 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new, variable-temperature mass spectrometer system is described. By applying polyimide heating tape to the end-cap electrodes of a Bruker (Bremen, Germany) Esquire ion trap, it is possible to vary the effective temperature of the system between 40 and 100°C. The modification does not impact the operation of the ion trap and the heater can be used for extended periods without degradation of the system. The accuracy of the ion trap temperatures was assessed by examining two gas-phase equilibrium processes with known thermochemistry. In each case, the variable-temperature ion trap provided data that were in good accord with literature data, indicating the effective temperature in the ion trap environment was being successfully modulated by the changes in the set-point temperatures on the end-cap electrodes. The new design offers a convenient and effective way to convert commercial ion trap mass spectrometers into variable-temperature instruments.
Graphical Abstract ?
  相似文献   

2.
Examination of the collisional cooling effect of the buffer gases on ion trapping and detection in an ion trap mass spectrometer has been undertaken by the SIMION 3D program. Computation for the kinetic energy of ions under various conditions was used to account for the effects of collisional cooling of ions. Several parameters that may affect the collisional cooling effects of ions are evaluated including the existence and the variation of pressure of the buffer gas; the temperature of the ion trap; the size of the inner radius of the ion trap electrodes; the mass to charge ratio of ions; the alternative buffer gases and the qz. values which establish the ion trap trapping environment.  相似文献   

3.
The extent of internal energy deposition into ions upon storage, radial ejection, and detection using a linear quadrupole ion trap mass spectrometer is investigated as a function of ion size (m/z 59 to 810) using seven ion-molecule thermometer reactions that have well characterized reaction entropies and enthalpies. The average effective temperatures of the reactants and products of the ion-molecule reactions, which were obtained from ion-molecule equilibrium measurements, range from 295 to 350 K and do not depend significantly on the number of trapped ions, m/z value, ion trap q z value, reaction enthalpy/entropy, or the number of vibrational degrees of freedom for the seven reactions investigated. The average of the effective temperature values obtained for all seven thermometer reactions is 318?±?23 K, which indicates that linear quadrupole ion trap mass spectrometers can be used to study the structure(s) and reactivity of ions at near ambient temperature.
Figure
?  相似文献   

4.
UV–vis photodissociation action spectroscopy is becoming increasingly prevalent because of advances in, and commercial availability of, ion trapping technologies and tunable laser sources. This study outlines in detail an instrumental arrangement, combining a commercial ion-trap mass spectrometer and tunable nanosecond pulsed laser source, for performing fully automated photodissociation action spectroscopy on gas-phase ions. The components of the instrumentation are outlined, including the optical and electronic interfacing, in addition to the control software for automating the experiment and performing online analysis of the spectra. To demonstrate the utility of this ensemble, the photodissociation action spectra of 4-chloroanilinium, 4-bromoanilinium, and 4-iodoanilinium cations are presented and discussed. Multiple photoproducts are detected in each case and the photoproduct yields are followed as a function of laser wavelength. It is shown that the wavelength-dependent partitioning of the halide loss, H loss, and NH3 loss channels can be broadly rationalized in terms of the relative carbon-halide bond dissociation energies and processes of energy redistribution. The photodissociation action spectrum of (phenyl)Ag2 + is compared with a literature spectrum as a further benchmark.
Figure
?  相似文献   

5.
Modifications to a Paul-type quadrupole ion trap mass spectrometer providing optical access to the trapped ion cloud as well as hardware and software for coupling to a table-top IR optical parametric oscillator laser (OPO) are detailed. Critical experimental parameters for infrared multiple photon dissociation (IRMPD) on this instrument are characterized. IRMPD action spectra, collected in the hydrogen-stretching region with this instrument, complemented by spectra in the IR fingerprint region acquired at the FELIX facility, are employed to characterize the structures of the protonated forms of 2-thiouridine, [s2Urd+H]+, and 4-thiouridine, [s4Urd+H]+. The measured spectra are compared with predicted linear IR spectra calculated at the B3LYP/6-311+G(d,p) level of theory to determine the conformers populated in the experiments. This comparison indicates that thiation at the 2- or 4-positions shifts the protonation preference between the 2,4-H tautomer and 4-protonation in opposite directions versus canonical uridine, which displays a roughly equal preference for the 2,4-H tautomer and O4 protonation. As found for canonical uridine, protonation leads to a mixture of conformers exhibiting C2′-endo and C3′-endo sugar puckering with an anti nucleobase orientation being populated for both 2- and 4-thiated uridine.
Graphical Abstract ?
  相似文献   

