首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A simple, fast and sensitive liquid chromatography-mass spectrometry (LC-MS) method with automated on-line extraction using turbulent flow chromatography (TFC) for the determination of five catechins in human plasma was developed. In this method, after on-line extraction by its injection onto an extractor column at turbulent flow, five catechins were backwashed onto a reversed phase column via on-line column switching and separated chromatographically at a laminar flow of 1 ml min(-1). Using this tandem LC-LC-MS system, the extraction, the separation and the quantitation of five catechins in human plasma could be achieved with satisfactory selectivity and sensitivity. The limit of detection (S/N = 3) ranged from 0.6 to 2 ng ml(-1). The described procedure was very simple and rapid since no off-line sample preparation was required, total analysis time being 18.5 min.  相似文献   

2.
A reversed-phase, two-dimensional, liquid chromatographic method incorporating column switching and electrochemical detection was used for the direct analysis of the dopamine (D2) agonist (-)-2-(N-propyl-N-2-thienylethylamino)-5-hydroxytetralin hydrochloride in plasma. Sample work-up consisted of addition of internal standard, filtration, then direct injection of the plasma sample onto an internal surface reversed-phase (ISRP) guard column where the dopamine agonist and internal standard were separated from plasma proteins. An automated pneumatic valve was then used to switch to a stronger eluent which stripped the retained substances from the ISRP support onto a C18 analytical column where the analytes were separated from endogenous biological interferences. A dual-electrode electrochemical detector was used to minimize interferences and provide the desired sensitivity. The method has a detection limit of 1.5 ng/ml and requires a total assay time of 20 min per plasma sample. The method is linear from 1.5 to 1000 ng/ml and yielded greater than 80% drug recovery for plasma concentrations greater than 10 ng/ml. Precision for the method at 100 ng/ml yielded a relative standard deviation of 4.4%. Reproducibility was within 6.5% on a 20 ng/ml spiked plasma sample assayed on different days by different people. The method has successfully been applied to human plasma samples and for pharmacokinetic studies in rats and monkeys.  相似文献   

3.
A method for the simultaneous determination of low-molecular-mass organic and inorganic anions in aqueous solutions was developed using isocratic ion chromatography (IC) with suppressed conductimetric detection and column switching. Owing to the large differences in distribution coefficients between sulphate, nitrate and phosphate and the other species, these ions are separated in the first stage on a medium-capacity anion exchanger, whereas the other anions are led through a second column packed with a high-capacity anion-exchange resin via a column-switching valve. After optimization of the switching procedure a spiked drinking water sample was analysed. Fluoride, acetate, butyrate, formate, nitrate, nitrite and phosphate could be determined in addition to the main anions (chloride and sulphate). The time for a complete analysis is less than 20 min and the method can easily be automated. The precision and detection limit are as usual in IC with background suppression.  相似文献   

4.
A simple, fast and sensitive liquid chromatography/atmospheric pressure photoionization mass spectrometry (LC/APPI-MS) method, with automated on-line extraction using turbulent flow chromatography (TFC), was developed for the determination of perfluorooctane sulfonate (PFOS) in river water. In this method, following an on-line extraction by injection onto a column under TFC conditions, PFOS is back-flushed onto a reversed-phase column via on-line column switching, and resolved chromatographically at a laminar flow rate of 1 mL min(-1). Using this tandem LC-LC/APPI-MS system the extraction, separation and selective detection of PFOS in river water could be achieved with satisfactory selectivity and sensitivity. The limit of detection (LOD) (S/N = 3) and the limit of quantitation (LOQ) (S/N = 10)were 5.35 and 17.86 pg mL(-1). The described procedure was very simple since no off-line sample preparation was required, total analysis time being 18.75 min.  相似文献   

5.
An analytical compound procedure is described for the determination of trimethyl- and triethyllead in water samples like rain, melted snow, and surface waters. The method consists of an enrichment step (adsorption onto and elution from silica gel), a chromatographic separation with column switching (HPLC including pre-column enrichment), and a spectrophotometric detection (chemical reaction detector). The detection limits for the whole procedure, starting with 500 ml sample volume, are 15 pg/ml and 20 pg/ml for trimethyl- and triethyllead resp. The standard deviation for repeated analysis of a sample containing 90 pg Et3Pb+/ml is calculated to +/- 4%. The method also covers the analysis of the chemically mixed trialkyllead species Me2EtPb+ and MeEt2Pb+. The investigation of several water samples taken from different locations shows the presence of trimethyl- and triethyllead in the concentration range of 20-100 pg/ml.  相似文献   

