首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method using a sulfur chemiluminescence detector (SCD) has been developed for the qualitative and quantitative determination of sulfur components in stabilized gasoline-range process streams, including blended gasolines containing between 1 and > 4000 ppm total sulfur. The detection limit per sulfur component was approximately 50 ppb. On-column injection was employed for optimum precision and accuracy. A new probe material was found which did not soften under FID operating conditions. A new method, using a hydrogen sulfide permeation tube, was developed for rapid alignment of the probe in the FID.  相似文献   

2.
A previously constructed semi-rotating cryogenic modulator was modified for comprehensive two-dimensional gas chromatography (GC×GC). The retention time repeatability was improved by replacing the modulator control program unit with a new system. Peak widths obtained with the modified modulator were comparable with those obtained with the previous modulator and other modulator types. The modulator was easy to construct and it can be installed in any commercial GC system. The constructed GC×GC–FID system and data obtained by gas chromatography–mass spectrometry (GC–MS) were used for identification of unknowns in forest aerosol samples. Figure A semi-rotating cryogenic modulator in which modulation is based on two-step cryogenic trapping with continuously flowing carbon dioxide has been developed for comprehensive two-dimensional gas chromatography  相似文献   

3.
童婷  张万峰  李东浩  赵锦花  常振阳  高儇博  代威  何生  朱书奎 《色谱》2014,32(10):1144-1151
建立了气流吹扫-注射器微萃取(GP-MSE)与全二维气相色谱/飞行时间质谱(GC×GC/TOFMS)联用分析原油成分的方法。为了找到适用于原油样品分析的GP-MSE条件,用饱和烃混合标准溶液和15种芳烃的混合标准溶液进行了条件优化,得到的最佳条件如下:取样量5 mg、萃取溶剂正己烷20 μ L、载气流速2 mL/min、加热时间3 min、加热温度300 ℃、冷凝温度-2 ℃。处理后的样品在全二维色谱/飞行时间质谱上进样分析,得到了满意结果。方法的检出限为34~93 μg/L,线性相关系数(R2)>0.99,对50种烃类化合物的回收率在82.0%~107.3%之间,相对标准偏差<10%(n=5)。结果表明GP-MSE-GC×GC/TOFMS法是一种新型绿色、高效、灵敏的分析方法,非常适合原油中挥发性与半挥发性组分的分析。  相似文献   

4.
Comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOFMS) was used for the characterization of aromatic compounds present in extra heavy gas oil (EHGO) from Brazil. Individual identification of EHGO compounds was successfully achieved in addition to group-type separation on the chromatographic plane. Many aromatic hydrocarbons, especially polycyclic aromatic hydrocarbons and sulfur compounds, were detected and identified, such as chrysenes, phenanthrenes, perylenes, benzonaphthothiophenes and alkylbenzonaphthothiophenes. In addition, triaromatic steroids, methyl-triaromatic steroids, tetrahydrochrysenes and tetraromatic pentacyclic compounds were present in the EHGO aromatic fractions. Considering the roof-tile effect observed for many of these compound classes and the high number of individual compounds identified, GC×GC-TOFMS is an excellent technique to characterize the molecular composition of the aromatic fraction from EHGO samples. Moreover, data processing allowed the quantification of aromatic compounds, in class and individually, using external standards. EHGO data were obtained in μgg(-1), e.g., benzo[a]pyrene were in the range 351 to 1164μgg(-1). Thus, GC×GC-TOFMS was successfully applied in EHGO quantitative analysis.  相似文献   

5.
Multidimensional gas-chromatographical analysis of various tensides of natural or synthetic origin in cosmetic products is demonstrated. Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry allows the qualitative and quantitative determination of alkyl polyglucosides (AG), fatty alcohol ethoxylates (FAEO), fatty alcohol sulfates (FAS), fatty alcohol ether sulfates (FAES) and cocamidopropyl betaines (CAPB) in shower gel and cleaning agents. The samples were aliquoted in two parts. The first part was silylated, diluted and analysed; then, in order to detect anionic tensides (FAES, FAS) too, the second aliquot was hydrolysed before being silylated for analysis. Because of their amphoteric character, the betaines can only be analysed by gas chromatography after thermal decomposition in the injector, which leads to the corresponding amidoamines among other products.  相似文献   

