首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
Isotope-dilution analysis in combination with GC-ICP-MS detection has been applied to the determination of butyltin species in environmental samples. Different spikes containing the isotopically labeled butyltin species have been synthesized in the laboratory after optimization of the reaction conditions. The isotopic compositions of the tin species in the different spike solutions were determined by GC-ICP-MS after derivatization by aqueous ethylation with sodium tetraethylborate. Reverse isotope-dilution analysis was used for quantitation of the spike solutions by means of natural MBT, DBT, and TBT standards. The mixed spikes were used for simultaneous analysis of MBT, DBT and TBT in the certified reference materials, PACS-2, CRM 462, and CRM 646, with satisfactory results. The excellent agreement of the different speciation results obtained by use of the different spikes is a good indicator of the precision, accuracy, and reliability which can be achieved by using isotope-dilution analysis for trace metal speciation.Application of a double spike containing (119)Sn-enriched MBT (79.7 At%), (118)Sn-enriched DBT (86.7 At%), and (119)Sn-enriched TBT (83.1 At%) also enabled evaluation of the conditions resulting in quantitative extraction of the species from the solid matrix, in combination with possible alterations depending on the different extraction procedures used (mechanical shaking, ultrasounds, and microwaves). Mathematical equations used for this purpose computed the correct species concentrations directly and, additionally, the decomposition factors (from TBT to DBT and from DBT to MBT) after precise measurement of the (119)Sn/(120)Sn and (118)Sn/(120)Sn ratios for all butyltin species by GC-ICP-MS.  相似文献   

2.
Different spike solutions available for the determination of butyltin compounds by isotope dilution analysis are described and applied for the determination of butyltin compounds in PACS-2 certified reference material. Additionally, those spike solutions were evaluated during the course of an interlaboratory exercise organised by the National Research Council of Canada and the Laboratory of the Government Chemist (UK) in order to quantify tributyltin in a pilot sediment. The aim of this project was to evaluate the capabilities of isotope dilution mass spectrometry to reduce the uncertainty in the certification of Reference Materials for the speciation of organotin compounds. All participants were supplied with a 17Sn-enriched TBT solution from the Laboratory of the Government Chemist (UK). In our case, we performed the analysis of the pilot sediment also using a 119Sn enriched spike (mixed mono-, di- and tributyltin) and a 118Sn-119Sn double spike. The use of these additional spike solutions not only allowed the determination of monobutyltin and dibutyltin in the pilot sediment but also the evaluation and correction of possible extraction-derived rearrangement reactions. An excellent agreement amongst our results and between the participants was obtained with a precision of 8.4% RSD at a level of ca. 80 ng TBT g(-1) (as Sn).  相似文献   

3.
The aim of this work is to compare simultaneous isotope dilution analysis of organotin and organomercury compounds by gas chromatography–mass spectrometry (GC–MS) and gas chromatography–inductively coupled plasma mass spectrometry (GC–ICP/MS) on certified bivalve samples. These samples were extracted by microwave with tetramethylammonium hydroxide (TMAH). Derivatization with both NaBEt4 and NaBPr4 was evaluated, and analytical performances were compared. Two CRM materials, BCR-710 and CRM-477, were analyzed by both techniques to verify accuracy. A mixed spike containing 201Hg-enriched methylmercury (MeHg), 199Hg-enriched inorganic mercury (iHg), 119Sn-enriched monobutyltin (MBT), dibutyltin (DBT), and tributyltin (TBT) as well as homemade 116Sn-enriched monophenyltin (MPT), diphenyltin (DPT), and triphenyltin (TPT) was used for the isotope dilution analysis of samples. The two techniques studied were compared in terms of classic analytical parameters: linearity, precision or repeatability (i.e., percent relative standard deviation, RSD%), limit of detection (LOD), and limit of quantification (LOQ), showing excellent linearity, precision below 12 % for all analytes, and LOQs of 0.06–1.45 pg for GC–MS and 0.02–0.27 pg for GC–ICP/MS.
Figure
?  相似文献   

