首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The chromatographic behaviour of azobenzene and fourteen of its derivatives was studied by reversed-phase high-performance liquid chromatography with a C18 stationary phase. The optimal composition of the mobile phase is 9:1 methanol-0.01 M aqueous sodium dihydrogen phosphate which is 0.0002 M in ethylenediaminetetraacetic acid, with a pH of 4.5. The solutes can be detected spectrophotometrically, voltammetrically or polarographically. Spectrophotometric measurement in the visible range is more sensitive than in the UV range (detection limits of 0.04-0.1 ng at 410 nm compared with 0.3-0.5 ng at 265 nm). Voltammetric detection is highly sensitive for hydroxy and amino derivatives [detection limits 0.02-0.09 ng at +0.8 V (Ag-AgCl)], whereas for other substances the detection limits are a few nanograms. Polarographic detection is the least sensitive [detection limits 4-8 ng at -0.6 V (Ag-AgCl)]. All the calibration graphs exhibit good linearity, but spectrophotometric detection yields a wider linear dynamic range. Voltammetric detection is more precise at low solute concentrations (relative standard deviations of the peak heights 0.5-1.0% and 1.0-1.5% for voltammetric and spectrophotometric detection, respectively, with amounts of solute from 1 to 10 ng).  相似文献   

2.
基于重铬酸根离子(Cr_2O_7~(2-))对胞苷保护的荧光铜纳米簇(Cu NCs)的猝灭作用,构建了一种可用于检测Cr_2O_7~(2-)的荧光传感器.实验结果表明,该传感体系检测Cr_2O_7~(2-)的线性范围为0.05~7.0μmol/L,检出限为24 nmol/L(S/N=3).该传感器对Cr_2O_7~(2-)的检测具有良好的选择性,可用于湖水样中Cr_2O_7~(2-)的检测.  相似文献   

3.
Wang P  Li SF  Lee HK 《Talanta》1998,45(4):657-661
Capillary zone electrophoresis (CZE) of nitrate and chlorate in swimming pool water are described. Nitrate and chlorate were determined simultaneously with an indirect detection method in an electrolyte containing 10 mM chromate and 0.1 mM cetyltrimethylammonium bromide (CTAB). Where chloride concentration was so high that nitrate could not be determined satisfactorily because of interference, a direct detection technology was developed in which 10 mM sulfate and 0.1 mM CTAB were used as the buffer. The wavelength for indirect detection was 254 nm and 214 nm for direct detection. Relative standard deviations of the quantification of nitrate and chlorate in real samples were below 6%. The detection limits were 7 mug ml(-1) for chlorate, and 4 mug ml(-1) (indirect detection) and 0.4 mug ml(-1) (direct detection) for nitrate.  相似文献   

4.
Based on the optimized spectrophotometric determination of pyrogens (of various classes ( p-aminophenol and endotoxins), thermal lensing was applied to the determination of these substances at the submicrogram level. The limit of detection of p-aminophenol, a pyrogenic impurity in pharmaceutical formulations of paracetamol, by reaction with resorcinol in alkaline solutions is 100 ng mL(-1). Phloroglucinol was considered as an analog of resorcinol as a reagent in this reaction. The conditions of spectrophotometric determination of pyrogenic lipopolysaccharides (endotoxins) by ion-pair formation with methylene blue (the limit of detection is 100 ng mL(-1)), by ion-pair formation with Stains-All (1-ethyl-2-[3-(1-ethylnaphtho[1,2-d]thiazolin-2-ylidene)-2-methylpropenyl]naphtho[1,2-d]thiazolium bromide) (the limit of detection is 500 ng mL(-1)), and by reaction of 2-keto-3-deoxyoctonic acid with thiobarbituric acid (the limit of detection is 800 ng mL(-1)) were proposed. The optimized procedure for 2-keto-3-deoxyoctonic acid was applied for thermal lensing that provided a decrease in the limit of detection to 70 ng mL(-1) and was also used for lipopolysaccharide determination in the endotoxin standard from E. coli.  相似文献   

5.
A range of monoclonal antibody-based competitive immunoassays in the format of microtitre plate ELISA and dipstick tests for quantitative and semi-quantitative detection of 4- n -nonylphenol in water was developed. A simple visual dipstick test was based on changing of spot colour from green to brown in the presence of 4- n -nonylphenol at concentrations within the range 10-100 ng mL(-1). Two different detection systems were used for quantitative immunoassay. Application of enhanced chemiluminescence (ECL) resulted in an increase of the sensitivity of ELISA when compared to conventional colorimetric detection. Thus a detection limit of 0.06 ng mL(-1 )of 4- n -nonylphenol was achieved with IC(50) 2.0 ng mL(-1). The tests developed were applied to natural and spiked water samples.  相似文献   

