首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel on-line HPLC-cupric reducing antioxidant capacity (CUPRAC) method was developed for the selective determination of polyphenols (flavonoids, simple phenolic and hydroxycinnamic acids) in complex plant matrices. The method combines chromatographic separation, constituent analysis, and post-column identification of antioxidants in plant extracts. The separation of polyphenols was performed on a C18 column using gradient elution with two different mobile phase solutions, i.e., MeOH and 0.2% o-phosphoric acid. The HPLC-separated antioxidant polyphenols in the extracts react with copper(II)-neocuproine (Cu(II)-Nc) reagent in a post-column reaction coil to form a derivative. The reagent is reduced by antioxidants to the copper(I)-neocuproine (Cu(I)-Nc) chelate having maximum absorption at 450 nm. The negative peaks of antioxidant constituents were monitored by measuring the increase in absorbance due to Cu(I)-Nc. The detection limits of polyphenols at 450 nm (in the range of 0.17-3.46 μM) after post-column derivatization were comparable to those at 280 nm UV detection without derivatization. The developed method was successfully applied to the identification of antioxidant compounds in crude extracts of Camellia sinensis, Origanum marjorana and Mentha. The method is rapid, inexpensive, versatile, non-laborious, uses stable reagents, and enables the on-line qualitative and quantitative estimation of antioxidant constituents of complex plant samples.  相似文献   

2.
Three techniques (liquid–liquid extraction, packed bed adsorption and expanded bed adsorption) have been compared for the purification of flavonoids from the leaves of Ginkgo biloba L. A crude Ginkgo extract was obtained by refluxing with ethanol for 3 h. The yield of flavonoids achieved by this crude extraction was about 19% (w/w) and the purity of flavonoids in the concentrated extract was between 1.9 and 2.3% (w/w). The crude extract was then dissolved in deionized water and centrifuged where necessary to prepare clarified feedstock for further purification. For the method using liquid–liquid extraction with ethyl acetate, the purity, concentration ratio and yield of flavonoids were 25.4–31.0%, 16–18 and >98%, respectively. For the method using packed bed adsorption, Amberlite XAD7HP was selected as the adsorbent and clarified extract was used as the feedstock. The dynamic adsorption breakthrough curves and elution profiles were measured. For a feedstock containing flavonoids at a concentration of 0.25 mg/mL, the appropriate loading volume to reach a 5% breakthrough point during the adsorption stage was estimated to be 550–600 mL for a packed bed of volume 53 mL and a flow rate of 183 cm/h. The results from the elution stage indicated that the majority of impurities were eluted by ethanol concentrations of 40% (v/v) or below and efficient separation of flavonoids from the impurities could be achieved by elution of the flavonoids with 50–80% ethanol reaching an average purity of ∼25%. The recovery yield of flavonoids using the packed bed purification method was about 60% of the flavonoids present in the clarified feedstock (corresponding to around 30% for the total flavonoids in the unclarified crude extract). For the method using expanded bed adsorption also conducted with Amberlite XAD7HP as the adsorbent, the optimal operation conditions scouted during the packed bed experiments were used but unclarified crude extract could be loaded directly into the column. For an expanded bed with a settled bed height of 30 cm, the loss of flavonoids in the column flow-through was about 30%. The two-step elution protocol again proved to be effective in separating the adsorbed impurities and flavonoids. More than 96% of the bound impurities were completely removed by 40% ethanol in the first elution stage and less than 4% remained in the final product eluted by 90% ethanol in the second elution stage. Also, ∼74% of the adsorbed flavonoids on column (corresponding to 51% of the total flavonoids in the unclarified feedstock) were recovered in the product. In addition to higher recovery yield, the average process time to obtain the same amount of product was decreased in the expanded bed adsorption (EBA) process. The results suggest that the adoption of EBA procedures can greatly simplify the process flow sheet and in addition reduce the cost and time to purify flavonoids from Ginkgo biloba. These results clearly demonstrate the potential for the use of EBA to purify pharmaceuticals from plant sources.  相似文献   