4.
A new marine sediment certified reference material, NMIJ CRM 7306-a, for butyltin and phenyltin analysis has been prepared and certified by the National Metrological Institute of Japan at the National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). Candidate sediment material was collected at a bay near industrial activity in Japan. After air-drying, sieving, and mixing the material was sterilized with γ-ray irradiation. The material was re-mixed and packaged into 250 glass bottles (15 g each) and these were stored in a freezer at −30 °C. Certification was performed by use of three different types of species-specific isotope-dilution mass spectrometry (SSID–MS)—SSID–GC–ICP–MS, SSID–GC–MS, and SSID–LC–ICP–MS, with 118Sn-enriched organotin compounds synthesized from 118Sn-enriched metal used as a spike. The 118Sn-enriched mono-butyltin (MBT), dibutyltin (DBT), and tributyltin (TBT) were synthesized as a mixture whereas the 118Sn-enriched di-phenyltin (DPhT) and triphenyltin (TPhT) were synthesized individually. Four different extraction methods, mechanical shaking, ultrasonic, microwave-assisted, and pressurized liquid extraction, were adopted to avoid possible analytical bias caused by non-quantitative extraction and degradation or inter-conversion of analytes in sample preparations. Tropolone was used as chelating agent in all the extraction methods. Certified values are given for TBT 44±3 μg kg−1 as Sn, DBT 51 ± 2 μg kg−1 as Sn, MBT 67 ± 3 μg kg−1 as Sn, TPhT 6.9 ± 1.2 μg kg−1 as Sn, and DPhT 3.4 ± 1.2 μg kg−1 as Sn. These levels are lower than in other sediment CRMs currently available for analysis of organotin compounds.  相似文献   

5.
A species-specific isotope dilution (ID) method is described for the determination of mono-, di, and tri-butyltin compounds in sediment by gas chromatography-inductively coupled plasma mass spectrometry (GC-ICP-MS), where the mixture of 118Sn-enriched butyltin compounds synthesized in our laboratory was used as a spike. A correction method for the mass bias, a quantitative extraction of the butyltins from sediment, and an assay for the concentration of the standard solution for the reverse ID procedure were investigated to achieve a reliable ID analysis. The spike solution was added with tri-propyltin (TPrT), and the butyltins were extracted by mechanical shaking into acetic acid-tropolone-toluene. The extracted butyltins were ethylated with sodium tetraethylborate and measured by GC-ICP-MS. The mass bias correction factor for the butyltins was calculated with the measured area ratio of 120Sn/118Sn of TPrT in each chromatographic run, and the correction was carried out. The mass bias was well corrected with this in-run correction (the standard uncertainties of the corrected 120Sn/118Sn for the butyltins were in the range 0.03-0.45%, typically 0.25%, with triplicate measurement corresponding to 0.02-0.37% mass bias). The extraction efficiency of mono-butyltin (MBT) from sediment was improved by using tropolone-toluene as the solvent. Well-defined standard solutions for the reverse-ID procedure could be obtained by an assay for the purities of the natural abundance butyltin chloride reagents used for preparing the standard solutions. Overall uncertainties associated with the present method were estimated, where the sediment certified reference materials, PACS-2 and BCR 646, were analyzed. The uncertainty arising from the extraction was the main contributor to the overall uncertainties for MBT and di-butyltin (DBT) determinations, while with the case of tri-butyltin (TBT) determination the uncertainties arising from the purity of TBT chloride reagent used for preparing the standard solution was a large contributor to the overall uncertainties although the uncertainty arising from the extraction was also a main contributor. The analytical results of MBT, DBT, and TBT in both reference materials, except for MBT results in PACS-2, were in good agreement with the certified values in each. The result of MBT in PACS-2 (0.677 +/- 0.049 microg g(-1) as tin, mean +/- expanded uncertainty) was significantly higher than the certified value (0.45 +/- 0.05 microg g(-1)), but closely matched with the lately reported values (Rajendran, Tao, Nakazato and Miyazaki, Analyst, 2000, 125, 1757: 0.62 +/- 0.02 microg g(-1); Chiron, Roy, Cottier and Jeannot, J. Chromatogr. A, 2000, 879, 137: 0.634 +/- 0.082 microg g(-1); Alonso, Encinar, Gonzalez and Sanz-Medal, Anal. Bioanal. Chem., 2002, 373, 432: 0.64 +/- 0.04 microg g(-1). The present method is concluded to be reliable for the determination of MBT, DBT, and TBT in sediment.  相似文献   