6.
Determination of salbutamol using sequential injection analysis (SIA) with chemiluminescence and fluorescence detection has been devised. The chemiluminescence signal was emitted during the oxidation of salbutamol by potassium permanganate in sulfuric acid medium. Sodium polyphosphate was used as chemiluminescence enhancer. The fluorescence signal (excitation wavelength 230 nm) was also measured in sulfuric acid medium. Both detection techniques were compared with respect to the application of the methods to the determination of salbutamol in biological materials. The sample pre-treatment takes place directly in the SIA system, when salbutamol is adsorbed on the solid-phase (Baker-carboxylic acid) microcolumn integrated into the system. Sulfuric acid serves both as the reagent and the eluent. The lab-made SIA system consisted of a 2.5-mL Cavro syringe pump, ten-port Vici Valco selection valve and Spectra-Physics FS 970 fluorescence detector, which was lab-modified for chemiluminescence detection. The system was controlled by a PC using originally compiled LabVIEW-supported software. Concentrations, volumes of reagents and flow rates were optimised by a simplex method. Salbutamol was determined in the linear range 0.05-10 microg mL(-1) (RSD 1.53%), with the detection limit (3 sigma) 0.03 microg mL(-1) and sample throughput of 42 samples per hour with chemiluminescence detection in standard solutions. The fluorescence detection enabled the determination of salbutamol in standard solutions in the linear range 0.5-100 microg mL(-1) (RSD 2.69%), with the detection limit 0.2 microg mL(-1) and sample throughput of 24 h(-1). The proposed methods were applied to the determination of salbutamol in human serum and urine. However, serum is a very complicated matrix and the SIA-SPE analysis did not provide satisfactory results. It was possible to determine salbutamol in human urine using this technique. Better recovery was achieved with fluorescence detection.  相似文献   

7.
High-voltage contactless conductivity detection of underivatized amino acids in both acidic and basic media is demonstrated. The suitability of different acidic buffer solutions at pH values of about 2.5 was investigated with 12 amino acids. Lactic acid as background electrolyte gave the best results in terms of detection limits for arginine, lysine and histidine, which were approximately 2 x 10(-7), 3 x 10(-7) and 4 x 10(-7) M, respectively. However, the sensitivity for other species was not quite as good and the detection limits in the order of 0.5-1 x 10 (-5) M. The use of basic conditions at pH 10-11 generally led to more stable baselines and more consistent sensitivities. A range of 20 amino acids was investigated with alkaline buffers and detection limits were typically about 10(-6) M. Urine and beer samples were analyzed. Nine and eleven amino acids could be identified, respectively.  相似文献   

8.
Poly-Toluidine Blue film was prepared by electrooxidative polymerization at a glassy carbon electrode in a phosphate buffer solution. The resulting chemically modified electrode (CME) exhibited excellent electrocatalysis toward the oxidation of reduced nicotinamide coenzyme (NADH) with over a 450 mV decrease of the overpotential compared with that at a bare glassy carbon electrode. Two electrochemical determinations of NADH, cyclic voltammetry and flow injection analysis, were established based on the electrocatalytical performance of the resulting modified electrode. Under an identical determinate condition, the voltammetric detection for NADH gave a detection limit of 3.3 micromol L(-1) with a linear concentration range of 9.1 micromol L(-1) to 1.8 mmol L(-1). As a detector in a flow-injection system, the CME gave a detection limit of 0.1 micromol L(-1) for NADH with a linear concentration range of 1.0 micromol L(-1) to 3.2 mmol L(-1). Obviously, flow-injection analysis is superior to voltammetric detection in NADH determination for its lower detection limit and wider detectable linear range.  相似文献   

