首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive method was developed for the trace determination of six tetracyclines and ten of their degradation products in influent, effluent, and river waters using liquid chromatography–electrospray tandem mass spectrometry detection, combined with Oasis hydrophilic–lipophilic balance (HLB) cartridge extraction and Oasis mixed-mode strong anion exchange (MAX) cartridge cleanup. Tetracyclines and their products were separated by liquid chromatography in 9.5 min, and the instrument detection limits were generally between 0.03 and 0.1 μg/L except for minocycline (0.5 μg/L). The chromatograms were improved through the MAX cleanup and no apparent matrix effect was found. The recoveries of all the target compounds except for 4-epianhydrochlortetracycline and anhydrochlortetracycline (34–52%) were 75–120% for influent, 61–103% for effluent, and 64–113% for river waters. The method detection limits (MDLs) of the analytes varied in the range of 0.8–17.5 ng/L in all studied matrices. The method was applied for the determination of tetracyclines and their products in a sewage treatment plant (STP) and surface waters in Beijing, China. Oxytetracycline (3.8–72.5 ng/L), tetracycline (1.9–16.5 ng/L), and five products including 4-epitetracycline, 4-epioxytetracycline, isochlortetracycline, anhydrotetracycline, and 4-epianhydrochlortetracycline (5.7–25.3 ng/L) were detected in wastewater, while only oxytetracycline and tetracycline (2.2 and 2.1 ng/L) were detected in surface water samples.  相似文献   

2.
A reliable multiclass method has been developed and validated for the determination of eight antibiotics from distinct classes (sulfonamides, macrolides, fluoroquinolones, tetracyclines, cephalosporins and dihydrofolate reductase inhibitors) in wastewater – influent and effluent – and surface water from Porto Alegre, Brazil. The pre-concentration and clean-up was conducted with a simple and fast protocol using solid-phase extraction allowing a 100-fold concentration factor. The proposed method was validated by using spiked blank wastewater samples in terms of linearity, repeatability, reproducibility, recovery, matrix effects and limits of detection and quantification. Recovery was obtained in the range of 66–149%. Method limit of quantification ranged between 1.6 and 61.7 ng L?1. Samples (n = 16) were taken from January to August 2011 in one wastewater treatment plant, which uses conventional biological treatment. Sulfamethoxazole and trimethoprim show higher concentration, ranging from >10 to <6500 ng L?1, whereas erythromycin presented the lower amount. Differences between influent and effluent profiles were discussed. Surface water samples (n = 8) were collected in Arroio Diluvio, in four sampling points, in February 2012. From the eight antibiotics analysed, five were detected: sulfamethoxazole, trimethoprim, azythromicyn, ciprofloxacin and norfloxacin, in a concentration range of 376–572 ng L?1, 27–94 ng L?1, 24–40 ng L?1, 16–66ng L?1 and 30–54 ng L?1, respectively.  相似文献   

3.
This paper describes development, optimization and application of analytical method for determination and reliable confirmation of nineteen pharmaceuticals from different therapeutic classes (antibiotics—β-lactams, cephalosporines, sulfonamides, macrolides and tetracyclines; benzodiazepines; antiepileptics and analgoantipyretics) in surface and ground waters at ng l−1 levels. Water samples were prepared using solid-phase extraction and extracts were analyzed by liquid chromatography–ion trap–tandem mass spectrometry with electrospray ionization in both positive and negative ionization mode. The efficiency of ten different SPE cartridges to extract diverse compounds from water was tested. The pH-value of the water sample, the volume of elution solvent and the sample volume were optimized. Matrix effect, especially pronounced for cephalexin and metamizole, was eliminated using matrix-matched standards. It was determined that extraction should be performed at pH ∼ 7.5, i.e. without pH adjustment, and at pH 3, depending on the analyte. Azithromycin, doxycycline and acetylsalicylic acid must be extracted in acidic environment, whereas extraction of paracetamol, ampicillin, erythromycin and metamizole should be performed without pH adjustment. Repeatability of the method was generally lower than 20%. The estimated limits of detection were in the range from 0.15 to 12.46 ng l−1. The method was applied to 26 water samples for monitoring of selected drug residues. Results revealed the presence of carbamazepine (80% of water samples), azithromycin (23%), as well as trimethoprim and paracetamol (both 15%). The most striking was the false positive signal of diclofenac in every analyzed water sample. Confirmation of the positive results was performed by repeated injection of the positive sample extracts using confirmatory method with additional transitions.  相似文献   

