首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
A selective and sensitive gas chromatographic assay for hexaprazol, a new antiulcer drug, in human plasma and urine has been developed. The method involves liquid-liquid extraction and capillary gas chromatography with nitrogen-sensitive detection. The limit of quantitation of plasma hexaprazol is ca. 25 ng/ml. The assay procedure permits the measurement of the levels of the unchanged drug following its clinical administration to humans.  相似文献   

2.
A rapid, sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of cibenzoline (CipralanTM) in human plasma and urine. The assay involves the extraction of the compound into benzene from plasma or urine buffered to pH 11 and HPLC analysis of the residue dissolved in acetonitrile-phosphate buffer (0.015 mol/l, pH 6.0) (80:20). A 10-microns ion-exchange (sulfonate) column was used with acetonitrile-phosphate buffer (0.015 mol/l, pH 6.0) (80:20) as the mobile phase. UV detection at 214 nm was used for quantitation with the di-p-methyl analogue of cibenzoline as the internal standard. The recovery of cibenzoline in the assay ranged from 60 to 70% and was validated in human plasma and urine in the concentration range of 10-1000 ng/ml and 50-5000 ng/ml, respectively. A normal-phase HPLC assay was developed for the determination of the imidazole metabolite of cibenzoline. The assays were applied to the determination of plasma and urine concentrations of cibenzoline and trace amounts of its imidazole metabolite following oral administration of cibenzoline succinate to two human subjects.  相似文献   

3.
A sensitive and selective high-performance liquid chromatographic method for the determination of cabergoline in plasma and urine has been developed. After buffering plasma and urine samples, cabergoline was extracted with a methylene chloride-isooctane mixture, back-extracted into 0.1 M phosphoric acid, then analysed by reversed-phase high-performance liquid chromatography. Quantitation was achieved by electrochemical detection of the eluate. The linearity, precision and accuracy of the method were evaluated. No interference from the biological matrices (human plasma and urine) was observed. The assay was still inadequate in terms of sensitivity for the quantitation of cabergoline plasma concentrations after a single oral dose of 1 mg of the drug to humans, but was successfully used in the determination of the urinary excretion of the drug.  相似文献   

4.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of 8-chloro-6-(2-chlorophenyl)-4H-imidazo-[1,5-alpha]-[1,4]-benzodiazepine-3-carboxamide [I] and its 4-hydroxy metabolite, 8-chloro-6-(2-chlorophenyl)-4-hydroxy-4H-imidazo-[1,5-alpha] [1,4]-benzodiazepine-3-carboxamide [II] in whole blood, plasma or urine. The assay for both compounds involves extraction into diethyl ether-methylene chloride (70:30) from blood, plasma, or urine buffered to pH 9.0. The overall recoveries of [I] and [II] are 92.0 +/- 5.4% (S.D.) and 90.3 +/- 4.9% (S.D.), respectively. The sensitivity limit of detection is 50 ng/ml of blood, plasma, or urine using a UV detector at 254 nm. The HPLC assay was used to monitor the blood concentration-time fall-off profiles, and urinary excretion profiles in the dog following single 1 mg/kg intravenous and 5 mg/kg oral doses, and following multiple oral doses of 100 mg/kg/day of compound [I].  相似文献   

5.
A gas chromatographic method for the quantitative determination of the alpha, beta-adrenoceptor blocker YM-09538 in urine is described. YM-09538 was extracted from alkalinized urine with ethyl acetate and converted to its cyclic methylboronate derivative. Analysis by gas chromatography using a nitrogen-sensitive detector allowed quantitation of the drug over a concentration range of 0.2-5.0 micrograms/ml. Urinary excretion of YM-09538 was determined in humans after oral administration of 50 mg.  相似文献   

6.
A simple, sensitive and specific assay was developed for the determination in plasma and urine of 6-(2'-chlorophenyl)-4-hydroxy-4H-imidazo[1,5-alpha] [1,4]benzodiazepine- 3-carboxamide, compound I, a mixed agonist-antagonist anxiolytic agent. A hexadeuterated analogue of the compound was added to plasma or urine as the reference standard. The titled compound was extracted with benzene at pH 11. Following evaporation of the solvent, the residue was reacted with pentafluoropropionic anhydride in the presence of triethylamine. The derivatizing reagents were evaporated, and the carbonitrile derivative of the analyte was extracted into ethyl acetate at pH 11. The residue remaining after removal of the ethyl acetate was silylated with bis(trimethylsilyl)trifluoroacetamide, and a portion of this solution was analyzed by gas chromatography-negative-ion chemical-ionization mass spectrometry. The mass spectrometer was set to monitor, in the gas chromatographic effluent, the M-. ion of the titled compound and its hexadeuterated reference standard. The ratio of these two ions was calculated and converted to a concentration of analyte using a calibration curve that was generated from the analyses of control plasma fortified with various amounts of analyte and a fixed amount of the hexadeuterated reference standard. The limit of quantitation of the assay was 1 ng/ml for plasma and urine.  相似文献   

