首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A procedure was developed for determining water-soluble vitamins B and vitamin C in premixes, biologically active supplements, and combined feed by reversed-phase HPLC using sodium heptanesulfonate as an ion-pair reagent. A procedure was proposed for purifying a combined food extract by solid-phase extraction on a column packed with a Sep-Pak C18 adsorbent. The stability of ascorbic acid and riboflavin in aqueous solutions with different pH values was studied.  相似文献   

2.
A collaborative study was conducted on an inhibition-based protein-binding assay using the Biacore Q biosensor instrument and the Biacore Qflex Kit Vitamin B12 PI. The samples studied included infant formula, cereals, premixes, vitamin tablets, dietary supplements, and baby food. The collaborative study, which involved 11 laboratories, demonstrated that the assay showed an RSDr of 1.59-27.8 and HorRat values for reproducibility of 0.34-1.89 in samples with levels ranging from ppm to ppb. The assay studied is a label-free protein binding-based assay that uses the principle of surface plasmon resonance (SPR) to measure the interaction between vitamin B12 and a specific binding protein. A Biacore Q biosensor uses this principle to detect binding directly at the surface of a sensor chip with a hydrophilic gold-dextran surface. The instrument passes a mixture of prepared sample extract and binding protein solution across a covalently immobilized vitamin B12 chip surface, and the response is given as free-binding protein as the mixture binds to the immobilized surface. This technique uses the specificity and robustness of the protein-ligand interaction to allow minimal sample preparation and a wide range of matrixes to be analyzed rapidly. The reagents and accessories needed to perform this assay are provided as the ready-to-use format "Qflex Kit Vitamin B12 PI." The method is intended for routine use in the quantitative determination of vitamin B12 (as cyanocobalamin) in a wide range of food products, dietary vitamin supplements, and multivitamin premixes.  相似文献   

3.
Water-soluble vitamins include the B-group vitamins and vitamin C. In order to correctly monitor water-soluble vitamin content in fortified foods for compliance monitoring as well as to establish accurate data banks, an accurate and precise analytical method is a prerequisite. For many years microbiological assays have been used for analysis of B vitamins. However they are no longer considered to be the gold standard in vitamins analysis as many studies have shown up their deficiencies. This review describes the current status of analytical methods, including microbiological assays and spectrophotometric, biosensor and chromatographic techniques. In particular it describes the current status of the official methods and highlights some new developments in chromatographic procedures and detection methods. An overview is made of multivitamin extractions and analyses for foods and supplements.  相似文献   

4.
Nine water-soluble vitamins: [thiamine (B1), ascorbic acid (C), nicotinamide (PP), pyridoxine (B6), calcium pantothenate (B5), folic acid (B9), cyanocobalamin (B12), riboflavin (B2) and biotin (B8)] were separated on a YMC-Pack Pro C18 column (250 mm x 4.6 mm, 5 microm particle size) in a single run with a gradient elution of mobile phase consisting of 0.025% trifluoroacetic acid pH 2.6 (solvent A) and acetonitrile (solvent B). The separation was achieved within 17 min with a flow rate of 0.8 ml min(-1) and the detection was performed at two wavelengths (210 and 275 nm). The calibration graphs plotted with six concentrations of each vitamin were linear with a regression coefficient R2 > 0.995. The method was applied for the quantification of vitamins B1, C, PP, B6, B5, B9 B2 and B8 in polyvitaminated premixes (premixes) used for the fortification of infant nutrition products. The sample preparation involves an aqueous extraction of vitamins and two different samples dilution were used prior the LC-analysis. The specificity of the method was demonstrated by the retention characteristics, UV spectra and by comparing the peak purity with the standard of each vitamin. The repeatability of the method was evaluated at different level of concentrations on 12 premixes and the coefficients of variation (CVr) were below 6.5%. The values of the intermediate precision (CV1) were below 9.6% (n = 6). The concentrations of vitamins found in premixes with our method were comparable to the declared values, since no bias was found between the two sets of results at 95% confidence. The simplicity of the procedure should make it highly desirable for quality control of premixes in the food industry.  相似文献   