3.
Sorbent particles consisting of nano and micro silica, and micron size octadecylsilica (ODS) were immobilized using sol-gel chemistry onto poly(dimethylsiloxane) (PDMS) microfluidic channels to serve as μ-chip solid phase extraction (SPE) devices. Extraction, preconcentration and purification of biological and chemical analytes were carried out using these. Micro and nano scale silica-immobilized μ-SPE were used for the extraction/purification of DNA from recombinant Escherichia coli crude lysate. The average DNA recovery was 77 ± 9% (X ± R.S.D.) for the micron size silica particles and 70 ± 5% (X ± R.S.D.) for the nano silica particles. The extracted DNA could be amplified by polymerase chain reaction (PCR) whereas the DNA from the crude lysate solution could not be. This was a testimony to the purification capability of the μ-SPE device. ODS immobilized μ-SPE were used to study the extraction efficiency (EE) and enhancement factor (EF) for three groups of organic compounds, aromatics, phenols and carboxylic acids. They showed poor recovery and low enrichment because the analytes sorbed into the PDMS and were not quantitatively extracted.  相似文献   

4.
The paper deals with the concept of simple automated creation of gradient profile of the mobile phase for gradient-elution sequential injection chromatography (GE-SIC). The feasibility and merits of this concept are demonstrated on the separation and simultaneous assay of indomethacin as active principle and of its two degradation products (5-methoxy-2-methylindoleacetic acid and 4-chloro-benzoic acid) in a topical pharmaceutical formulation.The GE-SIC separation was performed with a FIAlab® 3000 SIC set-up (USA) equipped with an Onyx™ Monolithic C18 (25 mm × 4.6 mm, Phenomenex®) column, a six-port selection valve, a 5-mL syringe pump and a fiber-optics UV CCD detector. Ketoprofen was used as an internal standard (IS). The gradient elution was achieved by automated reproducible mixing of acetonitrile and aqueous 0.2% phosphoric acid in the holding coil of the SIC system. Different profiles of the gradient elution were tested. The optimal gradient using two mobile phases 30:70 and 50:50 of acetonitrile/0.2% phosphoric acid (v/v) was achieved under the optimum flow rate 1.2 mL min−1. The chromatographic resolution R between the peaks of all solutes (including the IS) was >2.00. The repeatability of retention times was characterized by the RSD values 0.18-0.30% (n = 6). Net separation time was 3.5 min and the mobile phase consumption was 4.5 mL for a single GE-SIC assay. The figures of merit of the novel GE-SIC method compared well with those of conventional HPLC.  相似文献   

5.
A procedure based on BIA Separations CIM DEAE anion-exchange chromatography was developed to separate double-stranded (ds) RNA of hypovirus infecting phytopathogenic fungus Cryphonectria parasitica. Using a linear gradient of 25 mM 4-morpholinepropanesulfonic acid (MOPS), pH 7.0 as a binding buffer, and 25 mM MOPS, 1.5 M NaCl, 0.1 mM EDTA, 15% isopropanol (v/v), pH 7.0 as an elution buffer, hypoviral dsRNA was additionally purified from nucleic acid species present in preparations partially purified by standard CF-11 cellulose chromatography. Moreover, crude phenol/chloroform extracts of the fungal tissue were also applied to monolithic supports and CIM DEAE chromatograms revealed clear evidence for hypoviral presence without CF-11 chromatography, nucleic acid precipitation, and electrophoresis.  相似文献   

6.
Yu S  Geng J  Zhou P  Wang J  Feng A  Chen X  Tong H  Hu J 《Analytica chimica acta》2008,611(2):173-181
A new hybrid organic-inorganic monolithic column for efficient deoxyribonucleic acid (DNA) extraction was prepared in situ by polymerization of N-(β-aminoethyl)-γ-aminopropyltriethoxysilane (AEAPTES) and tetraethoxysilane (TEOS). The main extraction mechanism was based on the Coulombic force between DNA and the amino silica hybrid monolithic column. DNA extraction conditions, such as pH, ion concentration and type, and loading capacity, were optimized online by capillary electrophoresis with laser-induced fluorescence detection. Under optimal condition, a 6.0-cm monolithic column provided a capacity of 48 ng DNA with an extraction efficiency of 74 ± 6.3% (X ± RSD). The DNA extraction process on this monolithic column was carried out in a totally aqueous system for the successful purification of DNA and removal of proteins. The PBE2 plasmid could be extracted from Bacillus subtilis (B. subtilis) crude lysate within 25 min, and the purified DNA was suitable for the amplification of a target fragment by polymerase chain reaction. This study demonstrates a new attractive solid-phase support for DNA extraction to meet the increasingly miniaturized and automated trends of genetic analyses.  相似文献   

