1.
The most widely used ionization techniques in liquid chromatography-mass spectrometry (LC-MS) are electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). All three provide user friendly coupling of LC to MS. Achieving optimal LC-MS conditions is not always easy, however, owing to the complexity of ionization processes and the many parameters affecting mass spectrometric sensitivity and chromatographic performance. The selection of eluent composition requires particular attention since a solvent that is optimal for analyte ionization often does not provide acceptable retention and resolution in LC. Compromises must then be made between ionization and chromatographic separation efficiencies. The review presents an overview of studies concerning the effect of eluent composition on the ionization efficiency of ESI, APCI and APPI in LC-MS. Solvent characteristics are discussed in the light of ionization theories, and selected analytical applications are described. The aim is to provide practical background information for the development and optimization of LC-MS methods.  相似文献   

2.
Accurate measurement of estradiol (E2) is important in clinical diagnostics and research. High sensitivity methods are critical for specimens with E2 concentrations at low picomolar levels, such as serum of men, postmenopausal women and children. Achieving the required assay performance with LC–MS is challenging due to the non‐polar structure and low proton affinity of E2. Previous studies suggest that ionization has a major role for the performance of E2 measurement, but comparisons of different ionization techniques for the analysis of clinical samples are not available. In this study, female serum and endometrium tissue samples were used to compare electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) in both polarities. APPI was found to have the most potential for E2 analysis, with a quantification limit of 1 fmol on‐column. APCI and ESI could be employed in negative polarity, although being slightly less sensitive than APPI. In the presence of biological background, ESI was found to be highly susceptible to ion suppression, while APCI and APPI were largely unaffected by the sample matrix. Irrespective of the ionization technique, background interferences were observed when using the multiple reaction monitoring transitions commonly employed for E2 (m/z 271 > 159; m/z 255 > 145). These unidentified interferences were most severe in serum samples, varied in intensity between ionization techniques and required efficient chromatographic separation in order to achieve specificity for E2. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
Electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photo-ionization (APPI) are the most important techniques for the ionization of liquid samples. However, working under atmospheric pressure conditions, all these techniques involve some chemical rather than purely physical processes, and therefore, side reactions often yield to matrix-dependent ionization efficiencies. Here, a system is presented that combines both soft single-photon ionization (SPI) and hard 70 eV electron impact ionization (EI) of dissolved compounds under vacuum conditions. A quadrupole mass spectrometer was modified to enable direct EI, a technique developed by Cappiello et al. to obtain library-searchable EI mass spectra as well as soft SPI mass spectra of sample solutions. An electron beam-pumped rare gas excimer lamp working at 126 nm was used as well as a focusable vacuum UV light source for single-photon ionization. Both techniques, EI and SPI, were applied successfully for flow injection experiments providing library-matchable EI fragment mass spectra and soft SPI mass spectra, showing dominant signals for the molecular ion. Four model compounds were analyzed: hexadecane, propofol, chlorpropham, and eugenol, with detection limits in the picomolar range. This novel combination of EI and SPI promises great analytical benefits, thanks to the possibility of combining database alignment for EI data and molecular mass information provided by SPI. Possible applications for the presented ionization technology system are a matrix-effect-free detection and a rapid screening of different complex mixtures without time-consuming sample preparation or separation techniques (e.g., for analysis of reaction solutions in combinatorial chemistry) or a switchable hard (EI) and soft (SPI) MS method as detection step for liquid chromatography.
Figure
Scheme of the interface for introduction of liquid samples for vacuum photoionization/electron impact ionization MS  相似文献   