5.
The content and composition of dietary supplements is of great interest due to their increasing consumption and variety of available brand offered in the market. Accurate determination of vitamins is important for the improvement of dietary supplement quality and nutrition assessments. In this regard, the simultaneous determination of vitamin D3 (calcitriol—CT and cholecalciferol—CHL) and K2 (menaquinone-4—MK-4 and menaquinone-7—MK-7) in dietary supplements was developed by using ultra-high-pressure liquid chromatography (UHPLC). The overall runtime per sample was above 35 min, with the retention times of 2.40, 6.59, 7.06, and 32.6 min for vitamin D3 (CT and CHL) and vitamin K2 (MK-4 and MK-7), respectively. The limits of detection and limits of quantification for the target nutritional compounds ranged between 0.04–0.05 µg/mL, respectively. The validation results indicated that the method had reasonable linearity (R2 ≥ 0.9990), good recovery (>82%), satisfactory intra-day precision (≤1.9%) and inter-day precision (≤3.5%), and high selectivity and specificity. The validated UHPLC method was demonstrated to be precise, accurate, and robust for the simultaneous determination of vitamins D3 (CT and CHL) and K2 (MK-4 and MK-7) in dietary supplements.  相似文献   

6.
A method was developed and validated for the determination of total iodine in a wide variety of food products and dietary supplements. The method involves a unique sample digestion with a KOH solution in an oven or by using an open-vessel microwave system. After digestion, a stabilizer is added and the solution is taken to volume, then filtered and analyzed either directly or after dilution. The amount of iodine is determined with inductively coupled plasma-mass spectrometry (ICP-MS). The method was validated by experiments to determine its precision, accuracy, linearity, specificity, ruggedness, and robustness. The LOQ of this method is 25-50 microg/kg. The method demonstrated an average RSD of 2.27% during analysis of milk powder and 4.30% during analysis of a dietary supplement tablet reference material. The accuracy of the method as determined with these same reference materials was 100 and 94.2%, respectively. The method has been used successfully on commodity foods, processed foods, dairy products, pet food, infant formula, animal feed, mineral premixes, and a variety of dietary supplements.  相似文献   

7.
In recent years, the National Institute of Standards and Technology (NIST) has developed several food-matrix Standard Reference Materials (SRMs) characterized for vitamins and other organic nutrients. NIST uses several "modes" for assignment of analyte concentrations in SRMs, one of which includes the use of data provided by collaborating laboratories. Certification modes and liquid chromatographic methods that were used by NIST for value assignment of vitamin concentrations in recently introduced food-matrix SRMs are described in this paper. These materials and methods include vitamins D and E in coconut oil (SRM 1563) by gravimetry and multi-dimensional liquid chromatography (LC); vitamins A, E, and several B vitamins by reversed-phase LC and vitamin C by ion-exchange chromatography in infant formula (SRM 1846); and carotenoids and vitamins A and E by reversed-phase liquid chromatography in a baby food composite (SRM 2383).  相似文献   

8.
Several liquid chromatography (LC) methods for analysis of vitamin A in foods and feeds have been previously reported but only a few have been applied in non-food matrixes. A validated LC method is needed for determination of vitamin A and beta-carotene in the various matrixes presented by dietary supplements. The performance of a reversed-phase method with methanol-isopropanol gradient elution was evaluated with standard retinyl derivatives and beta-carotene. The reversed-phase method is capable of separating retinol from other derivatives such as retinyl acetate, retinyl palmitate, and beta-carotene. Two types of extraction were used to extract the analytes from the dietary supplements: a hexane-methylene chloride extraction for soft-gel capsules containing beta-carotene, and a direct solvent extraction for dietary supplements in tablet form. The direct solvent extraction consisted of treatment with ethanol and methylene chloride following addition of hot water (55 degrees C). Results with the reversed-phase method for vitamin A and beta-carotene in the products examined (n = 8) indicated excellent method performance. The main form of vitamin A or beta-carotene in dietary supplements was the all-trans isomer. The reversed-phase method avoids saponification and is rapid, accurate, precise, and suitable for simultaneous determination of retinyl derivatives and beta-carotene in dietary supplements.  相似文献   

