Capillary zone electrophoresis is proposed for the determination of magnesium and calcium ions in seawater. A carrier solution containing EDTA was adopted for the complexation of these ions and the effect of sodium chloride concentration in the sample solutions on the results was examined. It was found that magnesium and calcium ions could be determined without any pretreatment by injecting 100-fold diluted seawater samples. Linear calibration graphs were obtained for standard solutions containing up to 10.0 mg/l of calcium ion when both peak area and peak height were used. On the other hand, a linear calibration graph was obtained for standard solutions containing up to 20.0 mg/l of magnesium ion when the peak area was used, while a curved one was obtained when the peak height was used. Relative standard deviations were 0.8 and 1.2% when a standard solution containing 5.0 mg/l of magnesium and 8.0 mg/l of calcium ions was analysed 8 times using the peak area. Limits of detection for magnesium and calcium ions were 0.13 and 0.26 mg/l, respectively. The proposed method was applied to the determination of magnesium and calcium ions in surface and bottom seawater samples.  相似文献   

2.
建立了毛细管区带电泳(CZE)中场放大样品堆积(FASS)技术分析尿液中苯丙胺类毒品的方法。采用体积分数30%甲醇的100 mmol/L磷酸盐(pH 3)为分离缓冲液,利用缓冲体系与样品溶液体系电导率的差异,在毛细管中浓缩样品组分,对苯丙胺、甲基苯丙胺、3,4-(亚甲二氧基)苯丙胺(MDA)、3,4-(亚甲二氧基)甲基苯丙胺(MDMA)4种毒品进行了分离和定量测定,与常规毛细管区带电泳比较,检测灵敏度提高约2000倍。采用利多卡因为内标,对添加上述4种毒品的尿液进行提取和测定,分析的相对标准偏差在15%范围之内,可检测到的上述毒品质量浓度为0.002μg/mL,相对回收率在70%~120%内。该方法可用于生物检材中苯丙胺类毒品的检测。  相似文献   

3.
Ethyl glucuronide (EtG), a metabolite of ethanol, is a marker of recent alcohol consumption. In the past few years, its analysis in body fluids has attracted considerable attention because it closes a gap between short time and long time alcohol markers such as ethanol and carbohydrate-deficient transferrin, respectively. The capillary zone electrophoresis (CZE) analysis of EtG in model mixtures and human serum is reported using uncoated and coated fused-silica capillaries together with acidic buffers in the pH range between 3.2 and 4.4 and indirect detection. In these approaches, separation of EtG from endogenous macro- and microcomponents (anionic serum components of high and low concentration, respectively) is based upon transient isotachophoretic stacking referred to as sample self-stacking. The selection of a favorable bufferco-ion and pH is shown to be crucial for optimized sensitivity. Abuffercomposed of 10 mM nicotinic acid and epsilon-aminocaproic acid (pH 4.3) is demonstrated to provide a detection limit for EtG in serum of 0.1 microg/ml, a value that is relevant for clinical and forensic purposes.  相似文献   

4.
A simple and sensitive method has been developed for the determination of chloroacetic acids and acetic acid in water using capillary zone electrophoresis under modified electroosmotic flow with indirect UV detection. Potassium hydrogen phthalate at pH 5.40 was used as background electrolyte (BGE), and hexadecyltrimethylammonium bromide was used as electroosmotic flow modifier. Field-amplified sample injection (FASI) method was used to enhance the sensitivity. Results showed that the limit of detection for these analytes was enhanced more than 15-fold and the repeatabilities were good with relative standard deviations (RSDs %) of migration time and corrected peak areas being below 0.33%, 4.45% (intra-day) and 0.87%, 9.67% (inter-day), respectively. An off-line liquid–liquid extraction (LLE) process with methyl tert-butyl ether was carried out to detect these compounds in water samples. The dissociation constants of acetic acid and monochloroacetic acid (MCA) were determined with two methods and the results obtained were consistent with the reference values.  相似文献   

5.
毛细管区带电泳法测定粉针剂中头孢拉定的含量   总被引:3,自引:0,他引:3  
用毛细管区带电泳法测定头孢拉定的含量 ,未涂层毛细管柱 (75 μm×48.5cm ,有效长度 40cm) ,电压 2 8kV ,检测波长 2 3 0nm ,温度 2 0℃ ,进样 5×1 0 3Pa× 3s。运行缓冲液为 2 5mmol/L硼砂缓冲液。方法的线性范围 3 1 .2 2μg/mL~ 749.2 8μg/mL ,检测限为 1 .1 7μg/mL。  相似文献   