4.
The continuous development in analytical instrumentation has brought the newly developed Orbitrap‐based gas chromatography / mass spectrometry (GC/MS) instrument into the forefront for the analysis of complex mixtures such as crude oil. Traditional instrumentation usually requires a choice to be made between mass resolving power or an efficient chromatographic separation, which ideally enables the distinction of structural isomers that is not possible by mass spectrometry alone. Now, these features can be combined, thus enabling a deeper understanding of the constituents of volatile samples on a molecular level. Although electron ionization is the most popular ionization method employed in GC/MS analysis, the need for softer ionization methods has led to the utilization of atmospheric pressure ionization sources. The last arrival to this family is the atmospheric pressure photoionization (APPI), which was originally developed for liquid chromatography / mass spectrometry (LC/MS). With a newly developed commercial GC‐APPI interface, it is possible to extend the characterization of unknown compounds. Here, first results about the capabilities of the GC/MS instrument under high or low energy EI or APPI are reported on a volatile gas condensate. The use of different ionization energies helps matching the low abundant molecular ions to the structurally important fragment ions. A broad range of compounds from polar to medium polar were successfully detected and complementary information regarding the analyte was obtained.  相似文献   

5.
Atmospheric pressure (AP) GC/MS was first introduced by Horning et al. [E.C. Horning, M.G. Horning, D.I. Carroll, I. Dzidic, R.N. Stillwell, Anal. Chem. 45 (1973) 936] using 63Ni as a beta-emitter for ionization. Because, at the time special instrumentation was required, the technique was only applied with consistency to negative ion environmental studies where high sensitivity was required [T. Kinouchi, A.T.L. Miranda, L.G. Rushing, F.A. Beland, W.A. Korfmacher, J. High Resolut. Chromatogr., Chromatogr. Commun. 13 (1990) 281]. Currently, AP ion sources are commonly available on LC/MS instruments and recently a method was reported for converting an AP-LC/MS ion source to a combination AP-LC/MS:GC/MS source [C.N. McEwen, R.G. McKay, J. Am. Soc. Mass Spectrom. 16 (2005) 1730]. Here, we report the use of atmospheric pressure photoionization (APPI) with GC/MS and compare this to AP chemical ionization (APCI) GC/MS and electron ionization (EI) GC/MS. Using a nitrogen purge gas, we observe excellent chromatographic resolution and abundant molecular M+ and MH+ ions as well as structurally significant fragment ions. Comparison of a 9.8 eV UV lamp with a 10.6 eV lamp, as expected, shows that the higher energy lamp gives more universal ionization and more fragment ions than the lower energy lamp. While there are clear differences in the fragment ions observed by APPI-MS versus EI-MS, there are also similarities. As might be expected from the ionization mechanism, APPI ionization is similar to low energy EI. These odd electron fragment ions are useful in identifying unknown compounds by comparison to mass spectra in computer libraries.  相似文献   

6.
Various carotenoids were analyzed by ultra-high-pressure liquid chromatography with tandem mass spectrometry detection (UHPLC-MS/MS). Three different techniques to ionize the carotenoids were compared: electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI). For all of the carotenoids tested, it was possible to obtain characteristic transitions for their unequivocal identification using each ionization technique. APCI was shown to be a more powerful technique to ionize the carotenoids than ESI or APPI. Transitions to differentiate carotenoids that coelute were determined to distinguish antheraxanthin from astaxanthin and lutein from zeaxanthin. In addition, four dopants were evaluated to improve ionization and enhance the carotenoid signal strength in APPI. These dopants were acetone, toluene, anisole, and chlorobenzene. Carotenoids improved their response in almost all cases when a dopant was used. The use of dopants allowed the enhancement of the carotenoid signals strength up to 178-fold.  相似文献   