9.
The preparation of the recently released Standard Reference Material (SRM) 2383 Baby Food Composite and the process used for value assignment of nutrient concentrations are reported. SRM 2383 can be used as a control material when assigning values to in-house control materials and when validating analytical methods for measuring proximates, vitamins, and minerals in baby food and similar matrixes. The SRM was prepared as a commercial baby food would be prepared, with the same ingredients. The Certificate of Analysis for SRM 2383 provides assigned values for concentrations of proximates, vitamins, and minerals for which product labeling is required by the Nutrition Labeling and Education Act of 1990. These assigned values were based on measurements by the National Institute of Standards and Technology (NIST) and/or collaborating laboratories. Assignment of analyte concentrations based solely on analyses by collaborating laboratories is described in this paper. Certified values are provided for retinol, tocopherols, and several carotenoids including total beta-carotene; the certification of and methodology used for measurement of these analytes is discussed in a companion paper (this issue, page 288). Reference values are provided for solids, ash, fat, nitrogen, protein, carbohydrate, calories, vitamin B1, vitamin B2, vitamin B6, niacin, biotin, calcium, phosphorus, magnesium, manganese, iron, zinc, copper, sodium, potassium, and chloride. Reference values for additional carotenoids are reported in the companion paper (this issue, page 288). Information values are provided for iodine, selenium, molybdenum, vitamin D, vitamin B12, folic acid, pantothenic acid, choline, inositol, sugars, total dietary fiber, and 3 classes of fats.  相似文献   

10.
Assessing dietary intake of vitamins from all sources, including foods, dietary supplements, and fortified foods, would be aided considerably by having analytical methodologies that are capable of simultaneous determination of several vitamins. Vitamins naturally present in foods may occur in different chemical forms, with levels ranging over several orders of magnitude. Vitamins in dietary supplements and fortified foods, however, are typically added in a single chemical form, and matrix issues are usually not as complex. These sources should thus be relatively amenable to approaches that aim for simultaneous determination of multiple vitamins. Our recent work has focused on development of liquid chromatography (LC)–UV/fluorescence and LC–tandem mass spectrometry methods for the simultaneous determination of water-soluble vitamins (thiamine, niacin, pyridoxine, pantothenic acid, folic acid, biotin, and riboflavin) in dietary supplement tablets and fortified foods, such as formula powders and breakfast cereals. As part of the validation of our methods and collaboration in characterization of a new NIST SRM 1849 Infant/Adult Nutritional Formula powder, we report data on SRM 1849 using isotope dilution mass spectrometric methods. Use of available NIST Standard Reference Materials® as test matrices in our method development and validation gives a benchmark for future application of these methods. We compare three chromatographic approaches and provide data on stability of vitamin standard solutions for LC-based multiple vitamin determinations.
Figure
Extracted ion chromatograms of seven vitamins using RP chromatography treatment  相似文献   

11.
There is increased interest in accurately assessing the total dietary intake of vitamins from all sources, including foods and dietary supplements. Consequently, a Dietary Supplement Ingredient Database (DSID), based upon analytical values, is being established by USDA with support of the Office of Dietary Supplements (ODS), NIH. The DSID necessitated the development of a new SRM, 3280 — Multivitamin/Multimineral Tablets, by the National Institute of Standards and Technology (NIST), with support from the ODS. As a continuation of a long-term project to develop and validate new methods of determining water-soluble B vitamins in foods and dietary supplements, and as part of a collaborative effort with NIST to characterize SRM 3280, values for the vitamin contents of SRM 3280 have been generated by a liquid chromatographic isotope dilution mass spectrometric (LC/IDMS) method. Isotope-labeled (13C and/or 2H) B vitamins (B1-thiamine, B6-pyridoxine, B3-nicotinamide, and B5-pantothenic acid) were obtained from commercial sources, with the support of the ODS/NIH. Our LC/IDMS method uses a C18 reversed phase column, an Agilent 1100 HPLC system, and a Quattro Micro triple-quad mass spectrometer (MS). B vitamin determination was achieved using a gradient LC profile combined with MS/MS detection in multiple reaction monitoring mode. Stock solutions of the isotope-labeled vitamins were calibrated against USP standard solutions. The SRM tablets, with added amounts of the four isotope-labeled B vitamins, were extracted and the vitamins simultaneously determined in a single LC run, in contrast with the single-component determinations performed via IDMS. Unknown vitamin concentrations were calculated by comparing the ratios of the integrated LC peaks at the different masses of the unlabeled and labeled vitamins.  相似文献   

