首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simple, precise, and accurate hydrophilic interaction liquid chromatographic (HILIC) method has been developed for the determination of five aromatic amines in environmental water samples. Chromatography was carried out on a bare silica column, using a mixture of acetonitrile and a buffer of NaH2PO4–H3PO4 (pH 1.5, containing 10 mM NaH2PO4) (85:15, v/v) as a mobile phase at a flow rate of 1 mL min−1. Aromatic amines were detected by UV absorbance at 254 nm. The linear range of amines was good (r2 > 0.998) and limit of detection (LOD) within 0.02–0.2 mg L−1 (S/N = 3). The retention mechanism for the analytes under the optimum conditions was determined to be a combination of adsorption, partition and ionic interactions. The proposed method was applied to the environmental water samples. Aromatic amines were isolated from aqueous samples using solid-phase extraction (SPE) with Oasis HLB cartridges. Recoveries of greater than 75% with precision (RSD) less than 12% were obtained at amine concentrations of 5–50 μg L−1 from 100 mL river water and influents from a wastewater treatment plant (WWTP). The present HILIC technique proved to be a viable method for the analysis of aromatic amines in the environmental water samples.  相似文献   

2.
应用亲水作用色谱(HILIC)对从市场上购买的鸡蛋和肉中的三聚氰胺及三聚氰胺降解产物三聚氰酸二酰胺进行了检测。采用的色谱柱为ZIC-HILIC柱,流动相为3 mmol/L磷酸二氢铵溶液(pH 6.9)-乙腈(20:80, v/v),流速为0.8 mL/min,检测波长为220 nm。在该体系下,三聚氰胺和三聚氰酸二酰胺的保留时间适中,与样品中的内源性物质有良好的分离。样品经0.1%磷酸提取,偏磷酸及乙腈沉淀蛋白质和糖类物质,以及P-SCX固相萃取柱净化。三聚氰胺和三聚氰酸二酰胺在0.4~40 mg/L范围内与峰面积呈良好的线性关系,样品定量限(按信噪比(S/N)不小于10计)为2 mg/kg,在2~10 mg/kg添加水平下的平均回收率为80%~105%,相对标准偏差小于10%。该方法具有良好的分离选择性,可用于鸡蛋和肉中三聚氰胺和三聚氰酸二酰胺的同时检测。  相似文献   

3.
Arai K  Mori M  Hironaga T  Itabashi H  Tanaka K 《色谱》2012,30(4):404-408
A combination of hydrophilic interaction chromatographic(HILIC) column and a weakly acidic cation-exchange resin(WCX) column was used for simultaneous separation of inorganic anions and cations by ion chromatography(IC).Firstly,the capability of HILIC column for the separation of analyte ions was evaluated under acidic eluent conditions.The columns used were SeQuant ZIC-HILIC(ZIC-HILIC) with a sulfobetaine-zwitterion stationary phase(ZIC-HILIC) and Acclaim HILIC-10 with a diol stationary phase(HILIC-10).When using tartaric acid as the eluent,the HILIC columns indicated strong retentions for anions,based on ion-pair interaction.Especially,HILIC-10 could strongly retain anions compared with ZIC-HILIC.The selectivity for analyte anions of HILIC-10 with 5 mmol/L tartaric acid eluent was in the order of I-> NO-3 > Br-> Cl-> H2PO-4.However,since HILIC-10 could not separate analyte cations,a WCX column(TSKgel Super IC-A/C) was connected after the HILIC column in series.The combination column system of HILIC and WCX columns could successfully separate ten ions(Na+,NH+4,K+,Mg2+,Ca2+,H2PO-4,Cl-,Br-,NO-3 and I-) with elution of 4 mmol/L tartaric acid plus 8 mmol/L 18-crown-6.The relative standard deviations(RSDs) of analyte ions by the system were in the ranges of 0.02%-0.05% in retention times and 0.18%-5.3% in peak areas through three-time successive injections.The limits of detection at signal-to-noise ratio of 3 were 0.24-0.30 μmol/L for the cations and 0.31-1.2 μmol/L for the anions.This system was applied for the simultaneous determination of the cations and the anions in a vegetable juice sample with satisfactory results.  相似文献   