4.
A method using high performance liquid chromatography–electrospray tandem mass spectrometry (LC–ESI-MS/MS) in positive ion mode was developed for the simultaneous analysis of 30 phenolic compounds, including four estrogens, bisphenol A (BPA), 10 hydroxylated polybrominated dephenyl ethers (OH-PBDEs) and 15 bromophenols (BRPs), in blood plasma. In the present method, derivatization with dansyl chloride was employed, and all the derivertized target compounds were well resolved on a 100 mm Xbridge C18 column with acetonitrile and 0.1% formic acid as the mobile phases. Purification procedures, such as liquid–liquid extraction and silica-gel chromatography, were applied to reduce matrix effects in the sample extract and remove excess derivatizing reagents, thus permitting selective and sensitive detection of the target phenolic compounds. The limit of quantification for all analytes, with a signal-to-noise ratio of ∼10, was 2–30 pg/g (plasma weight) except for 6-OH-BDE-137 (30 pg/g) and 3-BRP (60 pg/g). The method was validated for recoveries (68–100%), accuracy (84–110%) and precision (3.7–11%) using charcoal-stripped bovine blood plasma spiked with all target compounds (500 and 5000 pg/mL). Finally, the method was applied to analyze six blood plasma samples from frogs and cormorants, where two natural estrogens, one BPA, one OH-PBDE and four BRPs were detected. The greatest total concentrations of estrogens coincided with the least total concentrations of other phenolic compounds for both species. The proposed method based on derivatization followed by LC–MS/MS provides a novel method to simultaneously monitor multiple groups of phenolic compounds in blood plasma.  相似文献   

5.
6.
An optimised and validated method for the determination of pharmaceutical residues in blue mussels (Mytilus spp.) is presented herein, as well as an investigation of the effect of cooking (by steaming) on any potential difference in human exposure risk. Selected pharmaceuticals included two non-steroidal anti-inflammatory drugs (diclofenac and mefenamic acid), an antibiotic (trimethoprim), an anti-epileptic (carbamazepine) and a lipid regulator (gemfibrozil). An in vivo exposure experiment was set up in the laboratory in which mussels were exposed either directly by injection (10 ng) or daily through spiked artificial seawater (ASW) over 96 h. In liquid matrices, pharmaceutical residues were either determined using liquid chromatography–tandem mass spectrometry (LC-MS/MS) directly, or in combination with solid-phase extraction (SPE) for analyte concentration purposes. The extraction of pharmaceuticals from mussel tissues used an additional pressurised liquid extraction step prior to SPE and LC-MS/MS. Limits of quantification of between 2 and 46 ng L?1 were achieved for extracted cooking water and ASW, between 2 and 64 μg L?1 for ASW in exposure tanks, and between 4 and 29 ng g?1 for mussel tissue. Method linearities were achieved for pharmaceuticals in each matrix with correlation coefficients of R 2?>?0.975. A selection of exposed mussels was also cooked (via steaming) and analysed using the optimised method to observe any effect on detectable concentrations of parent pharmaceuticals present. An overall increase in pharmaceutical residues in the contaminated mussel tissue and cooking water was observed after cooking.
Figure
Pharmaceutical residues in cooked and uncooked marine bivalves  相似文献   