6.
Conventionally, quadrupole ion trap mass spectrometers eject ions of different mass-to-charge ratio (m/z) in a sequential fashion by performing a scan of the rf trapping voltage amplitude. Due to the inherent sparsity of most mass spectra, the detector measures no signal for much of the scan time. By exploiting this sparsity property, we propose a new compressive and multiplexed mass analysis approach—multi Resonant Frequency Excitation (mRFE) ejection. This new approach divides the mass spectrum into several mass subranges and detects all the subrange spectra in parallel for increased mass analysis speed. Mathematical estimation of standard mass spectrum is demonstrated while statistical classification on the parallel measurements remains viable because of the sparse nature of the mass spectra. This method can reduce mass analysis time by a factor of 3–6 and increase system duty cycle by 2×. The combination of reduced analysis time and accurate compound classification is demonstrated in a commercial quadrupole ion trap (QIT) system.
Figure
?  相似文献   

7.
The gas-phase fluorescence excitation, emission and photodissociation characteristics of three xanthene dyes (rhodamine 575, rhodamine 590, and rhodamine 6G) have been investigated in a quadrupole ion trap mass spectrometer. Measured gas-phase excitation and dispersed emission spectra are compared with solution-phase spectra and computations. The excitation and emission maxima for all three protonated dyes lie at higher energy in the gas phase than in solution. The measured Stokes shifts are significantly smaller for the isolated gaseous ions than the solvated ions. Laser power-dependence measurements indicate that absorption of multiple photons is required for photodissociation. Redshifts and broadening of the dispersed fluorescence spectra at high excitation laser power provide evidence of gradual heating of the ion population, pointing to a mechanism of sequential multiple-photon activation through absorption/emission cycling. The relative brightness in the gas phase follows the order R575(1.00) < R590(1.15) < R6G(1.29). Fluorescence emission from several mass-selected product ions has been measured.  相似文献   

8.
利用数字离子阱技术进行样品的快速质量分析.在样品离子被引入离子阱的过程中,同时扫描数字射频工作电压的频率和离子共振偶极电压的频率,使得离子在进入离子阱质量分析器后,立即被相应的共振偶极电压所共振激发而逐出离子阱,并被离子探测器测量到.本方法相较于传统离子阱分析过程省去了离子引入、离子冷却和离子清空3个阶段,减少了约3/4的实验分析时间.通过对扫描速度、离子门电压参数的优化,数字束缚射频频率从1000~ 400 kHz线性扫描,扫描速度为2385 Th/s,离子门电压为9V,对利血平(m/z 609),精氨酸(m/z 174)等样品的进行测试,离子信号强度达到最优.结果表明,利用本方法可以获得与离子阱质量分析传统方法相同的质谱结果.  相似文献   

9.
气相色谱离子阱质谱联用仪(GC-ITMS)广泛地应用于药物分析、环境分析、农药检测和食品分析、有机化学品分析、毒品分析以及医学和生物分析等领域。离子阱质谱作为色谱的检测器,决定了色质联用仪的分析性能,包括检出限、分辨率。离子阱质量分析器从传统的双曲型3D离子阱发展到2D线性离子阱,质量歧视效应得到了极大的改善,灵敏度得到了提高。矩形离子阱作为线性离子阱,结构简单,加工和装配容易,因此应用到GCMS系统中将具有非常大的优势。介绍了矩形离子阱质谱仪的设计方案、仪器整机的性能测试、质量分辨和质量歧视效应分析,与Agilent6890组成GCMS联用仪,对实际样品进行了分析。  相似文献   

10.
将数字化离子阱技术和矩形离子阱(RIT)技术相结合,建立了数字化矩形离子阱质谱仪.此技术和装置既具有数字化电源的结构简单、输出稳定和易精确控制等特点,又结合了矩形离子阱的高离子存储效率、结构简单以及加工和装配容易等优点.构建了基于电喷雾(ESI)电离源的数字化矩形离子阱质谱仪系统,并使用Fenfluramine和PPG2000分别对此系统的质量分辨率和质量范围进行了测试.研究结果表明:一个用印刷线路板(PCB)制作的简单矩形离子阱,在200 V(半峰值)的数字束缚电压的驱动下,获得了大于500的质量分辨率和超过2600 Th的质量范围.实验证明,数字化离子阱技术的应用可以显著提高矩形离子阱的性能,特别是质量范围等关键的质谱仪指标.  相似文献   

11.
We adopt an orthogonal wavelet packet decomposition (OWPD) filtering approach to cancel harmonic interference noises arising from an AC power source in time domain and remove the resulting rf voltage interference noise from the mass spectra acquired by using a charge detection frequency-scan quadrupole ion trap mass spectrometer. With the use of a phase lock resampling technique, the transform coefficients of the rf interference in signals become a constant, exhibiting a shift of the baseline in different rf phases. The rf interference is therefore removable by shifting the baselines back to zero in OWPD coefficients. The approach successfully reduces the time-domain background noise from 1367 electrons (rms) to 408 electrons (rms) (an improvement of 70?%) and removes the high frequency noise components in the charge detection ion trap mass spectrometry. Unlike other smoothing or averaging methods commonly used in the mass-to-charge (m/Ze) domain, our approach does not cause any distortion of original signals.  相似文献   