6.
Butyltin (tributyltin TBT; dibutyltin DBT and monobutyltin MBT) speciation was measured in the liver of beluga whales from the St Lawrence Estuary and Hudson Strait (northern Quebec). Using GC–MS, liver samples were analysed from 21 beluga whales found dead, stranded along the shores of the St Lawrence during the period 1995–1998. In all cases, including a neonate specimen, the liver was contaminated with butyltin compounds with concentrations in the range 0.04–2.1 mg Sn kg−1 on a dry weight basis. Liver samples of five beluga whales from Hudson Strait obtained in the summer of 1998 were also analysed. For these animals, hepatic butyltin concentrations were consistently below the detection limit (<0.5 ng Sn g−1 for MBT and <0.2 ng Sn g−1 for DBT and TBT). Compared with published data on the contamination by TBT of the marine mammals of the St Lawrence in 1988, these contemporary results clearly indicate that the level of contamination of the beluga whales in this coastal marine ecosystem has not decreased ten years after regulating the use of TBT‐based antifoulants on small craft. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

7.
The fragmentation patterns of butyltin compounds (mono-, di-, and tributyltin) in an electron impact ion source were studied using an isotope pattern reconstruction algorithm with emphasis on isotope ratio measurements from molecular clusters. For this purpose, standards of natural tin isotope abundance and a (119)Sn-enriched mixture of the three compounds were both ethylated and propylated using sodium tetraalkylborates. The corresponding mass spectra of the various tetraalkyltin compounds prepared were obtained by GC/MS after their extraction with hexane.The results showed that pure interference-free molecular clusters were obtained only for certain R(3)Sn(+) ions where no isobaric overlap with R(2)SnH(+) ions occurred (e.g. BuEt(2)Sn(+) overlaps with Bu(2)SnH(+)). These ions are ideal candidates for accurate Sn isotope ratio measurements, while isotope pattern perturbing interferences are observed for other molecular fragments down to Sn(.)(+). Isotope pattern reconstruction algorithm thus can be used as an analytical tool to ensure the absence of molecular interferences--a requirement for accurate isotope ratio measurements from molecular clusters. The relevance of these studies for the determination of butyltin compounds in environmental samples by isotope dilution GC/MS is also discussed.  相似文献   

8.
A standard GC-MS instrument with electron impact ionisation has been used to develop a fast, simple and reliable method for the simultaneous determination of monobutyltin (MBT), dibutyltin (DBT) and tributyltin (TBT) in water samples. Isotope dilution analysis (IDA) is used for the determination of species, taking advantage of a commercially available spike solution containing a mixture of MBT, DBT and TBT enriched in 119Sn. Method detection limits for 100-mL samples were between 0.18 and 0.25 ng L−1 for the three butyltin compounds with typical RSD between 2 and 4% at levels between 100 and 10 ng L−1, respectively. Recovery of tin species in spiked samples (natural water, wastewater and seawater) was quantitative. The stability of butyltin compounds in collected seawater samples was also studied. The addition of a 1% (v/v) glacial acetic acid preserved tin species in the samples for at least 5 days at room temperature. The IDA method was finally implemented in a routine testing laboratory and it was subsequently accredited by the Spanish National Accreditation Body according to the requirements of UNE-EN ISO/IEC 17025.  相似文献   

9.
A new marine sediment reference material (NMIJ CRM 7301-a) for butyltins analysis was prepared and certified by the National Metrological Institute of Japan, National Institute of Advanced Industrial Science and Technology (NMIJ/AIST). The original material of the sediment was collected at a bay near industrial activities in Japan. The sediment material was air-dried, sieved, homogenized, and packaged into 1,000 glass bottles (60 g each). Certification of NMIJ CRM 7301-a was carried out at NMIJ using two different types of species-specific isotope dilution mass spectrometry: isotope dilution–ethylation–gas chromatography/inductively coupled plasma mass spectrometry (GC/ICPMS) and isotope dilution–ethylation–gas chromatography/mass spectrometry (GC/MS). A mixture of 118Sn-enriched monobutyltin, dibutyltin, and tributyltin was synthesized in our laboratory and was used as a spike for both techniques. Certified values are given for tributyltin (0.044±0.004 mg kg–1 as Sn), dibutyltin (0.056±0.006 mg kg–1 as Sn, and monobutyltin (0.058±0.013 mg kg–1 as Sn), being at lower levels than currently available sediment CRMs for the analysis of organotins.  相似文献   

