首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Phenylalanine, tyrosine and dihydroxyphenylalanine (DOPA) were identified unambiguously and quantitatively determined in single ventral thoracic nerve cords from the locust, Schistocerca gregaria, by gas chromatography-negative-ion chemical ionisation mass spectrometry. Deuterium-labelled analogues of each compound were added to a single ventral thoracic nerve cord in hydrochloric acid; the tissue was homogenised and the suspension centrifuged. The remaining hydrochloric acid was eliminated azeotropically by repeated additions of acetonitrile followed by evaporation under a stream of nitrogen and the resultant residue derivatised by reaction with hexafluoroisopropanol and pentafluoropropionic anhydride. Under negative-ion chemical ionisation conditions, the hexafluoroisopropanol-pentafluoropropionyl derivatives produced characteristic ions which were sufficiently abundant to be suitable for selected-ion monitoring. This method is highly specific and gave a limit of detection below the nanogram level. The amounts of phenylalanine, tyrosine and DOPA in a single ventral thoracic nerve cord were, respectively, 194 +/- 81, 347 +/- 88 and 11 +/- 11 ng per tissue.  相似文献   

2.
Extraction-derivatisation techniques have been developed for the unambiguous identification of biogenic amines, and their putative amino acid precursors and metabolites (both major and minor), in single ventral thoracic nerve cords of the locust. Schistocerca gregaria, by the use of gas chromatography-negative-ion chemical ionisation mass spectrometry with selected ion monitoring. In addition the configuration of that enantiomer of p-octopamine present in the thoracid nervous system of the locust was established as R using the chiral derivatisation reagent, (-)-heptafluorobutyrylphenylalanyl chloride.  相似文献   

3.
Biogenic amines in the brain of the American cockroach have been identified and quantified by an extraction-derivatisation procedure involving their reaction with ditrifluoromethylbenzoyl chloride (DTFMB) in the aqueous phase followed by extraction into an organic solvent, hydrolysis of phenolic esters and conversion of free hydroxyl groups to trimethylsilyl (TMS) ethers and subsequent analysis by gas chromatography-negative ion chemical ionisation mass spectrometry. The molecular ion of these DTFMB-TMS derivatives carried most of the ion current which made the method highly specific and gave a potential limit of detection below the picogram level. This method establishes unequivocally that the principal amines in cockroach brain are tyramine, p-octopamine, dopamine, 5-hydroxytryptamine and noradrenaline. In contrast to mammalian nervous tissue, the other positional isomers of octopamine, together with the isomeric synephrines, are absent.  相似文献   

4.
5.
A highly sensitive and specific assay was developed for the determination of clenbuterol in bovine plasma and tissues. Clenbuterol and the internal standard [2H9]clenbuterol were measured by gas chromatography-negative-ion chemical ionization mass spectrometry with methane as the reagent gas. Bovine tissues including muscle, liver, heart, kidney, lung, suet, brain, spinal cord and thymus were ground in a buffer of pH 7 and then extracted using ethyl acetate. After two subsequent purification steps, the cleaned-up organic extract was derivatized with pentafluoropropionic anhydride. The mass spectrometer was set to monitor the abundant ions m/z 368 and 377 of the perfluoroacyl derivatives. This assay was performed with 1 ml of plasma or 0.2 g of tissue. The feasibility of this method was demonstrated by the determination of clenbuterol residues as the femtomole level in a variety of tissues.  相似文献   

6.
A highly sensitive and specific assay has been developed for the determination of calcium acetylhomotaurinate and the internal standard (LM 3041) at the picomole level in human plasma and urine by gas chromatography-mass spectrometry with methane as the reagent gas. After a multiple-step extraction process, the cleaned-up organic extract was derivatized with pentafluorobenzoyl chloride at ambient temperature. Subsequently, chlorination followed by amidation of the sulphonic acid group led to the N-pentafluorobenzoyl di-n-butylamide derivatives. The mass spectrometer was set to monitor the abundant [M - HF]- ions (m/z 424 and 438), which were generated in the ion source switched in the negative-ion chemical ionization mode. This assay required 1 ml of plasma or 50 microliters of urine, and the detection limit was 1 ng/ml. The accuracy of the assay was tested day by day with quality control specimens spiked blind to the analyst. The mean difference between the theoretical and actual values was less than 8%.  相似文献   