6.
4-(2-Pyridylazo) resorcinol (PAR) and citrate were used as pre-column complexing agents for the determination of Nb(V) and Ta(V) as ternary complexes in geological samples. Aliquots of 2 ml of the standard and sample solutions containing the Nb(V) and Ta(V) complexes were loaded onto a concentrator column (C18, 0.4 cm x 4.6 mm) with a carrier mobile phase comprising 20% (v/v) methanol and containing 5 mM acetic acid, 5 mM citric acid and 10 mM tetrabutylammonium bromide (TBABr), pH 6.5 at 2 ml/min for 2 min, with the effluent being directed to waste. An automatic switching valve was then switched to flush both complexes from the concentrator column onto a C18 analytical column using a mobile phase comprising 32% (v/v) methanol and containing 5 mM acetic acid, 5 mM citric acid and 3 mM TBABr, pH 6.5 for 2.5 min. The switching valve was then switched back to the original position, and cleaned with methanol for 7 min to eliminate unwanted species still adsorbed to the concentrator column. This procedure prevented later eluting compounds from reaching the analytical column, which reduced the overall run time. The detection limits of Nb(V) and Ta(V) (determined at a signal-to-noise ratio of 3, detection wavelength of 540 nm and a 2-ml sample volume) were 0.012 and 0.039 ppb for Nb(V) and Ta(V), respectively. Recoveries of Nb(V) and Ta(V) were 99.4 and 96.2%, respectively. The HPLC results obtained from the reference granite and basalt samples agreed well with inductively coupled plasma MS and certified values, but the HPLC method yielded slightly low values of the Nb/Ta ratio.  相似文献   

7.
Polyethylene glycol (PEG) 20000 in low-density polyethylene has been determined using column switching and inverse temperature programming in reversed-phase packed capillary liquid chromatography with evaporative light scattering detection. PEG 20000 was extracted into water from the polyethylene dissolved in toluene and PEG 35000 was added as an internal standard (I.S.). The samples in aliquots of 100 microl were reconcentrated on the enrichment column using a loading mobile phase of acetonitrile-water (3:97, v/v) at a flow-rate of 75 microl/min for 3 min, then back-flushed and separated on the analytical column with acetonitrile-THF-water (40:5:55, v/v) as mobile phase. The column temperature was reduced from 68 to 55 degrees C with a ramp of -1.5 degrees C/min, held constant for 3 min and then reduced further to 45 degrees C with a -1.5 degrees C/min ramp and kept constant for 1 min. The analysis runtime was 20 min. The recovery of PEG 20 000 was determined to 65.1% with 2.8% RSD and the mass limit of detection of PEG 20 000 was 1.25 microg. The within-assay and between day precision of the retention times of both PEG 20000 and PEG 35000 displayed RSD of less than 1.1% (n = 9), while the overall area ratio RSD of 100 microg/ml PEG 20000 over PEG 35000 was 1.3% (n = 9). The method was linear within the investigated concentration range 25-125 microg/ml (R2 = 0.9983). In addition, a mixture of PEG 4000, 8000, 10000, 20000 and 35000 was analysed on the system to demonstrate the possibility of analysing several PEGs in a sample with the use of temperature gradient elution.  相似文献   