6.
Three different types of SCD combustion source have been evaluated for use in the chromatographic analysis of atmospheric sulfur compounds. The conventional FID source and the newer inverted burner source were found to be less sensitive and less stable than the flameless design. Overall, the flameless source was superior for use with HRGC-SCD.  相似文献   

7.
Coal is a non renewable fossil fuel, used mainly as a source of electrical energy and in the production of coke. It is subjected to thermal treatment, pyrolysis, which produces coke as a main product, in addition to a condensed liquid by-product, called tar. Tar is a complex mixture of organic compounds which contains different chemical classes, presenting aromatic and sulphur heterocyclic compounds. In general, identification of these compounds requires steps of isolation and fractionation, mainly due to co-elution of these compounds with polyaromatic hydrocarbons (PAH). The objective of this work is to characterize the sulphur compounds present in the coal tar obtained via pyrolysis, using comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry detector (GC×GC/TOFMS). Coal samples from the State of Paraná, Brazil were subjected to laboratorial scale pyrolysis. Several experimental conditions were tested, such as sample weight (5, 10 and 15g), heating ramp (10, 25 and 100°C/min) and final temperature (500, 700 and 900°C). Samples were analyzed by one dimensional gas chromatography (1D-GC) coupled to a quadrupole mass spectrometry detector (GC/qMS) and two-dimensional gas chromatography with time-of-flight mass spectrometry detector (GC×GC/TOFMS). The higher amount of sulphur compounds was obtained at a final temperature of 700°C and a heating ramp of 100°C/min. The main classes observed in the color plot were thiophenes, benzothiophenes and alkylated dibenzothiophenes. GC×GC/TOFMS allowed the identification of the greater number of compounds and the separation of several sulphur compounds from one another. Moreover, separation of sulphur compounds from polyaromatic hydrocarbons and phenols was achieved, which was not possible by 1D-GC. Comparing GC×GC/TOFMS and 1D-GC (SIM mode) also showed that 1D-GC, one of the most employed quantification tools for sulphur compounds, can be misleading for detection, identification and quantification, as the number of isomers of sulphur compounds found was greater than theoretically possible.  相似文献   

8.
王楠  张艺  李响  童应鹏  孔宏伟  许国旺 《色谱》2010,28(4):329-335
建立了川芎挥发油的全二维气相色谱/飞行时间质谱(GC×GC/TOF MS)指纹图谱,并结合聚类分析评价了川芎药材的质量。4种萜类和苯酞类物质在DB-Petro×DB-17柱系统上实现了明显的族组分分离。从新都市的1个样品中分离出375种组分,其中相似度、反相似度皆大于800的化合物215个;根据质谱库检索和保留指数验证,或参照标准化合物及文献报道,从中定性了43个化合物。结合偏最小二乘法-判别分析,可以很好地将4个产区的挥发油样品加以区分,并找出20种差异最大的化合物,其中包括4种苯酞类物质。在此基础上,进一步应用正交偏最小二乘法,关联化学成分和抗氧化活性,结果发现,苯酞类物质(如藁本内酯、川芎内酯A和新蛇床内酯)对川芎挥发油样品地区差异的影响最大,其中彭州产川芎样品中苯酞类物质的含量最高。本文通过高分辨色谱技术研究了相邻产地的药物化学组成差异,并将化学指纹及生物学活性相关联,建立了系统的中药质量评价及活性化合物筛选研究模式。  相似文献   

