首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary A systematic investigation of operational buffer systems, sample preparation and instrument parameters for achieving the best possible performance for determinating an homologous series of N-benzyl-N-alkyl-N,N-dimethylammonium chloride compounds by capillary zone electrophoresis with direct UV detection. The most effective separation was achieved within 3.5 min with the addition of acetonitrile (40%) in a phosphate buffer (20 mM pH 5.2) using a 40 cm fused-silica capillary operating at 25 KV and 20°C. Degassing of all electrolyte solutions and samples was very important. The linearity and repeatability for each compounds were satisfactory. To improve detection limits, on-column sample preconcentration, sample stacking, was investigated achieving a tenfold enrichment factor and quantitation limits about 10−7M.  相似文献   

2.
A large volume sample stacking procedure (LVSS) is developed here for metallothionein (MT) determinations in rabbit liver by using capillary electrophoresis with UV detection. A 10-time improvement in concentration-based LODs, when compared to the normal stacking mode (CE-UV analysis of samples solved in water), is achieved.The methodology is successfully applied to analysis of MTs in eel liver cytosolic extracts, preceded by an easy cleaning-up pre-treatment in order to eliminate the high salt content. Analysis of cytosol obtained from a group of eels previously exposed to Cd (induced group) resulted in several isoforms of MTs with differences in absorbance signal compared to a control group.  相似文献   

3.
Cao C  Zhang W  Fan L  Shao J  Li S 《Talanta》2011,84(3):651-658
The condensation of low abundance zwitterion substance, such as protein and peptide, has great significance to the study on proteomics. This paper develops the theory on design of online stacking conditions of zwitterion by a moving reaction boundary (MRB) in capillary electrophoresis (CE). This concerns the choice of running and sample buffers, velocity design of MRB, and salt effect on the stacking. The theoretical results unveil that: (1) the velocity of MRB formed with weak acidic buffer and strong alkali should be set between zero and the velocity of zwitterion in the alkali phase, or no stacking occurs; (2) if a strong alkali is used to prepare the sample, a much long front plug of strong base must be injected before the alkaline sample plug for complete stacking, whereas no such front plug is needed if a weak alkali with enough high concentration and pH value is used to prepare the sample buffer; (3) the existence of salt in sample matrix has a weak effect on the stacking of zwitterion if sample is prepared with weak alkaline buffer, while has a dramatic effect on the same stacking if with a strong base buffer. In addition, the concentration of weak alkali used for preparation of sample should be set at the point, at which the velocity of MRB is as much as possible close to that of negative zwitterion. The developed theory and its computation are quantitatively proved by the experiments of zwitterion stacking by the MRB as shown in the previous and the accompanying papers. The proposed theoretic results hold obvious significances on-column stacking of low abundance zwitterions, such as amino acid, or peptides or proteins, in CE.  相似文献   

4.
Zhang W  Fan L  Shao J  Li S  Li S  Cao C 《Talanta》2011,84(2):547-557
To demonstrate the theoretic method on the stacking of zwitterion with moving reaction boundary (MRB) in the accompanying paper, the relevant experiments were performed. The experimental results quantitatively show that (1) MRB velocity, including the comparisons between MRB and zwitterionic velocities, possesses key importance to the design of MRB stacking; (2) a much long front alkaline plug without sample should be injected before the sample injection for a complete stacking of zwitterion if sample buffer is prepared with strong base, conversely no such plug is needed if using a weak base as the sample buffer with proper concentration and pH value; (3) the presence of salt in MRB system holds dramatic effect on the MRB stacking if sample solution is a strong base, but has no effect if a weak alkali is used as sample solution; (4) all of the experiments of this paper, including the previous work, quantitatively manifest the theory and predictions shown in the accompanying paper. In addition, the so-called derivative MRB-induced re-stacking and transient FASI-induced re-stacking were also observed during the experiments, and the relevant mechanisms were briefly demonstrated with the results. The theory and its calculation procedures developed in the accompanying paper can be well used for the predictions to the MRB stacking of zwitterion in CE.  相似文献   