12.
At the "Standards Development and International Harmonization: AOAC INTERNATIONAL Mid-Year Meeting" on June 29, 2011, an Expert Review Panel (ERP) agreed to further examine AOAC Official Method 2011.01, "Determination of Vitamin B12 by Surface Plasmon Resonance," for use with infant formula and adult nutritionals. The original collaborative study was conducted using the Biacore Q biosensor instrument and the Biacore Q Qflex Kit Vitamin B12 PI. Samples included in the study were infant formula, cereals, premixes, vitamin tablets, dietary supplements, and baby food. Eleven laboratories participated in the collaborative study. The results demonstrated a repeatability RSD (RSDr) of 1.59-27.8 and HorRat values for reproducibility of 0.34-1.89 in samples with levels ranging from ppm to ppb. The assay studied is a label-free protein binding-based assay that uses the principle of surface plasmon resonance to measure the interaction between vitamin B12 and a specific binding protein by passing a portion of the prepared sample extract combined with binding protein solution across a functionalized sensor chip. The response from the functionalized sensor chip is given as free-binding protein, as the mixture binds to the prepared surface of the chip. The ready-to-use Qflex Kit Vitamin B12 PI provides the reagents and accessories necessary to perform this assay. AOAC Method 2011.01 was approved by the AOAC Method Committee on Food Nutrition for Official First Action status, applicable to a wide range of food products, dietary supplements, and multivitamin premixes. After evaluation of the validation data available, an ERP agreed in June 2011 that the method meets standard method performance requirements, as articulated by the Stakeholder Panel on Infant Formula and Adult Nutritionals. The ERP granted the method First Action status, applicable to infant formula and adult/pediatric nutritional formula.  相似文献   

13.
Vitamin D plays a crucial and very well-known role in regulation of calcium homeostasis and bone metabolism and mineralization. However, a huge and more recent body of evidence supports the positive influence of vitamin D on the regulation of immune response, ranging from protection against respiratory tract infections to prevention and management of asthma. Nevertheless, vitamin D deficiency is a very common condition and there is an increasing need for suitable products for proper supplementation, allowing good compliance also in specific populations. Orally disintegrating tablets (ODT) were first developed to overcome the difficulty experienced by pediatric and geriatric patients of swallowing traditional oral dosage forms and, recently, orodispersible films (ODF) are gaining popularity as novel dosage form for assuming active pharmaceutical ingredients, vitamins, and ingredients for food supplements. This study describes a 2000 IU Vitamin D3 ODF for daily intake, consisting of hydrophilic polymers and suitable excipients, manufactured by film-casting process. Elongation-at-break (E%), Young’s modulus (Y), and tensile strength (TS) were investigated using a dynamometer. Chemical stability was evaluated assaying the vitamin D3 in the films stored at different environmental conditions. In addition, in vitro disintegration and dissolution studies were performed. Correlation existed between the mechanical properties of the film and the residual water, acting as plasticizer. The stability study showed that vitamin D3 assay was ≥90% also after 3 months at 40 °C. The film disintegrated in less than 1 min and the vitamin D3 released was ≥75% after 15 min. An ODF with suitable properties can be manufactured and used as innovative dosage form for vitamin D3 food supplements.  相似文献   