7.
Cytokinins (CTKs) are a class of growth-regulating hormones involved in various physiological and developmental processes. More novel analytical methods for the accurate identification and quantitative determination of trace CTKs in plants have been desired to better elucidate the roles of CTKs. In this work, a novel method based on monolithic molecularly imprinted solid-phase extraction followed by liquid chromatography–electrospray tandem mass spectrometry (mMI-SPE-LC-MS/MS) was developed for accurate determination of four CTKs in plant samples. The molecularly imprinted polymer monolith was prepared by using kinetin as the template in syringes and exhibited specific recognition ability for the four CTKs in comparison with that of non-imprinted polymer monolith. Several factors affecting the extraction performance of mMI-SPE, including the pH of loading sample solution, the nature and volume of elution solvent, the flow rate of sample loading, and sample volume, were investigated, respectively. Under the optimized conditions, the proposed mMI-SPE-LC-MS/MS method was successfully applied in the selective extraction and determination of four CTKs in plant tissues, and it offers detection limits (S/N?=?3) of 104, 113, 130, and 89 pg/mL and mean recoveries of 85.9%, 79.3%, 73.5%, and 70.1% for kinetin, kinetin glucoside, trans-zeatin, and meta-topolin (mT), respectively, with the corresponding RSDs less than 15%.
Figure
Trace determination of cytokinins in different plant samples by monolithic molecularly imprinted solid-phase extraction and liquid chromatography–mass spectrometry  相似文献   

8.
Eight naturally occurring capsaicinoids have been determined in Capsicum by use of high-purity standards, with norcapsaicin as an internal standard. The solid standards were rigorously checked for purity. The sensitivity of electrospray ionization (ESI), atmospheric-pressure chemical ionization (APCI), and coordination ion-spray (CIS; with silver) toward the capsaicinoids were measured and compared. The highest sensitivity was found for positive-ion ESI. Method validation of the liquid chromatography–ESI-mass spectrometry (LC–ESI-MS) determination is reported, including tests for repeatability (4%), detection limit (5 pg injected), linear range (20–6 ng injected), quantitation (excellent linearity; <2% relative standard deviation), and recovery (99–103%). The major and minor capsaicinoids in a commercial plant extract and in chili pepper fruits were quantified.Electronic Supplementary Material Supplementary material is available for this article at  相似文献   

9.
This paper reports the development of a fully automated method for the multianalyte determination of twenty pesticides belonging to different classes (triazines, phenylureas, organophosphates, anilines, acidic, propanil, and molinate) in natural and treated waters. The method, based on on-line solid-phase extraction–liquid chromatography–electrospray–tandem mass spectrometry, is highly sensitive (limits of detection between 0.004 and 2.8 ng L–1), precise (relative standard deviations between 2.0 and 12.1%), reliable (two selected reaction-monitoring transitions are monitored per compound), rapid (45 min per sample), and simple. The application of this method to the monitoring of the target compounds in a waterworks revealed the presence of the pesticides investigated at concentrations up to 516 and 82 ng L–1 (total pesticide concentration) in river water and ground water, respectively, used as sources, and their gradual removal through the purification process.Dedicated to the memory of Wilhelm Fresenius  相似文献   

10.
A solid-phase extraction (SPE) LC–MS/MS method for 18 commercial drugs in secondary wastewater and product water from water recycling plants using microfiltration (MF) and reverse osmosis (RO) has been developed, optimised and validated. The method incorporates a range of multi-class pharmaceuticals including lipid lowering agents, analgesics, antipyretics, non-steroidal anti-inflammatory drugs, antidepressants, anticoagulants, tranquilizers, cytostatic agents, and antiepileptics. Method limits of quantitation (MLQs) in secondary wastewater ranged from 15 to 250 ng/L, while MLQs in post-RO water ranged from 1 to 25 ng/L. Results from analysis of secondary wastewater from Western Australia are presented, and represent the largest survey of non-antibiotic pharmaceuticals within Australia to date. Analysis of post-RO water from two MF/RO water recycling facilities also demonstrate that MF/RO treatment removes most pharmaceuticals to below the analytical limits of detection, and more importantly, up to seven orders of magnitude below health-based guideline values.  相似文献   