9.
采用全二维气相色谱-硫化学发光检测器,以直馏柴油为研究对象,考察了一维色谱柱初始温度、升温速率及两维柱温温差等条件对含硫化合物分离的影响,建立了直馏柴油中含硫化合物的分析方法。本方法对基质复杂的直馏柴油中含硫化合物的分离,并定性分析或归类了直馏柴油中的主要含硫化合物。以苯并噻吩为测试样,以峰面积对浓度作图,硫的浓度在1~100mg/kg范围内,峰面积与硫的浓度呈线性关系,相关系数大于0.999。与传统一维气相色谱相比,全二维气相色谱技术除可检测到苯并噻吩类、二苯并噻吩类等含硫化合物外,还可检测到直馏柴油中的硫醚类化合物;苯并噻吩类和二苯并噻吩类化合物也可得到较好分离。  相似文献   

10.
A fast and reliable analytical technique for the determination of total sulfur levels in complex hydrocarbon matrices is introduced. The method employed flow injection technique using a gas chromatograph as a sample introduction device and a gas phase dual‐plasma sulfur chemiluminescence detector for sulfur quantification. Using the technique described, total sulfur measurement in challenging hydrocarbon matrices can be achieved in less than 10 s with sample‐to‐sample time <2 min. The high degree of selectivity and sensitivity toward sulfur compounds of the detector offers the ability to measure low sulfur levels with a detection limit in the range of 20 ppb w/w S. The equimolar response characteristic of the detector allows the quantitation of unknown sulfur compounds and simplifies the calibration process. Response is linear over a concentration range of five orders of magnitude, with a high degree of repeatability. The detector's lack of response to hydrocarbons enables direct analysis without the need for time‐consuming sample preparation and chromatographic separation processes. This flow injection‐based sulfur chemiluminescence detection technique is ideal for fast analysis or trace sulfur analysis.  相似文献   

11.
高儇博  常振阳  代威  童婷  张万峰  何生  朱书奎 《色谱》2014,32(10):1058-1065
对石油地质样品的化学组成进行全面准确的剖析,可以获得丰富的地球化学信息,为油气勘探工作提供科学依据。然而,该类样品除了组成复杂之外,还易受到各种物理(如蒸发、乳化、扩散、溶解和吸附)、化学(如光降解)和生物(如微生物降解)过程的影响。这些特点给样品的分析研究工作带来了极大的困难,传统的一维气相色谱/质谱技术很难对其进行理想的分离。全二维气相色谱(GC×GC)作为新发展起来的一种分离技术,在复杂样品分析方面具有独特的优势,虽然在石油地质样品分析中的应用相对较晚,但也日益受到关注。本文主要综述了近5年来GC×GC在石油地质方面国内外的研究进展以及存在的主要问题,并对今后的研究进行了展望。  相似文献   

12.
纪永升  夏彬彬  栾锋  张晓昀  张海霞 《色谱》2010,28(9):826-832
采用半经验量子化学PM3的方法计算出130个有机化合物的描述符,用启发式方法分别对化合物在全二维气相色谱的3支色谱柱上的保留值建立了相应的定量结构-保留相关模型,并对模型进行了检验。所建模型呈现较好的线性,相关系数的平方(R2)均大于0.88,标准偏差(S)均小于0.105,留一法交互检验的相关系数的平方(R2cv)与所建模型的R2相当,说明模型具有良好的稳定性。化合物的预测结果显示所建模型有较准确的预测能力。  相似文献   

13.
The use of multivariate curve resolution (MCR) to build multivariate quantitative models using data obtained from comprehensive two-dimensional gas chromatography with flame ionization detection (GC × GC-FID) is presented and evaluated. The MCR algorithm presents some important features, such as second order advantage and the recovery of the instrumental response for each pure component after optimization by an alternating least squares (ALS) procedure. A model to quantify the essential oil of rosemary was built using a calibration set containing only known concentrations of the essential oil and cereal alcohol as solvent. A calibration curve correlating the concentration of the essential oil of rosemary and the instrumental response obtained from the MCR-ALS algorithm was obtained, and this calibration model was applied to predict the concentration of the oil in complex samples (mixtures of the essential oil, pineapple essence and commercial perfume). The values of the root mean square error of prediction (RMSEP) and of the root mean square error of the percentage deviation (RMSPD) obtained were 0.4% (v/v) and 7.2%, respectively. Additionally, a second model was built and used to evaluate the accuracy of the method. A model to quantify the essential oil of lemon grass was built and its concentration was predicted in the validation set and real perfume samples. The RMSEP and RMSPD obtained were 0.5% (v/v) and 6.9%, respectively, and the concentration of the essential oil of lemon grass in perfume agreed to the value informed by the manufacturer. The result indicates that the MCR algorithm is adequate to resolve the target chromatogram from the complex sample and to build multivariate models of GC × GC-FID data.  相似文献   