5.
Capillary zone electrophoresis (CZE) with UV detection was used to determine vanadium species. Nitrilotriacetic acid (NTA), hydroxyethylethylenediaminetriacetic acid (HEDTA), ethylenediaminetetraacetic acid (EDTA), diethylenetriaminepentaacetic acid (DTPA), ethylene glycol-bis(2-aminoethylether)-tetraacetic acid (EGTA) and 2,6-pyridinedicarboxylic acid (PDCA) were investigated to determine whether these ligands formed stable anionic complexes with vanadium. Of all the ligands studied HEDTA was the most suitable ligand because it gave the largest UV response with reasonable migration time. Electrospray mass spectrometry (ES-MS) was used to confirm the formation of [VO2(HEDTA)]2− and [VO(HEDTA)]1− in solution. An electrolyte containing 25 mM phosphate, 0.25 mM tetradecyltrimethylammonium bromide (TTAB) at pH 5.5 was optimum for the separation of these anionic vanadium complexes. Sample stacking techniques, including large-volume sample stacking (LVSS) and field-amplified sample injection (FASI), were tested to improve the sensitivity. Best sensitivity was obtained using FASI, with detection limits of 0.001 μM, equivalent to 0.4 μg L−1, for [VO2(HEDTA)]2− and 0.01 μM, equivalent to 3.4 μg L−1 for [VO(HEDTA)]1−. The utility of the method for the speciation of V(IV) and V(V) was demonstrated using ground water samples.  相似文献   

6.
The reason why a moving reaction boundary (MRB) can stack analyte in highly saline sample in capillary electrophoresis [C.X. Cao, Y.Z. He, M. Li, Y.T. Qian, S.L. Zhou, L. Yang, Q.S. Qu, Anal. Chem. 74 (2002) 4167] is still unclear. To illuminate the mechanism of such stacking, three MRBs formed by formic acid-NaOH buffer and sodium formate as well as 40, 80 and 120 mmol/L sodium chloride in matrixes were studied. The computation with MRB theory shows that sodium chloride in matrix has weak effect on the stacking efficiency, whether the concentration of sodium chloride is set at 40, or 80, or 120 mmol/L. The conclusion has been highly manifested by numerous experiments. Furthermore, the computer simulation and theoretical analyses depict that this kind of stacking is induced by the mechanism of MRB, rather than that of electrostacking or isotachophoresis (ITP) under the given electrolytic system. Finally, the application of the sample condensation was achieved for the stacking of analyte(s) in highly saline biological sample of skeletonema costarum’ culture with up to 527 mmol/L total salt and health human urine with 150-320 mmol/L inorganic ions (Cl, Na+, K+, PO43−, etc.). The results herein have a clear significance to the design on stacking of analyte in highly saline biological sample.  相似文献   

7.
电堆集富集非水毛细管电泳法测定麻黄碱   总被引:6,自引:0,他引:6  
以乙腈为非水介质,建立了电堆集富集非水毛细管电泳法测定麻黄碱的方法。运行缓冲溶液为50mmol LNH4Ac 30mL LHAc 900mL L乙腈,未涂层石英毛细管(75μmi.d×47cm,有效长度为40cm),压力进样20s,15kV恒压电泳(25℃),检测波长为200nm。在最优实验条件下,麻黄碱可在15min内与其它组分分离,麻黄碱的线性范围为2~14μg mL,检测限为42ng mL。  相似文献   

8.
Protein phosphorylation is one of the most important post-translational modifications (PTM), however, the detection of phosphorylation in proteins using mass spectrometry (MS) remains challenging. This is because many phosphorylated proteins are only present in low abundance, and the ionization of the phosphorylated components in MS is very inefficient compared to the non-phosphorylated counterparts. Recently, we have reported a selective injection technique that can separate phosphopeptides from non-phosphorylated peptides due to the differences in their isoelectric points (pI) [1]. Phosphorylated peptides from α-casein were clearly observed at low femtomole level using MALDI MS. In this work, further developments on selective injection of phosphopeptides are presented to enhance its capability in handling higher sample complexity. The approach is to integrate selective injection with a sample stacking technique used in capillary electrophoresis to enrich the sample concentration, followed by electrophoresis to fractionate the components in preparation for MALDI MS analysis. The effectiveness of the selective injection and stacking was evaluated quantitatively using a synthetic phosphopeptide as sample, with an enrichment factor of up to 600 being recorded. Next, a tryptic digest of α-casein was used to evaluate the separation and fractionation of peptides for MALDI MS analysis. The elution order of phosphopeptides essentially followed the order of decreasing number of phosphates on the peptides. Finally, to illustrate the applicability, the integrated procedure was applied to evaluate the phosphorylation of a highly phosphorylated protein, osteopontin. Up to 41 phosphopeptides were observed, which allowed us to examine the phosphorylation of all 29 possible sites previously reported [2]. A high level of heterogeneity in the phosphorylation of OPN was evident by the multiple-forms of variable phosphorylation detected for a large number of peptides.  相似文献   

9.
An on-line sample stacking method, namely field-amplified sample injection, has been developed for the separation and determination of carnosine, anserine, and homocarnosine by capillary electrophoresis. Using electrokinetic injection, about 130- to 160-fold improvement of sensitivity was achieved without loss of separation efficiency when compared to conventional sample injection. For conventional injection, the samples were dissolved in running buffer and then hydrodynamically injected for 10 s (3.45 kPa). Various parameters affecting separation and sample stacking were optimized. Under optimum conditions, linear responses were obtained over two orders of magnitude and the detection limits (defined as S/N = 3) of carnosine, anserine, and homocarnosine were 1.5 x 10(-8) to 1.6 x 10(-8) mol/L.  相似文献   