7.
Capillary electrophoresis/mass spectrometry (CE/MS) is predominantly carried out using electrospray ionization (ESI). Recently, atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) have become available for CE/MS. With the VUV lamp turned off, the APPI source may also be used for CE/MS by thermospray ionization (TSI). In the present study the suitability of ESI, APCI, APPI and TSI for drug impurity profiling by CE/MS in the positive ion mode is evaluated. The drugs carbachol, lidocaine and proguanil and their potential impurities were used as test compounds, representing different molecular polarities. A background electrolyte of 100 mM acetic acid (pH 4.5) provided baseline separation of nearly all impurities from the respective drugs. APPI yielded both even‐ and odd‐electron ions, whereas the other ionization techniques produced even‐electron ions only. In‐source fragmentation was more pronounced with APCI and APPI than with ESI and TSI, which was most obvious for proguanil and its impurities. In general, ESI and TSI appeared the most efficient ionization techniques for impurities that are charged in solution achieving detection limits of 100 ng/mL (full‐scan mode). APPI and APCI showed a lower efficiency, but allowed ionization of low and high polarity analytes, although quaternary ammonium compounds (e.g. carbachol) could not be detected. Largely neutral compounds, such as the lidocaine impurity 2,6‐dimethylaniline, could not be detected by TSI, and yielded similar detection limits (500 ng/mL) for ESI, APPI and APCI. In many cases, impurity detection at the 0.1% (w/w) level was possible when 1 mg/mL of parent drug was injected with at least one of the CE/MS systems. Overall, the tested CE/MS systems provide complementary information as illustrated by the detection and identification of an unknown impurity in carbachol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
系统地比较了3种常用的离子化技术电喷雾电离(ESI)、大气压化学电离(APCI)、大气压光致电离(APPI)对脂类化合物的离子化效率、检测灵敏度和覆盖范围,以探讨多重离子化液相色谱-质谱(LC-MS)方法在血清脂质组学研究中的适用性.血清样本经甲基叔丁基醚萃取后,采用Ascentiss Express C8 色谱柱(150 mm×2.1 mm, 2.7 μm)和二元线性梯度洗脱分离,流动相(A)为乙腈-水(3∶2, V/V, 含0.1%甲酸, 10 mmol/L甲酸铵),B为异丙醇-乙腈(9∶1, V/V, 含0.1%甲酸,10 mmol/L甲酸铵),分别采用ESI、APCI和APPI离子源正、负离子模式进行质谱检测.结果表明,ESI离子源对脂肪酸类、甘油脂类、甘油磷脂类化合物、鞘磷脂类化合物的离子化效率最高,对异戊烯醇脂类化合物的离子化效率与APPI离子源相当,APPI离子源对胆固醇(酯)类化合物的检测灵敏度最高,APCI离子源对各类化合物的检测灵敏度均低于ESI或APPI离子源;采用ESI和APPI离子源相结合的LC-MS脂质组学分析方法可以提高分析方法的整体灵敏度和血清中脂类信息检测的完整性.  相似文献   

9.
Although the coupling of GC/MS with atmospheric pressure ionization (API) has been reported in 1970s, the interest in coupling GC with atmospheric pressure ion source was expanded in the last decade. The demand of a “soft” ion source for preserving highly diagnostic molecular ion is desirable, as compared to the “hard” ionization technique such as electron ionization (EI) in traditional GC/MS, which fragments the molecule in an extensive way. These API sources include atmospheric pressure chemical ionization (APCI), atmospheric pressure photoionization (APPI), atmospheric pressure laser ionization (APLI), electrospray ionization (ESI) and low temperature plasma (LTP). This review discusses the advantages and drawbacks of this analytical platform. After an introduction in atmospheric pressure ionization the review gives an overview about the history and explains the mechanisms of various atmospheric pressure ionization techniques used in combination with GC such as APCI, APPI, APLI, ESI and LTP. Also new developments made in ion source geometry, ion source miniaturization and multipurpose ion source constructions are discussed and a comparison between GC-FID, GC-EI-MS and GC-API-MS shows the advantages and drawbacks of these techniques. The review ends with an overview of applications realized with GC-API-MS.  相似文献   