10.
A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography - mass spectrometry. The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30-1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown.  相似文献   

11.
A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography – mass spectrometry. The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30–1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown.  相似文献   

12.
The optimization and application of gas chromatograph coupled with inductively coupled plasma mass spectrometer (GC-ICPMS) (equipped with a commercially available interface) for the speciation of butyltin compounds in freshwater origin sediment and mussel samples is described. Optimization focused on the system parameters that have the greatest effect on signal intensity such as plasma power, ion lenses and make up gas flow (in the interface). Xenon (Xe) containing argon gas (Ar) was applied as tuning gas providing continuous Xe signal for the optimization of system parameters. It was found that plasma power and make up gas are interrelated variables and provide a set of paired optimum values at each power settings. The absolute optimum values obtained at 800 W plasma power and 1.2 L min−1 make up gas flow rate when 7 mm sample depth was adjusted. The optimum settings obtained were then checked by means of a test solution (tetraethyltin dissolved in hexane). Same optimum conditions were found when tin (Sn) transient signals were monitored. Detection limits were calculated for the three species using the optimized system parameters. Detection limits are the following: for monobutyltin (MBT) 5.6 ng Sn kg−1, for dibutyltin (DBT) 6.6 ng Sn kg−1 and for tributyltin (TBT) 3.4 ng Sn kg−1 obtained. Determination of the butyltin compounds were carried out by means of species-specific isotope dilution analysis. The spike solution contained all species investigated but with altered isotopic composition. Each species were enriched in their 119Sn isotope. Concentrations found in Hungarian freshwater origin mussel and sediment samples ranged between 19 and 39 ng g−1for MBT, between 1.2 and 6.3 ng g−1 for DBT and between 1.2 and 3.2 ng g−1 for TBT indicated as Sn in dry weight. Validation of the method was done by means of certified reference materials (BCR CRM 646 and 477). Good agreement was found between certified and experimental values. Normalized deviation (En) was also computed in order to validate the method used. En values obtained ranged between 0.07 and 0.11 for mussel samples and between 0.26 and 0.72 for sediment samples. These values show that isotope dilution-GC-ICPMS methodology is valid for the determination of MBT, DBT and TBT from both types of matrices.  相似文献   

13.
A sensitive and selective procedure for the determination of tributyltin chloride (TBT), dibutyltin dichloride (DBT) and monobutyltin trichloride (MBT) based on solid phase extraction (SPE) with ENVI-Carb non-porous carbon as column material followed by adsorptive cathodic stripping voltammetry (AdSV) in the presence of tropolone is reported. The determination limits achieved using a 500 mL water sample were 210 ng L–1 (as Sn) for TBT, 30 ng L–1 (as Sn) for DBT and 40 ng L–1 (as Sn) for MBT. The method was used to determine the levels of butyltin species in surface water from the yacht harbour at Zewen on the Mosel River and in the tap water supply in Trier.Dedicated to Professor Dr. K. Doerffel and Professor Dr. H. Kriegsmann on the occasion of their 70th birthdays  相似文献   