8.
Precolumn preconcentration and derivatization on solid sorbents (Bond Elut C18 solid-phase extraction cartridges) of low-molecular-mass aliphatic amines in water samples have been performed using dansyl chloride (Dns-Cl) as derivatization reagent. Conditions for analyte preconcentration and derivatization such as volume sample, reagent concentration, time, pH and temperature reaction were optimised. On the basis of these studies a rapid and sensitive method for screening of aliphatic amines in waters is presented. Up to volumes of 5 ml, samples are drawn through the sorbent, the analytes retained are dansylated at basic pH, at 100 degrees C for 10 min or 85 degrees C for 15 min. The derivatized analytes are desorbed with 0.5 ml of acetonitrile. Twenty microl of the collected extracts are chromatographed in a Hypersyl ODS C18 column using an acetonitrile-imidazole (pH 7) gradient for elution. Seven amines and ammonium were separated within 9 min. The Dns derivatives were monitored at 333 nm with UV detection and at lambda(excitation) = 350 nm and lambda(emission) = 530 nm with fluorescence detection. The different signals are compared. Dynamic ranges from 10 to 250 microg/l and limits of detection at the microgram-per-litre level and relative standard deviations from 2 to 15% were obtained for all the amines. The total analysis time (sample treatment plus chromatography) was less than 25 min. The method was applied to determination and screening analysis of these analytes in real environmental water samples.  相似文献   

9.
A high-performance liquid chromatographic method with column switching has been developed for the simultaneous determination of cefamandole and cefamandole nafate in plasma and urine. The plasma and urine samples were injected onto a precolumn packed with Corasil RP C18 (37-50 microns) after simple dilution with an internal standard solution in 0.05 M phosphoric acid. Polar plasma and urine components were washed out using 0.05 M phosphoric acid. After valve switching, the concentrated drugs were desorbed in back-flush mode and separated by a reversed-phase C8 column with methanol-5 mM tetrabutylammonium bromide (45:55, v/v) as the mobile phase. The method showed excellent precision with good sensitivity and speed, and a detection limit of 0.5 microgram/ml. The total analysis time per sample was less than 30 min, and the mean coefficients of variation for intra- and inter-assay were both less than 4.9%. The method has been successfully applied to plasma and urine samples for human volunteers after intravenous injection of cefamandole nafate.  相似文献   

10.
A new fully automated method was developed for the quantitative analysis of an antibacterial drug, enrofloxacin (ENRO), in both nasal secretions and plasma samples of healthy pigs. The method is based on the use of a pre-column packed with restricted access material (RAM), namely RP-18 ADS (alkyl diol silica), for on-line sample clean-up coupled to a liquid chromatographic (LC) column containing octadecyl silica. The only off-line sample preparation was the 50-fold dilution of nasal secretions and plasma samples in the washing liquid composed of 25 mM phosphate buffer of pH 7.4. A 10 microl diluted sample volume was injected directly onto the pre-column and washed for 7 min. By rotation of a switching valve, the analyte of interest was eluted in the back-flush mode with the LC mobile phase which consisted in a mixture of 25 mM phosphate buffer of pH 3.0 and acetonitrile according to a segmented gradient elution. By a new rotation of the switching valve, the pre-column and the analytical column were equilibrated for 3 min with the initial mobile phases. The flow-rate was 0.8 ml min(-1) for the washing liquid and 1.5 ml min(-1) for the LC mobile phase. ENRO was detected by fluorescence at excitation and emission wavelengths of 278 and 445 nm, respectively. Finally, the developed method was validated using an original strategy based on total measurement error and accuracy profiles as a decision tool. The limits of quantitation of ENRO in plasma and in nasal secretions were 30.5 and 91.6 ng/ml, respectively. The validated method was then applied successfully to the determination of ENRO in healthy pigs treated by intramuscular injection at different doses (2.5, 10 and 30 mg/kg bodyweight) for a pilot study. This method could be also used for the simultaneous analysis of ENRO and its main metabolite, ciprofloxacin (CIPRO).  相似文献   

11.
A sensitive, efficient, high throughput, direct injection bioanalytical method based on a single column and high-performance liquid chromatography (HPLC) with tandem mass spectrometry (MS/MS) was developed for pharmacokinetic analysis of early drug discovery compounds in plasma samples. After mixing with a working solution containing an internal standard each plasma sample was directly injected into a polymer-coated mixed-function column for sample cleanup, enrichment and chromatographic separation. The stationary phase incorporates hydrophilic polyoxyethylene groups and hydrophobic groups to the polymer-coated silica. This allows proteins and macromolecules to pass through the column due to restricted access to the surface of the packing while retaining the drug molecules on the bonded hydrophobic phase. The analytes retained in the column with a largely aqueous liquid mobile phase were then chemically separated by switching to a strong organic mobile phase. The column effluent was diverted from waste to the mass spectrometer for analyte detection. Within 200 plasma sample injections the response ratio (analyte vs. internal standard, %CV = 4.6) and the retention times for analyte and internal standard were found consistent and no column deterioration was observed. The recoveries of test compound in various plasma samples were greater than 90%. The total analysis time was 相似文献   