4.
A chromatographic method utilizing hydrophilic interaction liquid chromatography was developed for the estimation of highly polar pharmaceutical adulterants in commercial slimming products. Five adulterants, phenylpropanolamine, salbutamol, phenformin, buformin, and metformin, were successfully separated on an XBridge? amide column (3.5 µm, 4.6?×?250 mm) using a mobile phase composed of acetonitrile/26.5 mM ammonium formate containing 0.1% formic acid (85:15) flowing at the rate of 0.8?mL/min. Wavelengths for monitoring the elution of these compounds were determined based on the wavelength of their absorption maxima (λmax?=?208, 226, and 236 nm). The developed method was validated for specificity, linearity, accuracy, precision, and robustness. Interassay comparison showed that the performance of the hydrophilic interaction liquid chromatography-based method was superior to that of the traditional reversed-phase liquid chromatography-based method. Therefore, the proposed method is useful to analyze highly polar pharmaceutical adulterants in slimming products.  相似文献   

5.
姜舸  沈爱金  郭志谋  李秀玲  梁鑫淼 《色谱》2015,33(9):929-933
糖类化合物因其极性强,在反相色谱模式下保留较弱,因此常用亲水作用色谱(HILIC)对其进行分离分析。本文以9种糖类化合物的混合物为研究对象,系统评价了其在Click TE-Cys亲水色谱柱上的保留行为,分别考察了流动相中有机相比例和盐浓度对其保留行为的影响。实验证明:9种糖类化合物按极性由小到大的顺序依次从Click TE-Cys色谱柱上被洗脱下来。随着有机相比例的增加,糖类化合物的保留增强;随着盐浓度的增加,除唾液酸外的糖类化合物的保留增强。用顶替-吸附液相相互作用模型模拟了糖类化合物在HILIC上的保留行为,采用保留方程ln k=a+blnCB+cCB描述HILIC的保留规律,对HILIC的保留值进行多元线性回归。结果表明糖类化合物在Click TE-Cys色谱柱上的保留行为符合HILIC的保留规律。  相似文献   

6.
A novel cationic hydrophilic interaction monolithic stationary phase based on the chemical modification of carboxymethyl chitosan (CMCH) to the monolithic silica skeleton using carbodiimide as an activation reagent was prepared for performing capillary liquid chromatography. The amino and hydroxy moieties of CMCH functioned as both the ion-exchange sites and polar providers. The performance of the column was studied by the separation of polar acidic compounds. The chitosan functionalized monolithic silica column showed good selectivity for nucleosides, nucleotides, aromatic acids and aliphatic acids. The mechanism for the separation of these compounds was also studied. The results showed that these compounds were separated primarily based on the hydrophilic interaction mechanism.  相似文献   

7.
娄旭华  左慧颖  王媛  赵文杰 《色谱》2020,38(4):430-437
通过亲核取代反应将聚乙烯马来酸酐键合到氨基硅胶表面,然后将残余的马来酸酐水解,制备了一种弱阳离子交换/亲水相互作用高效液相色谱固定相(Sil-PolyCOOH),通过固体核磁、ζ-电势及元素分析对固定相进行了表征。选取核苷和核酸碱为模型化合物,通过考察流动相组成,离子强度和pH等因素对溶质保留的影响,探讨了固定相的分离性能和保留机理,结果表明,该固定相的保留机理同时涉及亲水分配相互作用和多重主客体作用力。该固定相还对糖类、敌草快与百草枯等化合物具有良好的分离性能。上述研究结果表明该固定相在极性化合物的分离上具有良好的应用前景。  相似文献   

8.
The present study describes the first fully automated method based on on-line solid-phase extraction (SPE) coupled to hydrophilic interaction chromatography-electrospray-mass spectrometry (HILIC-(ESI)MS) to determine a group of polar drugs that includes illicit drugs (such as cocaine, morphine, codeine and metabolites) and pharmaceuticals in environmental water samples. The SPE was performed using a highly retentive polymeric sorbent. The HILIC separation was optimised and the initial high organic content of the chromatographic mobile phase, was also suitable for the proper on-line elution of the analytes retained in the SPE column and for enhancing the ESI ionisation efficiency. This method allows the loading of samples of up to 250ml of ultrapure water or 10ml of environmental water samples spiked at low ngl(-1) levels of the analytes. The method yields near 100% recoveries for all the analytes. The method was also validated with environmental water samples with linear ranges from 5 to 1000ngl(-1) and limits of detection ≤2ngl(-1) for most of the compounds.  相似文献   