10.
Wang CC  Chiou SS  Wu SM 《Electrophoresis》2005,26(13):2637-2642
This study describes approaches for stacking a large volume of sample solutions containing a mixture of mercaptopurine monohydrate, 6-methylmercaptopurine, thioguanine, thioguanosine, and thioxanthine in capillary electrophoresis (CE). After filling the run buffer (60 mM borate buffer, pH 8.5), a large sample volume was loaded by hydrodynamic injection (2.5 psi, 99.9 s), followed by the removal of the large plug of sample matrix from the capillary using polarity switching (-15 kV). Monitoring the current and reversing the polarity when 95% of current recovered, the separation of anionic analytes was performed in a run buffer < 20 kV. Around 44- to 90-fold improvement of sensitivity for five analytes was achieved by large-volume stacking with polarity switching when compared with CE without stacking. This method was feasible for determination of the analytes spiked in plasma. Removing most of electrolytes from plasma is a key step for performing large-volume sample stacking. Solid-phase extraction was used for pretreatment of biological samples. To our knowledge, this study is one of few applications showing the possibilities of this stacking procedure to analyze biological samples by large-volume sample stacking with polarity switching (LVSSPS) in CE.  相似文献   

11.
A simple capillary electrophoresis method was developed to separate and quantify methylmercury, ethylmercury, and phenylmercury with the enhancement of pre-column derivatization and on-line stacking.  相似文献   

12.
Fan L  Cheng Y  Li Y  Chen H  Chen X  Hu Z 《Electrophoresis》2005,26(22):4345-4354
A simple, effective, and continuous online concentration method for the sensitive detection of alkaloids applying CE-flow injection analysis with head-column field-amplified sample stacking was developed. A series of samples was continuously introduced into the capillary by electrokinetic means without interrupting the high voltage. A short water plug was introduced by the EOF at the capillary inlet end prior to sample introduction. Under optimum conditions, 15-fold improvement in concentration sensitivity was achieved, giving an LOD of about 0.67 and 0.73 microg/mL for ephedrine (E) and pseudoephedrine (PE), respectively. The separation could be achieved within 4 min and sample throughput rate could reach up to 7/h. The repeatability (defined as RSD) was 3.62, 1.51% with peak area evaluation and 1.30, 2.58% with peak height evaluation for E and PE, respectively. This method has been successfully applied to the analysis of commercial pharmaceutical preparations containing E and PE, and the recoveries were 92.3-102.4%.  相似文献   

13.
Micelle to solvent stacking (MSS) is a new on-line sample concentration technique for charged analytes in capillary zone electrophoresis (CZE). Sample concentration in MSS mainly relies on the reversal in the effective electrophoretic mobility of the analyte at the boundary zone between the sample solution (S) and CZE background solution (BGS) inside the capillary. The basic condition for MSS is that the S is prepared in a matrix that contains an additive (i.e., micelles) which interacts with and has an opposite charge compared to the analytes. In addition, the BGS must contain a sufficient percentage of organic solvent. MSS was first reported for organic cations using anionic dodecyl sulfate micelles as additive in the S and methanol or acetonitrile as organic solvent in the BGS. Here, theoretical and experimental studies on MSS are described for organic anions using cationic cetyltrimethyl ammonium micelles as additive in the S and methanol as organic solvent in the BGS. Up to an order of magnitude improvement in concentration sensitivity was obtained for the test hypolipidaemic drugs using MSS in CZE with UV detection. The optimized method was also evaluated to the analysis of a spiked wastewater sample that was subjected to a simple extraction step.  相似文献   

14.
建立了毛细管区带电泳(CZE)中场放大样品堆积(FASS)技术分析尿液中苯丙胺类毒品的方法。采用体积分数30%甲醇的100 mmol/L磷酸盐(pH 3)为分离缓冲液,利用缓冲体系与样品溶液体系电导率的差异,在毛细管中浓缩样品组分,对苯丙胺、甲基苯丙胺、3,4-(亚甲二氧基)苯丙胺(MDA)、3,4-(亚甲二氧基)甲基苯丙胺(MDMA)4种毒品进行了分离和定量测定,与常规毛细管区带电泳比较,检测灵敏度提高约2000倍。采用利多卡因为内标,对添加上述4种毒品的尿液进行提取和测定,分析的相对标准偏差在15%范围之内,可检测到的上述毒品质量浓度为0.002μg/mL,相对回收率在70%~120%内。该方法可用于生物检材中苯丙胺类毒品的检测。  相似文献   

