Reversed-phase high-performance liquid chromatographic determination of dexamethasone in bovine tissues. 总被引:2,自引:0,他引:2
A sensitive and selective high-performance liquid chromatographic procedure is described for the determination of the synthetic corticosteroid dexamethasone (DXM), in bovine muscle, kidney, liver and fat tissues, using methylprednisolone as the internal standard. Following extraction with ethyl acetate (muscle, kidney and liver) or diethyl ether (fat) and clean-up of the tissue extract, the drug residue was isolated using a C18 solid-phase extraction column. Separation of DXM was achieved by reversed-phase high-performance liquid chromatography with ultraviolet detection at 254 nm. By using this procedure, DXM levels as low as 0.01 mg kg-1 can be detected in muscle, kidney, liver and fat. 相似文献
2.
3.
4.
5.
6.
Reversed-phase liquid chromatographic determination of plasma levels of adriamycin and adriamycinol 总被引:1,自引:0,他引:1
A method is given for the determination of adriamycin and its main metabolite, adriamycinol in plasma from cancer patients after administration of adriamycin as the free drug or as a complex with DNA. Adriamycin and adriamycinol are extracted in a column from 1 ml of plasma (pH 8.6) using a mixture of chloroform--1-heptanol (8:2). After re-extraction into phosphate buffer pH 2.2, the separation is performed as reversed-phase liquid chromatography on a LiChrosorb RP-2 (5 micron) column with a mobile phase of acetonitrile-water, acidified with phosphoric acid. The precision by quantitation with photometric detection was better than 5% within the range 50-300 ng/ml. Plasma levels of adriamycin and adriamycinol in a cancer patient are presented in this paper. 相似文献
7.
8.
A reversed-phase high-performance liquid chromatographic (HPLC) method has been developed for the determination of trace concentrations of benomyl, carbendazim, aldicarb, aldicarb sulphoxide and aldicarb sulphone in drinking water. A 10-ml sample of water is passed through a 3-cm precolumn, packed with 5-microns C8 sorbent, at a flow-rate of 5 ml/min. The HPLC system is then switched to an acetonitrile-water gradient elution program. The preconcentrated analytes are eluted from, and separated by, the 3-cm C8 precolumn and determined by UV absorption. The total analytical time is 25 min. The lowest detectable concentrations are in the range of 2.5 x 10(-9)-11.0 x 10(-9) g/ml for the five analytes investigated with 10 ml of sample. 相似文献
9.
Ninhydrin has been investigated as a pre-column derivatization reagent for guanidino compounds. The reaction takes place under strongly alkaline conditions, followed by a second step at low pH and elevated temperature. This procedure yields derivatives with favourable fluorescence properties (excitation at 390 nm, emission at 470 nm). Amino acids do not react with ninhydrin under these conditions so that the method can easily be used for biological samples. Reversed-phase HPLC separations of the derivatives of several representative guanidino compounds in human blood have been achieved with gradients consisting of aqueous formic acid and methanol. Fluorescence detection yields quantification limits of about 20 microg L(-1). Hyphenation with electrospray mass spectrometry has been used to confirm the identity of the derivatives. 相似文献
10.
A method for determination of riboflavin in animal feeds using liquid chromatography (LC) was developed for feed samples fortified with riboflavin at 1 mg/lb or greater (up to 10,000 mg/lb). Feed samples were extracted in 0.1 N HCl with heating on a steam bath for 30 min, followed immediately by mechanical shaking for 30 min. Sample extracts were diluted to target volume with 2% acetic acid and filtered; riboflavin was determined by LC on a reversed-phase C18 column with 2% acetic acid-acetonitrile (85 + 15) mobile phase for separation and fluorescence detection with excitation at 460 nm and emission at 530 nm. The extraction was compared with that of the AOAC Official Method for riboflavin in food and feed premixes. The 2 method extractions were not significantly different from each other at the 95% confidence level. The developed method also had good linearity over 4 orders of magnitude, recovery of 95-99% from spiked feed samples, a limit of detection of riboflavin at 0.00034 microg/mL in solution, a limit of quantitation of 0.023 mg/lb in feed, and good ruggedness. 相似文献
11.
Summary A method for the quantitative determination of mexiletine in human plasma by high-performance liquid chromatography has been described. The plasma samples are buffered to pH 12 and extracted on Clin-Elut columns with diethylether-ethylacetate (1:1), after addition of the internal standard, the 2,4,6 methyl analogue of mexiletine. The minimum detectable amount of mexiletine is 50 ng in 0.5 ml plasma. Recovery is between 96–114% and the relative standard deviation at 1.5 ml–1 level of mexiletine is 2.1% Accurate determinations of human plasma levels were performed after oral or intravenous treatment.Part of the work was presented at the 29. Kongreß der Deutschen Gesellschaft für Laboratoriumsmedizin, Hamburg 1985. 相似文献
12.