6.
Jastrzebska A 《Talanta》2006,69(4):1018-1024
The usefulness of zone capillary electrophoresis (CZE) in combination with isotachophoresis (cITP) as on-line preconcentration technique was examined for analysis of tripolyphosphate (STPP) in meat and meat products. The mean concentrations of STPP in different types of meat products varied from 39 mg P2O5/100 g to 219 mg P2O5/100 g, these values are below the legal requirements. The detection (LOD) and quantification (LOQ) limits for STPP in extracted solutions were 0.80 mg P2O5/dm3 and 2.69 mg P2O5/dm3, respectively. Obtained results were compared with the Kjeldahl method. Accuracy (97.4-98.3%) was determined using recovery assay based on standard additions method. Precision was evaluated by within-day R.S.D. (1.40-2.19%), between-days R.S.D. (3.00-3.82%) and demonstrates the benefit of using this procedure for the routine analysis of STPP in meat and their products. The F-Snedecor test was employed to compare the precision of the used methods and calculated F-test values (4.00, 6.13) were less than the theoretical (6.39).  相似文献   

7.
We describe a combination of selected ions as a terminating ion which is useful for transient isotachophoresis (ITP) in capillary zone electrophoresis (CZE) for the determination of nitrite and nitrate in seawater. In addition to 150 mM sulfate as the principal terminating ion, 10 mM bromate was added to a sample solution as the additional terminating ion. Artificial seawater containing 3 mM cetyltrimethylammonium chloride (CTAC) was adopted as a background electrolyte (BGE). The limits of detection (LODs) for nitrite and nitrate were 2.2 and 1.0 microg/L (as nitrogen), respectively. The LODs were obtained at a signal to noise ratio (S/N) of 3. The values of the relative standard deviation (RSD) of peak area for these ions were 1.9 and 1.4%. The RSDs of peak height were 1.7 and 1.9%, the RSDs of migration time 0.11%. The proposed method was applied to the determination of nitrite and nitrate in a proposed certified reference material for nutrients in seawater, MOOS-1, distributed by the National Research Council of Canada (NRC). The results almost agreed with the assigned tolerance interval.  相似文献   

8.
Tissue level of nitrate and nitrite are established indicators of altered nitric oxide metabolism under various pathological conditions. Determination of these anions in biological samples, in the presence of high chloride concentration, using capillary zone electrophoresis suffers from poor detection sensitivity. Separation conditions providing excellent resolution and submicromolar detection sensitivity of nitrate and nitrite have been developed and validated. Simple sample preparation was applied that maintains nitrite stability in tissue extracts and at the same time allows transient isotachophoresis stacking of the analytes. Nitrate and nitrite concentrations in rat brain and liver tissue samples were determined in control and lipopolysaccharide treated animals.  相似文献   

9.
On-line sample preconcentration of oligonucleotides with a new sweeping carrier was developed by using dodecyltrimethylammonium bromide (DTAB) below the critical micelle concentration (CMC). The sweeping results with DTAB below and above the CMC were compared. The use of DTAB below the CMC benefits the preconcentration of the oligonucleotides, while the use of DTAB above the CMC is good for hydrophobic small molecules. The factors affecting the sweeping results were optimized and this method was evaluated by constructing calibration curves for thrombin aptamers. The sweeping scheme produced a 112-fold sensitivity enhancement for the oligonucleotides relative to that run in a running buffer without DTAB. The sweeping method developed here can be a good reinforcement of the preconcentration scheme by sweeping when less-hydrophobic analytes or large negatively-charged molecules need to be preconcentrated.  相似文献   

10.
A simple, rapid and reproducible capillary isotachophoretic on-line coupled with capillary zone electrophoresis (CITP-CZE) method for the determination of IMz in food packaging extracts and its residues in apples is described. A good separation of the IMZ from other sample constituents was achieved within 15 minutes without any sample clean up. Method characteristics (linearity, accuracy, intra-assay and detection limit) were determined. Less amount of time involved, sufficient sensitivity and low running cost are the important attributes of CITP-CZE method.  相似文献   

11.
We describe capillary zone electrophoresis (CZE) for the simultaneous determination of bromide, nitrite and nitrate ions in seawater. Artificial seawater was adopted as the carrier solution to eliminate the interference of high concentrations of salts in seawater. The artificial seawater was free from bromide ion to enable the determination of bromide ion in a sample solution. For the purpose of reversing the electroosmotic flow (EOF), 3 mM cetyltrimethylammonium chloride (CTAC) was added to the carrier solution. A 100 microm ID (inside diameter) capillary was used to extend the optical path length. The limits of detection (LODs) for bromide, nitrite, and nitrate ions were 0.46, 0.072, and 0.042 mg/L (as nitrogen), respectively. The LODs were obtained at a signal to noise ratio (S/N) of 3. The values of the relative standard deviation (RSD) of peak area for these ions were 1.1, 1.5, and 0.97%. The RSDs of migration time for these ions were 0.61, 0.69, and 0.66%. Artificial seawater samples containing various concentrations of bromide, nitrite, and nitrate ions were analyzed by the method. The error was less than +/-12% even if the concentration ratio of bromide ion to nitrite or nitrate ion was 20-240. The proposed method was applied to the determination of bromide, nitrite, and nitrate ions in seawater samples taken from the surface and the seabed. These ions in other environmental waters such as river water and rainwater samples were also determined by ion chromatography (IC) as well as this method.  相似文献   