9.
The determination of biogenic amines in alcoholic beverages is important to assess the potential risks associated with the consumption of high concentrations of these compounds. In addition, product storage conditions and the length of storage can cause the formation of biogenic amines that reduce product quality. We report a new method using cation-exchange chromatography with either suppressed conductivity, integrated pulsed amperometry, UV, or a combination of these detection techniques to determine biogenic amines in alcoholic beverages. The main objective was to provide a direct comparison between IPAD and suppressed conductivity detection for determining biogenic amines in alcoholic beverages. Suppressed conductivity is the simplest detection approach for determining putrescine, cadaverine, histamine, agmatine, phenylethylamine, spermidine, and spermine with good sensitivity (0.004-0.08 mg/l) and was used to evaluate the influence of storage time and conditions on the evolution of biogenic amines in alcoholic beverages. Integrated pulsed amperometric detection (IPAD) detects more biogenic amines than suppressed conductivity detection, enabling the detection of dopamine, tyramine, and serotonin. Tyramine was simultaneously determined by UV detection and IPAD to provide confirmation and ensure the accuracy of the analytical results. The linearity of biogenic amine responses was within 0.1-20 mg/l and peak area precisions were 0.24-4.97% for IPAD, suppressed conductivity-IPAD, and UV detection. The sensitivity for the 10 biogenic amines using the 3 detection techniques varied considerably from 0.004-1.1 mg/l and recoveries were within 85-122%.  相似文献   

10.
Li XA  Zhou DM  Xu JJ  Chen HY 《Talanta》2008,75(1):157-162
In this work, chloride, chlorate and perchlorate are fast separated on PDMS microchip and detected via in-channel indirect amperometric detection mode. With PDMS/PDMS microchip treated by oxygen plasma, anions chloride (Cl-), chlorate (ClO3-), and perchlorate (ClO4-) are separated within 35s. Some parameters including buffer salt concentration, buffer pH, separation voltage and detection potential are investigated in detail. The separation conditions using 15 mM (pH 6.12) of 2-(N-morpholino)ethanesulfonic acid (MES)+L-histidine (L-His) as running buffer, -2000 V as separation voltage and 0.7 V as detection potential are optimized. Under this condition, the detection limits of Cl-, ClO3-, and ClO4- are 1.9, 3.6, and 2.8 microM, respectively.  相似文献   

11.
Glass and PTFE tubes as detection cells were put in small light-tight boxes to achieve miniaturization of batch-and flow-type chemiluminescence detectors for capillary electrophoresis. These light-tight boxes which included a detection cell and a photosensor module were successfully designed. In the batch-type detector using a glass tube as a detection cell, the influences of a repeated injection of sample and a reagent volume of the detection cell on chemiluminescence intensity were examined in detail. By using 3.8 mm I.D. glass tube including 400 microl chemiluminescence reagent solution, the chemiluminescence peaks were reproducibly observed for the repeated injection experiment up to the eight injection with each run time of 3.0 min. Dansyl-Trp was determined over the range 3 x 10(-8)-1 x 10(-5) M with the detection limit of 0.43 fmol (S/N=3). In the flow-type detector using a PTFE tube as a detection cell, both ends of the PTFE tube were connected to three-way joints; a chemiluminescence reagent solution was delivered into the cell and a capillary was inserted through one of the joints while an electrode was inserted through the other one. Dansyl-Trp was determined over the range 1 x 10(-7)-1 x 10(-5) M with the detection limit of 1.3 fmol (S/N=3). By using the compact flow-type detector, a mixture of dansyl-amino acids was separated and detected in micellar electrokinetic chromatography mode.  相似文献   

12.
A heated electrospray interface that affords high sensitivity and long-term signal stability for AAS detection of metal-containing analytes in organic or organic-water solvents after HPLC separation is described. The vitreous body of the electrospray interface is externally heated above the boiling point of the solvent and quartz furnace AAS is used for detection. Interface working conditions were optimized with a full experimental design for the detection of tin- (tetramethyl-, tetraethyl-, tetrabutyl-, and tetrapentyltin, tributyltin chloride, dibutyltin dichloride, and butyltin trichloride) and lead- (tetraethyl- and tetraphenyllead) containing compounds in the column eluate. The heated electrospray interface enables use of a wide range of flow rates - from 50 to 1000 micro L min(-1). The measurement sensitivity and detection limit achieved were compared with those obtained by use of the thermospray interface and post-column conversion of the organotin compounds to gaseous hydrides. The detection limits for the low-molecular weight species of the homologous series (2.8+/-0.1 ng (140+/-5 ng mL(-1)) for tetramethyltin and 3.1+/-0.2 ng (155+/-10 ng mL(-1)) for tetraethyltin) were obtained approximately one order of magnitude lower than those obtained by use of the thermospray interface. With this HPLC-ES-QFAAS system the tributyltin content of BCR reference material 477, mussel tissue, was analyzed. This system was also applied to analysis of tetraethyllead in gasoline samples.  相似文献   