7.
A method has been developed for the detection of diethylstilbestrol, together with dienestrol and hexestrol, using extraction with a single immunoaffinity column containing antibodies raised against diethylstilbestrol, followed by gas chromatography-negative-ion chemical ionization mass spectrometry. Immunoaffinity columns were prepared by coupling immunoglobulin G fractions obtained from rabbit antisera with a Sepharose matrix. The immunizing agent was synthesized by introducing a carboxyl group into the diethylstilbestrol molecule and coupling this product to bovine serum albumin. The columns were used for immunoadsorption of diethylstilbestrol and other estrogens, after dilution of samples with phosphate buffer, and were eluted with acetone-water (95:5 v/v). A derivatization method suitable for gas chromatographic-mass spectrometric analysis of diethylstilbestrol and other estrogens was developed using pentafluorobenzyl bromide and ethanolic potassium hydroxide as reagents. The derivatives obtained were detectable at the sub-picogram level using gas chromatography with negative-ion chemical ionization mass spectrometry. Recoveries of cis- and trans-diethylstilbestrol, dienestrol and hexestrol from the immunoaffinity columns, determined after extraction from urine, plasma and buffer, ranged from 28 to 96%. The sensitivity for diethylstilbestrol in urine samples was ca. 10 ppt. The method was applied to the analysis of urine from calves given a single dose of 10 mg of diethylstilbestrol. Free and glucuronic acid conjugated diethylstilbestrol decreased with time, but their ratio was variable.  相似文献   

8.
9.
A method for simultaneous determination of prostaglandin E2 (PGE2), prostaglandin F2 alpha (PGF2 alpha), 6-keto-prostaglandin F1 alpha (6-keto-PGF1 alpha), and thromboxane B2 (TxB2) in plasma was developed. After acidification and addition of 2H- and 3H-labelled internal standards, plasma prostanoids were extracted by reversed-phase cartridges and purified by normal-phase high-performance liquid chromatography. The pentafluorobenzyl, methoxime, trimethylsilyl derivatives were formed. Negative-ion chemical-ionization mass spectra with methane as reagent gas show one intense peak at m/z (M - pentafluorobenzyl). This ion was used for selective-ion monitoring. Prostanoid plasma concentrations (pg/ml) in five healthy volunteers were: PGE2 2.0-10.4, PGF2 alpha 2.2-9.8, 6-keto-PGF1 alpha 0.6-1.8, and TxB2 3.0-45.3. However, there is evidence that the TxB2 values may frequently be falsely high because of ex vivo production during the sampling procedure.  相似文献   

10.
S Nakamura  M Takino  S Daishima 《The Analyst》2001,126(6):835-839
A method for the trace level determination of 11 phenols as pentafluorobenzyl (PFB) derivatives by gas chromatography-mass spectrometry (GC-MS) with negative-ion chemical ionization (NICI) is described. First, the conditions for the PFB derivatisation of phenols were optimized and were found to be reaction temperature 80 degrees C and reaction time 5 h. Second, the detection limits using selected ion monitoring (SIM) were compared between trimethylsilylated (TMS) derivatives in the electron ionization (EI) mode and PFB derivatives in the NICI mode. The responses for the PFB derivatives in the NICI mode were 3.3-61 times higher than those of the TMS derivatives in the EI mode. The instrumental detection limits using NICI-SIM ranged from 2.6 to 290 fg. This method was applied to the analysis of phenols in river water using solid-phase extraction. The recoveries of the phenols from a river water sample spiked with standards at 100 ng l-1 with 2-chlorophenol, 4-chloro-3-methylphenol and pentachlorophenol and at 1000 ng l-1 with phenol, 2,4-dimethylphenol, 2,4-dichlorophenol, 2-nitrophenol, 2,4,6-trichlorophenol and 4-nitrophenol were 81.2-106.3% (RSD 5.1-8.0%), except for 2-methyl-4,6-dinitrophenol and 2,4-dinitrophenol, for which the recoveries were 5.8 and 4.2%, respectively, because water contained in the acetone eluate interfered with the derivatisation of these compounds with two electrophilic nitro groups.  相似文献   