11.
An automated, sensitive and high-throughput liquid chromatographic/electrospray tandem mass spectrometric (LC–MS/MS) assay was developed for the simultaneous determination of losartan (LOS), its major circulating metabolite EXP-3174 and hydrochlorothiazide (HCTZ) in human plasma. LOS and HCTZ coexist in the same drug formulation, and this is the first method that enables the simultaneous determination of both drugs along with the active metabolite of LOS. Since these drugs have different physicochemical properties, the employment of a liquid–liquid extraction (LLE) protocol was precluded. A fully automated solid-phase extraction (SPE) protocol, based on 96-well format plates, was used to isolate these compounds and furosemide (internal standard, IS) from plasma. Washing and elution steps were amended accordingly in order to minimize any matrix effect from components of the plasma without reducing the elution of the molecules of interest. The compounds were eluted from a C18 column and detected with an API 3000 triple-quadrupole mass spectrometer using negative electrospray ionization and multiple reaction monitoring (MRM). The assay was linear over the range 1.00–400 ng/mL for LOS and EXP-3174 and 0.500–200 ng/mL for HCTZ, respectively, when 200 μl of plasma was used in the extraction. The overall intra- and interassay variations were within acceptance limits. The analysis time for each sample was 4 min, and more than 300 samples could be analyzed in one day by running the system overnight. The assay was simple, highly sensitive, selective, precise, fast, and it enables the reliable determination of LOS, EXP-3174 and HCTZ in pharmacokinetic or bioequivalence studies after per os administration of a single tablet containing both drugs.  相似文献   

12.
An improved selectivity method for the simultaneous determination of four benzotriazoles (benzotriazole, 4-methylbenzotriazole, 5-methylbenzotriazole, and 5,6-dimethyl-1H-benzotriazole) and six benzothiazoles (benzothiazole, 2-hydroxybenzothiazole, 2-benzothiazolamine, mercaptobenzothiazole, 2-methylbenzothiazole, and 2-methylthiobenzothiazole) in aqueous matrices has been developed. Under optimal conditions, analytes are concentrated using a MAX solid-phase extraction (SPE) cartridge, based on divinylbenzene-N-vinylpyrrolidone functionalized with quaternary amine groups, which allows reversed-phase interactions in combination with ionic exchange. Selected compounds are recovered with methanol–acetone 7:3 (v/v) whereas acidic interferences remained attached to the sorbent, and as determined by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), LOQs for surface, urban and industrial wastewater are in the range of 0.002–0.29 ng/mL. Figures of merit of the method revealed good precision (RSD% <12%), linearity (R 2 > 0.99) and accuracy (%R = 80–100%) for surface waters and effluents allowing direct external standard quantification. For more complex samples, such as urban and industrial raw wastewater, either the standard addition method or pseudo-external standard calibration using matrix matched standards are recommended. Analysis of different real samples, surface, urban wastewater and, for the first time, metal industry wastewater, reflected concentrations up to 310 ng/mL. The methylbenzotriazole isomers ratio was also determined.  相似文献   

13.
A simple, fast and sensitive liquid chromatography–electrospray tandem mass spectrometry method was established for trace levels of nine haloacetic acids (HAAs) in drinking water. Water samples were removed of residual chlorine by adding l-ascorbic acid, and directly injected after filtered by 0.22 μm membrane. Nine HAAs were separated by liquid chromatography in 7.5 min, and the limits of detection were generally between 0.16 and 0.99 μg/L except for chlorodibromoacetic acid (1.44 μg/L) and tribromoacetic acid (8.87 μg/L). The mean recoveries of nine target compounds in spiked drinking water samples were 80.1–108%, and no apparent signal suppression was observed. Finally, this method was applied to determine HAAs in the tap water samples collected from five waterworks in Shandong, China. Nine HAAs except for monochloroacetic acid, monobromoacetic acid, dibromochloroacetic acid and tribromoacetic acid were detected, and the total concentrations were 7.79–36.5 μg/L. The determination results well met the first stage of the Disinfectants/Disinfection By-Products (D/DBP) Rules established by U.S.EPA and Guidelines for Drinking-water Quality of WHO.  相似文献   

14.
A sensitive analytical method has been developed and validated for simultaneous determination of pharmaceuticals from different therapeutic classes, i.e. five sulfonamide (SA) and trimethoprim antimicrobials and the anti-inflammatory drug diclofenac, in effluent wastewaters at trace levels. Effluent samples from treatment of wastewater were enriched by solid-phase extraction (SPE) using the Waters Oasis HLB cartridge. The analytes were identified and quantified by reversed-phase liquid chromatography-tandem mass spectrometry operated in the selected reaction monitoring (SRM) mode, using positive electrospray ionization. The pharmaceuticals were, consequently, quantified both by use of isotopically labelled internal standards and by standard addition methods to address the issue of matrix effects related to signal suppression by co-eluting compounds. Average recoveries from fortified samples were usually >70%, with relative standard deviations below 20%. Method detection limits in wastewater matrices were between 7.0 and 10 ng L(-1). Identification points (IPs) were used for unequivocal identification of target analytes in real samples. Diclofenac, trimethoprim, and sulfamethoxazole were mainly detected, in the concentration range 10 to 400 ng L(-1), in effluent samples collected from four different sewage-treatment plants in Greece.  相似文献   