13.
A contactless conductometric detection (CCD) system for capillary electrophoresis (CE) with a flexible detection cell was applied for the simultaneous determination of small anions and/or cations in rain, surface and drainage water samples. The applied frequency, the amplitude of the input signal, the electrolyte conductivity and electrode distance were found to be the most significant factors affecting the detection sensitivity. 2-(N-Morpholino)ethanesulfonic acid/histidine-based (MES/His) electrolytes were used for direct conductivity detection of anions and cations, while ammonium acetate was selected for indirect conductivity determination of alkylammonium salts. For the simultaneous separation procedure, involving dual-opposite end injection, an electrolyte consisting of 20 mM MES/His, 1.5 mM 18-crown-6 and 20 microM cetyltrimethylammonium bromide provided baseline separation of 13 anions and cations in less than 6 min. The detection limits achieved were 7-30 micrograms/l for direct conductometric detection of various common inorganic cations and anions, excluding F- (62 micrograms/l) and H2PO4- (250 micrograms/l), and 35-178 micrograms/l for indirect conductometric detection of alkyl ammonium cations. The developed electrophoretic method with conductometric detection was compared to ion chromatography.  相似文献   

14.
A simple capillary zone electrophoresis procedure was developed for the separation of arsenic species (AsO(2)(2-), AsO(4)(2-), and dimethylarsinic acid, DMA). Both counter-electroosmotic and co-electroosmotic (EOF) modes were investigated for the separation of arsenic species with direct UV detection at 185 nm using 20 mmol L(-1) sodium phosphate as the electrolyte. The separation selectivity mainly depends on the separation modes and electrolyte pH. Inorganic anions (Cl(-), NO(2)(-), NO(3)(-) and SO(4)(2-)) presented in real samples did not interfere with arsenic speciation in either separation mode. To improve the detection limits, sample-stacking techniques, including large-volume sample stacking (LVSS) and field-amplified sample injection (FASI), were investigated for the preconcentration of As species in co-CZE mode. Less than 1 micromol L(-1) of detection limits for As species were achieved using FASI. The proposed method was demonstrated for the separation and detection of As species in water.  相似文献   

15.
Two high-performance liquid chromatographic methods, with ultraviolet-visible spectrophotometry detection (HPLC-UV/Vis) and with tandem mass spectrometry triple quadrupole interfaced with positive ion mode electrospray ionization detection (HPLC-ESI+-QqQ-MS/MS), for determination and quantification of ten commercial dyes are proposed for control in commercial products. Multiple peaks observed for some of the studied dyes in HPLC-UV/Vis chromatograms forced to obtain structural information by HPLC-ESI-MS/MS method with scan mode. The quality parameters of the two proposed chromatographic methods were evaluated for different requirements of normative, showing detection (LODs) and quantification (LOQs) limits around 60-890 and 200-2990 microg L(-1) for HPLC-UV/Vis, and 4.54-14.3 and 15.0-47.6 microg L(-1) for HPLC-ESI+-QqQ-MS/MS.  相似文献   

16.
To investigate probable health benefits of flavonoids and stilbenes in red wine a new reversed-phase (RP) high-performance liquid-chromatographic (HPLC) method with enhanced separation efficiency and improved selectivity, sensitivity, and speed has been established for determination of the flavonoids quercetin, myricetin and kaempferol and the stilbenes cis- and trans-resveratrol, in a single run . UV-absorbance, fluorescence (FLD), and mass-spectrometric (MS) detection were also evaluated. UV-absorbance detection at 320 nm for stilbenes and 377 nm for flavonoids enables their determination up to the nanogram range with a linearity of R2>0.9999 (linear range 50 ng mL(-1)-50 microg mL(-1)). Calculated values of average recoveries were between 95 and 105% for all analytes. For resveratrol, fluorescence detection was highly selective and twice as sensitive as UV detection, and linearity was satisfactory (R2>0.9996; linear range see UV detection). For the detection of the hydrophilic glycosidic compounds piceid and rutin, which are coeluted with other hydrophilic ingredients, the validated RP HPLC system was coupled to a quadrupole ion-trap mass-spectrometer (MS) via an electrospray interface (ESI) with 25% ammonia solution as sheath liquid. MS detection was, highly linear (R2>0.9878; linear range 50 ng mL(-1)-50 microg mL(-1)) for all investigated analytes and the limits of detection were in the low nanogram range. Compared with UV detection MS detection resulted in a 200% increase in signal intensity for myricetin and 400% increases for quercetin and kaempferol, but equal signal intensity for resveratrol. Calculated values of average recoveries were 102% for myricetin and 79% for piceid. Collision induced dissociation (CID) was also used to obtain characteristic fragmentation fingerprints to facilitate qualitative and quantitative analysis even in complex matrices. Finally, this hyphenated HPLC-ESI-MS method was highly suitable and an essential improvement compared with UV- and fluorescence detection.  相似文献   