14.
An accurate, ultra-sensitive and robust method for speciation of mono, di, and tributyltin (MBT, DBT, and TBT) by speciated isotope-dilution gas chromatography-inductively coupled plasma-mass spectrometry (SID-GC-ICPMS) has been developed for quantification of butyltin concentrations in cryogenic biological materials maintained in an uninterrupted cryo-chain from storage conditions through homogenization and bottling. The method significantly reduces the detection limits, to the low pg g(-1) level (as Sn), and was validated by using the European reference material (ERM) CE477, mussel tissue, produced by the Institute for Reference Materials and Measurements. It was applied to three different cryogenic biological materials-a fresh-frozen mussel tissue (SRM 1974b) together with complex materials, a protein-rich material (whale liver control material, QC03LH03), and a lipid-rich material (whale blubber, SRM 1945) containing up to 72% lipids. The commutability between frozen and freeze-dried materials with regard to spike equilibration/interaction, extraction efficiency, and the absence of detectable transformations was carefully investigated by applying complementary methods and by varying extraction conditions and spiking strategies. The inter-method results enabled assignment of reference concentrations of butyltins in cryogenic SRMs and control materials for the first time. The reference concentrations of MBT, DBT, and TBT in SRM 1974b were 0.92 +/- 0.06, 2.7 +/- 0.4, and 6.58 +/- 0.19 ng g(-1) as Sn (wet-mass), respectively; in SRM 1945 they were 0.38 +/- 0.06, 1.19 +/- 0.26, and 3.55 +/- 0.44 ng g(-1), respectively, as Sn (wet-mass). In QC03LH03, DBT and TBT concentrations were 30.0 +/- 2.7 and 2.26 +/- 0.38 ng g(-1) as Sn (wet-mass). The concentration range of butyltins in these materials is one to three orders of magnitude lower than in ERM CE477. This study demonstrated that cryogenically processed and stored biological materials are a promising alternative to conventional freeze-dried materials for organotin speciation analysis, because these are, at present, the best conditions for minimizing degradation of thermolabile species and for long-term archival. Finally, the potential of the analytical method was illustrated by analysis of polar bear (Ursus maritimus) and beluga whale (Delphinapterus leuca) liver samples that had been collected in the Arctic and archived at the Marine Environmental Specimen Bank. Significant concentrations of butyltin compounds were found in the samples and provide the first evidence of the presence of this class of contaminant in the Arctic marine ecosystem. Figure Eye catch image.  相似文献   

15.
An in vitro gastrointestinal digestion approach in combination with species-specific isotope dilution analysis has been employed for the first time to study the transformation reactions as well as the solubilisation of butyltin species throughout a simulated human digestion. Different sample preparation procedures were assayed in order to avoid problems derived from lack of isotope equilibration between the endogenous and the isotopically-enriched added species. A triple spike approach, which can be used to calculate the corrected concentrations of mono-, di-, and tributyltin (MBT, DBT and TBT, respectively), as well as six interconversions, was employed throughout this work. In order to calculate and compare the species degradation factors, a triple spike solution containing each butyltin species enriched in a different isotope was added to the simulated gastric and intestinal fluids before the digestion procedures in the presence and in the absence of a solid biological matrix (commercial mussel tissue). Additionally, by analysing the soluble and insoluble fractions resulting from the simulated digestion of a commercial mussel tissue (gastric and gastric plus intestinal digestion), total mass balances for each butyltin compound could be derived. For this purpose, the isotopically-enriched species were added after the enzymatic digestions in order to avoid problems derived from lack of isotope equilibration. The mass balances provided information not only about the solubilisation but also about the degradation of the butyltin species during the digestion procedures. Good agreement between the degradation factors calculated under all experiments performed in this work and between those reported in previous works were obtained. The most serious degradation observed was that of DBT to produce MBT, whereas slight degradations of TBT and MBT were detected. Moreover, a worrying 61% of the original total butyltin content present in a commercial mussel tissue was found to be solubilised after complete simulated gastrointestinal digestion, with minimal degradation of TBT.  相似文献   

16.
The yellow compounds pyoverdins were isolated from Pseudomonas chlororaphis, which was isolated from mud in Japan. Degradation of tributyltin (TBT), dibutyltin (DBT), and monobutyltin (MBT) by pyoverdin (20 mg) was carried in sea water (30 ml) containing a 6 µg l?1 concentration of TBT, DBT, and MBT at 24 °C for 24 h in aerobic conditions. TBT, DBT, and MBT in sea water were analyzed by gas chromatography–mass spectrometry in selected ion monitoring mode. DBT in sea water was degraded to MBT by pyoverdins isolated from P. chlororaphis. However, TBT and MBT in sea water was not degraded by pyoverdins. The optimum degradation of DBT in sea water was at pH 4.8–8.2, at a temperature 25–30 °C. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