12.
Conclusion This method is characterized by a minimal sample requirement (1 ml of blood) which also facilitates its use in pediatrics. The simple but effective preparation of sample (combination of ultrafiltration with precolumn switching technique) prolongs the life of the analytical column. The low detection limit, linearity of the calibration curve over a wide range of concentration, good recovery and the absence of interference indicates that this method is suitable for routine analysis. A major disadvantage is the relatively long analysis time (30 min).
HPLC-Methode zur Bestimmung von Cytarabin im Plasma
  相似文献   

13.
A method for the rapid trace analysis of 17 residual pesticides in water by narrow-bore capillary (I.D. 100 microm) gas chromatography-mass spectrometry (GC-MS) using a programmable temperature vaporizer (PTV) was discussed. The method consisted of a large-volume injection (40 microl) by a PTV, high-speed analysis using a narrow-bore capillary column and MS detection. The PTV with solvent vent mode was very useful for large-volume injection into a narrow-bore capillary column because the injected solvent volume could be reduced to less than 2 microl. The analysis time was 8.5 min [less than 50% of the analysis time using conventional columns (I.D. 250 microm)]. A 10-ml volume of river water was extracted by dichloromethane (4 ml), and then the extract was condensed to 1 ml. This extract was analyzed. Mean recoveries for river water spiked at 100 pg/ml ranged from 83.4 to 96.7%. The limit of detections of the 17 pesticides ranged from 1 to 100 pg/ml.  相似文献   

14.
A novel and robust two-dimensional liquid chromatography with ultraviolet detection method (2D-LC–UV) was developed and validated for high-throughput determination of the concentrations of valproic acid (VPA) in human plasma. This 2D-LC system was composed of a first-dimensional LC column, a second-dimensional LC column and an intermediate transfer column. The sample was directly injected into the 2D-LC system after an easy protein precipitation treatment. After online preconcentration and primary separation by the first-dimensional column, the target was captured by an intermediate column and then transferred to second-dimensional column for analysis. The system transferred the target through “central cutting” mode whereby the drug peak was not subject to interference from the matrix. The analysis cycle time was completed within 7.0 min. Compared with other methods that have been developed, the analysis time was reduced and the operation was much easier without any derivatization. The calibration curve was linear over the 5.90–188.94 μg/ml range for the VPA concentrations. The intra-day and inter-day precisions were <5.6%. The recoveries were in the range from 95.2 to 98.0%. This method appears to be sensitive, precise, rapid and low-cost for the quantification of VPA in serum sample.  相似文献   

15.
The development of a simple and sensitive assay for the quantitative analysis of the marine anticancer agent Yondelis (ET-743, trabectedin) in human plasma using liquid chromatography (LC) with column switching and tandem mass spectrometric (MS/MS) detection is described. After protein precipitation with methanol, diluted extracts were injected on to a small LC column (10 x 3.0 mm i.d.) for on-line concentration and further clean-up of the sample. Next, the analyte and deuterated internal standard were back-flushed on to an analytical column for separation and subsequent detection in an API 2000 triple-quadrupole mass spectrometer. The lower limit of quantitation was 0.05 ng mL(-1) using 100 micro l of plasma with a linear dynamic range up to 2.5 ng ml(-1). Validation of the method was performed according to the most recent FDA guidelines for bioanalytical method validation. The time needed for off-line sample preparation has been reduced 10-fold compared with an existing LC/MS/MS method for ET-743 in human plasma, employing a labor-intensive solid-phase extraction procedure for sample pretreatment. The proposed column switching method was successfully applied in phase II clinical trials with Yondelis and pharmacokinetic monitoring.  相似文献   