17.
A method is described using LC-MS-MS for the detection of five different enniatins in grain. The method involves extraction of the fungal secondary metabolites using acetonitrile-water and quantification using LC-MS-MS with atmospheric pressure chemical ionisation, without further treatment of sample extracts. The selected ion reaction of [M + NH4]+ to [M + H]+ was utilised in the specific detection of the compounds. Mean recoveries (n = 5-12) of enniatins from spiked grain samples over a period of six months were 99-115%, 86-131%, 97-113%, 73-100% and 78-114% for beauvericin, enniatin A, A1, B and B1, respectively. The limits of detection were 3.0 microg/kg for beauvericin, enniatin A, B and B1 and 4.0 microg/kg for enniatin A1, which corresponds to on-column detection limits of 7.5 pg and 10 pg, respectively.  相似文献   

18.
Electrochemical detection combined with nanostructured sensor surfaces offers potentially low-cost, high-throughput solutions for detection of clinically significant proteins. Inkjet printing offers an inexpensive non-contact fabrication method for microelectronics that is easily adapted for incorporating into protein immunosensor devices. Herein we report the first direct fabrication of inkjet-printed gold nanoparticle arrays, and apply them to electrochemical detection of the cancer biomarker interleukin-6 (IL-6) in serum. The gold nanoparticle ink was printed on a flexible, heat resistant polyimide Kapton substrate and subsequently sintered to create eight-electrode arrays costing <0.2 euro per array. The inkjet-printed working electrodes had reproducible surface areas with RSD <3%. Capture antibodies for IL-6 were linked onto the eight-electrode array, and used in sandwich immunoassays. A biotinylated secondary antibody with 16-18 horseradish peroxidase labels was used, and detection was achieved by hydroquinone-mediated amperometry. The arrays provided a clinically relevant detection limit of 20 pg mL(-1) in calf serum, sensitivity of 11.4 nA pg(-1) cm(-2), and a linear dynamic range of 20-400 pg mL(-1).  相似文献   

19.
以纳米氮化钛(TiN)为电活性物质,制备了用于检测青霉素的纳米TiN修饰碳糊电极.研究了该碳糊电极中石墨与纳米TiN的质量比、电极面积、溶液pH值及缓冲容量等因素对青霉素检测效果的影响.结果表明,在优化的条件(石墨与TiN的质量比为2∶1,电极面积为1 mm~2,溶液pH值为7.2以及缓冲容量为20 mmol/L KH_2PO_4)下,该电极检出限为2×10~(-5)mol/L,线性检测范围为4×10~(-5)~3.2×10~(-3)mol/L.利用Zeta电位及交流阻抗的方法,揭示了纳米TiN碳糊电极检测青霉素的机理为纳米TiN对青霉素的特异性吸附.纳米TiN碳糊电极展现出良好的稳定性、选择性和重复性,在青霉素检测领域具有广阔的应用前景.  相似文献   

20.
Z Chen  S Qian  X Chen  W Gao  Y Lin 《The Analyst》2012,137(18):4356-4361
In this contribution, bovine serum albumin stabilized gold nanoclusters as novel fluorescent probes were successfully utilized for the detection of methotrexate for the first time. Our prepared gold nanoclusters exhibited strong emission with peak maximum at 633.5 nm. However, the addition of methotrexate induced the strong fluorescence intensity of the gold nanoclusters to decrease. The decrease in fluorescence intensity of the gold nanoclusters caused by methotrexate allowed the sensitive detection of methotrexate in the range of 0.0016 μg mL(-1) to 24 μg mL(-1). The detection limit for methotrexate is 0.9 ng mL(-1) at a signal-to-noise ratio of 3. The present sensor for methotrexate detection possessed a low detection limit and wide linear range. In addition, the real samples were analyzed with satisfactory results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号