7.
A stereospecific high-performance liquid chromatographic method for the quantification of (-)- and (+)-tertatolol in plasma and urine is described. The method involves solid-phase extraction followed by derivatization with S(+)-naphthylethylisocyanate to form the urea derivative, which is more sensitive to fluorescence detection. The separation of the diastereomeric derivatives was performed by reversed-phase high-performance liquid chromatography. Fluorimetric detection (lambda excitation = 220 nm, lambda emission = 320 nm) allows the quantification of tertatolol enantiomers down to 6 ng/ml. The assay was used to study the pharmacokinetic profile of tertatolol enantiomers following oral administration of racemic tertatolol; preliminary results suggest enantioselective absorption and/or disposition of tertatolol.  相似文献   

8.
A single high-performance liquid chromatographic (HPLC) assay for the quantitative determination of dilevalol, the R,R isomer of labetalol, was developed for both plasma and urine. A significantly improved limit of detection for dilevalol in plasma was accomplished by extensive modification of an HPLC assay originally developed in our laboratory for labetalol. This simplified method is readily adaptable to urine and represents the first reported HPLC assay for the quantitative determination of dilevalol in this biofluid. Drug was recovered from plasma or urine by partition into diethyl ether under mildly alkaline conditions and back-extraction into dilute acid. Reversed-phase separation of dilevalol and the internal standard was accomplished on a 150 X 4.1 mm column commercially packed with a spherical (5 micron) macroporous copolymer (PRP-1). No interferences were observed in extracts obtained from drug-free plasma or urine. Selectivity for dilevalol in the presence of other beta-blockers was established. This method demonstrated a linear detector response to concentrations of unchanged drug typically observed in urine and plasma following once-a-day treatment with dilevalol hydrochloride (100-800 mg). The lowest limit of reliable quantitation was established at 1 ng/ml in plasma. The intra-assay precision (coefficient of variation) remained less than 6% at all concentrations evaluated from 1 to 800 ng/ml. In urine, the lowest limit of quantitation was validated to 20 ng/ml where the intra-assay precision (coefficient of variation) for unchanged drug was less than 4% at all concentrations evaluated up to 400 ng/ml. This method is suitable for routine quantitation of unchanged drug in human plasma and urine following the administration of therapeutically effective doses of dilevalol hydrochloride.  相似文献   

9.
A sensitive gas chromatographic method for quantitative analysis of ketamine and norketamine in human and animal biological fluids is described. The nitrogen-sensitive detection procedure used is more stable than electron-capture detection and reduced analysis time. The method used bromo-ketamine as an internal standard for quantitation and is linear from 10-25,000 ng/ml. No interferences were shown with drugs commonly associated with cardiac surgery with cardiopulmonary by-pass. This assay is sensitive, specific, using either native or derivatized drugs and can be used for routine analysis of ketamine and norketamine in plasma or urine.  相似文献   

10.
Sensitive and enantioselective gas chromatographic assays have been developed and applied to the quantitation in human urine of the enantiomers of methoxyphenamine and its three primary oxidative metabolites, namely, N-desmethylmethoxyphenamine, O-desmethylmethoxyphenamine and 5-hydroxymethoxyphenamine. The separation of the various analytes was achieved through the combined use of high-resolution gas chromatography coupled with electron-capture detection and employing a capillary OV-225 column. The formation of diastereometric derivatives involved the chiral acylating reagent N-heptafluorobutyryl-L-prolyl chloride. The assays for methoxyphenamine and O-desmethylmethoxyphenamine were linear over the range 0.25-2.0 micrograms/ml for each analytes' enantiomers, while in the case of the enantiomers for N-desmethylmethoxyphenamine and 5-hydroxymethoxyphenamine linearity was shown over the ranges 0.094-0.75 and 0.188-1.5 micrograms/ml, respectively. The mean coefficients of variation in all cases were less than 4%.  相似文献   