14.
Summary Diaromatics are geochemically significant constituents of crude oils. Their determination is usually achieved by elaborate prefractionation methods, such as medium pressure liquid chromatography and HPLC, prior to capillary gas chromatography. The present contribution describes the quantitative analysis of methylnaphthalenes, ethylnaphthalenes, and dimethylnaphthalenes in selected crude oils by two-dimensional capillary GC. Since the method does not comprise any work-up procedure the determination of geochemical parameters (alkylnaphthalene concentration ratios) is performed on the original, untreated crude oil samples. Accordingly, the analytical results reflect the original composition. The influence by evaporational losses in the laboratory is minimized.  相似文献   

15.
The main objective of this study is to develop a methodology for sulfur compounds speciation using two-dimensional gas chromatography coupled with a flame ionization detector and sulfur chemiluminescence detectors. The methodology enhances the ability to detect and quantify the refractory sulfur in petroleum distillates, and it was utilized to screen the molecular differences between distillates of two Kuwaiti heavy crude oils from different reservoirs but with similar physical properties. Despite the similarity in the physical properties, the detailed comparative analysis indicated significant differences in molecular composition, which suggests substantial differences in crude oil processability based on the reactivity of the detected compounds. The distillates that have been considered in this study include heavy naphtha, kerosene, and gas oil. The compositional differences between the distillates were observed using the two-dimensional gas chromatography system with an in-house developed method. This method groups the sulfur compounds into thiols, benzothiophenes (BTs), and dibenzothiophene (DBTs), and it can handle any atmospheric distillate up 365 °C. Furthermore, the method includes the possibility of identifying and quantifying a total number of 44 sulfur species, which covers the previously mentioned sulfur groups.  相似文献   

16.
A high-temperature ionic liquid, trihexyl(tetradecyl)phosphonium bis(trifluoromethane)sulfonamide, was used as the primary column stationary phase for comprehensive two-dimensional gas chromatography (GC × GC). The ionic liquid (IL) column was coupled to a 5% diphenyl/95% dimethyl polysiloxane (HP-5) secondary column. The retention characteristics of the IL column were compared to polyethylene glycol (DB-Wax) and 50% phenyl/50% methyl polysiloxane (HP-50+). A series of homologous compounds that included hydrocarbons, oxygenated organics, and halogenated alkanes were analyzed with each column combination. This comparison showed that the ionic liquid is less polar than DB-Wax but more polar than HP-50+. The most unique feature of the IL × HP-5 column combination is that alkanes, cyclic alkanes, and alkenes eluted in a narrow band in the GC × GC chromatogram; whereas, these compounds occupied a much larger portion of the DB-Wax × HP-5 and the HP-50+ × HP-5 chromatograms. Each column combination was used to analyze diesel fuel. The IL × HP-5 chromatogram displayed narrow bands for three major compound classes in diesel fuel: saturates, monoaromatics, and diaromatics. The IL column was used at temperatures as high as 290 °C for several months without any noticeable changes in column performance.  相似文献   