11.
A sensitive method is described for the assay of various biogenic amines and their metabolites from brain tissue homogenates. Based on gas chromatography-mass spectrometry and selected ion monitoring, the method allows reliable low-level quantification of the compounds of interest. By careful study of reaction conditions both in the preparation of derivatives for gas chromatography and in the synthesis of deuterated analogues for internal standard use, relatively simple procedures could be applied with good analytical efficiency. Correlation of the results with those obtained by a high-performance liquid chromatographic procedure was also investigated, and a neurologic application of the method is briefly discussed.  相似文献   

12.
trans-4-Hydroxy-2-nonenal (HNE) is an aldehyde end-product of lipid peroxidation in biological systems which is capable of producing a range of powerful biological effects. We wish to describe a sensitive and selective strategy for the determination of HNE in biological samples. The method is based on the formation of the O-pentafluorobenzyl (O-PFB) oxime derivatives of HNE and its deuterated internal standard which, after sample clean-up by solid-phase extraction and purification by high-performance liquid chromatography (HPLC), were derivatised further to trimethylsilyl ethers. Subsequent capillary column gas chromatography-negative-ion chemical ionisation mass spectrometry (GC-NICIMS) using selected-ion monitoring allowed quantitation in the low ng/ml range. The use of an internal standard and the O-PFB oxime derivatives circumvented the problems encountered previously by other workers because of the volatility and instability of HNE. The syn-isomer of HNE O-PFB oxime followed the anti-isomer on the HPLC and GC columns used, giving a distinctive pair of peaks of characteristic relative proportion. Moreover, the NICI mass spectra of the geometrical isomers were significantly different, providing further evidence to validate the identity of any endogenous HNE recovered. The method was used to identify and quantify HNE in platelets, monocytes, plasma and oxidised low-density lipoprotein.  相似文献   

13.
A sensitive and specific procedure is described for the determination of the antisecretory prostaglandin acetyltrimoprostil and its metabolite trimoprostil in human or dog plasma using gas chromatography--negative-ion chemical ionization mass spectrometry (GC--NICI-MS). Trideuterated analogues of both compounds are added to plasma as the internal standards. The plasma is extracted at pH 7.3 with benzene--dichloromethane (9:1), and the residue of the organic extract is reacted at room temperature with pentafluorobenzyl bromide in the presence of 18-crown-6-ether and potassium acetate. The derivatives are reconstituted in heptane, and appropriate aliquots are analyzed by GC--NICI-MS with selected-ion monitoring of the intense (M--C6F5CH2)- fragment ions of acetyltrimoprostil (m/z 419), trimoprostil (m/z 377), and their respective trideuterated analogues (m/z 422 and m/z 380, respectively). Quantitation of an experimental plasma sample is based on a comparison of the m/z 419 versus m/z 422 and m/z 377 versus m/z 380 ion ratios in each sample to that obtained from the analysis of drug-free plasma fortified with various amounts of both protio compounds, and a fixed amount of each trideuterated internal standard. The limit of quantitation of the assay for human plasma is 0.2 ng ml-1 with mean relative standard deviations at this concentration of 15.5% and 9.7% for acetyltrimoprostil and trimoprostil, respectively.  相似文献   