12.
The combination of cathodic amperometric detection with capillary zone electrophoresis is demonstrated to be a versatile method for the quantification of organic and inorganic peroxides. A gold microelectrode, polarized at -600 mV against an Ag/AgCl reference electrode, is placed at the end of the capillary. Since the electroosmotic flow purges the detector electrode from oxygen, no degassing of the detector cell or the sample is necessary. With an injection volume of ca. 1 nl, hydrogen peroxide, peroxosulfate, peroxy alkanoic acids and the hydroperoxides of linoleic acid can be detected down to 10 micromol/l. Separation of the isomeric hydroperoxides of the unsaturated fatty acids is achieved by addition of beta-cyclodextrin to the electrolyte.  相似文献   

13.
We describe capillary zone electrophoresis (CZE) with transient isotachophoresis (ITP) for the determination of low concentrations of nitrite and nitrate ions in seawater. Bromide-free artificial seawater was adopted as background electrolyte (BGE) to eliminate the interference of high concentrations of salts in seawater. To reverse the electroosmotic flow (EOF), 3 mM cetyltrimethylammonium chloride (CTAC) was added to the BGE. High concentrations of chlorate were added to sample solutions as the terminating ion to generate the ITP process before the CZE separation. In general, the stacking effect increased with increasing amounts of chlorate injected into the capillary. The limits of detection (LODs) for nitrite and nitrate were 0.063 and 0.033 mg/L when the chlorate concentration was 600 and 200 mM, respectively; these were half of those obtained by CZE without the transient ITP. The LODs were obtained at a signal to noise ratio (S/N) of 3. The relative standard deviations (RSD, n = 10) of the peak areas for these ions were 3.2 and 2.9%. The RSDs of peak heights for these ions were 1.6 and 2.1%. The RSDs of migration times for these ions were 0.67 and 0.46%.  相似文献   

14.
A simple and rapid capillary zone electrophoresis (CZE) method for the determination of aristolochic acid (AA) in dietary supplements and selected herbs is described. A clear separation of AA from other sample constituents was achieved within 5 minutes without any sample clean up. A mixture of 20 mM-morpholinethanesulphonic acid+10 mM-BisTrisPropane+0.2% hydroxyethylcelullose in 10% methanol serves as a background electrolyte. The linearity, accuracy, intra-assay and detection limit of the developed method are 200–6000 ng/mL, 95–103%, 3.5%, and 50 ng/ml, respectively. Ease of use, sufficient sensitivity and low running cost are the most important attributes of the CZE method. The proposed CZE method was compared with HPLC.  相似文献   

15.
A method is described for the determination of fosfomycin in pus by capillary zone electrophoresis with reversed electroosmotic flow, and indirect UV absorbance detection. Sample pre-treatment is limited to removal of proteins and cell debris by adding the double volume of methanol, followed by vortexing for few seconds, and centrifugation at 15,000 x g for 2 min. The supernatant is directly injected into the instrument. Fosfomycin is separated from sample constituents with a background electrolyte at pH 7.25 (25 mM benzoate buffer with 0.5 mM hexadecyltrimethylammonium bromide added, adjusted to pH with tris(hydroxymethyl)-aminomethane (TRIS)). Separation is carried out in a capillary with 50 microm I.D., 64.5 cm total length, 56.0 cm to the detector, at 25 degrees C with -25 kV voltage applied. Due to the low absorbance of the analyte, indirect UV detection was performed at 254 nm using a bubble cell capillary. Sample was injected by pressure (450 mbar s). Repeatability for fosfomycin in spiked pus (from 8 or 10 consecutive injections of three different series at concentrations of 100 microg/mL of the antibiotic) was between 2.4 and 8.2% relative standard deviation (RSD). Accuracy (expressed as recovery of fosfomycin determined by three independent analysis at 10, 100 and 300 microg/mL fosfomycin added to plain pus) was between 75 and 102%. Intermediate reproducibility (n = 9 at three different days) was between 2 and 12% RSD. Limit of detection and limit of quantitation were 4.5 and 15 microg/mL, respectively. The concentration of fosfomycin in pus of patients treated with the antibiotic ranged up to 240 microg/mL. The concentration of other anionic pus constituents identified beside chloride (acetate, succinate, lactate, phosphate) ranged between 20 and 7800 microg/mL.  相似文献   

