detection limit (3σ) of 0.28 ng ml−1 was obtained for 5 ml of sample solution. The sample throughputs for 5 ml and 100 μl of the sample solutions were 10 and 15 h−1, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号