16.
A specific and sensitive direct-injection high performance liquid chromatography electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS) method has been developed for the rapid identification and quantitative determination of olanzapine, clozapine, and N-desmethylclozapine in human plasma. After the addition of the internal standard dibenzepin and dilution with 0.1% formic acid, plasma samples were injected into the LC/MS/MS system. Proteins and other large biomolecules were removed during an online sample cleanup using an extraction column (1 x 50 mm i.d., 30 microm) with a 100% aqueous mobile phase at a flow rate of 4 mL/min. The extraction column was subsequently brought inline with the analytical column by automatic valve switching. Analytes were separated on a 5 microm Symmetry C18 (Waters) analytical column (3.0 x 150 mm) with a mobile phase of acetonitrile/0.1% formic acid (20:80, v/v) at a flow rate of 0.5 mL/min. The total analysis time was 6 min per sample. The inter- and intra-assay coefficients of variation for all compounds were <11%. By eliminating the need for extensive sample preparation, the proposed method offers very large savings in total analysis time.  相似文献   

17.
Hirata S  Kajiya T  Aihara M  Honda K  Shikino O 《Talanta》2002,58(6):1185-1194
A home made column of commercially available iminodiacetate resin, Muromac A-1 (50–100 mesh) was used to concentrate rare earth elements (REEs) (15 elements: Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) in seawater. An automated low pressure flow analysis method with on-line column preconcentration/inductively coupled plasma mass spectrometry (ICP-MS) is described for the determination of REEs in seawater. Sample solutions (adjusted to pH of 3.0) passed through the column. After washing the column with water, the adsorbed elements were subsequently eluted into the plasma with 0.7 M nitric acid. Calibration curves were accomplished by means of purified artificial seawater with a sample loading time of 120 s. Detection limits (DLs) of the on-line column preconcentration/ICP-MS by eight replicate operations were between 0.040 and 0.251 pg ml−1 for REEs in the artificial seawater. The precision was less than 8.9% for REEs and one sample can be processed in 7 min using a 7 ml of sample. The proposed method was applied to determine REEs in coastal seawater of Hiroshima Bay, Japan.  相似文献   

18.
A high-performance liquid chromatographic method with column switching has been developed for the determination of rifapentine in serum. The serum samples were injected onto a precolumn packed with Corasil RP C18 (37-50 microns) after simple dilution with an internal standard in a 1% ascorbic acid solution. Polar serum components were washed out using 0.05 M phosphate buffer. After valve switching, the concentrated drugs were eluted in the back-flush mode and separated by a mu Bondapak C18 column with acetonitrile-tetrahydrofuran-0.05 M phosphate buffer (pH 7.0) (42:5:53, v/v/v) as the mobile phase. The method showed excellent precision with good sensitivity and speed, and a detection limit of 0.1 microgram/ml. The total analysis time was less than 25 min and the mean coefficients of variation for intra- and inter-assay were less than 4.8%. The method has been successfully applied to serum samples from dogs after the oral administration of rifapentine.  相似文献   

19.
With the aid of a central composite face-centered design, an ion chromatographic method was developed and optimized for analyzing organic acids in tobacco. A Dionex-100 ion chromatograph with an ion suppressor and a conductivity detector, and a Bio-Rad Aminex HPX-87H column were employed. Only 13 analyses were required to optimize two factors: column temperature and eluent strength. Two sets of optimal conditions for separating nine acids were found: 1.8 mM HFBA eluent and 42 °C column temperature, and 0.8 mM HFBA eluent and 50 °C column temperature. The flow-rate was 0.6 ml min−1 and the analysis time was 18 min or less. A sample preparation procedure included extraction of 2 g ground tobacco with 100 ml of 5 mM sulfuric acid solution for 3 h, filtration of the extract, and dilution of the filtrate 10-fold with deionized water.  相似文献   

20.
刘西茜 《应用化学》2009,26(7):872-874
摘要:建立茵陈中滨蒿内酯的溶剂浮选分离富集方法。方法 考察了浮选溶剂、氮气流速、试液 pH、浮选时间及电解质 NaCl 等因素对浮选效果的影响,优选出最佳浮选条件,并由高效液相色谱测定其含量。结果 对最佳条件下的浮选效果进行了评价。结论 加标回收率92.31 ~ 99.97 %; RSD = 3.20 %.溶剂浮选分离富集方法可行。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号