10.
A novel ion/molecule reaction was observed to occur under electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photo ionization (APPI) conditions, leading to dimerization of ionized 4‐(methyl mercapto)‐phenol followed by fast H· loss. The reaction is particularly favored during ESI, which suggests that this ion/molecule reaction can occur both in the solution inside the ESI‐charged droplets and in the gas‐phase environment of most other atmospheric pressure ionization techniques. The dimerization reaction is inherent to the electrolytic process during ESI, whereas it is more by ion/molecule chemistry in nature during APCI and APPI. From the tandem mass spectrometry (MS/MS) data, accurate mass measurements, hydrogen/deuterium (H/D) exchange experiments and density functional theory (DFT) calculations, two methyl sulfonium ions appear to be the most likely products of this electrophilic aromatic substitution reaction. The possible occurrence of this unexpected reaction complicates mass spectral data interpretation and can be misleading in terms of structural assignment as reported herein for 4‐(methyl mercapto)‐phenol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

11.
Analysis of 11 polybrominated diphenyl ethers (PBDEs), tetrabromobisphenol A bis 2,3-dibromopropylether (TBBPA-bis), tetrachlorobisphenol A (TCBPA), tetrabromobisphenol A (TBBPA) and hexabromocyclododecanes (HBCDs) was optimized by ultrahigh pressure liquid chromatography/tandem mass spectrometry (UPLC–MS/MS) operating in negative ion (NI) mode. Electrospray ionization (ESI), atmospheric pressure photoionization (APPI) and atmospheric pressure chemical ionization (APCI) sources were tested and for PBDEs APCI gave higher sensitivity than APPI while for TBBPA-bis APCI and APPI showed similar performance. ESI was the best option for TCBPA, TBBPA and HBCDs. Detection limits were between 20 and 59 fg for the compounds analyzed by ESI, 0.10 and 0.72 pg for PBDEs and 6 pg for TBBPA-bis. The matrix effect of sewage sludge extract was also tested showing negligible ion suppression for APCI and an increase of the background level of all investigated pollutants leading to a worsening of the limits of quantification by a factor between 1.2 and 3.3. The UPLC-APCI/MS/MS method for PBDEs, after pressurized liquid extraction (PLE), was validated by comparison with the concentration values from the NIST 1944 standard reference material. The advantages of the methods include low detection limits, PBDE congeners specificity using selected multiple reaction monitoring (MRM) transitions, and the absence of thermal degradation of higher PBDE congeners, especially BDE-209. The methods were applied for the determination of the above reported flame retardants in sewage sludge in order to get more information about the degradation on PBDEs (in particular BDE-209) during municipal wastewater treatments.  相似文献   

12.
The performance of the atmospheric pressure photoionization (APPI) technique was evaluated against five sets of standards and drug-like compounds and compared to atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI). The APPI technique was first used to analyze a set of 86 drug standards with diverse structures and polarities with a 100% detection rate. More detailed studies were then performed for another three sets of both drug standards and proprietary drug candidates. All 60 test compounds in these three sets were detected by APPI with an overall higher ionization efficiency than either APCI or ESI. Most of the non-polar compounds in these three sets were not ionized by APCI or ESI. Analysis of a final set of 201 Wyeth proprietary drug candidates by APPI, APCI and ESI provided an additional comparison of the ionization techniques. The detection rates in positive ion mode were 94% for APPI, 84% for APCI, and 84% for ESI. Combining positive and negative ion mode detection, APPI detected 98% of the compounds, while APCI and ESI detected 91%, respectively. This analysis shows that APPI is a valuable tool for day-to-day usage in a pharmaceutical company setting because it is able to successfully ionize more compounds, with greater structural diversity, than the other two ionization techniques. Consequently, APPI could be considered a more universal ionization method, and therefore has great potential in high-throughput drug discovery especially for open access liquid chromatography/mass spectrometry (LC/MS) applications.  相似文献   