17.
Tin isotopes were fractionated by the liquid-liquid extraction technique with a crown ether, dicyclohexano-18-crown-6. The isotopic ratios of mSn/120Sn (m: 116, 117, 118, 119, 122 and 124) were measured by multi-collector inductively coupled plasma spectrometry (MC-ICP-MS) on a Nu Plasma 500 with a precision better than 0.05 permil amu−1 on each isotopic ratio. Odd atomic mass isotopes (117Sn and 119Sn) showed depletions compared to the even atomic mass isotopes (116Sn, 118Sn, 122Sn and 124Sn). We show that this odd-even staggering property originates from the nuclear field shift effect. The contribution of the nuclear field shift effect to the observed isotope enrichment factor was estimated to be ∼35%.  相似文献   

18.
This paper describes the development of an accelerated solvent extraction methodology that is capable of simultaneously extracting organometallic species of As, Sn and Hg in a semi-automated manner. Accelerated solvent extraction (ASE) methods based on previous research on the separate extraction of organotin and -arsenic species in our laboratory were adapted for the co-extraction of six different species from an oyster tissue certified reference material (BCR 710). For the first time, the extraction of MeHg by this technique is also investigated. The proposed ASE conditions employed 50% acetic acid in methanol at a temperature of 100 degrees C with up to five consecutive extraction cycles of 3 minutes. Extraction efficiencies for organoarsenic species ranged from 80% (dimethylarsinic acid, DMA) to 99% for arsenobetaine (AsB). Species of toxicological interest, such as dibutyltin (DBT), tributyltin (TBT) and methylmercury (MeHg), were extracted with mean recoveries of 81, 84 and 76%, respectively. The extracted species were analysed by gas chromatography/inductively coupled plasma mass spectrometry (GC/ICPMS; DBT, TBT and MeHg) and liquid chromatography/inductively coupled plasma mass spectrometry (LC/ICPMS; MMA, DMA, AsB) after ethylation with sodium tetraethylborate or dilution with water, respectively. In addition to those species for which the extraction efficiency was assessed during this study, a further five arsenic species (arsenite, arsenate and three unidentified species), as well as monobutyltin (MBT) and mono-, di- and triphenyltin, could also be extracted from other matrices. The developed ASE method provides a significant improvement over many currently available routine monitoring methods for trace element speciation due to the fact that it is capable of extracting several species of toxicological interest simultaneously and quantitatively.  相似文献   

19.
An automated method for the simultaneous determination of six important organotin compounds namely monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), monophenyltin (MPhT), diphenyltin (DPhT) and triphenyltin (TPhT) in water and sediment samples is described. The method is based on derivatization with sodium tetraethylborate followed by automated headspace-solid-phase micro extraction (SPME) combined with GC-MS under retention time locked (RTL) conditions. Home-synthesized deuterated organotin analogues were used as internal standards. Two high abundant fragment ions corresponding to the main tin isotopes Sn118 and Sn120 were chosen; one for quantification and one as qualifier ion. The method was validated and excellent figures of merit were obtained. Limits of quantification (LOQs) are from 1.3 to 15 ng l(-1) (ppt) for water samples and from 1.0 to 6.3 microg kg(-1) (ppb) for sediment samples. Accuracy for sediment samples was tested on spiked real-life sediment samples and on a reference PACS-2 marine harbor sediment. The developed method was used in a case-study at the harbor of Antwerp where sediment samples in different areas were taken and subsequently screened for TBT contamination. Concentrations ranged from 15 microg kg(-1) in the port of Antwerp up to 43 mg kg(-1) near a ship repair unit.  相似文献   

20.
A flame photometric detector using quartz surface-induced tin emission was designed and evaluated for quantification analysis of butyltin species. It has been demonstrated that this quartz surface-induced tin emission, centred at 390 nm, is more sensitive than the commonly used gas-phase emission at 610 nm. The dependence of detector response on quartz enclosure was studied. The operational variables such as hydrogen–air flow rate, carrier-gas flow rate and purge-gas flow rate were optimized. An analytical procedure for speciation analysis of butyltin species in water using simultaneous hydride generation with sodium borohydride and extraction into dichloromethane was established. The detection limits (defined as the signals that equal three times the deviations of the noise) were 0.3 pg of Sn for tetrabutyltin (TeBT), 5 pg of Sn for monobutyltin (MBT), 18 pg of Sn for dibutyltin (DBT) and 2 pg of Sn for tributyltin (TBT), which are approximately 10- to 30-fold better than those reported for using more commonly used gas-phase emission centred at 610 nm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号