9.
Regadenoson, the first selective adenosine A2A receptor agonist, is used to perform exercise stress test during radionuclide myocardial perfusion imaging. To detect the concentration of regadenoson in human plasma, a simple, fast, and sensitive tandem mass spectrometry method was established herein. Acetonitrile was used as a protein precipitation agent. Chromatographic separation was completed in 6.5 min using a BEH HILIC column (50 × 2.1 mm, 1.7 μm). The mobile phase consisted of 10 mmol/L ammonium acetate/acetonitrile (gradient elution). To quantify regadenoson and regadenoson-d3, an API 4000 mass spectrometry in multiple reaction monitoring mode with transitions of 391.3→259.2 and 394.3→262.2, respectively, was utilized. The calibration curve was linear in the range of 0.100–50.0 μg/L, and the intrabatch and interbatch precisions were <9.7% and <13.0%, respectively, and the accuracy was 2.0–6.9%. There was no apparent matrix effect for regadenoson or regadenoson-d3. The developed method was used to study the pharmacokinetic characteristics of regadenoson in healthy Chinese subjects.  相似文献   

10.
Ginsenosides have been widely conceded as having various biological activities and are considered to be the active ingredient of ginseng. Nowadays, preparative high‐performance liquid chromatography is considered to be a highly efficient method for ginseng saponins purification and preparation. However, in the process of practical application, due to the complex and varied composition of natural products and relatively simple pretreatment process, it is likely to block the chromatographic column and affect the separation efficiency and its service life. In this work, an orthogonal strategy was developed; in the first‐dimension separation, reverse‐phase macroporous resin was applied to remove impurities in ginseng crude extracts and classified ginseng extracts into protopanaxatriol and protopanaxadiol fractions. In the second‐dimension separation, the obtained fractions were further separated by a preparative hydrophilic column, and finally yielded 11 pure compounds. Eight of them identified as ginsenoside Rh1, Rg2, Rd, Rc, Rb2, Rb1, Rg1, and Re by standards comparison and electrospray ionization mass spectrometry. The purity of these ginsenosides was assessed by high‐performance liquid chromatography with UV detection.  相似文献   

11.
A rapid, sensitive and stability indicating high performance liquid chromatographic method was developed and validated for the analysis of dehydroepiandrosterone (DHEA) in pharmaceutical tablet formulation. The analysis was done on a Supelcosil C(18) column (25 cm x 4.6 mm i.d., 5 microm). The mobile phase consisted of methanol:sodium acetate buffer solution (5 g/L):acetic acid (500 mL/L), 57:42:1, v/v/v, adjusted to pH 5 at a flow rate of 1 mL/min. Detection was carried out at a wavelength of 258 nm. The polynomial regression data for the calibration curve showed good linear relationship in the concentration range of 0.2-1 mg/mL with r = 0.9996. The method was validated for precision, accuracy and recovery. The limit of detection was found to be 50 ng/ microL. The method was applied for the analysis of DHEA in its pharmaceutical tablet formulation. The effects of different buffers and alcohols on the retention of DHEA were studied and the role of acetic acid as an organic phase modifier was also investigated.  相似文献   

12.
An offline preparative two‐dimensional reversed‐phase liquid chromatography/hydrophilic interaction liquid chromatography coupled with hydrophilic interaction solid‐phase extraction method was developed for the preparative isolation of flavonoid glycosides from a crude sample of Sphaerophysa salsula . First, the non‐flavonoids were removed using an XAmide solid‐phase extraction cartridge. Based on the separation results of three different chromatographic stationary phases, the first‐dimensional preparation was performed on an XAqua C18 prep column, and 15 fractions were obtained from the 5.2 g target sample. Then, three representative fractions were selected for additional purification on an XAmide preparative column to further isolate the flavonoid glycosides. In all, eight flavonoid glycosides were isolated in purities over 97%. The results demonstrated that the two‐dimensional liquid chromatography method used in this study was effective for the preparative separation of flavonoid glycosides from Sphaerophysa salsula . Additionally, this method showed great potential for the separation of flavonoid glycosides from other plant materials.  相似文献   