13.
Electrospray ionization performs best with volatile buffers. However, generally the best separation performance for capillary electrophoresis (CE) is achieved with non‐volatile buffers. Hyphenation of CE with mass spectrometry (MS) utilizing atmospheric pressure photoionization (APPI) enables use of a wider range of separation buffers without compromising detection sensitivity. As APPI is considered to be mass flow sensitive, the use of a larger inner diameter separation capillary (75 µm) allows larger volumes to be injected, without decreased separation performance, thus providing improved sensitivity (approx. a factor of 10), compared to the use of a 25 µm capillary. However, nebulizing gas flow and position of capillary tip in the sprayer have to be carefully optimized to prevent excessive band broadening. Further improvement in sensitivity (approx. a factor of 2) was obtained by decreasing the distance between the sprayer and ionization region, indicating that a specially designed CE/APPI‐MS interface for low flow rates will be favourable. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
Hydroperoxides formed by autoxidation of common fragrance terpenes are strong allergens and known to cause allergic contact dermatitis (ACD), a common skin disease caused by low molecular weight chemicals. Until now, no suitable methods for chemical analyses of monoterpene hydroperoxides have been available. Their thermolability prohibits the use of gas chromatography and their low UV-absorption properties do not promote sensitive analytical methods by liquid chromatography based on UV detection. In our study, we have investigated different liquid chromatography/mass spectrometry (LC/MS) ionization techniques, electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photoionization (APPI), for detection of hydroperoxides from linalool and limonene.Flow injection analysis was used to evaluate the three different techniques to ionize the monoterpene hydroperoxides, linalool hydroperoxide and limonene hydroperoxide, by estimating the signal efficacy under experimental conditions for positive and negative ionization modes. The intensities for the species [M+H]+ and [M+H-H2O]+ in positive ionization mode and [M-H]- and [M-H-H2O]- in negative ionization mode were monitored. It was demonstrated that the mobile phase composition and instrumental parameters have major influences on the ionization efficiency of these compounds. ESI and APCI were both found to be appropriate as ionization techniques for detection of the two hydroperoxides. However, APPI was less suitable as ionization technique for the investigated hydroperoxides.  相似文献   

15.
The applicability of three different ionization techniques: atmospheric pressure photoionization (APPI), atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) was tested for the liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of five target pharmaceuticals (cyclophosphamide, methotrexate, bezafibrate, enalapril and orlistat) in wastewater samples. Performance was compared both by flow injection analysis (FIA) and on-column analysis in deionized water and wastewater samples. A column switching technique for the on-line extraction and analysis of water samples was used. For both FIA and on-column analysis, signal intensity and signal-to-noise (S/N) ratio of the target analytes in the three sources were studied. Limits of detection and matrix effects during the analysis of wastewater samples were also investigated. ESI generated significantly larger peak areas and higher S/N ratios than APCI and APPI in FIA and in on-column analysis. ESI was proved to be the most suitable ionization method as it enabled the detection of the five target compounds, whereas APCI and APPI ionized only four compounds.  相似文献   

16.
Liquid chromatography/atmospheric pressure photoionization tandem mass spectrometry (LC/APPI-MS/MS) was investigated as an instrumental method for the analysis of the halogenated norbornene flame retardants, Mirex, Dechloranes 602, 603, 604, and Dechlorane Plus (DP). The LC separation was optimized by screening a variety of stationary and mobile phases, resulting in a short LC separation time of 5 min. Different atmospheric pressure ionization approaches were examined including electrospray ionization, atmospheric pressure chemical ionization, and APPI, each with and without post-column addition. APPI without post-column addition was chosen for providing the best ionization response. The optimized LC/APPI-MS/MS approach resulted in instrument detection limits ranging between 25 and 50 pg. Good linearity was also achieved (up to 25.0 ng/μL; R >0.999). The method was applied to extracts of environmental samples including surface water, fish and sediments for screening purposes, and the results agreed well with those obtained by gas chromatography/mass spectrometry.  相似文献   