15.
柱头场放大样品富集技术测定镍   总被引:1,自引:0,他引:1  
利用毛细管电泳在线化学发光检测技术,研究了镍离子场放大样品富集过程。结果表明,利用该技术可使灵敏度显著改善,浓缩因子达5 8×104,镍离子检出限为1 2×10-10mol/L。预进一段水柱可使检出限达到7 0×10-11mol L。还考察了进样方式、样品基体浓度、进样时间、进样电压对检测灵敏度的影响。  相似文献   

16.
The performance of an integrated capillary electrophoresis system with a novel split-flow sample injection mechanism and special high sensitivity UV absorbance detector is described. Sample introduction into the capillary is accomplished with a standard HPLC-type microliter syringe. The injected sample is divided proportionally between the separation capillary and an adjustable splitvent. The volume of sample introduced into the capillary can be manipulated by varying the length or the i.d. of the splitvent tubing; or the volume of sample injected. Data are presented showing reproducibility of retention time, peak height, and peak area; minimum detectability; and operation at short UV wavelengths.  相似文献   

17.
The main aim of this work was to demonstrate the applicability of capillary zone electrophoresis in combination with field enhanced sample stacking in targeted metabolome analyses of adenine nucleotides – AMP, ADP, ATP, coenzymes NAD+, NADP+ and their reduced forms in Paracoccus denitrificans. Sodium carbonate/hydrogencarbonate buffer (100 mM, pH 9.6) with the addition of β‐CD at a concentration of 10 mM was found to be an effective BGE for their separation within 20 min. Besides this, special attention was paid to the development of the procedure for the extraction of specific metabolites from the bacterium P. denitrificans. This procedure was not only optimised to achieve the highest metabolite yields but also to obtain a sample that was fully compatible with the online preconcetration strategy used. The developed methodology was finally applied in a study of the bacterium P. denitrificans at various stages of the active respiratory chain.  相似文献   

18.
In the present study, field-amplified sample stacking injection using the electroosmotic flow pump (FAEP) was developed for the capillary electrophoretic separation of the four nerve agent degradation products methylphosphonic acid (MPA), ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA) and cyclohexyl methylphosphonic acid (CMPA). Coupled to contactless conductivity detection, direct quantification of these non-UV active compounds could be achieved. Sensitivity enhancement of up to 500 to 750-fold could be obtained. The newly established approach was applied to the determination of the analytes in river water and aqueous extracts of soil. Detection limits of 0.5, 0.7, 1.4 and 2.7 ng/mL were obtained for MPA, EMPA, IMPA and CMPA, respectively, in river water and 0.09, 0.14, 0.44 and 0.22 μg/g, respectively, in soil.  相似文献   

19.
《Electrophoresis》2018,39(16):2117-2124
Goji berry, fruits of the plant Lycium barbarum L., has long been used as traditional medicine and functional food in China. In this work, a simple and easy‐operation on‐line concentration capillary electrophoresis (CE) for detection flavonoids in goji berry was developed by coupling of field amplified sample stacking (FASS) with an electroosmotic (EOF) pump driving water removal process. Due to the EOF pump and electrokinetic injection showing different influence on the concentration, the analytes injection condition should be systemically studied. Thereafter, the verification of the analytes injection conditions was achieved using response surface experimental design. Under the optimum conditions, 86–271 folds sensitivity enhancement upon normal capillary zone electrophoresis (CZE, 50 mbar × 5 s) were achieved for six flavonoids, and the detection limits ranged from 0.35 to 1.82 ng/mL; the LOQ ranged from 1.20 to 6.01 ng/mL. Eventually, the proposed method was applied to detect flavonoids in 30 goji berry samples from different habitats of China; and the results indicated that the flavonoids were rich in the eluent of 30–60% methanol, which provided a reference for extraction of goji berry flavonoids.  相似文献   

20.
Large volume stacking using the electroosmotic flow (EOF) pump (LVSEP) in capillary electrophoresis under a reverse potential is a convenient and straightforward approach for on-line concentration of dilute anionic sample solutions. LVSEP achieves automatic sample matrix removal and subsequent separation without intermediate polarity switching nor complicated instrumental setup. Since anionic analytes should move against the EOF in LVSEP, EOF needs to be suppressed. We extended the range of LVSEP up to pH 11 using various EOF suppression methods, such as dynamic coating by polymer pretreatment and permanent coating. Weakly acidic organic compounds (pKa<5.2), chlorinated phenols (pKa=7-9), and aromatic amino acids (pKa2∼9.3) were concentrated and separated. By hydrodynamically filling the whole capillary of 27 cm long with the sample solution, fast and reliable injection was achieved and sensitivity enhancement factors as large as 170 were readily obtained in less than 8 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号