13.
A monolithic capillary column with a mixed‐mode stationary phase of reversed‐phase/hydrophilic interaction chromatography was prepared for capillary liquid chromatography. The monolith was created by an in‐situ copolymerization of a homemade monomer N,N‐dimethyl‐N‐acryloxyundecyl‐N‐(3‐sulfopropyl) ammonium betaine and a crosslinker pentaerythritol triacrylate in a binary porogen agent consisting of methanol and isopropanol. The functional monomer was designed to have a highly polar zwitterionic sulfobetaine terminal group and a hydrophobic long alkyl chain moiety. The composition of the polymerization solution was systematically optimized to permit the best column performance. The columns were evaluated by using acidic, basic, polar neutral analytes, as well as a set of alkylbenzenes and Triton X100. Very good separations were obtained on the column with the mixed‐mode stationary phase. It was demonstrated that the mixed‐mode stationary phase displayed typic dual retention mechanisms of reversed‐phase/hydrophilic interaction liquid chromatography depending on the content of acetonitrile in the mobile phase. The method for column preparation is reproducible.  相似文献   

14.
A method for the preparation of poly(N-vinylpyrrolidone-co-pentaerythritol triacrylate copolymerization)-based monolithic capillary column was reported for the separation of polar small molecular weight compounds with nano-liquid chromatography in hydrophilic interaction chromatography mode. The monolithic columns were prepared by in situ copolymerization of N-vinylpyrrolidone and a cross-linker pentaerythritol triacrylate in a binary porogenic agent consisting of methanol and water. The composition of the polymerization solution was systematically optimized in terms of column permeability, theoretical plate number, asymmetric factor, and retention factor. A typical hydrophilic chromatography retention mechanism was observed with a mobile phase composed of a high content of organic solvent. The preparation method is simple and robust, the precursor N-vinylpyrrolidone is chemically stable, cheap, and easily available. The N-vinylpyrrolidone-based hydrophilic interaction chromatography stationary phase displays satisfactory separation selectivity for a range of polar test analytes, including benzoic acid derivatives, nucleosides, and phenols.  相似文献   

15.
A quick, simple, and reliable method was developed for the simultaneous determination of free and total choline and l‐ carnitine in infant formula employing a novel hydrophilic interaction liquid chromatography with tandem mass spectrometry method. Microwave‐assisted hydrolysis was used to shorten the hydrolysis time to only 15 min. A novel Click XIon zwitterionic stationary phase was chosen because it gave better retention, perfect resolution, and sharper symmetrical peaks compared to traditional columns. The matrix effect under different experimental conditions was evaluated by using the matrix effect factor, which employs stable isotopically labeled internal standards and is more appropriate for evaluating the matrix effect related to endogenous analytes. The accuracy and precision of the method were validated with certified reference materials. The fortified recovery values for choline and l‐ carnitine were between 85.0 and 104% with relevant standard deviations <5.0%. The established method was applied to the analysis of real infant formulas, demonstrating its applicability and feasibility.  相似文献   

16.
Surface‐bonded zwitterionic stationary phases have shown highlighted performances in separation of polar and hydrophilic compounds under hydrophilic interaction chromatography mode. So, it would be helpful to evaluate the characteristics of zwitterionic stationary phases with different arranged charged groups. The present work involved the preparation and comparison of three zwitterionic stationary phases. An imidazolium ionic liquid was designed and synthesized, and the cationic and anionic moieties respectively possessed positively charged imidazolium ring and negatively charged sulfonic groups. Then, the prepared ionic liquid, phosphorylcholine and an imidazolium‐based zwitterionic selector were bonded on the surface of silica to obtain three zwitterionic stationary phases. The selectivity properties were characterized and compared through the relative retention of selected solute pairs, and different kinds of hydrophilic solutes mixtures were used to evaluate the chromatographic performances. Moreover, the zwitterionic stationary phases were further characterized by the modified linear solvation energy relationship model to probe the multiple interactions. All the results indicated that the types and arrangement of charged groups in zwitterionic stationary phases mainly affect the retention and separation of ionic or ionizable compounds, and for interaction characteristics the contribution from n and π electrons and electrostatic interactions displayed certain differences.  相似文献   

17.
糖类化合物亲水作用色谱保留行为评价   总被引:2,自引:0,他引:2  
傅青  王军  梁图  徐晓勇  金郁 《色谱》2013,31(11):1051-1056
以糖类化合物为研究对象,系统评价了其在亲水模式下的色谱保留行为。分别考察了流动相、固定相和缓冲盐等对糖类化合物保留的影响,建立了糖类化合物在亲水模式下的保留方程。结果表明,糖类化合物随着流动相中乙腈比例的降低,保留时间减小;随着缓冲盐浓度的增加,保留时间增加;同时,糖类化合物的保留行为还会受到有机溶剂种类和固定相类型的影响;其保留行为可使用顶替吸附-液相相互作用模型定量描述。将该模型进一步用于实际样品中糖类化合物保留行为的预测,获得了较好的实验结果,预测保留时间与实测保留时间的相对误差小于0.3%。对糖类化合物亲水模式下的保留行为进行了系统的评价和定量描述,该研究结果将有助于糖类化合物亲水作用色谱分离方法的发展。  相似文献   