14.
A procedure for the simultaneous assay of clebopride and its major metabolite N-desbenzylclebopride in plasma has been developed. The method utilizes capillary gas chromatography-negative-ion chemical ionization mass spectrometry with selected-ion monitoring of characteristic ions. Employing 2-ethoxy analogues as internal standards, the benzamides were extracted from basified plasma using dichloromethane. Subsequent reaction with heptafluorobutyric anhydride produced volatile mono- and diheptafluorobutyryl derivatives of clebopride and N-desbenzylclebopride, respectively. The methane negative-ion mass spectra of these derivatives exhibited intense high-mass ions ideal for specific quantitation of low levels in biological fluids. Using this procedure the recovery of the drug and metabolite from human plasma was found to be 84.4 +/- 1.5% (n = 3) and 77.4 +/- 4.7% (n = 3), respectively, at 0.5 ng/ml. Measurement of both compounds down to 0.10 ng/ml with a coefficient of variation of less than 10.5% is described. Plasma levels are reported in four volunteers up to 24 h following oral administration of 1 mg of clebopride malate salt.  相似文献   

15.
A method for the determination of estrogens (17alpha-estradiol, 17beta-estradiol, estrone, ethynyl estradiol, and estriol) as pentafluorobenzyl-trimethylsilyl (PFB-TMS) derivatives by gas chromatography-mass spectrometry (GC-MS) with negative-ion chemical-ionization (NICI) is described. The NICI of all the derivatives produced an intense [M-PFB]- ion as the base peak. The reagent gas (methane) flow-rate and the ion source temperature were determined to be 2.0 ml/min and 240 degrees C, respectively, for the optimized NICI-selected ion monitoring (SIM) conditions. The sensitivities of the PFB-TMS derivatives in the NICI mode were 8.0-130 times higher than those of the PFB-TMS derivatives in electron ionization (EI) mode, and 12-25 times higher than those of all the TMS derivatives in the EI mode. This method was applied to the analysis of estrogens in river water using a solid-phase extraction as the sample preparation. The recoveries of the target chemicals from a river-water sample spiked with standards at 2 ng/l level were 85.8-126.5% (RSD, 6.2-13.0%). The methodical detection limits ranged from 0.10 to 0.28 ng/l.  相似文献   

16.
Fast gas chromatography/negative-ion chemical ionization mass spectrometric (GC/NICI-MS) assay combined with rapid and nonlaborious sample preparation is presented for the simultaneous determination of benzodiazepines and alpha-hydroxy metabolites, zaleplon and zopiclone in whole blood. The compounds were extracted from 100 microl of whole blood by simultaneous multitube, microscale liquid-liquid extraction (LLE) and derivatized by N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA), without the need for the time-consuming concentration stage. In the analytical separation, various parameters of fast GC/NICI-MS were applied, e.g. the use of hydrogen as a GC carrier gas, a high carrier gas velocity, a small film thickness of the analytical column, fast MS data acquisition, fast temperature ramping, and high initial and final temperatures of GC column. Sensitive identification, screening and quantitation of 18 compounds of interest were achieved in chromatographic separation in only 4.40 min. Accurate and reproducible results were obtained by using five different and carefully selected deuterated analogues on the basis of the chemical properties of the target analytes. Nevertheless, for alpha-OH-midazolam, and for bromazepam and flunitrazepam at low concentrations, the results can be considered only semiquantitative on the basis of the validation data. The extraction efficiencies ranged from 74.3 to 105.7% and the limits of quantitation (LOQ) from 1 to 100 ng ml(-1). Rapid sample preparation and fast chromatographic separation allowed cost-efficient, reliable and high sample-throughput analyses with a low amount of manual work. The method was fully validated and accredited according to EN ISO/IEC 17025 standards and is applicable for sensitive, reliable and quantitative determination of benzodiazepines, zaleplon and zopiclone, e.g. in clinical and forensic toxicology.  相似文献   

17.
18.
19.
20.
A number of amines are of the utmost importance to the normal function of the nervous system; numerous relationships also exist between certain diseases of the nervous system and the metabolism of these amines. Noradrenaline, serotonin, and histamine are taken as examples to offer some idea of the possibilities and methods of biochemical research that help to elucidate the physiological and pathological processes in the nervous system. The article shows that our knowledge of the functioning of the nervous system, even in a field that has been studied as thoroughly as the transmission of nerve stimuli at synapses, is still in its infancy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号