7.
Yildiz L  Başkan KS  Tütem E  Apak R 《Talanta》2008,77(1):304-313
This study aims to identify the essential antioxidant compounds present in parsley (Petroselinum sativum) and celery (Apium graveolens) leaves belonging to the Umbelliferae (Apiaceae) family, and in stinging nettle (Urtica dioica) belonging to Urticaceae family, to measure the total antioxidant capacity (TAC) of these compounds with CUPRAC (cupric ion reducing antioxidant capacity) and ABTS spectrophotometric methods, and to correlate the TAC with high performance liquid chromatography (HPLC) findings. The CUPRAC spectrophotometric method of TAC assay using copper(II)-neocuproine (2,9-dimethyl-1,10-phenanthroline) as the chromogenic oxidant was developed in our laboratories. The individual antioxidant constituents of plant extracts were identified and quantified by HPLC on a C18 column using a modified mobile phase of gradient elution comprised of MeOH-0.2% o-phosphoric acid and UV detection for polyphenols at 280 nm. The TAC values of HPLC-quantified antioxidant constituents were found, and compared for the first time with those found by CUPRAC. The TAC of HPLC-quantified compounds accounted for a relatively high percentage of the observed CUPRAC capacities of plant extracts, namely 81% of nettle, 60-77% of parsley (in different hydrolyzates of extract and solid sample), and 41-57% of celery leaves (in different hydrolyzates). The CUPRAC total capacities of the 70% MeOH extracts of studied plants (in the units of mmol trolox g−1 plant) were in the order: celery leaves > nettle > parsley. The TAC calculated with the aid of HPLC-spectrophotometry did not compensate for 100% of the CUPRAC total capacities, because all flavonoid glycosides subjected to hydrolysis were either not detectable with HPLC, or not converted to the corresponding aglycons (i.e., easily detectable and quantifiable with HPLC) during the hydrolysis step.  相似文献   

8.
9.
Ferrer L  de Armas G  Miró M  Estela JM  Cerdà V 《Talanta》2005,68(2):343-350
An automatic multisyringe flow injection analysis (MSFIA) system coupling a flow-through optical fiber diffuse reflectance sensor with in-line gas-diffusion (GD) separation is proposed for the isolation, preconcentration and determination of traces of volatile and gas-evolving compounds in samples containing suspended solids, with no need for any preliminary batch sample treatment. The flowing methodology overcomes the lost of sensitivity of the in-line separation technique, when performed in a uni-directional continuous-flow mode, through the implementation of disk-based solid-phase extraction schemes. The high selectivity and sensitivity, the low reagent consumption and the miniaturization of the whole assembly are the outstanding features of the automated set-up. The proposed combination of techniques for separation, flow analysis, preconcentration and detection was applied satisfactorily to sulfide determination in environmental complex matrixes. The method based on multicommutation flow analysis involves the stripping of the analyte as hydrogen sulfide from the donor channel of the GD-module into an alkaline receiver segment, whereupon the enriched plug merges with well-defined zones of the chormogenic reagents (viz., N,N-dimethyl-p-phenylenediamine (DMPD) and Fe(III)). The in-line generated methylene blue dye is subsequently delivered downstream to the dedicated optrode cell furnished with a C18 disk, while recording continuously the diffuse reflectance spectrum of the pre-concentrated compound. This procedure provides a linear working range of 20-500 μg l−1 sulfide with a relative standard deviation of 2.2% (n = 10) at the 200 μg l−1 level, and a detection limit of 1.3 μg l−1.  相似文献   

10.
The study aimed to find the best trade-off between separation of the most critical peak pair and analysis time, in enantioselective GC–FID and GC–MS analysis of lavender essential oil, using the GC method-translation approach. Analysis conditions were first optimized for conventional 25 m × 0.25 mm inner diameter (dc) column coated with 6I–VII-O-tert-butyldimethylsilyl-2I–VII-3I–VII-O-ethyl-β-cyclodextrin (CD) as chiral stationary phase (CSP) diluted at 30% in PS086 (polymethylphenylpolysiloxane, 15% phenyl), starting from routine analysis. The optimal multi-rate temperature program for a pre-set column pressure was determined and then used to find the pressures producing the efficiency-optimized flow (EOF) and speed-optimized flow (SOF). This method was transferred to a shorter narrow-bore (NB) column (11 m × 0.10 mm) using method-translation software, keeping peak elution order and separation. Optimization of the enantioselective GC method with the translation approach markedly reduced the analysis time of the lavender essential oil, from about 87 min with the routine method to 40 min with an optimal multi-rate temperature program and initial flow with a conventional inner diameter column, and to 15 min with FID as detector or 13.5 min with MS with a corresponding narrow-bore column, while keeping enantiomer separation and efficiency.  相似文献   