15.
Primary aromatic amines (PAAs) have been broadly studied due to their high toxicity. In this work a method for the analysis of 22 PAAs in aqueous simulants has been developed. The method is based on a solid-phase extraction step using cation-exchange cartridges and the subsequent analysis of the extracts by ultra-high-performance liquid chromatography with mass spectrometric detection. The recoveries obtained for all the amines analyzed ranged between 81 and 109%, linear range was between 0.03 and 75 μg L−1, with the RSD values between 4.5 and 13.4% and an average value of 7.5% and limits of detection at μg L−1 level. The method has been applied to two real samples obtained from migration experiments of polyurethane based laminates to simulant B (water with 3% (w/v) acetic acid) which represents the worst case for the migration of aromatic amines. The main amines found in both samples were methylenedianiline isomers, obtained from the corresponding residual diisocyanates used during polyurethane adhesive polymerization. The total amine concentration found was 26 and 6.3 μg of aniline equivalents per kg of food simulant.  相似文献   

16.
A simple and quick online solid-phase extraction (SPE) coupled to liquid chromatography (LC)/tandem mass spectrometry (MS/MS) for the determination of the five antibiotics (florfenicol, FF; lincomycin, LCM; oxytetracyclin, OTC; tylosin, TS; valnemulin, VLM) in swine wastewater has been developed. After filtration, aliquots (100 μl) of wastewater samples were directly injected to a column-switching LC system. Some matrix interference was removed by washing up SPE column with 0.2% formic acid solution and acetonitrile. Antibiotics eluted from SPE column were separated on analytical column by converting switching valve and were detected by MS/MS. Calibration curves using the method of standard addition had very good correlation coefficients (r > 0.99) in the range of 0.1 to 2 ng/ml. The intra-day precision of the method was less than 12% and the inter-day precision was between 6 to 17%. The detection limits were 0.01–0.1 ng/ml. When this method was applied to wastewater samples in swine facilities, four compounds (LCM, OTC, TS, and VLM) were detected.  相似文献   

17.
We have developed a method using on-line solid-phase extraction–high-performance liquid chromatography–tandem mass spectrometry (SPE-HPLC-MS/MS) and isotope dilution quantification to measure atrazine and seven atrazine metabolites in urine. The metabolites measured were hydroxyatrazine, diaminochloroatrazine, desisopropylatrazine, desethylatrazine, desethylatrazine mercapturate, atrazine mercaturate and atrazine itself. Our method has good precision (relative standard deviations ranging from 4 to 20% at 5, 10 and 50 ng/mL), extraction efficiencies of 67 to 102% at 5 and 25 ng/mL, relative recoveries of 87 to 112% at 5, 25, 50 and 100 ng/mL limits of detection (LOD) ranging from 0.03 to 2.80 ng/mL. The linear range of our method spans from the analyte LOD to 100 ng/mL (40 ng/mL for atrazine and atrazine mercapturate) with R 2 values of greater than 0.999 and errors about the slope of less than 3%. Our method is rapid, cost-effective and suitable for large-scale sample analyses and is easily adaptable to other biological matrices. More importantly, this method will allow us to better assess human exposure to atrazine-related chemicals. Figure A schematic representation showing the elution of the analytes from the solid-phase extraction cartridge onto the analytical column for chromatographic separation prior to MS/MS analysis  相似文献   