11.
A rapid, sensitive and specific high-performance liquid chromatographic (HPLC) assay was developed for the determination of amdinocillin (formerly mecillinam) in human plasma and urine. The assay is performed by direct injection of a plasma protein-free supernatant or a dilution of urine. A 10 micrometer muBondapak phenyl column with an eluting solvent of water--methanol--1 M phosphate buffer, pH 7 (70:30:0.5) was used, with UV detection of the effluent at 220 nm. Azidocillin potassium salt [potassium-6-(D-(-)-alpha-azidophenyacetamido)-penicillanate] was used as the internal standard and quantitation was based on peak height ratio of amdinocillin to that of the internal standard. The assay has a recovery of 74.4 +/- 6.3% (S.D.) in the concentration ranges of 0.1-20 microgram per 0.2 ml of plasma with a limit of detection equivalent to 0.5 microgram/ml plasma. The urine assay was validated over a concentration range of 0.025-5 mg/ml of urine, and has a limit of detection of 0.025 mg/ml (25 microgram/ml) using a 0.1-ml urine specimen per assay. The assay was applied to the determination of plasma and urine concentrations of amdinocillin following intravenous administration of a 10 mg/kg dose of amdinocillin to two human subjects. The HPLC and microbiological assays were shown to correlate well for these samples.  相似文献   

12.
A sensitive gas chromatographic assay for the simultaneous determination of brofaromine [4-(7-bromo-5-methoxy-2-benzofuranyl)piperidine hydrochloride], a new monoamine oxidase-A inhibitor, and its major metabolite was developed and validated. After addition of 4-(5-bromo-2-benzofuranyl)piperidine as internal standard, the compounds were isolated from biological fluids by liquid-liquid extraction at basic pH. After derivatization with heptafluorobutyric anhydride the compounds were chromatographed using a packed column (OV-17) and an electron-capture detector. The limit of quantitation was ca. 0.03 nmol per sample (10 ng) for both compounds. analysis of spiked samples demonstrated the good accuracy and precision of the method, which is suitable for use in pharmacokinetic and bioavailability studies. The method was applied to samples from an experiment in a healthy volunteer treated with a single oral dose of 75 mg of brofaromine hydrochloride. Plasma profiles before and after enzymic hydrolysis showed that about one-third of the total brofaromine in plasma and practically all of the major metabolite (O-desmethylbrofaromine) were present in the conjugated form.  相似文献   

13.
A high-performance liquid chromatographic method for the determination of R- and S-prenylamine in human plasma and urine is described. It involves a two-step liquid-liquid extraction of prenylamine from biological material and preparation of diastereomeric urea derivatives with R-(-)-naphthylethyl isocyanate, a chiral fluorescence marker. Separation and quantitation of the diastereomeric prenylamine derivatives are carried out by a reversed-phase high-performance liquid chromatographic system with fluorimetric detection. The limit of determination is less than 2 ng of enantiomer per ml of urine and less than 1 ng of enantiomer per ml of plasma. A preliminary kinetic study on one healthy volunteer who had received a single oral dose of racemic prenylamine (100-mg film tablet) showed distinctly higher plasma and urine concentrations of the R-enantiomer.  相似文献   

14.
A reversed-phase ion-pair high-performance liquid chromatographic assay is described for the rapid and sensitive quantitation of the H2-receptor antagonist ranitidine in human plasma and urine. The method involves a single-step extraction of the alkalinized sample with methylene chloride and analysis of the evaporated extract on a cyano column. Detection was performed by ultraviolet absorbance monitored at 318 nm. The overall run time of the assay was 5 min at a flow-rate of 2.0 ml/min. The limit of sensitivity was 1 ng/ml ranitidine in human plasma. Urine and plasma samples collected from a subject after administration of an oral dose of 150 mg of ranitidine were analyzed by this method. Furthermore, the procedure was applied to determine the red blood cell partition coefficient of ranitidine in a concentration range up to 10 micrograms/ml.  相似文献   

15.
A sensitive, efficient, linear and reproducible capillary gas chromatographic method with electron-capture detection was developed for the quantitation of nifedipine and its primary metabolite M-I in plasma together with the urinary and principal metabolites M-II and M-III. On-column, rather than split-splitless, injection was employed to obviate oxidative degradation of nifedipine to M-I. The photosensitivity of nifedipine was re-examined under laboratory conditions and nifedipine was found to have a half-life in excess of two days when amber glassware and darkroom manipulations under red light were used. The method can determine nifedipine and its metabolites in plasma and urine after a single oral dose of 5 mg and can be applied to measure M-I production by human liver microsomes.  相似文献   