16.
A systematic investigation of optimal conditions for determining the homologues of linear alkylbenzenesulfonates (LAS) by capillary zone electrophoresis (CZE) using the large-volume sample stacking technique was presented. The most effective sample stacking and separation conditions was 20 mM borate buffer with 30% acetonitrile at pH 9.0, and the sample hydrodynamic injection of up to 90 s at 4 p.s.i. (1 p.s.i. = 6,892.86 Pa) (around 711 nl). Under such conditions, approximately a 100-fold enrichment factor was achieved based on peak heights. The reproducibility of migration time and quantitative results of stacking CZE can be improved by using internal standards. Quantitation limits of the homologues of LAS were 0.002-0.01 mg/l under these enrichment conditions. The analysis of real samples of laundry and dishwashing detergents was performed. The established high-performance liquid chromatography method was applied to evaluate the stacking CZE method, and compatible results were obtained.  相似文献   

17.
建立了消毒剂中三氯新的毛细管电泳分析方法。探讨了缓冲介质和电泳参数对三氯新测定的影响。以15mmol/LNa2HPO4(pH6.0)-乙腈(V(Na2HPO4)∶V(乙腈)=50∶50)为电泳缓冲液,三氯新在12kV电压下电泳,于254nm检测波长处测定,6min可以完成分析。本方法的检出限为0.04mg/L,线性范围0.04~2.00mg/mL(r=0.997),加标回收率在90.9%~108.2%范围内,测定值的相对标准偏差分别为峰高7.7%,迁移时间5.5%。将本法与高效液相色谱法进行比较,样品测定结果的相对误差小于10%。将所建立的方法已用于消毒剂样品中三氯新的测定。  相似文献   

18.
It is a frequent phenomenon in practice that a sample contains bulk levels of more than one coionic component that affect the stacking behavior of minor analytes and in this way also the sensitivity of the method. Here, attention is paid to stacking resulting from the presence of a macrocomponent of leading type that is deteriorated by the presence of another macrocomponent of like charge in the sample. Based on the isotachophoretic model of migration in the initial period of separation, a theoretical approach was elaborated both for strong and weak electrolytes which describes the separation process and finds the conditions that define whether transient isotachophoretic stacking of the analyte takes place or not. It is shown that the crucial parameter is the ratio of the concentrations of macrocomponents migrating in front and behind the analyte of interest. The destacking effect can also be expected when the coion of the background electrolyte is present in the sample. Rules how to cope with effects of destackers present in the sample are given. Theoretical considerations are illustrated by computer simulations and verified experimentally. Examples of antagonistic effects of macrocomponents are demonstrated for model serum samples.  相似文献   

19.
A method for separation and quantification of S-nitrosoglutathione in red cell extracts by capillary electrophoresis is reported. The method is based on the direct analysis of the metaphosphoric acid erythrocyte extract containing diethylenetriaminepentaacetic acid. Optimization of the method is briefly discussed. Best results in the shortest time were obtained at 25 degrees C, using a coated capillary, 7 kV applied voltage and phosphate sodium 40 mmol/L (pH 2.2) as running buffer. Reproducibility, detection limits, and recoveries of S-nitrosoglutathione analyses were checked. The results evidenced that S-nitrosoglutathione is formed in erythrocytes treated with S-nitrosocysteine, a transnitrosating agent. Under our experimental conditions, the contemporaneous detection and quantification of reduced and oxidized glutathione present in cell extract could also be performed.  相似文献   

20.
Determination of dyes in foodstuffs by capillary zone electrophoresis   总被引:1,自引:0,他引:1  
A rapid method based on capillary zone electrophoresis coupled with photodiode-array detection has been developed to determine the dyes Tartrazine E-102, Sunset Yellow FCF E110, Amaranth E-123, New Coccine E-124, Patent Blue V calcium salt E-131 and Allura Red AC E-129 in foodstuffs. Separation was done by using a Bare CElect-FS75 CE column, using a 10 mM phosphate buffer at pH 11.0. Hydrodynamic injections at 0.5 p.s.i. for 4 s (21 nl of sample) and 20 kV separation voltage were used. The quantitation limits for the six dyes ranged from 3 to 6 microg/ml. A linear relationship between 3 to 95 microg/ml, with correlation coefficient better than 0.995 was obtained. This method has been applied to the determination of the studied dyes in beverages, jellies and syrups.  相似文献   