12.
Positive-mode atmospheric pressure chemical ionization tandem mass spectrometry (APCI-MS n ) was tested for the differentiation of regioisomeric aromatic ketocarboxylic acids. Each analyte forms exclusively an abundant protonated molecule upon ionization via positive-mode APCI in a commercial linear quadrupole ion trap (LQIT) mass spectrometer. Energy-resolved collision-activated dissociation (CAD) experiments carried out on the protonated analytes revealed fragmentation patterns that varied based on the location of the functional groups. Unambiguous differentiation between the regioisomers was achieved in each case by observing different fragmentation patterns, different relative abundances of ion-molecule reaction products, or different relative abundances of fragment ions formed at different collision energies. The mechanisms of some of the reactions were examined by H/D exchange reactions and molecular orbital calculations.  相似文献   

13.
Collisional cooling rates of infrared excited ions are measured in a quadrupole ion trap (QIT) mass spectrometer at different combinations of temperature and pressure. Measurements are carried out by monitoring fragmentation efficiency of leucine enkephalin as a function of irradiation time by an infrared laser after a short excitation and incrementally increasing cooling periods. Cooling rates are observed to be directly related to bath gas pressure and inversely related to bath gas temperature. The cooling rate at typical ion trap operating pressure (1 mTorr) and temperature (room T) is faster than can be measured. At elevated temperature and the lowest pressure used for the studies, the rate of collisional cooling becomes negligible compared to the rate of radiative cooling.  相似文献   

14.
The effects on ion motion caused by the application of a resonance AC dipole voltage to the end-cap electrodes of the quadrupole ion trap are described. An excimer laser is used to photodissociate benzoyl ions, and its triggering is phase locked to the AC voltage to follow the motion of the ion cloud as a function of the phase angle of the AC signal. Resonantly excited ions maintain a coherent motion in the presence of He buffer gas, which dissipates energy from the ions via collisions. Maximum ion displacements, which depend upon the potential well depth (q z value), occur twice each AC cycle. Axial components of ion velocities are determined by differentiating the displacements of the distributions with respect to time. The experimental data show that these velocities are maximized when the ion cloud passes through zero axial displacement, and they compare favorably with results calculated using a simple harmonic oscillator model. Axial components of ion kinetic energies are low (<5 eV) under the chosen experimental conditions. At low values of q2 (≈ 0.2), the width of the ion distribution increases as the ion cloud approaches the center of the trap and decreases as it approaches the end-cap electrodes. This effect is created by compaction of the ion trajectories when ion velocities are decreased,  相似文献   

15.
The fragmentation patterns obtained by ultraviolet photodissociation (UVPD) and collision-induced dissociation (CID) in a quadrupole ion trap mass spectrometer were compared for peptides modified at their C-termini and at acidic amino acids. Attachment of Alexa Fluor 350 or 7-amino-4-methyl-coumarin chromophores at the C-terminal and acidic residues enhances the UV absorptivity of the peptides and all fragment ions that retain the chromophore, such as the y ions that contain the chromophore-modified C-terminus. Whereas CID results in the formation of the typical array of mainly y-type and a/b-type fragment ions, UVPD produces predominantly a/b-type ions with greatly reduced abundances of y ions. Immonium ions, mostly ones from aromatic or basic amino acids, are also observed in the low m/z range upon UVPD. UVPD of peptides containing two chromophore moieties (with one at the C-terminus and another at an acidic residue) results in even more efficient photodissociation at the expense of the annihilation of almost all diagnostic b and y ions containing the chromophore.  相似文献   

16.
基于飞行时间质谱技术、线性离子阱技术、大气压电离源等核心技术,自制了一款台式高分辨线性离子阱飞行时间联用质谱仪器(LIT-TOF MS)。以电喷雾离子源对仪器性能进行表征:LIT-TOF MS的质量分辨率超过12 000(利血平m/z 609),质量范围达到33~1 922 amu,灵敏度为1μg/L;能够实现MS3的三级质谱分析效果。对氨基酸进行了定性及定量的初步应用分析,结果表明:LIT-TOF MS可为代谢组学研究中实时、在线、高通量测定生物复杂样品中氨基酸的含量及其变化提供一定依据。该仪器能与多种常压电离技术联用,有望用于药品、环境、食品等领域。  相似文献   