14.
Simultaneous Determination of Vitamins.--Klejdus et al. described a simultaneous determination of 10 water- and 10 fat-soluble vitamins in pharmaceutical preparations by liquid chromatography-diode-array detection (LC-DAD). A combined isocratic and linear gradient allowed separation of vitamins in 3 distinct groups: polar, low-polar, and nonpolar. The method was applied to pharmaceutical preparations, fortified powdered drinks, and food samples, for which results were in good agreement with values claimed. Heudi et al. described a separation of 9 water-soluble vitamins by LC-UV. The method was applied for the quantification of vitamins in polyvitaminated premixes used for the fortification of infant nutrition products. The repeatability of the method was evaluated at different concentration levels and coefficients of variation were <6.5%. The concentrations of vitamins found in premixes with the method were comparable to the values declared. A disadvantage of the methods mentioned above is that sample composition has to be known in advance. According to European legislation, for example, foods might be fortified with riboflavin phosphate or thiamin phosphate, vitamers which are not included in the simultaneous separations described. Vitamin B2.--Vi?as et al. elaborated an LC analysis of riboflavin vitamers in foods. Vitamin B2 can be found in nature as the free riboflavin, but in most biological materials it occurs predominantly in the form of 2 coenzymes, flavin mononucleotide (FMN) and flavin-adenine dinucleotide (FAD). Several methods usually involve the conversion of these coenzymes into free riboflavin before quantification of total riboflavin. According to the authors, there is growing interest to know flavin composition of foods. The described method separates the individual vitamers isocratically. Accuracy of the method is tested with 2 certified reference materials (CRMs). Vitamin B5.-Methods for the determination of vitamin B5 in foods are limited because of their low sensitivity and poor selectivity. Pakin et al. proposed a post-column derivatization of pantothenic acid as a fluorescent compound and used this principle in a specific and sensitive method for the determination of free and bound pantothenic acid in a large variety of foods. A French laboratory invited European laboratories to participate in a series of collaborative studies for this method, which will be carried out in 2005/2006. A more sophisticated method was described by Mittermayer et al. They developed an LC-mass spectrometry (LC/MS) method for the determination of vitamin B5 in a wide range of fortified food products. Application of the method to various samples showed consistent results with those obtained by microbiology. Vitamin B6.-Method 2004.07, an LC method for the analysis of vitamin B6 in reconstituted infant formula, was published by Mann et al. In contrast with this method, which quantifies vitamin B6 after converting the phosphorylated and free vitamers into pyridoxine, Vi?as et al. published an LC method which determines 6 vitamin B6 related compounds, the 3 B6 vitamers, their corresponding phosphorylated esters, and a metabolite. Accuracy was determined using 2 CRMs. Results were within the certified ranges. Vitamin C.-Franke et al. described an extensive study to vitamin C and flavonoid levels of fruits and vegetables consumed in Hawaii. Vitamin C was determined by measuring ascorbic acid in its reduced state by LC and coulometric detection along with UV absorbance detection at 245 nm. No attempts were made to assess levels of dehydroascorbic acid. Most recent research revealed that cell uptake of dehydroascorbic acid is unlikely to play a major role, which may explain the very low vitamin C activity of orally administered L-dehydroascorbic acid in rats. The food levels found by Franke et al. are variably lower, higher, or equal in comparison to other studies. Iwase described a method for the determination of ascorbic acid in foods using L-methionine for the pre-analysis sample stabilization. Electrochemical detection was used for the quantification. Traditionally, metaphosphoric acid was proven to be a useful dissolving agent for the determination of ascorbic acid. However, it dissolves in water very slowly, it is hygroscopic, and accurate weighing is not easy. Adjustment at pH 2-3 takes a long time. It appeared to be possible to replace metaphosphoric acid by 0.2% phosphoric acid. Methionine played an important role on the stability of ascorbic acid. The method seemed to be applicable to the routine analysis of ascorbic acid in foods. Folic Acid.-Microbiological analysis of total folate in foods is often considered as the golden standard compared to other methods based on, for example, LC. Koontz et al. showed results of total folate concentrations measured by microbiological assay in a variety of foods. Samples were submitted in a routine manner to experienced laboratories that regularly perform folate analysis fee-for-service basis in the United States. Each laboratory reported the use of a microbiological method similar to the AOAC Official Method for the determination of folic acid. Striking was, the use of 3 different pH extraction conditions by 4 laboratories. Only one laboratory reported using a tri-enzyme extraction. Results were evaluated. Results for folic acid fortified foods had considerably lower between-laboratory variation, 9-11%, versus >45% for other foods. Mean total folate ranged from 14 to 279 microg/100 g for a mixed vegetable reference material, from 5 to 70 microg/100 g for strawberries, and from 28 to 81 microg/100 g for wholemeal flour. One should realize a large variation in results, which might be caused by slight modifications in the microbiological analysis of total folate in foods or the analysis in various (unfortified) food matrixes. Furthermore, optimal combination of enzymes and reaction conditions may vary depending on the composition of the food. Padrangi and Laborde showed recently that treatment with alpha-amylase had no significant effect on measured folate in spinach, although addition of protease significantly increased the release of folate. LC/MS applications gain increasing attention because of their specificity. Rychlik used stable isotope dilution assays for the determination of the folate content of broccoli and bread. Compared to data in the literature and food data bases, amounts were significantly lower. Pawlosky et al., however, found comparable values for 5-methyltetrahydrofolic acid and folic acid by HPLC analysis with fluorescent detection and HPLC/MS. Among samples analyzed were CRMs and broccoli. Besides folic acid, other water-soluble vitamins were also determined by LC/MS/MS by Leporati et al. The method was applied to the quantitative analysis of the natural content of vitamins in typical Italian pasta samples, as well as in fortified pasta samples produced for the U.S. market. Biotin.-A paper from Staggs et al. included the assertion that existing biotin data in food composition tables are inaccurate because the majority are based on bioassays with all relevant disadvantages. Data in most cases are overestimated with consequences for recommendations for dietary biotin intake. An HPLC/avidin-binding assay was used to analyze 87 foods to support the hypothesis mentioned.  相似文献   