18.
A procedure for the determination of three phosphoric acid diesters, eight triesters and triphenylphosphine oxide (TPPO) in water samples is presented. Analytes were simultaneously concentrated using a mixed-mode (reversed-phase and anionic-exchange) solid-phase extraction (SPE) sorbent and then sequentially eluted with methanol (triesters and TPPO) followed by a 20 mM tetrabutylammonium hydrogen sulphate (TBAHS) methanolic solution, case of diesters. After that, they were determined, in two different runs, by liquid chromatography–electrospray ionization–tandem mass spectrometry (LC–ESI–MS/MS), operating the ESI source in the positive (triesters and TPPO) and negative (diesters) ionization modes. The efficiency of the extraction step varied between 70 and 105%, except in the case of tris(2-ethylhexyl) phosphate (TEHP), and it was barely affected by the type of water sample. Moreover, low signal suppression effects were noticed in the ESI ionization of extracts obtained from different environmental water samples. As a result, the standard addition methodology was only required for the accurate quantification of tri-substituted organophosphorus (OPs) species in wastewater samples. Limits of quantification of the optimized method ranged from 0.2 to 10 ng L−1, depending on the sample matrix and the considered compound. The analysis of river and wastewater samples confirmed the occurrence of several tri- and di-substituted OPs in the aquatic environment, with the highest concentrations corresponding to tris(butoxyethyl) phosphate (TBEP) and tris(chloropropyl) phosphate (TCPP).  相似文献   

19.
Triclocarban is an antimicrobial and antibacterial agent found in personal care products and subsequently is a prevalent wastewater contaminant. A quantitative method was developed for the analysis of triclocarban in wastewater effluents using stir bar sorptive extraction–liquid desorption (SBSE–LD) followed by liquid chromatography–tandem mass spectrometry (LC–MS/MS) by means of an electrospray interface. A stir bar coated with polydimethylsiloxane (PDMS) is placed within a vial containing wastewater effluent and is stirred for an hour at room temperature. The PDMS stir bar is then placed in a LC vial containing methanol and is desorbed in a sonicator bath. The methanol is evaporated to dryness and reconstituted in 75% methanol. Spike and recovery experiments in groundwater that did not contain native concentrations of triclocarban were performed at 0.5 μg/L and were 93 ± 8%. Recoveries in wastewater effluent that were corrected for the background levels of triclocarban were 92 ± 2% and 96 ± 5%, respectively, when spiked with 0.5 and 5 μg/L of triclocarban. The precision of the method as indicated by the relative standard error was 2%. The limit of quantitation was 10 ng/L. The SBSE–LD–LC/MS/MS method was applied to wastewater effluent samples collected from northeast Ohio. Triclocarban was quantitated in all five effluent samples, and its concentration ranged from 50 to 330 ng/L. The described method demonstrates a simple, green, low-sample volume, yet, sensitive method to measure triclocarban in aqueous matrices.  相似文献   

20.
Metabolism of four tobacco-specific N-nitrosamines (TSNAs), N′-nitrosonornicotine (NNN), N′-nitrosoanatabine (NAT), N′-nitrosoanabasine (NAB), and 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) has been studied by solid-phase extraction (SPE) and liquid chromatography–tandem mass spectrometry (LC–MS–MS). 4-(Methylnitrosamino)-4-(3-pyridyl)-1-butanol (iso-NNAL) was used as internal standard. SPE and LC–MS–MS was found to be a rapid, simple, sensitive, and selective method for analysis of TSNAs in rabbit serum. The relative standard deviation (R.S.D., n = 6) for analysis of 5 ng mL−1 and 0.5 ng mL−1 standards and of serum sample spiked with 5 ng mL−1 standards of five TSNAs was 2.1–11% and recovery of 5 ng mL−1 standards from serum was 100.2–112.9%. A good linear relationship was obtained between peak area ratio and concentration in the range of 0.2–100 ng mL−1 for NNAL and 0.5–100 ng mL−1 for other four TSNAs, with correlation coefficients (R 2) >0.99 (both linear and log–log regression). Detection limits for standards in solvent were between 0.04 and 0.10 ng mL−1. Doses of TSNAs administered to rabbits via the auricular vein were 4.67 μg kg−1 and 11.67 μg kg−1, in accordance with the different levels in cigarettes. Metabolic curves were obtained for the four TSNAs and for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL), a metabolite of NNK; on the basis of these curves we modeled metabolic kinetic equations for these TSNAs by nonlinear curve fitting.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号