11.
The easy separation of optically active compounds from enzymatic kinetic resolution products by simple precipitation using poly(ethylene glycol)(PEG)-supported carbonates is disclosed. The water-soluble substrate was prepared by the immobilization of (±)-1-phenylethanol onto a middle-molecular weight (av Mw 5000) monomethoxy PEG (MPEG) through a carbonate linker. The enantioselective hydrolysis using Lipase from porcine pancreas (PPL; Type II, Sigma) in a mixed solvent (hexane/buffer = 9:1) proceeded to afford the corresponding optically active compounds. In this system, the separation of the products was achieved by a simple procedure without laborious column chromatography. A hydrophobic spacer between the MPEG moiety and the carbonate linker affected both the reactivity and enantioselectivity, and the substrate with a phenylethyl spacer was hydrolyzed with the highest enantioselectivity (E value = 270).  相似文献   

12.
A fully automated flow-through microcolumn fractionation system with on-line post-extraction derivatization is proposed for monitoring of orthophosphate in solid samples of environmental relevance. The system integrates dynamic sequential extraction using 1.0 mol l−1 NH4Cl, 0.1 mol l−1 NaOH and 0.5 mol l−1 HCl as extractants according to the Hieltjes-Lijklema (HL) scheme for fractionation of phosphorus associated with different geological phases, and on-line processing of the extracts via the Molybdenum Blue (MB) reaction by exploiting multisyringe flow injection as the interface between the solid containing microcolumn and the flow-through detector. The proposed flow assembly, capitalizing on the features of the multicommutation concept, implies several advantages as compared to fractionation analysis in the batch mode in terms of saving of extractants and MB reagents, shortening of the operational times from days to hours, highly temporal resolution of the leaching process and the capability for immediate decision for stopping or proceeding with the ongoing extraction. Very importantly, accurate determination of the various orthophosphate pools is ensured by minimization of the hydrolysis of extracted organic phosphorus and condensed inorganic phosphates within the time frame of the assay. The potential of the novel system for accommodation of the harmonized protocol from the Standards, Measurement and Testing (SMT) Program of the Commission of the European Communities for inorganic phosphorus fractionation was also addressed. Under the optimized conditions, the lowest detectable concentration at the 3σ level was ≤0.02 mg P l−1 for both the HL and SMT schemes regardless of the extracting media. The repeatability of the MB assay was better than 2.5% and the dynamic linear range extended up to 7.0 mg P l−1 in NH4Cl and NaOH media and 15 mg P l−1 whenever HCl is utilized as extractant for both the HL and SMT protocols.  相似文献   

13.
Sequential injection chromatography system equipped with miniaturized 10 mm monolithic column was used for fast simultaneous determination of two pesticides—fenoxycarb (FC) and permethrin (PM). The system was composed of a commercial sequential injection analysis (SIA) system (FIAlab® 3000, 6-port selection valve and 5.0 mL syringe pump), commercially available column Chromolith™ RP-18e (10 mm × 4.6 mm i.d.) (Merck®, Germany) and CCD UV-vis detector (USB 2000, Ocean-optics) with 1.0 cm Z-flow cell, absorbance was monitored at 225 nm. The mobile phase used for analysis was acetonitrile/water (60:40, v/v), flow rates were 0.6 mL min−1 for elution of fenoxycarb and 1.2 mL min−1 for elution of permethrin. For each analysis 4.8 mL of mobile phase was used. The chromatographic resolution between both compounds was >8 and analysis time was <6.5 min under the optimal conditions. Limits of detection were determined at 2.0 μg mL−1 for fenoxycarb and 1.0 μg mL−1 for permethrin. Samples were prepared by diluting with mobile phase and injected volume was 10 μL for each analysis. Developed method was applied to analysis of both pesticides in veterinary pharmaceutical foams and sprays ARPALIT® Neo (Aveflor, Czech Republic). SIC method was compared with validated method (HPLC, reverse phase 100 mm monolithic column, gradient elution).  相似文献   