15.
Introduction: Alpha-galactosidase (α-Gal) is an enzyme responsible for the hydrolyzation of glycolipids and glycoprotein commonly found in dietary sources. More than 20% of the general population suffers from abdominal pain or discomfort caused by intestinal gas and by indigested or partially digested food residuals. Therefore, α-Gal is used in dietary supplements to reduce intestinal gases and help complex food digestion. Marketed enzyme-containing dietary supplements must be produced in accordance with the Food and Drug Administration (FDA) regulations for Current Good Manufacturing Practice (cGMPs). Aim: in this work we illustrated the process used to develop and validate a spectrophotometric enzymatic assay for α-Gal activity quantification in dietary supplements. Methods: The validation workflow included an initial statistical-phase optimization of materials, reagents, and conditions, and subsequently a comparative study with another fluorimetric assay. A final validation of method performance in terms of specificity, linearity, accuracy, intermediate-precision repeatability, and system precision was then executed. Results and conclusions: The proven method achieved good performance in the quantitative determination of α-Gal activity in commercial food supplements in accordance with the International Council for Harmonisation of Technical Requirements for Pharmaceuticals (ICH) guidelines and is suitable as a rapid in-house quality control test.  相似文献   

16.
X-ray powder diffraction (XRPD) and thermal analysis (differential scanning calorimetry/derivative of thermogravimetry (DSC/DTG)) are solid-state techniques that can be successfully used to identify and quantify various chemical compounds in polycrystalline mixtures, such as dietary supplements or drugs. In this work, 31 dietary supplements available on the Polish market that contain iron compounds, namely iron gluconate, fumarate, bisglycinate, citrate and pyrophosphate, were evaluated. The aim of the work was to identify iron compounds declared by the manufacturer as food supplements and to try to verify compliance with the manufacturer’s claims. Studies performed by X-ray and thermal analysis confirmed that crystalline iron compounds (iron (II) gluconate, iron (II) fumarate), declared by the manufacturers, were present in the investigated dietary supplements. Iron (II) bisglycinate proved to be semi-crystalline. However, depending on the composition of the formulation, it was possible to identify this compound in the tested supplements. For amorphous iron compounds (iron (III) citrate and iron (III) pyrophosphate), the diffraction pattern does not have characteristic diffraction lines. Food supplements containing crystalline iron compounds have a melting point close to the melting point of pure iron compounds. The presence of excipients was found to affect the shapes and positions of the endothermic peaks significantly. Widening of endothermic peaks and changes in their position were observed, as well as exothermic peaks indicating crystallization of amorphous compounds. Weight loss was determined for all dietary supplements tested. Analysis of the DTG curves showed that the thermal decomposition of most food supplements takes place in several steps. The results obtained by a combination of both simple, relatively fast and reliable XRPD and DSC/DTG methods are helpful in determining phase composition, pharmaceutical abnormalities or by detecting the presence of the correct polymorphic form.  相似文献   