17.
The separation characteristics of alkylchloroformate-derivatised amino acids (AAs) by using comprehensive two-dimensional gas chromatography (GC×GC) is reported. The use of a low-polarity/polar column set did not provide as good a separation performance as that achieved with a polar/non-polar column set, where the latter appeared to provide less correlation over the separation space. The degree of component correlation in each column set was estimated by using the correlation coefficient (r2; for 1tR and 2tR data) with the low-polarity/polar and polar/low-polarity sets returning correlation coefficients of 0.86, and 0.00 respectively, under the respective conditions employed for the experiments. The 1.5-m non-polar 2D column (0.1-mm ID; 0.1-m film thickness) gave peak halfwidths of the order of 50–80 ms. Linearity of detection was good, over a three order of magnitude concentration range, with typical lower detection limit of ca. 0.01 mg L–1, compared with 0.5 mg L–1 for normal GC operation with splitless injection. The method was demonstrated for analysis of AAs in a range of food and beverage products, including wine, beer and honey. The major AA in these samples was proline. The Heineken beer sample had a relatively more complex and more abundant AA content compared with the other beer sample. The wine and honey samples also gave a range of AA compounds. Repetition of the sample preparation/analysis procedure for the honey sample gave acceptable reproducibility for individual AAs.  相似文献   

18.
气相色谱近年的发展   总被引:1,自引:0,他引:1  
傅若农 《色谱》2009,27(5):584-591
简要阐述了近几年气相色谱(GC)的发展和特点。GC是一个成熟的技术,广泛地应用于各个领域,近几年GC的发展除了继续研究新的固定相和高性能的毛细管色谱柱之外,主要在全二维气相色谱(GC×GC)、快速GC、便携式GC仪和微型GC仪几个方面。近几年新研究的GC固定相主要集中在常温离子液体和各种环糊精的衍生物。现在GC研究者趋向于使用商品化的GC毛细管柱,而商品化的GC毛细管柱应用最多的是以含5%苯基的聚甲基硅氧烷为固定相的色谱柱。GC×GC发展迅猛,特别是关于调制器的研究,已开发出十多种调制模式,并广泛地应用于各个领域。为了适应大量样品的分析和现场分析,研究和开发了多种快速GC方法和仪器以及便携式GC仪。为了仪器的小型化和专属性检测,μGC仪的研究也稳步地发展起来。  相似文献   

19.
This study explores the application of specific thermionic ionisation detection in comprehensive 2-D GC (GC x GC) and represents the first report of GC x GC with nitrogen phosphorus detection (GC x GC-NPD). Of particular interest is the performance of the NPD with respect to peak parameters of asymmetry and sensitivity. Since GC x GC produces much narrower peaks than obtained with fast GC (e.g. 100 ms vs. <1 s) the effect of detector response time and any lack of symmetry arising from the detection step is important if peak separation (resolution) is to be maintained. It was observed that detector gas flows had a significant impact on peak asymmetry and peak magnitude, and that optimisation of the detector was critical, particularly for complex sample analysis by GC x GC-NPD. Peak asymmetries ranging from As = 1.8 to 8.0 were observed under different conditions of detector gas flows. Comparison of GC x GC-NPD with GC x GC-flame ionisation detection (FID) showed the former to be approximately 20 times more sensitive for the detection of nitrogen-containing methoxypyrazines analytes, and GC x GC-NPD had a larger linear detection range compared to GC x GC-FID. Furthermore, comparison of GC x GC-NPD and GC x GC-TOFMS chromatograms for the analysis of coffee head-space demonstrated the benefits of selective detection, ultimately realised in a comparatively simplified contour plot.  相似文献   

20.
In this work the higher peak capacity and resolution of comprehensive two-dimensional gas chromatography (GCxGC) has been successfully applied, for the first time, to tentatively identify several polar organic compounds of organic extracts of aqueous phases resulting from microwave demulsification process of water-in-crude oil emulsions. Results have shown that higher temperatures and longer exposure time to microwave irradiation produced water phases with a wider variety of polar organic compounds. The microwave process showed to be suitable for the extraction of several polar compounds classes of petroleum. The proposed microwave extraction method and GCxGC identification of polar compounds of petroleum samples are of practical interest for the petrochemical industry due to corrosion and related problems associated with these polar compounds in refinery equipments. The GCxGC/time-of-flight MS technique shows to be very important in the total separation of different classes of compounds and allows the identification of many compounds in these classes.  相似文献   