18.
A hydrophilic interaction liquid chromatographic method with tandem mass spectrometry for the determination of atenolol, a beta-blocking agent, in human plasma has been developed and validated over the curve range of 10--2000 ng/mL. The assay was based on protein precipitation followed by evaporation of the extraction solvent, reconstitution with acetonitrile, and chromatography on an Hypersil silica column (50 x 4.6 mm) using a low aqueous--high organic mobile phase. The mobile phase consists of 85% acetonitrile, 15% water, 0.5% acetic acid and 0.04% trifluoroacetic acid and runs isocratically at a flow rate of 2.0 mL/min. The column ef fluent was split so that 50% of it was transferred into the LC-MS/MS interface operated in positive electrospray ionization mode. The chromatographic run time was 2.0 min per injection. Atenolol and the internal standard, atenolol-d(7), showed a retention time of 1.0 min. The inter-day and intra-day precision and accuracy of the quality control samples were <5.3% relative standard deviation and <8.0% relative error, respectively. To explore the application of the current method for the analysis of other beta-blocking agents, propranolol and metoprolol were tested under the same chromatographic conditions with retention times of 0.68 and 0.75 min, respectively. The present method could be used for therapeutic drug monitoring, pharmacokinetic and drug--drug interaction studies of beta-blocking agents.  相似文献   

19.
A promising alternative to ion-chromatographic methods currently used for the direct determination of hydrazines is provided by hydrophilic interaction liquid chromatography (HILIC). In this work, we propose a method for the simultaneous determination of hydrazine, methylhydrazine and 1,1-dimethylhydrazine in natural waters and soils based on a combination of chromatographic separation on a zwitterionic sulfobetaine stationary phase (Nucleodur HILIC) in the HILIC mode with amperometric detection.

Effects of different factors on the retention of analytes were studied and the optimum conditions of analysis were found. We recommend a mixture of acetonitrile with an aqueous phosphate buffer solution of pH 2.5 (78:22 v/v) with an ionic strength of 20 mM as a mobile phase. Detection in the direct current mode was performed at a working electrode potential of 1.1 V.

The advantages of the method are the high efficiency of separation, rapidity, high sensitivity and a wide dynamic range of analyte concentrations, covering four orders of magnitude. The attained LOD values for analytes lie in the range 0.07–0.13 μg L–1, which is two orders of magnitude lower than those in currently used methods of ion chromatography with electrochemical and mass spectrometric detection.

The method was validated on samples of natural waters of different origin using the added–found technique. It was found that the error of analysis did not exceed 10% for river and ground waters and increased to 20–30% for peat bog surface waters.

The possibility of application of the developed method to the analysis of soils was shown on samples of peat bog soils selected at places of impact of the first steps of carrier rockets and polluted by rocket fuel based on 1,1-dimethylhydrazine.  相似文献   

20.
The present study described the preparation and application of a reversed-phase/zwitterionic/hydrophilic interaction liquid chromatography stationary phase, named as SIL-PS. The SIL-PS was prepared through a four-step reaction, chemical bonding, nucleophilic addition, SN1 substitution, and sulfonation on the silica matrix. It was featured with C12 alkyl chain, quaternary ammonium, tertiary amine, and sulfonate groups. After SIL-PS was packed into the stainless steel column (150?× 2.1 mm i.d.), chromatographic parameters, including acetonitrile content, pH, and ionic strength of the mobile phase, and the column temperature, were systematically investigated to study the retention mechanism. Electrostatic adsorptive/repulsive, partition, and hydrogen-bonding interactions were demonstrated to contribute to the retention. The stability of the SIL-PS was satisfactory, with relative standard deviations of retention factors of 1.93, 2.08, and 1.90% for loxoprofen, adenosine, and liquiritin, respectively. Additionally, to investigate the separation selectivity, the non-steroidal anti-inflammatory drugs, nucleobases/nucleotides, and alkaloids/glycosides were separated; the HPLC fingerprinting of the Cortex phellodendri extract was also conducted, and the separation performance was superior to that of the C18 column in terms of peak shape, resolution, and analytical time. The results revealed that the prepared SIL-PS possessed multifunctionalities for multiretention and could be promising for complicated samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号