14.
A specific and highly sensitive liquid chromatography-electrospray mass spectrometry (LC-ESI-MS) method for the direct determination of bupropion (BUP) and its main metabolite hydroxybupropion (HBUP) in rat plasma and brain microdialysate has been developed and validated. The analysis was performed on a Bonus RP C18 (100 mm × 2.1 mm i.d., 3.5 μm particles) column using gradient elution with the mobile phase consisting of acetonitrile and ammonium formate buffer (10 mM, pH 4). Plasma samples were analyzed after a simple, one-step protein precipitation clean-up with trichloroacetic acid (TCA), however clean-up for microdialysis samples was not necessary, enabling direct injection of the samples into the LC-ESI-MS system. Signals of the compounds were monitored under the multiple reaction monitoring (MRM) mode of the LC-ESI-MS (ion trap) for quantification. The precursor to product ion transitions of m/z 240-184 and m/z 256-238 were used to measure BUP and HBUP, respectively. The method was validated in both plasma and microdialysate samples, and the obtained lower limit of quantification (LLOQ) was 1.5 ng mL−1 for BUP and HBUP in both matrices. The intra- and inter-day assay variability was less than 15% for both analytes. This LC-ESI-MS method provided simple sampling, rapid clean-up and short analysis time (<9 min), applicable to the routine therapeutic monitoring and pharmacokinetic studies of BUP and HBUP.  相似文献   

15.
Gel-based and membrane-based flow-through immunoassay formats were investigated for rapid ochratoxin A (OTA) detection in red wine. The flow-through set-up consisted of an antibody containing gel or membrane placed at the bottom of a standard solid-phase extraction column (i.e. the flow-through column), combined with a clean-up column. Different clean-up methods were studied for red wine clarification and purification. The optimal method consisted of passing wine, diluted with an aqueous solution containing 1% polyethylene glycol (PEG 6000) and 5% sodium hydrogencarbonate, through strong anion exchange (SAX) silica. An immunoassay for OTA detection in red wine was optimized and a cut-off level at 2 μg L−1 according to EU legislation was achieved with both formats. A more significant colour difference between blank and spiked samples was observed for the gel-based assay making this superior to the membrane-based assay. The proposed rapid gel-based test was compared with a standard immunoaffinity column - high-performance liquid chromatography - fluorescent detection (IAC-HPLC-FLD) method and a good correlation of the results was obtained for naturally contaminated wine samples.  相似文献   

16.
A method was developed for the determination of V and Ni as tetrapyrroles by High Performance Liquid Chromatography hyphenated to Inductively Coupled Plasma Mass Spectrometry (HPLC-ICP-MS) using reversed phase and elution gradient. Chlorinated solvents and tetrahydrofuran were investigated as regard to separation time and ICP-MS detection efficiencies. The final elution gradient program started from pure methanol to a mixture of 20:80 (v/v) chloroform:methanol. External quantification of V and Ni with inorganic standards by flow injection ICP-MS, used online with HPLC, resulted in 95% of recoveries. The Limits of Detection for V during methanol elution and for Ni during the 20% chloroform gradient elution were evaluated by their minimum detectable concentrations, which were, respectively, 5 μg L− 1 and 8 μg L− 1. The methodology was applied to polar and resin fractions separated from a Brazilian crude oil and a sediment extract from an oil-polluted area in the Guanabara Bay, Rio de Janeiro, Brazil. Vanadium as tetrapyrroles represented the totality of V content in the polar fraction, whereas Ni was in different polar forms in the resin and sediment extract.  相似文献   