17.
Implementation of orthogonal double resonance precursor and neutral loss scans on the Mini 12 miniature rectilinear ion trap mass spectrometer is described, and performance is compared to that of a commercial Thermo linear trap quadropole (LTQ) linear ion trap. The ac frequency scan version of the technique at constant rf voltage is used here because it is operationally much simpler to implement. Remarkably, the Mini 12 shows up to two orders of magnitude higher sensitivity compared to that of the LTQ. Resolution on the LTQ is better than unit at scan speeds of ~?400 Th/s, whereas peak widths on the Mini 12, on average, range from 0.5 to 2.0 Th full width at half maximum and depend heavily on the precursor ion Mathieu q parameter as well as the pump down time that precedes the mass scan. Both sensitivity and resolution are maximized under higher pressure conditions (short pump down time) on the Mini 12. The effective mass range of the product ion ejection waveform was found to be 5.8 Th on the Mini 12 in the precursor ion scan mode vs. that of 3.9 Th on the LTQ. In the neutral loss scan mode, the product ion selectivity was between 8 and 11 Th on the Mini 12 and between 7 and 8 Th on the LTQ. The effects of nonlinear resonance lines on the Mini 12 were also explored.
Graphical Abstract ?
  相似文献   

18.
Collision cross sections (CCSs) were determined from the frequency-domain linewidths in a Fourier transform electrostatic linear ion trap. With use of an ultrahigh-vacuum precision leak valve and nitrogen gas, transients were recorded as the background pressure in the mass analyzer chamber was varied between 4× 10-8 and 7 × 10-7 Torr. The energetic hard-sphere ion–neutral collision model, described by Xu and coworkers, was used to relate the recorded image charge to the CCS of the molecule. In lieu of our monoisotopically isolating the mass of interest, the known relative isotopic abundances were programmed into the Lorentzian fitting algorithm such that the linewidth was extracted from a sum of Lorentzians. Although this works only if the isotopic distribution is known a priori, it prevents ion loss, preserves the high signal-to-noise ratio, and minimizes the experimental error on our homebuilt instrument. Six tetraalkylammonium cations were used to correlate the CCS measured in the electrostatic linear ion trap with that measured by drift-tube ion mobility spectrometry, for which there was an excellent correlation (R 2 ≈ 0.9999). Although the absolute CCSs derived with our method differ from those reported, the extracted linear correlation can be used to correct the raw CCS. With use of [angiotensin II]2+ and reserpine, the corrected CCSs (334.9 ± 2.1 and 250.1 ± 0.5, respectively) were in good agreement with the reported ion mobility spectrometry CCSs (335 and 254.3, respectively). With sufficient signal-to-noise ratio, the CCSs determined are reproducible to within a fraction of a percent, comparable to the uncertainties reported on dedicated ion mobility instruments.
Graphical Abstract ?
  相似文献   

19.
A rapid,sensitive,and accurate method based on LC/MS/MS was developed and validated for the determination of domperidone in human plasma.Domperidone and internal standard,tramadol,were extracted from plasma with diethyl ether-dichloromethane(60∶40,volume ratio)and separated by reversed-phase HPLC with methanol-water-ammonia solution(80∶20∶0.2,volume ratio)as the mobile phase.Detection was carried out via multiple-reaction monitoring(MRM)on a Q-trapTM LC/MS/MS system(Q-trapTM).The assay result was linear over a concentration range of 0.1-30 ng/mL with a limit of quantitation(LOQ)of 0.1 ng/mL.The inter-and intra-day precision levels were within 7.52% and 12.9%,respectively,whereas the accuracy was within a range of 87.3%-114%.This method has been successfully applied to evaluate the pharmacokinetics of domperidone in Chinese healthy volunteers given an oral dose of 10 mg.  相似文献   

20.
探讨了线性离子阱-傅立叶变换离子回旋共振质谱(LTQ-FT)的数据采集模式对蛋白质组鉴定结果的影响,比较和分析了针对不同复杂程度样本的最佳采集模式.对于α-乳清蛋白4种标准蛋白质酶切肽段混合物的简单体系,在傅立叶变换离子回旋共振腔中选3个最强母离子进行选择离子监测扫描后, 再实施二级碎裂的方法(SIM3) 得到的肽段覆盖率, 分别是直接选10个最强母离子进行二级碎裂(FT10)方法得到的肽段覆盖率的1.5~1.9倍.另外, 对酵母蛋白酶切肽段混合物的复杂体系鉴定时,只采集双电荷和三电荷母离子进行二级扫描的方法(FT10_23)比单电荷、双电荷和三电荷都采集的方法(FT10_123)得到的图谱鉴定成功率提高64.1%.实验还对不同数据采集模式下图谱的特点进行了考察.本研究表明,针对不同复杂程度的样本,应采取不同的质谱数据采集方法.  相似文献   