17.
The concentrations of selected fat-soluble vitamins and carotenoids in Standard Reference Material (SRM) 3280 Multivitamin/Multielement Tablets have been determined by two independent LC methods, with measurements performed by the National Institute of Standards and Technology (NIST). This SRM has been prepared as part of a collaborative effort between NIST and the National Institutes of Health Office of Dietary Supplements. The SRM is also intended to support the Dietary Supplement Ingredient Database that is being established by the U.S. Department of Agriculture. The methods used at NIST to determine the concentration levels of vitamins A and E, and beta-carotene in the SRM used RPLC with absorbance detection. The relative precision of these methods ranged from 2 to 8% for the analytes measured. SRM 3280 is primarily intended for use in validating analytical methods for the determination of selected vitamins, carotenoids, and elements in multivitamin/multielement tablets and similar matrixes.  相似文献   

18.
A rapid, simple, and accurate ion-pair RPLC method has been developed for simultaneous analysis of vitamin C and major B-complex vitamins. An RP C18 column thermostated at 30 degrees C was used with gradient elution of mobile phase comprising 10 mM potassium dihydrogen phosphate buffer (containing 3 mM sodium hexane-1-sulfonate, adjusted to pH 2.80 with o-phosphoric acid) and methanol at a flow rate of 1.0 mL/min to achieve the best possible separation and resolution of all vitamins in about 11.00 min. The detection was performed at 274 nm. The method has been implemented successfully for simultaneous determination of vitamins present in 12 multivitamin/multimineral pharmaceutical preparations, as well as in human urine. Typical validation characteristics were evaluated in accordance with International Conference on Harmonization guidelines. Good linearity over the investigated concentration levels was observed. Intraday repeatability was < or = 2.0%, and interday variation was < or = 2.6%, for all vitamins. The method can be used for assay of these vitamins over a wide concentration range with good precision and accuracy; hence, it would be appropriate for routine QC as well as in clinical analysis.  相似文献   

19.
Ultra-performance liquid chromatography (UPLC)/MS/MS was applied to measure vitamin D in various foods and nutritional supplements. The run-time of the chromatographic separation was cut from 20 min in HPLC/MS/MS to 10 min in UPLC/MS/MS, while equal or better separation efficiency was achieved to deal with complex food matrixes. Under the optimized conditions, all the previtamins of vitamin D3, D2, and isotope-labeled vitamin D3 were baseline-separated from their corresponding vitamins. It was also demonstrated that many sterol isomers in complex food matrixes that interfere in the analysis could be well-separated from the analytes. Accuracy of this method was evaluated by analysis of NIST SRM 1849 infant formula reference material. With eight replicates, the average vitamin D3 concentration was 0.251 +/- 0.012 mg/kg, an excellent agreement with the certified value of 0.251 +/- 0.027 mg/kg. In addition, spike recovery from a commercial infant formula matrix was in the range of 100 to 108% for both vitamins D3 and D2 at three spike concentration levels. The spike recovery for an even more complex matrix, pet food, was 101-105%. LOQ values were 0.026 and 0.033 IU/g, or 0.086 and 0.11 IU/mL in solution, for vitamins D3 and D2, respectively. The dynamic range had three orders of magnitude, which made the method flexible and useful to deal with the wide concentration range of vitamin D in various samples. The method was robust based on the results of changing the parameters of LC separation and MS measurement. This accurate and reliable vitamin D method increased instrument efficiency and analysis productivity significantly.  相似文献   

20.
This article illustrates the importance of having analytical data on the vitamin and mineral contents of dietary supplements in nutrition studies, and describes efforts to develop an analytically validated dietary supplement ingredient database (DSID) by a consortium of federal agencies in the USA. Preliminary studies of multivitamin mineral supplements marketed in the USA that were analyzed as candidates for the DSID are summarized. Challenges are summarized, possible future directions are outlined, and some related programs at the Office of Dietary Supplements, National Institutes of Health are described. The DSID should be helpful to researchers in assessing relationships between intakes of vitamins and minerals and health outcomes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号