17.
A method using zirconia-based column high-performance liquid chromatography (HPLC) interfaced with an atmospheric pressure photoionization (APPI) source and a tandem mass spectrometer (MS/MS) was developed for the quantitative determination of new chemical entities in rat plasma in support of pharmacokinetics studies. The ionization suppression resulting from endogenous components of the biological matrices on the quantitative zirconia-based column HPLC/APPI-MS/MS method was investigated using the post-column infusion technique. The analytical results for 'rapid rat pharmacokinetics' for 12 drug discovery compounds, obtained by both silica-based phase (S-phase) and zirconia-based phase (Z-phase) chromatographic separation, are in good agreement in terms of accuracy. The application of a Z-phase column for high-temperature fast HPLC/MS/MS methods was explored to reduce the analysis time from 3 min to 30 s for column temperatures of 25-110 degrees C, respectively. The chromatographic retention times and peak responses of all analytes were found to be reproducible under high-temperature conditions following 100 continuous injections, with %CV less than 0.4 and 5, respectively.  相似文献   

18.
Atmospheric pressure photoionization (APPI) is a novel method of ionization in liquid chromatography/mass spectrometry (LC/MS). It was originally developed in order to broaden the range of LC/MS ionizable compounds towards less polar compounds that cannot be analyzed by electrospray (ESI) and atmospheric pressure chemical ionization (APCI). Studies done thus far have shown that non-polar compounds that earlier were not ionizable in LC/MS can indeed be ionized by the use of APPI. However, the best ionization efficiency for low polarity samples has been achieved with low proton affinity (PA) solvents that are not suitable in reversed-phase LC (RP-LC). Here it is demonstrated that the signals for analytes with low proton affinities in acetonitrile can be increased 100-fold by using anisole as the dopant for APPI, which takes the sensitivity to the same level achieved in the analysis of high PA analytes.  相似文献   

19.
LC-MS has become an invaluable technique for trace analysis of polar compounds in aqueous samples of the environment and in water treatment. LC-MS is of particular importance due to the impetus it has provided for research into the occurrence and fate of polar contaminants, and of their even more polar transformation products. Mass spectrometric detection and identification is most widely used in combination with sample preconcentration, chromatographic separation and atmospheric pressure ionization (API). The focus of the first part of this review is directed particularly toward instruments and method development with respect to their applications for detecting emerging contaminants, microorganisms and humic substances (HS). The current status and future perspectives of 1) mass analyzers, 2) ionization techniques to interface liquid chromatography (LC) with mass spectrometry (MS), 3) methods for preconcentration and separation with respect to their application for water analysis are discussed and examples of applications are given. Quadrupole and ion trap mass analyzers with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) are already applied in routine analysis. Time-of-flight (TOF) mass spectrometers are of particular interest for accurate mass measurements for identification of unknowns. For non-polar compounds, different ionization approaches have been described, such as atmospheric pressure photoionization (APPI), electrochemistry with ESI, or electron capture ionization with APCI. In sample preconcentration and separation, solid phase extraction (SPE) with different non-selective sorbent materials and HPLC on reversed-phase materials (RP-HPLC) play the dominant role. In addition, various on-line and miniaturized approaches for sample extraction and sample introduction into the MS have been used. Ion chromatography (IC), size-exclusion chromatography (SEC), and capillary electrophoresis (CE) are alternative separation techniques. Furthermore, the issues of compound identification, matrix effects on quantitation, development of mass spectral libraries and the topic of connecting analysis and toxicity bioassays are addressed.  相似文献   

20.
The high performance liquid chromatography (HPLC) separation methodology employed in the study of polyalkene additive compounds by atmospheric pressure ionization mass spectrometry (API-MS) was undertaken. Both atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) were examined. APPI (including dopant-assisted APPI) was found to be an inferior ionization technique to APCI in all cases. APCI ion responses were found to be highly dependent upon the organic solvent type used in the HPLC separations. Namely, employing a water/methanol gradient in place of a water/acetonitrile or a water/acetone gradient yielded improvements in analyte ion intensities between 2.3- and 52-fold for the liquid chromatography-mass spectrometry (LC-MS) experiments. Analyte and mobile phase solvent ionization energies were found to be only partially responsible, whereas mobile phase cluster formation and hydration was also implicated. Mobile phase component modification is demonstrated to be an important consideration when developing new, or modifying existing HPLC separations for use in LC-MS experiments in order to enhance analyte sensitivity for a wide variety of common polyalkene additives.  相似文献   