17.
A fast, sensitive and selective procedure employing a combination of microwave-assisted extraction (MAE) and solid phase extraction (SPE) was applied prior to liquid chromatographic identification and quantification of phenolic compounds in plant materials. MAE has been tested and optimized for the isolation of phenolic acids (gallic, protocatechuic, p-hydroxybenzoic, chlorogenic, vanilic, caffeic, syringic, p-coumaric, ferulic, sinapic, benzoic, m-coumaric, o-coumaric, rosmarinic, cinnamic acids) and 3,4-dihydroxybenzaldehyde, syringaldehyde, p-hydroxybenzaldehyde, and vanillin in various plants. The effects of experimental conditions on MAE efficiency, such as solvent composition, temperature, extraction time, have been studied. The extraction efficiencies were compared with those obtained by computer-controlled, two-step Soxhlet-like extractions. Plant extracts were purified and phenolic compounds were pre-concentrated using SPE on polymeric RP-105 SPE sorbent prior to HPLC analysis. Chromatographic separation was carried out on a Hypersil BDS C18 column using a mobile phase consisted of 0.3% (v/v) acetic acid in water (solvent A) and methanol (solvent B) at flow rate 0.6 ml min−1 and column temperature 30 °C with gradient elution.  相似文献   

18.
In the last years, the development of new methods for analyzing accurate and precise individual metalloproteins is of increasing importance, since numerous metalloproteins are excellent biomarkers of oxidative stress and diseases. In that way, methods based on the use of post column isotopic dilution analysis (IDA) or enriched protein standards are required to obtain a sufficient degree of accuracy, precision and high limits of detection. This paper reports the identification and absolute quantification of Cu,Zn-superoxide dismutase (Cu,Zn-SOD) in cytosol and mitochondria from mice hepatic cells using a innovative column switching analytical approach. The method consisted of orthogonal chromatographic systems coupled to inductively coupling plasma-mass spectrometry equipped with a octopole reaction systems (ICP-ORS-MS) and UV detectors: size exclusion fractionation (SEC) of the cytosolic and mitochondrial extracts followed by online anion exchange chromatographic (AEC) separation of Cu/Zn containing species. After purification, Cu,Zn-SOD was identified after tryptic digestion by molecular mass spectrometry (MS). The MS/MS spectrum of a doubly charged peptide was used to obtain the sequence of the protein using the MASCOT searching engine. This optimized methodology reduces the time of analysis and avoids the use of sample preconcentration and clean-up procedures, such as cut-off centrifuged filters, solid phase extraction (SPE), precipitation procedures, off-line fractions insolates, etc. In this sense, the method is robust, reliable and fast with typical chromatographic run time less than 20 min. Precision in terms of relative standard deviation (n = 5) is of 3–5% and detection limits is 0.21 ng Cu g−1.  相似文献   

19.
The global determination of anionic surfactants is proposed by using flow injection potentiometry, and by employing specifically developed tubular flow-through ion selective electrodes (ISEs). The low concentration requirements needed for the environmental application are obtained with an on-line preconcentration stage embedded in the flow system, which has as its goal the unattended monitoring of anionic surfactants in surface waters. The on-line preconcentration is achieved by employing an octadecylsilica extraction disk in the FIA system. This stage performs the solid phase extraction (SPE) for the enrichment and purification of the target analytes from common interfering anions. The outlined procedure improves the detection limit of a direct injection system, which is decreased from 10 to 0.25 μM by using a preconcentration volume of 3.0 mL and 50 μL of 75% acetonitrile in water as the eluent. Precision was estimated as 2.9% relative standard deviation (n = 20) for a 0.25 μM (0.070 mg·L− 1) sodium docecylsulfate standard.  相似文献   

20.
A novel hydrophobic sorbent material for on-line column preconcentration and separation systems coupled with atomic spectrometry was developed. Poly(etheretherketone) (PEEK) in the form of turnings was used as packing material and evaluated for trace lead determination in environmental samples. Sample and ammonium diethyl-dithiophosphate (DDPA) reagent were mixed on-line and the Pb(II)-DDPA complex was retained effectively on PEEK-turnings. Isobutyl methyl ketone (IBMK) was adopted for efficient analyte complex elution and subsequently transportation into the nebulizer-burner system for atomization. The developed sorbent material has shown, excellent chemical and mechanical resistance, fast adsorption kinetics permitting the use of high sample flow rates without significant loss of retention efficiency. For 120 s sample preconcentration time the sampling frequency was 20 h−1, the enhancement factor was 110, the detection limit (3 s) was cL = 0.32 μg L−1, and the relative standard deviation (RSD) was sR = 2.2%, at the 50.0 μg L−1 Pb(II) level. The accuracy of the developed method was evaluated by analyzing certified reference materials.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号