16.
An enantioselective high-performance liquid chromatographic assay for the quantitation of the enantiomers of ketamine and its major metabolite norketamine in human plasma is described (assay I). The procedure involved extraction of the compounds from alkalized plasma into cyclohexane. Stereoselective separation was achieved with a prepacked alpha 1-acid glycoprotein column without any derivatization procedure. A second assay using a conventional reversed-phase column to determine total (racemic) ketamine and norketamine is also described. Because of interfering plasma peaks (assay II) the cyclohexane solution was reextracted into 1 M hydrochloric acid. The detection wavelength was 215 nm for all substances. The limit of quantification of the method was ca. 40 ng/ml in plasma. The assays were sensitive and reproducible. The method was demonstrated to be sensitive for stereoselective pharmacokinetic studies of ketamine after clinical doses.  相似文献   

17.
A gradient elution high-performance liquid chromatographic method is described for the analysis of the beta-lactamase inhibitor tazobactam (YTR-830H) and a semi-synthetic parenteral penicillin, piperacillin, in human plasma, serum, bile and urine. The assay for plasma, serum and bile involves deproteinization with acetonitrile and the removal of lipids with dichloromethane; urine is diluted with buffer. Separation and quantitation are achieved using a mobile phase based on ion-suppression chromatography on a C18 reversed-phase column with ultraviolet detection at 220 nm. The limit of quantitation for both compounds is 1.0 microgram/ml in plasma, serum and bile using a 0.2-ml sample and 50.0 micrograms/ml in urine using a 0.1-ml sample. The method has been validated by preparing and analyzing a series of fortified samples (range 1.0-200 micrograms/ml for each compound in plasma, serum and bile and 50.0-10,000 micrograms/ml for each compound in urine). Excellent linearity, accuracy, precision and recovery were obtained. The method was not interfered with by other endogenous components, nor by other commonly administered antibiotics such as amoxicillin, mezlocillin, cefometazole and cefotaxime. The assay has been successfully applied to the analysis of samples from pharmacokinetic studies in man and animals.  相似文献   

18.
A rapid, sensitive, and specific high performance liquid chromatographic (HPLC) assay was developed for the determination of 2-methoxy-11-oxo-11H-pyrido-[2,1-b]quinazoline-8-carboxylic acid (I) from biological fluids. The overall recovery from blood and plasma is 69 +/- 10% (S.D.) and 84 +/- 6% (S.D.), respectively, and the sensitivity limit of quantitation is 100 ng/ml by UV absorption and 5 ng/ml by fluorescence detection using a 1 ml specimen. The assay was used in the determination of blood levels of compound in the Rhesus monkey following intravenous administration of a 10 mg/kg dose, and of blood and urine levels of compound I in a dog following intravenous and oral administration of a 1 mg/kg dose.  相似文献   

19.
A high-performance liquid chromatographic method for the analysis of 1-ethyl-1,4-dihydro-4-oxo-1,8-naphthyridine-3,7-dicarboxylic acid (I) in plasma and urine is described. A statistical evaluation of the assay technique has shown acceptable accuracy and precision at concentrations as high as 2.0 microgram/ml of plasma or 29.0 microgram/ml of urine for samples augmented with 1. As little as 0.08 microgram/ml of I in plasma or 0.42 microgram/ml of I in urine were quantitatively determined. The mean relative error for the assay of unknown concentrations of I in plasma and urine was +/- 8% and +/- 3%, respectively. This method was used for the analysis of I in the plasma and urine of rhesus monkeys following oral administration of 200 mg/kg of nalidixic acid.  相似文献   

20.
A sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of tibenelast, 5,6-diethoxybenzo[b]thiophene-2- carboxylic acid, in plasma and urine. The plasma assay involves protein precipitation with 4% trichloroacetic acid, while the urine assay is an automated solid-phase extraction procedure that utilizes the Waters Millilab workstation. The analysis was achieved by reversed-phase HPLC with ultraviolet detection at 313 nm. The quantitation limit of the assay was 50 ng/ml in plasma and 100 ng/ml in urine. The intra-day coefficient of variation for the plasma analysis was between 2.2 and 8.4%, while the overall inter-day coefficient of variation was 5.5 and 6.0% for the high and low calibration curves, respectively. The intra-day coefficient of variation for the urine analysis was between 0.3 and 3.0%, while the inter-day coefficient of variation was 2.1% for both the low and high validation samples. The assay methodology has been used in the evaluation of samples from pharmacokinetic and clinical safety studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号