Reversed-phase high-performance liquid chromatographic method for the assay of oxytetracycline 总被引:1,自引:0,他引:1
The British Pharmacopoeia monograph for oxytetracycline calcium describes an high-performance liquid chromatographic (HPLC) assay which requires packing of the column by the analyst. Presented in this report is an HPLC method for the assay of oxytetracycline which employs a commercially available reversed-phase column and a solvent system which gives improved separation of the antibiotic from common impurities. Results obtained using this method for both bulk and dosage forms of oxytetracycline are in accord with the results of the microbiological assays. 相似文献
13.
An isocratic, sensitive, high-performance liquid chromatographic assay was developed for the determination of the tricyclic nucleoside 1,4,5,6,8-pentaazaacenaphthylene -3-amino-1,5-dihydro-5-methyl-1-beta-D-ribofuranosyl 5'-monophosphate (TCN-P; NSC 280594) and its dephosphorylated metabolite TCN (NSC 154020). Separation was obtained using a C18 Sep-Pak precolumn, a reversed-phase column, and a mobile phase of phosphate buffer--methanol (87.5:12.5, v/v) containing 0.0025 M tetrabutylammonium hydroxide. The absorbance of both TCN and TCN-P was monitored at 280 nm with a sensitivity limit of 10 ng/ml. The recovery was 54 +/- 6% and 51 +/- 8% (mean +/- S.D.) from plasma for TCN and TCN-P, respectively. Rapid enzymatic dephosphorylation of TCN-P in plasma and tissue samples was prevented by adding a large excess of adenosine 5'-monophosphate. The assay was used to determine plasma and tissue concentrations of TCN-P and TCN after administration of TCN-P to cancer patients in a Phase I clinical study. 相似文献
14.
15.
16.
Magdalena
tolcov Alexander Kaszonyi Milan Hronec Tibor Liptaj 《Journal of chromatography. A》1995,710(2):351-356
An isocratic, reversed-phase HPLC procedure was developed for the simultaneous determination of isopropyl-, tert.-butyl-, tert.-amyl-, cyclohexylbis(2-benzothiazolylsulfen)amides. Quantitation is performed on a C18 bonded-phase column (Separon SGX C18 5 μm) using N-dicyclohexyl-2-benzothiazolesulfenamide as internal standard followed by UV photodiode-array detection. The precision (n = 7) for all derivatives of alkylbis(2-benzothiazolylsulfen)amides is within 1.5%. Identification of the compounds also in the mixtures was done by NMR spectroscopy. 相似文献
17.
18.
Sensitive determination of melatonin by precolumn derivatization and reversed-phase high-performance liquid chromatography 总被引:2,自引:0,他引:2
Iinuma F Hamase K Matsubayashi S Takahashi M Watanabe M Zaitsu K 《Journal of chromatography. A》1999,835(1-2):67-72
A sensitive determination method for melatonin was developed. Melatonin was derivatized under alkaline conditions in the presence of hydrogen peroxide. The resultant fluorophore was excited at 247 nm and the emission wavelength was 384 nm. The Stokes shift was 137 nm, which was longer than that of melatonin itself (lambda ex 280 nm, lambda em 330 nm). The melatonin derivative was separated by reversed-phase HPLC in about 15 min and the calibration curve was linear from 500 amol to 5 pmol (r > 0.999) with the detection limit of 500 amol (S/N = 5). The sensitivity of this method was about ten times higher than that of previous methods. Both the day-to-day precision and within-day precision were about 5%, and the derivative of melatonin in the aqueous solution was stable for more than 10 days. This method was successfully applied to the determination of melatonin in rat pineal gland. 相似文献
19.
A sensitive high-performance liquid chromatographic assay was developed for the determination of tocainide enantiomers in plasma. Following extraction of tocainide from plasma, the enantiomers were derivatized with S-(+)-1-(1-naphthyl)ethylisocyanate. The resulting diastereomers were separated and quantified using normal-phase chromatography with fluorescence detection set at 220/345 nm (excitation/emission). The peaks, resolved with a resolution factor greater than 1.5, were free from interference. Linearity was established over the concentration range 0.25-10.0 mg/l for each enantiomer in plasma (r2 greater than 0.998). The inter-assay variability was less than 10% at all concentrations examined. The method can be used to determine the pharmacokinetics of tocainide enantiomers in man. 相似文献
20.
Normal-phase high-performance liquid chromatography has been used for separation of phenol and its monoderivatives. Multi-component mixtures of hexane (non-polar component) with butan-1-ol, chloroform, butyl bromide, butyl chloride or diethyl ether (polar additives) were used as selective eluents. Silica gel "Silasorb 600" with specific surface area of about 600 m(2)/g and average particle size of $ 10 mum was used as the sorbent. Phenol and the o-, m-, p-isomers of cresol were concentrated by extraction with n-butyl acetate from aqueous solutions. A method for determination of microamounts of phenols in aqueous solutions in the presence of 160-fold amounts of aromatic hydrocarbons has been developed. 相似文献